Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Scenario optimization for the tokamak ramp-down phase in RAPTOR: Part A. Analysis and model validation on ASDEX Upgrade

We discuss how the combination of experimental observations and rapid modeling has enabled to improve understanding of the tokamak ramp-down phase in ASDEX Upgrade. A series of dedicated experiments has been performed, to disentangle the effect of individual actuators like plasma current, auxiliary heating and plasma shaping. Optimized discharge termination strategies with increased margin with respect to radiative and vertical stability limits are proposed and tested in experiment. Radiative collapse of the edge $T$ $e$ profile after the HL back-transition is avoided by initially maintaining auxiliary heating during L-mode, showing beneficial effects even after the auxiliary heating is turned off. The capability of the RAPTOR code to model the time evolution of the internal inductance $\ell$ $i3$ has been validated, including the effect of a change in the $I$ $p$ ramp-down rate and the HL transition timing. The reduction of $\ell$ $i3$ caused by rapid compression of the plasma cross-section has been quantitatively recovered in simulations. Successful modeling of the $\ell$ $i3$ time evolution is essential to optimize ramp-down scenarios for future fusion reactors, for which vertical stability and power balance control will be more challenging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheric moisture fields derived by satellite observations over the tropical Pacific Ocean

Values of precipitable water are retrieved over the tropical and subtropical Pacific Ocean from TOVS infrared and microwave channel brightness temperature and OLR observations by means of stepwise linear regression. The most useful temperature and moisture sensing channels are pre-selected from sensitivity tests of a radiative transfer model. Numerous models are developed and tested against collocated radiosonde observations and Nimbus-7 SMMR precipitable water estimates. For RAOB comparisons, the best estimator used 15 TOVS predictors and captured 71.1 deg percent of the variance (+0.62 g/sq cm standard error) for column precipitable water; for precipitable water of 700-500 mb bulk layer, these values were 71.7 percent and +/- 0.17 g/sq cm. Little skill of estimated precipitable water was obtained for moisture above 500 mb. Regressions were less skillful against SMMR, unless collocation parameters were tightly controlled; SMMR was less acceptable than RAOB's because of observational drift and errors. Generally, the most skillful predictors were boundary layer brightness temperatures of TOVS channels and satellite estimated stability indices. 'Moisture channels' were hardly useful except for estimating middle and upper tropospheric moisture. Additional regression models were constructed testing the sensitivity to different observational and meteorological characteristics. Models which used some in situ observations surface observations or stabilities calculated from RAOB, were the most successful. The best of these explained 87.5 percent of the variance but the regression selected almost no TOVS channels, relying instead on conventional RAOB and surface observations. A set of four regression models were developed, stratifying atmospheric characteristics on the basis of collocated OLR values. These models improved the variance explained by 5.0 percent; the model associated with the highest OLR values (275 W/sq m less than or equal to OLR; that is, no cloud) showed only marginal skill. Precipitable water fields were generated from the best TOVS-only model for seven days in January 1983 and compared with SMMR-estimated fields. OLR fields and ECMWF precipitable water analysis. The TOVS regression model compared favorably to the SMMR analysis in amplitudes and features. It revealed more evolving synoptic signal than the ECMWF analysis. In synoptically active regions, it differed with respect to the OLR analysis, primarily because of actual differences in the vertical distribution of water vapor.

Chung, Hyosang↗

Experimental Results From a 2kW Brayton Power Conversion Unit

This paper presents experimental test results from operation of a 2 kWe Brayton power conversion unit. The Brayton converter was developed for a solar dynamic power system flight experiment planned for the Mir Space Station in 1997. The flight experiment was cancelled, but the converter was tested at Glenn Research Center as part of the Solar Dynamic Ground Test Demonstration system which included a solar concentrator, heat receiver, and space radiator. In preparation for the current testing, the heat receiver was removed and replaced with an electrical resistance heater, simulating the thermal input of a steady-state nuclear source. The converter was operated over a full range of thermal input power levels and rotor speeds to generate an overall performance map. The converter unit will serve as the centerpiece of a Nuclear Electric Propulsion Testbed at Glenn. Future potential uses for the Testbed include high voltage electrical controller development, integrated electric thruster testing and advanced radiator demonstration testing to help guide high power Brayton technology development for Nuclear Electric Propulsion (NEP).

Hervol, David↗

Shape Morphing Adaptive Radiator Technology (SMART) Updates to Techport Entry

The Shape-Morphing Adaptive Radiator Technology (SMART) project builds off the FY16 research effort that developed a flexible composite radiator panel and demonstrated its ability to actuate from SMA's attached to it. The proposed FY17 Shape-Morphing Adaptive Radiator Technology (SMART) project's goal is to 1) develop a practical radiator design with shape memory alloys (SMAs) bonded to the radiator's panel, and 2) build a multi-panel radiator prototype for subsequent system level thermal vacuum tests. The morphing radiator employs SMA materials to passively change its shape to adapt its rate of heat rejection to vehicle requirements. Conceptually, the radiator panel has a naturally closed position (like a cylinder) in a cold environment. Whenever the radiator's temperature gradually rises, SMA's affixed to the face sheet will pull the face sheet open a commensurate amount - increasing the radiators view to space and causing it to reject more heat. In a vehicle, the radiator's variable heat rejection capabilities would reduce the number of additional heat rejection devices in a vehicle's thermal control system. This technology aims to help achieve the required maximum to minimum heat rejection ratio required for manned space vehicles to adopt a lighter, simpler, single loop thermal control architecture (ATCS). Single loop architectures are viewed as an attractive means to reduce mass and complexity over traditional dual-loop solutions. However, fluids generally considered safe enough to flow within crewed cabins (e.g. propylene glycol-water mixtures) have much higher freezing points and viscosities than those used in the external sides of dual loop ATCSs (e.g. Ammonia and HFE7000).

Erickson, Lisa↗

Characterization of supersonic radiation diffusion waves

Supersonic and diffusive radiation flow is an important test problem for the radiative transfer models used in radiation-hydrodynamics computer codes owing to solutions being accessible via analytic and numeric methods. We present experimental results with which we compare these solutions by studying supersonic and diffusive flow in the laboratory. Here, we present results of higher-accuracy experiments than previously possible studying radiation flow through up to 7 high-temperature mean free paths of low-density, chlorine-doped polystyrene foam and silicon dioxide aerogel contained by an Au tube. Measurements of the heat front position and absolute measurements of the x-ray emission arrival at the end of the tube are used to test numerical and analytical models. We find excellent absolute agreement with simulations provided that the opacity and the equation of state are adjusted within expected uncertainties; analytical models provide a good phenomenological match to measurements but are not in quantitative agreement due to their limited scope.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A GODUNOV METHOD FOR MULTIDIMENSIONAL RADIATION MAGNETOHYDRODYNAMICS BASED ON A VARIABLE EDDINGTON TENSOR

We describe a numerical algorithm to integrate the equations of radiation magnetohydrodynamics in multidimensions using Godunov methods. This algorithm solves the radiation moment equations in the mixed frame, without invoking any diffusion-like approximations. The moment equations are closed using a variable Eddington tensor whose components are calculated from a formal solution of the transfer equation at a large number of angles using the method of short characteristics. We use a comprehensive test suite to verify the algorithm, including convergence tests of radiation-modified linear acoustic and magnetosonic waves, the structure of radiation-modified shocks, and two-dimensional tests of photon bubble instability and the ablation of dense clouds by an intense radiation field. These tests cover a very wide range of regimes, including both optically thick and thin flows, and ratios of the radiation to gas pressure of at least 10{sup -4}-10{sup 4}. Across most of the parameter space, we find that the method is accurate. However, the tests also reveal there are regimes where the method needs improvement, for example when both the radiation pressure and absorption opacity are very large. We suggest modifications to the algorithm that will improve the accuracy in this case. We discuss the advantages of this method over those based on flux-limited diffusion. In particular, we find that the method is not only substantially more accurate, but often no more expensive than the diffusion approximation for our intended applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison and testing of extended Kalman filters for attitude estimation of the Earth Radiation Budget Satellite

This paper presents the testing and comparison of two extended Kalman filters (EKFs) developed for the Earth Radiation Budget Satellite (ERBS). One EKF updates the attitude quaternion using a four-component additive error quaternion. This technique is compared to that of a second EKF, which uses a multiplicative error quaternion. Brief developments of the algorithms are included. The convergence properties, singularity problems, and normalization techniques of the two filters are addressed. Both filters are tested with simulated ERBS sensor data in addition to real ERBS sensor data. The results of the two filters are also compared to those from the ERBS operational ground support software, which uses a batch differential correction algorithm to estimate attitude and gyro biases.

Bar-Itzhack, Itzhack Y.↗

Background Radiation Survey of the Radiological/Nuclear Countermeasures Test and Evaluation Center

In preparation for operations at the Radiological/Nuclear Countermeasures Test and Evaluation Complex (Rad/NucCTEC), the Department of Homeland Security Domestic Nuclear Detection Office (DHS/DNDO) requested that personnel from the Remote Sensing Laboratory (RSL) conduct a survey of the present radiological conditions at the facility. The measurements consist of the exposure rate from a high-pressure ion chamber (HPIC), high-resolution spectra from a high-purity germanium (HPGe) system in an in situ configuration, and low-resolution spectra from a sodium iodide (NaI) detector in a radiation detection backpack. Measurements with these systems were collected at discrete locations within the facility. Measurements were also collected by carrying the VECTOR backpack throughout the complex to generate a map of the entire area. The area was also to be surveyed with the Kiwi (an array of eight-2-inch x 4-inch x 16-inch NaI detectors) from the Aerial Measuring Systems; however, conflicts with test preparation activities at the site prevented this from being accomplished.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-Hardened, High-Speed Parallel VCSEL Links for High-Energy Physics

Vega Wave Systems, Inc. has been awarded a Small Business Innovative Research (SBIR) Phase II proposal to the U.S. Department of Energy entitled “Radiation-Hardened, High-Speed Parallel VCSEL Links For High-Energy Physics.” The technology proposed under this program is a significant advance (up to 4x) in data rate over current optical link technologies under development. Fermilab supports the technology developed under this proposal as a radiation-hardened, cost-effective solution for optical links for the high-speed data communications in High-Energy Physics and agrees to provide consulting and test engineering in support of this program. Fermilab staff will provide consulting services along with high speed testing of modules before and after radiation testing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Apolipoprotein E expression and behavioral toxicity of high charge, high energy (HZE) particle radiation

Apolipoprotein E (apoE) is a lipid binding protein that plays an important role in tissue repair following brain injury. In the present studies, we have investigated whether apoE affects the behavioral toxicity of high charge, high energy (HZE) particle radiation. METHODS: Sixteen male apoE knockout (KO) mice and sixteen genetically matched wild-type (WT) C57BL mice were used in this experiment. Half of the KO and half of the WT animals were irradiated with 600 MeV/amu iron particles (2 Gy whole body). The effect of irradiation on motor coordination and stamina (Rotarod test), exploratory behavior (open field test), and spatial working and reference memory (Morris water maze) was assessed. ROTAROD TEST: Performance was adversely affected by radiation exposure in both KO and WT groups at 30 d after irradiation. By 60 d after radiation, the radiation effect was lost in WT, but still apparent in irradiated KO mice. OPEN FIELD TEST: Radiation reduced open field exploratory activity 14, 28, 56, 84, and 168 d after irradiation of KO mice, but had no effect on WT mice. MORRIS WATER MAZE: Radiation adversely affected spatial working memory in the KO mice, but had no discernible effect in the WT mice as assessed 180 d after irradiation. In contrast, irradiated WT mice showed marked impairment of spatial reference memory in comparison to non-irradiated mice, while no effect of radiation was observed in KO mice. CONCLUSIONS: These studies show that apoE expression influences the behavioral toxicity of HZE particle radiation and suggest that apoE plays a role in the repair/recovery from radiation injury of the CNS. ApoE deficiency may exacerbate the previously reported effects of HZE particle radiation in accelerating the brain aging process.

Non-NASA Center↗

Test of 50-kw heat-pipe radiator.

A heat pipe radiator consisting of 100 sodium-filled, 1.91-cm OD, stainless steel heat pipes has been tested at temperatures up to 760 C. This radiator was initially designed to have a heat pipe temperature of 740 C with a central coolant channel temperature of 771 C. The as-fabricated radiator heat pipe temperatures varied from 605 C to 700 C when the central coolant channel average temperature was 740 C. The heat pipes operated at 25 C to 110 C lower-than-expected temperatures, resulting in a 43 kW heat rejection capability vs the 50 kW design goal and the 65 kW ultimate capability of the radiator. The 43 kW heat rejection yields a mass/heat rejection ratio of 0.182 kg/kWt which is good for this early state-of-the-art heat pipe radiator. An end-of-mission life specific weight of 0.154 kg/kW is apparently achievable with improvements in radiator fabrication and brazing techniques.

Kikin, G. M.↗

Fornax: A Flexible Code for Multiphysics Astrophysical Simulations

This paper describes the design and implementation of our new multigroup, multidimensional radiation hydrodynamics code Fornax and provides a suite of code tests to validate its application in a wide range of physical regimes. Instead of focusing exclusively on tests of neutrino radiation hydrodynamics relevant to the core-collapse supernova problem for which Fornax is primarily intended, we present here classical and rigorous demonstrations of code performance relevant to a broad range of multidimensional hydrodynamic and multigroup radiation hydrodynamic problems. Our code solves the comoving-frame radiation moment equations using the M1 closure, utilizes conservative high-order reconstruction, employs semi-explicit matter and radiation transport via a high-order time stepping scheme, and is suitable for application to a wide range of astrophysical problems. To this end, we first describe the philosophy, algorithms, and methodologies of Fornax and then perform numerous stringent code tests that collectively and vigorously exercise the code, demonstrate the excellent numerical fidelity with which it captures the many physical effects of radiation hydrodynamics, and show excellent strong scaling well above 100,000 MPI tasks.

79 ASTRONOMY AND ASTROPHYSICS↗

Slow positron beam generator for lifetime studies

A slow positron beam generator uses a conductive source residing between two test films. Moderator pieces are placed next to the test film on the opposite side of the conductive source. A voltage potential is applied between the moderator pieces and the conductive source. Incident energetic positrons: (1) are emitted from the conductive source; (2) are passed through test film; and (3) isotropically strike moderator pieces before diffusing out of the moderator pieces as slow positrons, respectively. The slow positrons diffusing out of moderator pieces are attracted to the conductive source which is held at an appropriate potential below the moderator pieces. The slow positrons have to pass through the test films before reaching the conductive source. A voltage is adjusted so that the potential difference between the moderator pieces and the conductive source forces the positrons to stop in the test films. Measurable annihilation radiation is emitted from the test film when positrons annihilate (combine) with electrons in the test film.

Singh, Jag J.↗

radlibTests v. 1.0

Suite of scripts for performing regression testing of the SCEPTRE radiation transport code, include MMS testing and mesh-convergence analyses

Fan, Wesley↗

Spectroscopy with trapped highly charged ions

We give an overview of atomic spectroscopy performed on electron beam ion traps at various locations throughout the world. Spectroscopy at these facilities contributes to various areas of science and engineering, including but not limited to basic atomic physics, astrophysics, extreme ultraviolet lithography, and the development of density and temperature diagnostics of fusion plasmas. These contributions are accomplished by generating, for example, spectral surveys, making precise radiative lifetime measurements, accounting for radiative power emitted in a given wavelength band, illucidating isotopic effects, and testing collisional-radiative models. While spectroscopy with electron beam ion traps had originally focused on the x-ray emission from highly charged ions interacting with the electron beam, the operating modes of such devices have expanded to study radiation in almost all wavelength bands from the visible to the hard x-ray region; and at several facilities the ions can be studied even in the absence of an electron beam. Photon emission after charge exchange or laser excitation has been observed, and the work is no longer restricted to highly charged ions. Much of the experimental capabilities are unique to electron beam ion traps, and the work performed with these devices cannot be undertaken elsewhere. However, in other areas the work on electron beam ion traps rivals the spectroscopy performed with conventional ion traps or heavy-ion storage rings. The examples we present highlight many of the capabilities of the existing electron beam ion traps and their contributions to physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and measurement of a TE{sub 13} input converter for high order mode gyrotron travelling wave amplifiers

A technique to launch a circular TE{sub 13} mode to interact with the helical electron beam of a gyrotron travelling wave amplifier is proposed and verified by simulation and cold test in this paper. The high order (HOM) TE{sub 13} mode is excited by a broadband Y-type power divider with the aid of a cylindrical waveguide system. Using grooves and convex strips loaded at the lateral planes of the output cylindrical waveguide, the electric fields of the potential competing TE{sub 32} and TE{sub 71} modes are suppressed to allow the transmission of the dominant TE{sub 13} mode. The converter performance for different structural dimensions of grooves and convex strips is studied in detail and excellent results have been achieved. Simulation predicts that the average transmission is ∼−1.8 dB with a 3 dB bandwidth of 7.2 GHz (91.5–98.7 GHz) and port reflection is less than −15 dB. The conversion efficiency to the TE{sub 32} and TE{sub 71} modes are, respectively, under −15 dB and −24 dB in the operating frequency band. Such an HOM converter operating at W-band has been fabricated and cold tested with the radiation boundary. Measurement from the vector network analyzer cold test and microwave simulations show a good reflection performance for the converter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITEP MEVVA ion beam for reactor material investigation

Since 2008 the ion beam irradiation modeling experiments for the testing of reactor materials radiation hardness are under development at the ITEP heavy ion RFQ injector with MEVVA ion source. Ion beam irradiation method has certain advantages for such tests. One of them is high speed of defect formation. Moreover, the irradiated samples can be investigated by traditional investigation methodic because they have not radioactivity induced. The special sample support with electrostatic deflector was constructed and installed at the injector output. The result of ion beam dynamics simulation throughout the deflector as well as the detailed description of the test facility is presented. The first experimental results are presented as well. They have been demonstrated promising results.

36 MATERIALS SCIENCE↗