Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer

We present a model and numerical simulation of a distributed temperature sensor based on a two-pulse differential coherent optical time-domain reflectometer (COTDR). The differential phase measured using a phase-sensitive Rayleigh reflectometer is shown to have a regular component, which is a linear function of temperature, and a random component, which is related to a random distribution of scattering centres in the fibre and restricts the accuracy of measurements of variations in temperature. Measurement accuracy can be improved by reducing the relative contribution of the random component via a decrease in pulse duration and/or an increase in the time delay between pulses. The spatial resolution of a differential two-pulse phase-sensitive reflectometer is shown to be determined by the time delay between pulses and to vary little with pulse duration. At a typical pulse duration (200 ns) and delay time (300 ns), the accuracy in measurements of variations in temperature in the 0.1-K range is 2 % and the spatial resolution is about 30 m. (fibre-optic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of the optical properties of gum and dentin tissue of a human tooth at laser spectral lines in the range of 200 – 800 nm

A change in the optical properties of the tissue of the gums and dentin of a human tooth is experimentally investigated in vitro with the application of a 99.5 % glycerol solution. The kinetics of the total transmittance in the spectral range of 200 – 800 nm on characteristic laser lines is studied. It is shown that the effectiveness of optical clearing, expressed as a relative increase in the total transmittance, for gum tissue in the laser radiation range of 200 – 800 nm can vary significantly (by an order of magnitude). In this case, the absolute values of optical transmittance in the UV region are relatively small due to the strong absorption by the endogenous chromophores of the studied tissues, and in the visible and NIR regions, on the contrary, they are significant, which is due to the absence of strongly absorbing chromophores. The effectiveness of dentin clearing in the entire visible and NIR spectral regions is on average 25 % for 300 minutes of immersion of the sample in a 99.5 % glycerol solution. The presented results are necessary for increasing the efficiency of laser therapy and methods for optical monitoring of morphological changes in biological tissues for the purpose of early diagnosis of diseases. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending the operation range of a phase-sensitive optical time-domain reflectometer by using fibre with chirped Bragg gratings

>A record long external-disturbance detection distance of 140 km without employing optical amplifiers in the fibre line is demonstrated by a phase-sensitive optical time-domain reflectometer (Φ-OTDR) using a fibre section with inscribed chirped fibre Bragg gratings (CFBGs). This solution provides simultaneous operation of Φ-OTDR with a standard single-mode fibre at a distance of up to 100 km and with a CFBG fibre section located from the fibre line input point by at least 140 km. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of gamma radiation by a subterawatt ultrashort laser pulse: optimisation of preplasma and pulse duration

We report an experimental and numerical study of the acceleration of electrons in a plasma interacting with a subterawatt laser pulse (intensity of ∼3 × 10{sup 18} W cm{sup −2} at a pulse duration of 50 fs). A preplasma layer on the surface of a molybdenum target is formed by an additional laser pulse with a duration of 8 ns and an intensity of ∼2 × 10{sup 12} W cm{sup −2}. It is shown that an increase in the laser pulse duration to 1700 fs at a constant energy (and a proportional decrease in intensity) leads to an increase in the yield of bremsstrahlung γ-radiation by more than an order of magnitude when the nanosecond pulse is ahead of the femtosecond one by 15 − 25 ns. Interferometry data and results of diagnostics of optical and γ-radiation of a plasma demonstrate that the collisional ionisation of atoms by electrons oscillating in the field of such a laser pulse plays an essential role in the formation of electron density profile. The sensitivity of the described effect to the level of amplified spontaneous emission is determined, despite the nanosecond pulse impact. Numerical simulations show that at a large pulse duration, the acceleration of electrons is stipulated by the beaking of plasma waves excited during stimulated Raman scattering of laser radiation. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-shift speckle-shearing interferometry

We have numerically simulated the process of measuring stress – strain states by the method of speckle-shearing interferometry using the phase-shift technique. A computer model with the possibility of setting its strain and roughness is developed, which includes a model of a diffusely reflecting test object corresponding to the characteristics of a real membrane, as well as a speckle interferometer model that allows speckle interferograms to be obtained for different speckle sizes and angles between interfering beams. The process of reconstructing the object surface topogram from model speckle interferograms by the phase-shift technique is implemented. Using the developed models, a two-dimensional shearogram are obtained, which is a derivative of the strain field of a circular membrane. Comparison of the results of numerical simulation with experimental data shows that the differences (rms deviations) do not exceed 0.02 μm. It is also shown that the error of interferogram reconstruction by the phase-shift technique increases significantly when the test object strains exceed 12 μm. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic wavefront sensors

A brief historical review of the first designs of holographic wavefront sensors (WFS’s) and the concepts lying in their basis is presented. The main directions in the development of these sensors are highlighted and considered. One of these directions implies a two-stage transition from the use of several separate measuring channels with holograms filtering only one Zernike mode: first to the use of one channel with a multiplexed hologram filtering several first Zernike modes, and then to filtering the entire set of Zernike modes with the aid of one combined multiplexed hologram. Another line of research in this field (related to the first one) is the optimisation of the filter hologram structure in order to reduce cross-modulation interferences, increase multiplexing level, etc. One more line of research implements principles of dynamic holography by introducing spatial light modulators into the WFS composition. Hence, the advantages of time multiplexing of holograms can be used. The approach developed by G. Andersen’s team, aimed at adapting the holographic WFS design for operation as an element of adaptive optical system with a zonal corrector, as well as an approach implying development of hybrid holographic sensors, are considered separately. The results of the authors’ studies of holographic WFS’s with application of the methods of Fourier holography (i.e., holography of focused beams, in particular, using diffuse scatterers in a hologram recording channel) are also reported. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ytterbium laser system for studying parametric amplification of femtosecond pulses with a centre wavelength of ∼2 μm

A laser system is developed with an optical synchronisation of a femtosecond signal with a pump channel. The signal of a driving ytterbium fibre laser with a 60 MHz repetition rate of stretched femtosecond pulses is amplified in energy from several nanojoules to 0.4 mJ at a pulse repetition rate of 3 kHz in a wideband amplifier and then is compressed in time to 250 fs. The obtained radiation is used for generating femtosecond laser pulses with a centre wavelength of ∼2 μm, pulse energy of above 20 μJ, duration of several field oscillations, and phase stabilisation between the electromagnetic field and envelope. The other pulse of the driving fibre laser provides optical synchronisation and a minimal time delay and is directed to a regenerative Yb : YAG disk amplifier for amplification to an energy of 4 mJ at a pulse repetition rate of 3 kHz and duration of 20 ps. A multipass disk amplifier is developed for further increasing the energy of pump chirped pulses to an energy of 70 mJ at a pulse repetition rate of 10 Hz and duration of 400 ps for studying parametric amplification under sub-nanosecond pumping. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interference effects in the high-order harmonic amplification process in the active medium of a plasma-based X-ray laser modulated by an optical field

We study the process of propagation of high harmonics of optical radiation in an active medium of a plasma-based X-ray laser, simultaneously irradiated by an intense optical field of fundamental frequency. It is shown that for moderate plasma dispersion of the active medium at the frequency of the modulating optical field, the energy and relative amplitudes of the harmonics at the output of the medium are determined by their phases at the entrance to the medium, as well as by the time-delay of the harmonics with respect to the modulating field. These dependences are due to interference of high-order harmonics with a set of multi-frequency fields generated by each of the harmonics in the process of coherent scattering in a modulated active medium. The possibilities of using these effects to increase the efficiency of harmonic amplification, to control the harmonic spectrum, and determine the relative phases at the entrance to the medium are discussed on the example of the active medium of hydrogen-like Li{sup 2+} ions (with a 13.5 nm wavelength of an inverted transition). (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods and algorithms for computer synthesis of holographic elements to obtain a complex impulse response of optical information processing systems based on modern spatial light modulators

The possibilities of designing optical devices for data processing and imaging based on the manipulation of coherent light beams by means of spatial light modulators (SLMs) are investigated. A review of commercially available SLMs is presented and the limitations of their complex modulation characteristics are analysed. The main problem of using present-day SLMs is the lack of the ability to modulate directly all states within a unit circle in the complex plane. In this regard, the characteristics of current methods for the synthesis of holographic elements are described that implement a given complex impulse response of the optical system and are optimal for using SLMs with purely amplitude, purely phase, and hybrid amplitude – phase modulation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bragg grating inscription in photosensitive materials by an optical replication process

This paper examines the feasibility of producing multiplexed Bragg gratings for use as diffractive optical elements (DOEs) by coherent optical replication of a surface-relief phase grating into thick-film photosensitive materials. The use of such DOEs in light guide plates (LGPs) for optical imaging systems ensures energy-efficient light input into and output from LGPs and allows one to minimise their weight and size. We present simulation results for the interference structure fabrication process and recording of a series of multiplexed diffraction gratings in photosensitive materials. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic reflective Bragg gratings of gain and their role in the operation of high-power pulsed lasers

The influence of reflective Bragg gratings that are formed in an active medium due to the spatial periodic modulation of gain on the spectral properties of lasing are investigated by an example of a pulsed Nd : YAG laser. It is shown that, at a certain choice of the formation regime of reflective gratings of gain, the lasing bandwidth can be reduced by a factor of 3 – 5, with a corresponding increase in the pulse energy and significant improvement of spatial beam quality. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modelling of the laser amplification process with allowance for the effect of the temperature distribution in an Yb : YAG gain element on the thermophysical and lasing characteristics of the medium

A time-dependent three-dimensional model for the laser amplification process has been constructed with allowance for the effect of the temperature distribution on the thermophysical and lasing characteristics of gain media. We have performed numerical modelling of the laser amplification process in the gain elements of a two-stage subjoule-level cryogenic laser amplifier operating at a pulse repetition rate of up to 1 kHz. It has been shown that taking into account the temperature distribution is of critical importance in calculation of cryogenically cooled laser amplifiers pumped with high-power diodes. We have found optimal diode pump parameters at which the maximum achievable pulse energy at the amplifier output can reach 300 and 570 mJ at pulse repetition rates of 1000 and 500 Hz, respectively. (extreme light fields and their interaction with matter)

42 ENGINEERING↗

Photoacoustic methane gas analyser based on a 3.3-μm optical parametric oscillator

We demonstrate a bench-scale prototype of a photoacoustic (PA) methane gas analyser that takes advantage of an optical parametric oscillator (OPO) based on a fan-out MgO : PPLN structure and resonant differential PA detector. The OPO emits in a repetitively pulsed mode (∼1750 Hz) at an idler wavelength of ∼3.3 μm with an average power of ∼40 – 50 mW. Using the prototype laser PA gas analyser, we experimentally demonstrate the feasibility of measuring the background methane concentration in air (∼2 – 3 ppm of CH{sub 4}). The threshold sensitivity of the PA gas analyser (1σ) is determined to be ∼ 49 ppb of CH{sub 4}. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser cooling of atoms at narrow optical transitions in fields with a polarisation gradient

The efficiency of the polarisation mechanisms of laser cooling of atoms is analysed using narrow optical transitions for which the recoil energy is greater than or comparable to the natural line width. By the example of atoms with the J{sub g} = 1 → J{sub e} = 2 optical transition (J{sub g} and J{sub e} are the total angular momenta of the ground and excited states) in the resonant light fields of σ{sub +} – σ{sub –} and lin⊥lin configurations, the analysis of the minimum achievable energies of laser-cooled atoms is performed. It is shown that the polarisation mechanisms of laser cooling under conditions of a significant influence of recoil effects become less efficient and do not lead to average kinetic energies of an ensemble of atoms below the Doppler limit. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trapping of lithium atoms in a large hollow optical dipole trap

We describe the trapping of lithium atoms in an optical dipole trap about 1 mm in size, with a nearly rectangular potential. The trap has the shape of a cylinder with flat bases. The confinement region is bounded by thin walls produced by light with a frequency blue-detuned from an atomic transition (resonance) frequency by 19 GHz. Before trapping, the gas is collected and cooled in a magneto-optical trap whose centre nearly coincides with the centre of the dipole trap. After switching off the magneto-optical trap, we have photographed the atoms remaining in the dipole trap. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive system for wavefront correction of the PEARL laser facility

The results of the operation of a wavefront correction system based on a deformable bimorph mirror of the PEARL subpetawatt laser facility are presented. An improvement in the quality of focusing of laser radiation, which led to an increase in the Strehl ratio from 0.3 to 0.6, is demonstrated. The features of the compensation for phase distortions of the wavefront in the case of a low pulse repetition rate, as well as the correct allowance for the noise of the CCD camera when calculating the Strehl ratio are investigated. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pump depletion in Raman lasing in a graded index multimode fibre

We examine multimode diode laser pump depletion in a graded index multimode (MM) fibre Raman laser generating a high-quality Stokes beam. Spatial ‘hole burning’ in the transmitted pump beam is demonstrated. A balance model is constructed for interaction of the pump and Stokes waves in the MM Raman laser. Analytical formulas are derived and used in calculations demonstrating qualitative agreement with experimental data. The origin of the observed quantitative discrepancies is discussed. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗