Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Nonlocal Talbot self-imaging with incoherent light

We report a demonstration of nonlocal second-order correlation Talbot effects with incoherent thermal light in a lensless setup containing two optical paths. Self-images of the periodic object, including fractional and phase-reversal Talbot images, are observed at specific distances, in agreement with the theoretical analysis. It is also found that the image quality can be greatly enhanced when higher-order correlations are taken.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-sensitivity infrared vibrational nanospectroscopy in water

Mid-infrared vibrational spectroscopy is a universal label-free tool for identifying molecular compounds in chemical and biological samples on the basis of their ‘fingerprint’ vibrational absorption lines. Vibrational spectroscopy with nanometer spatial resolution can reveal the chemical composition of samples at the nanoscale, and several scanning-probe techniques have been developed to address this need. It is also highly desirable to study biological and chemical samples in their native aqueous environments rather than in air. In aqueous environments, however, the sensitivity of the current vibrational nanospectroscopy techniques deteriorates dramatically . Here, we report the first mid-infrared nanospectroscopy technique that retains nanoscale sensitivity and spatial resolution when the sample and the scanning probe are completely immersed in water. This method overcomes challenges including water absorption and scattering and the mechanical damping of cantilever vibrations. We further demonstrate spectroscopy and imaging of 20- to 50-nm-thick polymer samples with a 25-nm spatial resolution in the biologically relevant Amide I and II spectral regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging in real and reciprocal space at the Diamond beamline I13

The Diamond Imaging and Coherence beamline I13 consists of two independent branchlines for imaging in real and reciprocal space. Different microscopies are available providing a range of spatial resolution from 5µm to potentially 5nm. The beamline operates in the energy range of 6-35keV covering different scientific areas such as biomedicine, materials science and geophysics. Several original devices have been developed at the beamline, such as the EXCALIBUR photon counting detector and the combined robot arms for coherent X-ray diffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incorporation of spatially-resolved current density measurements with photoluminescence for advanced parameter imaging of solar cells

The spatial distribution of device performance parameters of solar cells provides important insight into their operation, including the type and magnitude of conversion losses and potential areas of improvement. In most of the procedures used to create these parameter images, a uniform (i.e., global) short-circuit current density (J SC ) is usually assumed. However, J SC is known to vary over the surface of a solar cell, especially in polycrystalline absorber materials like multicrystalline silicon. In this work, a high speed quantum efficiency measurement rastered over the surface of a solar cell is used to obtain images of J SC . These J SC images are then used to calculate images of series resistance, dark saturation current density, fill factor, and conversion efficiency. Comparisons are made between the images created with a global J SC and with the spatially-resolved J SC . Negligible variation is observed in the series resistance and dark saturation current density images, but a drastic change is observed in the efficiency images between these two methods.

14 SOLAR ENERGY↗

Large area strain analysis using scanning transmission electron microscopy across multiple images

Here, we apply revolving scanning transmission electron microscopy to measure lattice strain across a sample using a single reference area. To do so, we remove image distortion introduced by sample drift, which usually restricts strain analysis to a single image. Overcoming this challenge, we show that it is possible to use strain reference areas elsewhere in the sample, thereby enabling reliable strain mapping across large areas. As a prototypical example, we determine the strain present within the microstructure of a Ni-based superalloy directly from atom column positions as well as geometric phase analysis. While maintaining atomic resolution, we quantify strain within nanoscale regions and demonstrate that large, unit-cell level strain fluctuations are present within the intermetallic phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method to determine the number of nanoparticles in a cluster using conventional optical microscopes

We present a method that uses conventional optical microscopes to determine the number of nanoparticles in a cluster, which is typically not possible using traditional image-based optical methods due to the diffraction limit. The method, called through-focus scanning optical microscopy (TSOM), uses a series of optical images taken at varying focus levels to achieve this. The optical images cannot directly resolve the individual nanoparticles, but contain information related to the number of particles. The TSOM method makes use of this information to determine the number of nanoparticles in a cluster. Initial good agreement between the simulations and the measurements is also presented. The TSOM method can be applied to fluorescent and non-fluorescent as well as metallic and non-metallic nano-scale materials, including soft materials, making it attractive for tag-less, high-speed, optical analysis of nanoparticles down to 45 nm diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of strain and dislocations on GaSb/GaAs quantum dots: From nested to staggered band alignment

We investigate the influence of strain and dislocations on band alignment in GaSb/GaAs quantum dot systems. Composition profiles from cross-sectional scanning tunneling microscopy images are interpolated onto a finite element mesh in order to calculate the distribution of local elastic strain, which is converted to a spatially varying band alignment using deformation potential theory. Our calculations predict that dislocation-induced strain relaxation and charging lead to significant local variations in band alignment. Furthermore, misfit strain induces a transition from a nested (type I) to a staggered (type II) band alignment. Although dislocation-induced strain relaxation prevents the type I to type II transition, electrostatic charging at dislocations induces the staggered band alignment once again.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comment on ''Perfect imaging with positive refraction in three dimensions''

Leonhardt and Philbin [Phys. Rev. A 81, 011804(R) (2010)] have recently constructed a mathematical proof that the Maxwell's fish-eye lens provides perfect imaging of electromagnetic waves without negative refraction. In this comment, we argue that the unlimited resolution is an artifact of having introduced an unphysical drain at the position of the geometrical image. The correct solution gives focusing consistent with the standard diffraction limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direction-dependent localization errors in SPECT images

Purpose: Single photon emission computed tomography (SPECT) is being investigated for imaging inside radiation therapy treatment rooms to localize biological targets. Here, computer simulations were used to analyze locational and directional dependencies in localization errors and to assess the effects of spatial resolution modeling and observer normalization on localization performance. Methods: SPECT images of the XCAT phantom, containing 12 hot tumors, were reconstructed with detector response function compensation (DRC) and without DRC (nDRC). Numerical observers were forced to select the most suspicious tumor location, using normalized cross correlation (NXC) or un-normalized cross correlation (XC), from 3 cm diameter search volumes that each contained only one tumor. For each tumor site, localization was optimized as a function of the iteration number and postreconstruction smoothing. Localization error, the distance between true and estimated tumor positions, was calculated across the ensembles of 80 images. Direction-dependent localization bias and precision were estimated from the image ensemble. Results: For the six superficial tumors in close proximity to the detector trajectory, mean localization errors were <2 mm and were lowest or comparable using DRC-NXC, though differences from DRC-XC and nDRC-NXC were not statistically significant. DRC-NXC did provide statistically significantly better localization than nDRC-XC for five of these six tumors. At the other six sites where attenuation was more severe and the distance was generally greater between the tumor and detector, DRC typically did not show better localization than nDRC. Observer normalization improved the localization substantially for a tumor near the hotter heart. Localization errors were anisotropic and dependent on tumor location relative to the detector trajectory. Conclusions: This computer-simulation study compared localization performance for normalized and un-normalized numerical observers, which were used to estimate tumor positions in SPECT images, reconstructed with and without DRC. For tumors localized to <2 mm on average, which are good candidates for SPECT-guided radiation therapy, localization performance typically improved by compensating for the detector response function and by using a normalized observer. The observed direction-dependent localization errors have important implications for radiation therapy and are relevant to SPECT imaging in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infrared Quantum Dots: Progress, Challenges, and Opportunities

Infrared technologies provide tremendous value to our modern-day society. The need for easy-to-fabricate, solution-processable, tunable infrared active optoelectronic materials has driven the development of infrared colloidal quantum dots, whose band gaps can readily be tuned by dimensional constraints due to the quantum confinement effect. In this Perspective, we summarize recent progress in the development of infrared quantum dots both as infrared light emitters (e.g., in light-emitting diodes, biological imaging, etc.) as well as infrared absorbers (e.g., in photovoltaics, solar fuels, photon up-conversion, etc.), focusing on how fundamental breakthroughs in synthesis, surface chemistry, and characterization techniques are facilitating the implementation of these nanostructures into exploratory device architectures as well as in emerging applications. We discuss the ongoing challenges and opportunities associated with infrared colloidal quantum dots.

36 MATERIALS SCIENCE↗

Correlated imaging through atmospheric turbulence

Correlated imaging through atmospheric turbulence is studied, and the analytical expressions describing turbulence effects on image resolution are derived. Compared with direct imaging, correlated imaging can reduce the influence of turbulence to a certain extent and reconstruct high-resolution images. The result is backed up by numerical simulations, in which turbulence-induced phase perturbations are simulated by random-phase screens inserted into propagation paths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superconducting inductive displacement detection of a microcantilever

We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop of a dc Superconducting Quantum Interference Device (SQUID) microsusceptometer. A local magnetic field as low as 100 μT, generated by a field coil concentric to the SQUID, enables detection of the cantilever thermomechanical noise at 4.2 K. The magnetomechanical coupling and the magnetic spring are in good agreement with image method calculations assuming pure Meissner effect. These measurements are relevant to recent proposals of quantum magnetomechanics experiments based on levitating superconducting microparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast and low-dose computed laminography using compressive sensing based technique

Computed laminography (CL) is well known for inspecting microstructures in the materials, weldments and soldering defects in high density packed components or multilayer printed circuit boards. The overload problem on x-ray tube and gross failure of the radio-sensitive electronics devices during a scan are among important issues in CL which needs to be addressed. The sparse-view CL can be one of the viable option to overcome such issues. In this work a numerical aluminum welding phantom was simulated to collect sparsely sampled projection data at only 40 views using a conventional CL scanning scheme i.e. oblique scan. A compressive-sensing inspired total-variation (TV) minimization algorithm was utilized to reconstruct the images. It is found that the images reconstructed using sparse view data are visually comparable with the images reconstructed using full scan data set i.e. at 360 views on regular interval. We have quantitatively confirmed that tiny structures such as copper and tungsten slags, and copper flakes in the reconstructed images from sparsely sampled data are comparable with the corresponding structure present in the fully sampled data case. A blurring effect can be seen near the edges of few pores at the bottom of the reconstructed images from sparsely sampled data, despite the overall image quality is reasonable for fast and low-dose NDT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid Quantum Vision Transformers for Event Classification in High Energy Physics

Models based on vision transformer architectures are considered state-of-the-art when it comes to image classification tasks. However, they require extensive computational resources both for training and deployment. The problem is exacerbated as the amount and complexity of the data increases. Quantum-based vision transformer models could potentially alleviate this issue by reducing the training and operating time while maintaining the same predictive power. Although current quantum computers are not yet able to perform high-dimensional tasks, they do offer one of the most efficient solutions for the future. In this work, we construct several variations of a quantum hybrid vision transformer for a classification problem in high-energy physics (distinguishing photons and electrons in the electromagnetic calorimeter). We test them against classical vision transformer architectures. Our findings indicate that the hybrid models can achieve comparable performance to their classical analogs with a similar number of parameters.

Unlu, Eyup B. (ORCID:0000000266836463)↗

Theoretical interpretation of electron energy-loss spectroscopic images

In this paper, we discuss the theory of electron energy-loss spectroscopic images in scanning transmission electron microscopy. Three case studies are presented which have as common themes issues of inelastic scattering, coherence and image interpretation. The first is a state-by-state inelastic transitions analysis of a spectroscopic image which does not admit direct visual interpretation. The second compares theory and experiment for two-dimensional mapping. Finally, the third considers imaging in three dimensions via depth sectioning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atom-wide Co Wires on Cu(775) at Room Temperature

We report on a surface phase of the Co-vicinal-Cu(111) system which exhibits self-assembled uniform Co quantum wires that are stable at 300 K. Scanning tunneling microscopy (STM)-imaging measurements show that wires will self-assemble within a narrow range of Co coverage and, within this range, the wires increase in length as coverage is increased. The STM images show that the wires form along the leading edge of the step rise, differentiating it from previously theoretically predicted atomic-wire phases. The formation of relatively long laterally unencapsulated one- and two-atom wires also differentiates it from past experimentally observed step-island formation. Furthermore, our experiments also show directly that the Co wires coexist with another Co phase that had been previously predicted for growth on Cu(111). Our observations allow us to comment on the formation kinetics of the atomic-wire phase and on the fit of our data to a recently developed lattice-gas model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Throughput, High Yield Fabrication of High Quantum Efficiency Back-Illuminated Photon Counting, Far UV, UV, and Visible Detector Arrays

In this paper we discuss the high throughput end-to-end post fabrication processing of high performance delta-doped and superlattice-doped silicon imagers for UV, visible, and NIR applications. As an example, we present our results on far ultraviolet and ultraviolet quantum efficiency (QE) in a photon counting, detector array. We have improved the QE by nearly an order of magnitude over microchannel plates (MCPs) that are the state-of-the-art UV detectors for many NASA space missions as well as defense applications. These achievements are made possible by precision interface band engineering of Molecular Beam Epitaxy (MBE) and Atomic Layer Deposition (ALD).

spectroscopy↗