Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pv module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Voltage mapping and local defects identification in solar cells using non-contact method

Electroluminescence, infrared imaging, and current–voltage curve techniques are used to detect and map underperforming cells in a photovoltaic module or the modules in a photovoltaic string. In this work, we present a non-contact electrostatic voltmeter technique to detect and map the underperforming spots in a cell and the cells in a module. This non-contact technique directly maps the charged surface voltage (671mV) of the superstrate glass, and it had an 11-mV difference with the voltmeter values (660mV). Another data set of voltage values obtained by electroluminescence images conversion into a voltage map showed a difference of 7mV with the non-contact voltmeter values. Further, the direct voltage values obtained at various good and poor-performing spots of the cells using this technique are 3.69V and 3.79V and are validated using the voltage values obtained in electroluminescence analysis and the difference in voltage obtained by the two techniques is determined to be less than 2%. In this work, we combine the strengths of two complementary techniques of the electrostatic voltmeter (strength: quantitative) and electroluminescence (strength: spatial mapping) to obtain a quantitative spatial mapping of defects. Furthermore, this work is extendable to detect the poor-performing modules in solar PV power plants.

14 SOLAR ENERGY↗

Sun-Relative Pointing for Dual-Axis Solar Trackers Employing Azimuth and Elevation Rotations

Dual axis trackers employing azimuth and elevation rotations are common in the field of photovoltaic (PV) energy generation. Accurate sun-tracking algorithms are widely available. However, a steering algorithm has not been available to accurately point the tracker away from the sun such that a vector projection of the sun beam onto the tracker face falls along a desired path relative to the tracker face. We have developed an algorithm which produces the appropriate azimuth and elevation angles for a dual axis tracker when given the sun position, desired angle of incidence, and the desired projection of the sun beam onto the tracker face. Development of this algorithm was inspired by the need to accurately steer a tracker to desired sun-relative positions in order to better characterize the electro-optical properties of PV and CPV modules.

14 SOLAR ENERGY↗

Validation of Heliovolt Modules at the RTCs

The purpose of the project is to design, construct, and commission up to 10 kW DC of Heliovolt’s module technologies. These PV demonstration systems are targeted for installation at: (1) Sandia’s RTC site located in Albuquerque, New Mexico, (2) Sandia’s RTC site located at Florida Solar Energy Center (FSEC) in Cocoa, FL, and (3) at NREL’s RTC site located in Aurora, CO. 5kW of PV was installed at each of these sites, but before the other 5 kW could be installed, Heliovolt Corporation ceased operations and liquidated all assets. The assets remaining at each RTC site have been legally abandoned. Sandia is currently assessing how these assets can be reused to benefit future research projects.

14 SOLAR ENERGY↗

Final Technical Report for CENTRIA's EnergyPeak Building Integrated Photovoltaics ( BIPV ) for Standing Seam Metal Roofing Project (DE-FG36-08GO88131)

Architects have said they will adopt Solar Roofs when they are integrated into roofing systems, building design, plans and specifications, and bidding procedures . Standing Seam Metal Roof manufacturers will answer these architects needs if someone will establish standards, pre-design systems, write specifications, tests systems, meet codes, etc. Energypeak was developed to provide the above so Architects can specify BIPV Standing Seam Roof Systems and Manufacturers can brand, market, sell, manufacture and deliver these systems. EnergyPeak took on the challenge to design BIPV modules using current PV technology, design electrical components, develop wire management systems, test, meet codes, write cad drawings and specifications, commercialize and deliver complete standards to the Industry.

14 SOLAR ENERGY↗

US DOE Regional Test Centers Program - 2016 Annual Report.

The US Department of Energy’s Regional Test Center (RTC) program provides outdoor validation and bankability data for innovative solar technologies at five sites across the US representing a range of climate conditions. Data helps get new technologies to market faster and improves US industry competitiveness. Managed by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL), the RTC program partners with US manufacturers of photovoltaic (PV) technologies, including modules, inverters, and balance-of-system equipment. The study is collaborative, with manufacturers (also known as RTC industry partners) and the national labs working together on a system design and validation strategy that meets a clearly defined set of performance and reliability objectives.

14 SOLAR ENERGY↗

Flux concentrations on solar dynamic components due to mispointing

Mispointing of the solar dynamic (SD) concentrator designed for use on Space Station Freedom (SSF) causes the optical axis of the concentrator to be nonparallel to the incoming rays from the Sun. This causes solar flux not to be focused into the aperture hole of the receiver and may position the flux on other SSF components. A Rocketdyne analysis has determined the thermal impact of off-axis radiation due to mispointing on elements of the SD module and photovoltaic (PV) arrays. The conclusion was that flux distributions on some of the radiator components, the two-axis gimbal rings, the truss, and the PV arrays could present problems. The OFFSET computer code was used at Lewis Research Center to further investigate these flux distributions incident on components. The Lewis study included distributions for a greater range of mispoint angles than the Rocketdyne study.

Rylicki, Daniel S.↗

Applications of Self-Powered Modulating Retroreflectors

NASA Glenn Research Center, in partnership with the U.S. Naval Research Laboratory, has developed self-powered modulating retroreflectors (SMRR) for energy efficient, wireless communications applications. A modulating retroreflector (MRR) consists of a multiple quantum well (MQW) optical detector mounted in front of a retroreflector. The SMRR is integrated the MRR with monolithically integrated module (MIM) photovoltaic (PV) receivers to generate power from interrogating laser-light. SMRRs will provide self power capability that would eliminate batteries or other power sources for MRR drive electronics and sensors. The device can be applied to optical communications, wireless sensor and optical ID tags without a battery. Potential applications and preliminary tests based on a lunar surface communications and navigation simulation will be presented.

Chun, Kue↗

Evaluation of Installation Time for SMASHmount by SMASHsolar

The Department of Energy SunShot Incubator program provides early-stage assistance to help startup companies cross technological barriers to commercialization while encouraging private sector investment. The SunShot Incubator program aims to shorten the time it takes for a young business or company to develop an innovative product concept and make it commercially available, which includes product prototyping, deployment, and, potentially, manufacturing. SMASHsolar was selected as an Incubator awardee to develop a simple, snap-together, module-integrated photovoltaic (PV) mounting system in attempts to dramatically reduce the time, effort and skill needed to install rooftop solar. In support of this award, the National Renewable Energy Laboratory worked with SMASHsolar to develop a procedure for evaluating the installation time required for the SMASHmount system vs. widely-available rail systems. Amongst several installations, NREL measured the following installation times, subject to the qualifications and conditions described later in this report. NREL found that the SMASHsolar SMASHmount system was installed between 15% and 37% faster than tested competing systems after one or two installations of the system.

14 SOLAR ENERGY↗

Measuring the Stress Factors for Photovoltaic (PV) Backsheet Degradation

Back sheet failure has resulted in power loss and large-scale recall of photovoltaic modules, resulting in billions of dollars in lost revenue. The light exposure on the backside of a photovoltaic module comes primarily from reflected light which alters the distribution of natural sunlight. Because of this, modelling the backside exposure and duplicating the exposure is much more difficult than modeling the frontside exposure. This project aims to study how various back sheets and junction box materials degrade under different conditions and to develop Python code to help model and predict degradation. The stress factors for back-sheet degradation must be quantified to extrapolate accelerated stress tests to the field. Test samples were placed in the A3, A4, and A5 conditions, as defined in IEC 62788-7-2, to assess the temperature and humidity dependence of ultraviolet (UV) induced degradation. We are utilizing a custom chamber with exposure from 0.5 UV-suns to 5 UV-suns to understand the dependence of degradation on light intensity. A group of samples put in the A3 condition had glass filters with 50% UV cut-offs of 320 nm, 335 nm, and 360 nm to assess the wavelength dependence of UV degradation. All this data is necessary to assess the impact of non-standard UV light exposure. The material evaluation tests include gloss measurements, attenuated total internal reflectance Fourier transform infrared spectroscopy (ATR-FTIR), UV-visible reflectance/transmittance utilizing a Cary Ci7000 spectrophotometer, and a nano-indenter for surface hardness and modulus measurements. Alongside the experimental work, there is a computational effort using raytracing and Python open-source tools in PVDeg , PVLib, and Bifacial_Radiance. This code will create specific exposure scenarios and enable the evaluation of chamber degradation relative to field degradation. Equation 1 is a strawman equation used to model degradation on the backside of a PV module. We will create simplified code, based on the results of ray-tracing calculations, which uses a view factor approach to provide fast calculations for the most common exposure scenarios.

14 SOLAR ENERGY↗

Techno-economic Analysis of Novel PV Plant Designs for Extreme Cost Reductions

A techno-economic analysis is underway examining the cost and performance of future large-scale photovoltaic (PV) plant components, including bifacial modules, tandem modules, increased plant voltage architectures, and module-level power electronics. Integration of these components into PV plant designs is compared with current PV technologies based on levelized cost of electricity (LCOE). Baseline models are developed and validated against recorded PV plant performance data. Expected cost and performance data of future PV technologies are incorporated into the baseline models. An evolutionary algorithm is utilized to optimize PV plant configuration, technology combination, and LCOE. This paper focuses on the bifacial module analysis.

14 SOLAR ENERGY↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

Setting the Bar for Device Performance of Photovoltaic Cells and Modules

Cutting-edge photovoltaic (PV) research and development benefits from NREL's world-record accuracy in device performance measurements. NREL is a global leader for PV calibration services to help control manufacturing quality, assess degradation rates, and develop new technologies.

14 SOLAR ENERGY↗

Employing Weibull Analysis and Weakest Link Theory to Resolve Crystalline Silicon PV Cell Strength Between Bare Cells and Reduced- and Full-Sized Modules

Weibull analysis and weakest link theory are employed to resolve the probability of crystalline silicon PV cell fracture when measured as bare cells and when stressed in reduced- and full-sized modules. Experimental results indicated that the characteristic cell strength is reduced by ~20% once packaged into the laminate of a one-cell module and loaded in four-point flexure (4PF). This experimental observation was shown consistent with a weakest link theory prediction that the strength limiting flaws reside on the surface of the cell's edge. Here, the analysis is ultimately extended to present the equivalent loading of four-cell modules by uniform pressure and 4PF and a uniformly loaded full-sized module and demonstrates that smaller, representative, modules must be loaded to a much higher level than their parent full-sized modules to achieve an equivalent probability for cell fracture.

14 SOLAR ENERGY↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

Investigation of a Wedge Adhesion Test for Edge Seals

Many photovoltaic (PV) technologies have been found to be sensitive to moisture that diffuses into a PV package. Even with the use of impermeable frontsheets and backsheets, moisture can penetrate from the edges of a module. To limit this moisture ingress pathway from occurring, manufacturers often use a low permeability polyisobutylene (PIB) based edge seal filled with desiccant to further restrict moisture ingress. Moisture ingress studies have shown that these materials are capable of blocking moisture for the 25-year life of a module; but to do so, they must remain well-adhered and free of cracks. This work focuses on adapting the Boeing Wedge test for use with edge seals laminated using glass substrates as part of a strategy to assess the long-term durability of edge seals. The advantage of this method is that it duplicates the residual stresses and strains that a glass/glass module may have when the lamination process results in some residual glass bending that puts the perimeter in tension. Additionally, this method allows one to simultaneously expose the material to thermal stress, humidity, mechanical stress, and ultraviolet radiation. The disadvantage of this method generally is that we are limited by the fracture toughness of the glass substrates that the edge seal is adhered to. However, the low toughness of typical uncrosslinked or sparsely crosslinked PIB makes them suitable for this technique. We present data obtained during the development of the wedge test for use with PV edge seal materials. This includes development of the measuring techniques and evaluation of the test method with relevant materials. We find consistent data within a given experiment, along with the theoretical independence of fracture toughness measurements with wedge thickness. This indicates that the test methodology is reproducible. However, even though individual experimental sets are consistent, the reproducibility between experimental sets is poor. We believe this may be due to inconsistencies in sample history, sample batch, or small changes in sample preparation/assembly from one month to the next. Because the fracture strength of typical edge seal materials is so low, they cannot be relied upon for mechanical strength. A small stress or strain on the edge seal is capable of promoting delamination or tearing causing the edge seal to fail. Because of this, edge seals are very dependent on the processing and construction parameters in the full size PV module such that any long term evaluation of their durability must be conducted on full size modules to be accurate.

14 SOLAR ENERGY↗