Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “panel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Empirical binary tomography calibration (EBTC) for the precorrection of beam hardening and scatter for flat panel CT

Purpose: Scatter and beam hardening are prominent artifacts in x-ray CT. Currently, there is no precorrection method that inherently accounts for tube voltage modulation and shaped prefiltration. Methods: A method for self-calibration based on binary tomography of homogeneous objects, which was proposed by B. Li et al. [''A novel beam hardening correction method for computed tomography,'' in Proceedings of the IEEE/ICME International Conference on Complex Medical Engineering CME 2007, pp. 891-895, 23-27 May 2007], has been generalized in order to use this information to preprocess scans of other, nonbinary objects, e.g., to reduce artifacts in medical CT applications. Further on, the method was extended to handle scatter besides beam hardening and to allow for detector pixel-specific and ray-specific precorrections. This implies that the empirical binary tomography calibration (EBTC) technique is sensitive to spectral effects as they are induced by the heel effect, by shaped prefiltration, or by scanners with tube voltage modulation. The presented method models the beam hardening correction by using a rational function, while the scatter component is modeled using the pep model of B. Ohnesorge et al. [''Efficient object scatter correction algorithm for third and fourth generation CT scanners,'' Eur. Radiol. 9(3), 563-569 (1999)]. A smoothness constraint is applied to the parameter space to regularize the underdetermined system of nonlinear equations. The parameters determined are then used to precorrect CT scans. Results: EBTC was evaluated using simulated data of a flat panel cone-beam CT scanner with tube voltage modulation and bow-tie prefiltration and using real data of a flat panel cone-beam CT scanner. In simulation studies, where the ground truth is known, the authors' correction model proved to be highly accurate and was able to reduce beam hardening by 97% and scatter by about 75%. Reconstructions of measured data showed significantly less artifacts than the standard reconstruction. Conclusions: EBTC appears to be an efficient algorithm to precorrect CT raw data for beam hardening and scatter and it can account for ray-dependent spectral variations as they occur due to the heel effect, due to shaped prefiltration, or due to variations in tube voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-E-BRB-01: Panel Member

In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms of (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.

60 APPLIED LIFE SCIENCES↗

MO-E-BRB-02: Panel Member

In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms of (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.

60 APPLIED LIFE SCIENCES↗

MO-E-BRB-00: PANEL DISCUSSION: SBRT/SRS Case Studies - Lung

In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms of (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.

60 APPLIED LIFE SCIENCES↗

MO-F-201-02: Panel Member

The goal of this session is to provide guidance to medical physicists undergoing the American Board of Radiology certification process in therapeutic medical physics. This panel discussion will focus on parts 2 (computer-based) and 3 (oral) of the examination. Unlike the latter portions of the exam which are specialty-driven, part 1 is universal for all medical physics fields and will not be addressed. This session is structured into different topics that aim to guide the participants on how to successfully prepare for the board exams. The subjects of discussion will include timing and strategies for exam preparation, crucial differences in preparing for the clinical computer-based exam versus the oral exam, what study tools are currently available for each, etc. The panel discussion format will allow the speakers to collectively present their experience and advice relating to each topic and foment audience participation. Learning Objectives: Know the main differences between what is expected for parts 2 and 3 Know different resources for test preparation Know how to formulate a plan to best study for each part based on the specific skill set the two parts require Know how to best present his/her answers during the oral examination – demeanor, answer structure, etc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bexar County Parking Garage Photovoltaic Panels

The main objective of the Bexar County Parking Garage Photovoltaic (PV) Panel project is to install a PV System that will promote the use of renewable energy. This project will also help sustain Bexar County ongoing greenhouse gas emissions reduction and energy efficiency goals. The scope of this project includes the installation of a 100-kW system on the top level of a new 236,285 square feet parking garage. The PV system consists of 420 solar panels that covers 7,200 square feet and is tied into the electric-grid. It provides electricity to the office area located within the garage. The estimated annual electricity production of the PV system is 147,000 kWh per year.

14 SOLAR ENERGY↗

Round 2 Update of Stress Testing Results for Organic Light-Emitting Diode Panels and Luminaires

Organic light-emitting diode (OLED) sources are a potential solid-state lighting technology for use in indoor lighting applications. Some of the advantages offered by OLEDs include thin profiles, low glare, diffuse lighting, and unique form factors. The U.S. Department of Energy (DOE) has released five reports about OLED technologies to provide information and analysis to the lighting industry. These reports include the evaluation of two different field deployment sites, a market analysis, and two independent assessments of the performance of select commercially available OLED products. This report builds on earlier DOE efforts with OLED technology by updating information about previously benchmarked OLED products (i.e., the Chalina luminaire from Acuity Brands and the Brite 2 and Brite Amber panels from OLEDWorks) in accelerated stress tests (ASTs). In addition, this report also provides an initial analysis of the performance of recently released OLED products—the Brite 3 panels from OLEDWorks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accelerating the Adoption of the Solid Panel Structural System

This report, "Accelerating the Adoption of the Solid Panel Structural System", explores the structural properties, capabilities, and applications for an innovative “studless” building system that uses a plate-like approach and “Perfect Wall” principles for an efficient, durable, and robust wall system. A comprehensive testing regime was completed to fully characterize the structural behavior of the Solid Panel Structural system. These results were used to develop an engineering guide that can be used by architects and engineers for design and code approval.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nanoporous Wood Chips Based Sizable, Robust, and Low-Cost Honeycomb Vacuum Insulation Panels (DOE BENEFIT Final Research Performance Progress Report (RPPR))

Conventional vacuum insulation panels (VIPs) suffer from severe limitations including high cost, vulnerability to perforation, and significant performance degradation over time due to vacuum loss. InventWood Inc. (IW) and partnering teams completely re-engineered the VIP structure by constructing arrays of isolated vacuum-cells to enable limited cutting at designated areas (in between vacuum cells) and reduced consequential vacuum loss due to puncture. The teams also replaced the expensive vacuum insulation core materials with a low-cost commercial wood pulp and recycled long fiber. The wood pulp derived VIP can deliver an overall panel insulation of R15 (<0.01W/m·K) with over 90% thermal resistance retention after cutting (R13.5 overall, R5 along the cut edges). In addition, the vacuum-cell-array design minimizes edge losses, resulting in more durable performance, longer service life (>50 years), and higher R-value per dollar towards a cost target of <$1/ft 2 ·in. It is anticipated that the Nanochip-VIP will attract strong market interest and become an affordable insulation solution for energy efficient buildings and retrofits, leading to significant reductions in energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Solar Panel Defect Detection Hardware and Defect Analysis Software (CRADA Final Report)

The CRADA work involved 1) the development of a machine learning software architecture to automatically detect defects within Electroluminescence images of solar panels, and 2) demonstrations of the usefulness of UV Fluorescence (UVF) defect detection for a wide variety of defect types across many different solar panel technologies with different field or environmental chamber histories.

14 SOLAR ENERGY↗

Novel Solar Panel Defect Detection Hardware and Defect Analysis Software (CRADA Final Report)

The CRADA work involved 1) the development of a machine learning software architecture to automatically detect defects within Electroluminescence images of solar panels, and 2) demonstrations of the usefulness of UV Fluorescence (UVF) defect detection for a wide variety of defect types across many different solar panel technologies with different field or environmental chamber histories.

14 SOLAR ENERGY↗

Constitutive Modeling of the Facesheet to Core Interface in Honeycomb Sandwich Panels Subject to Mode I Delamination

A new cohesive zone traction-separation law, which includes the effects of fiber bridging, has been developed, implemented with a finite element (FE) model, and applied to simulate the delamination between the facesheet and core of a composite honeycomb sandwich panel. The proposed traction-separation law includes a standard initial cohesive component, which accounts for the initial interfacial stiffness and energy release rate, along with a new component to account for the fiber bridging contribution to the delamination process. Single cantilever beam tests on aluminum honeycomb sandwich panels with carbon fiber reinforced polymer facesheets were used to characterize and evaluate the new formulation and its finite element implementation. These tests, designed to evaluate the mode I toughness of the facesheet to core interface, exhibited significant fiber bridging and large crack process zones, giving rise to a concave downward concave upward pre-peak shape in the load-displacement curve. Unlike standard cohesive formulations, the proposed formulation captures this observed shape, and its results have been shown to be in excellent quantitative agreement with experimental load-displacement and apparent critical energy release rate results, representative of a payload fairing structure, as well as local strain fields measured with digital image correlation.

composites↗

Progress and Strategies for Testing of Materials for Solar Panels

Accelerated testing is key to confident launch of a new product. However, for new products like solar panels, the best approach is not always clear. The challenge for materials manufacturers is that test times can be long. Also, small-coupon testing may not predict the behavior in the full-size module, but testing of the full-size module is too expensive. As a result, solar panel test standards like IEC 61215 are useful, but are not sufficient. Material manufacturers have needed to define their own test protocols. This presentation will review some historical data (e.g., data show that manufacturers are making great progress toward reducing encapsulant discoloration) and describe advances in material testing (for example, new techniques are being demonstrated on how to more quantitatively assess adhesion, detect tendency for delamination, and understand how encapsulant properties affect other properties like cracking of cells). The International PV Quality Assurance Task Force has been researching climate-specific weathering tests toward the goal of defining international standards that would simplify qualification and quality assurance testing for materials. The status of these tests and the strategies for how to organize these standards to best meet the needs of the industry will be discussed.

14 SOLAR ENERGY↗

Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolization for Leiomyomata: Optimization of the Radiation Dose to the Patient Using a Flat-Panel Detector Angiographic Suite

The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The second step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 {+-} 1.3 to 0.4 {+-} 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 {+-} 27,207 {mu}Gy m{sup 2} for group A to 9,515 {+-} 4,520 {mu}Gy m{sup 2} for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 {+-} 238 mGy (group A) to 83 {+-} 41 mGy (group B) and from 388 {+-} 246 mGy (group A) to 85 {+-} 39 mGy (group B), respectively. Effective doses decreased from 112 {+-} 71 mSv (group A) to 24 {+-} 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impacts of year-to-year weather variability and inter-panel spacing on agrivoltaic crop yields in Massachusetts

Deployment of utility-scale solar power plants could lead to agricultural land-use changes. Agrivoltaics, a dual land use combining solar and agriculture on the same land, can provide multiple environmental benefits, including improving soil quality and water use efficiency. The body of agrivoltaic field data is still growing, and crop responses to different solar configurations under different local climates are highly varied. We investigate the impact of adding spacing between adjacent solar panels in a fixed-tilt system to improve light diffusion to crops. For four crops (broccoli, peppers, kale, Swiss chard) grown across 3 years in an agrivoltaic system in Massachusetts, we found that only kale had a linearly increasing trend as the inter-panel spacing increased from 0.6 m to 1.5 m (2 ft to 5 ft). However, there were significant year-to-year differences in the yield of agrivoltaic versus control fields. Agrivoltaic and full sun fields produced equivalent yields in a hot, dry year, whereas the full-sun control beds produced more salable yield for all four crops in a warm, wet year. This demonstrates variability of agricultural outcomes and the need for more multi-year studies to ensure agrivoltaic impacts are not under- or overestimated.

14 SOLAR ENERGY↗