Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Quantum Computing with Exciton Qubits in Colloidal Semiconductor Nanocrystals

The present work evaluates the feasibility of quantum computing with exciton qubits in coupled colloidal semiconductor nanocrystals (NCs). A strategy for manipulating two-qubit states of colloidal NC hetero-dimers is described. We show that a sequence of laser pulses with the same photon energy can bring excitonic states of a nanocrystal hetero-dimer into entanglement and perform arbitrary qubit rotations (quantum gates). Our simulations of a realistic two-particle assembly of CdSe/CdS core/shell NCs demonstrate that such two-qubit gate operations can be driven by optical parametric oscillators with a theoretical error of 0.1%. Furthermore, a strategy for upscaling two-qubit hetero-dimers to N-qubit exciton gates in semiconductor NC assemblies is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust control of the minima of high-order harmonics by fine-tuning the alignment of CO 2 molecules for shaping attosecond pulses and probing molecular alignment

In a recent paper, we reported that the position and depth of the minima in the harmonic spectra of CO 2 molecules can be dramatically manipulated by a slight change of the degree of alignment, thus providing a convenient method of shaping attosecond pulses which could lead to the splitting of a typical single attosecond burst into two. Here, we demonstrate that harmonic minima can also be dramatically controlled by changing the pump-probe angles to shape attosecond pulses. In the meanwhile, since the pump-probe angle-dependent harmonic spectra are very sensitive to the degree of alignment, harmonic spectra can also be used to calibrate the alignment distribution of molecules. In this work we identify such robust control of harmonic generation is due to the optical property of CO 2 and the coherent harmonic emission from the oriented molecules. The photoionization transition dipoles (PITDs) of CO 2 exhibit deep minima that change rapidly with molecular orientations accompanied by large phase changes of π in PITDs, thus leading to strong interference when the dipoles are added up coherently.

74 ATOMIC AND MOLECULAR PHYSICS↗

Single-pass Cr:ZnSe amplifier for broadband infrared undulator radiation

An amplifier based on a highly-doped chromium zinc-selenide (Cr:ZnSe) crystal is proposed to increase the pulse energy emitted by an electron bunch after it passes through an undulator magnet. The primary motivation is a possible use of the amplified undulator radiation emitted by a beam circulating in a particle accelerator storage ring to increase the particle beam’s phase-space density—a technique dubbed optical stochastic cooling (OSC). This paper uses a simple four energy level model to estimate the single-pass gain of Cr:ZnSe and presents numerical calculations combined with wave-optics simulations of undulator radiation to estimate the expected properties of the amplified undulator wave-packet.

43 PARTICLE ACCELERATORS↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗

Joint Experimental and Computational Characterization of Sum-Frequency Generation between a Continuous Wave Laser and an Ultrafast Frequency Comb Laser for Tunable Laser Development

Ultrafast optical frequency combs allow for both high spectral and temporal resolution in molecular spectroscopy and have become a powerful tool in many areas of chemistry and physics. Ultrafast lasers and frequency combs generated from ultrafast mode-locked lasers often need to be converted to other wavelengths. Commonly used wavelength conversions are optical parametric oscillators, which require an external optical cavity, and supercontinuum generation combined with optical parametric amplifiers. Whether commercial or home-built, these systems are complex and costly. Here, we investigate an alternative, simple, and easy-to-implement approach to tunable frequency comb ultrafast lasers enabled by new continuous-wave laser technology. Sum-frequency generation between an Nd:YAG continuous-wave laser and a Yb:fiber femtosecond frequency comb in a beta-barium borate (BBO) crystal is explored. The resulting sum-frequency beam is a pulsed frequency comb with the same repetition rate as the Yb:fiber source. SNLO simulation software is used to simulate the results and provide benchmarks for designing future systems to achieve wavelength conversion and tunability in otherwise difficult-to-reach spectral regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Picosecond Synchronization System for Quantum Networks

The operation of long-distance quantum networks requires photons to be synchronized and must account for length variations of quantum channels. We demonstrate a 200 MHz clock-rate fiber optic-based telecommunication C-band quantum network using off-the-shelf components combined with custom-made electronics. The network is backed by a scalable and fully automated synchronization system with ps-scale timing resolution. Synchronization of the photons is achieved by distributing O-band-wavelength laser pulses between network nodes. Specifically, we distribute photon pairs between three nodes, and measure a reduction of coincidence-to-accidental ratio from 77 to only 42 when the synchronization system is enabled, which permits high-fidelity qubit transmission. Our demonstration sheds light on the role of noise in quantum communication and represents a key step in realizing deployed co-existing classical-quantum networks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipulse Optical-Rectification-Based THz Source for Accelerator Applications

THz sources offer the potential for higher frequencies and higher breakdown thresholds in accelerating structures in comparison with conventional RF sources. They also benefit from larger field strengths, field gradients, better beam synchronization and compactness. In this work, we first present the development of a 49μJ single-cycle THz source centered at 0.6 THz that provides fields over 30 MV/m. With further modifications, multicycle pulses were produced, narrowing the bandwidth of the source and potentially easing the coupling of THz radiation to relativistic electron beams and increasing the usability in other areas of research.

Lenz, Maximilian (ORCID:0009000579693042)↗

Pulsed laminar falling films in vertical tubes: Maintaining a continuous liquid film with reduced film thickness

Falling-liquid-film heat transfer is important to a wide variety of industrial applications, including two-phase thermosyphons, falling-film evaporators in the food industry, heat exchangers in fuel-ethanol processing, and the chemical service industry. Particularly for laminar falling films, the heat transfer increases as the film thickness decreases, hence it is desirable to keep the films as thin as possible. This article presents a periodically-pulsed flow concept to reduce the average mass flow inside a vertical tube. The technique provides thinner films than can be achieved with continuous flow. A drainage model is adopted to predict the film thickness as a function of flow rate and location along the tube. The concept is confirmed experimentally by measuring the film thickness in real time in a circular tube using a laser-based absorption technique. A new heat-transfer-based film continuity measurement is also integrated into the optical film measurement setup. Water at ambient temperature and pressure is used for this work. Film thickness reductions of up to 60%, and liquid-film volume-flow reductions of up to 80% compared to the minimum continuous-flow film have been obtained. The time-varying film thickness profile can also be controlled to a limited extent, which may be of interest for process industries.

42 ENGINEERING↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Radiation-induced negative optical nonlinearities in fused silica, sapphire, and borosilicate glass

Here, negative nonlinear absorption is reported in neutron- and gamma-irradiated high-OH content fused silica, low-OH content fused silica, sapphire, borosilicate glass, and radiation-resistant borosilicate glass irradiated to total neutron fluences of 3.4 × 10 16 n ∙ cm –2 (42 Mrad γ), 1.7 × 10 17 n ∙ cm –2 (211 Mrad γ), and 3.6 × 10 17 n ∙ cm –2 (433 Mrad γ). Nonlinear absorption coefficients were measured via Z-scan and are on the order of – (10 –14 –10 –10 ) m∙W –1 . The Z-scan also reveals a negative nonlinear index of refraction in neutron- and gamma-irradiated radiation-resistant borosilicate glass on the order of –10 –19 m 2 ∙ W –1 . Thermal annealing at temperatures up to 800 °C is shown to restore these nonlinearities to their positive unirradiated values in all four materials. All Z-scan measurements were performed at 532 nm with a nanosecond pulsed laser. The occurrence of negative nonlinearities may be attributed to the presence of metallic impurities and the resulting saturable absorption. A limited effect of photobleaching is observed in measurements and is quantified in multiple Z-scans.

36 MATERIALS SCIENCE↗

Continuum laser absorption spectroscopy of C 2 (a 3 Π u ) in a sublimating cloud of carbon black

A direct optical absorption diagnostic has been developed for rotationally resolved measurements of diatomic carbon (a 3 Π u →d 3 Π g (0,0) and (1,1)) at a repetition rate of 525 kHz and resolution of 7.3 pm over the range of 511.1–514.1 nm. The diagnostic utilizes a high-power pulsed continuum laser light source dispersed in a spectrograph and imaged by a high-speed camera. Measurements have been performed that capture the temporal evolution of C 2 number density and temperature of a cloud of carbon black sublimating in shock heated gas at high temperature and pressure (T = 5500 K, P = 3.7 atm). A simultaneous light absorption measurement of the condensed phase enables comparisons of the gaseous C 2 number density to the condensed phase mass. The continuum laser absorption diagnostic is applied to C 2 in this work but shows promise in being a simple “drop-in” system for absorption spectroscopy in the visible range at rapid repetition rates and high dispersion, filling an important gap for laser diagnostic systems.

Willhardt, Colton Dean [Univ. of Illinois at Urban↗

Two-dimensional Thomson scattering measurements of misaligned electron density and temperature gradients and associated Biermann battery produced fields

We present optical Thomson scattering measurements of electron density and temperature in high Mach number laser-driven blast waves in homogeneous gases. Taylor–Sedov blast waves are launched in nitrogen (N2) or helium (He) at pressures between 0.4 mTorr and 10 Torr by ablating a solid plastic target with a high energy laser pulse (10 J, 1012 W/cm2). Experiments are performed at high repetition rate (1 Hz), which allows one-dimensional and two-dimensional Thomson scattering measurements over an area of several cm2 by automatically translating the scattering volume between shots. Electron temperature and density in the blast wave fronts were seen to increase with increasing background gas pressure. Measured electron density and temperature gradients were used to calculate ∂B/∂t∝∇Te×∇ne. The experimentally measured ∂B/∂t showed agreement with the magnetic field probe (B-dot) measurements, revealing that magnetic fields are generated in the observed blast waves via the Biermann battery effect. The results are compared to numerical three-dimensional collisional magnetohydrodynamic simulations performed with FLASH, and are discussed in the context of spontaneous magnetic field generation via the Biermann battery effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Stars and the Nuclear Matter Equation of State

Neutron stars provide a window into the properties of dense nuclear matter. Several recent observational and theoretical developments provide powerful constraints on their structure and internal composition. Among these are the first observed binary neutron star merger, GW170817, whose gravitational radiation was accompanied by electromagnetic radiation from a short γ-ray burst and an optical afterglow believed to be due to the radioactive decay of newly minted heavy r-process nuclei. These observations give important constraints on the radii of typical neutron stars and on the upper limit to the neutron star maximum mass and complement recent pulsar observations that established a lower limit. Pulse-profile observations by the Neutron Star Interior Composition Explorer (NICER) X-ray telescope provide an independent, consistent measure of the neutron star radius. Theoretical many-body studies of neutron matter reinforce these estimates of neutron star radii. Studies using parameterized dense matter equations of state (EOSs) reveal several EOS-independent relations connecting global neutron star properties.

Physics↗

Ultrafast Martensitic Phase Transition Driven by Intense Terahertz Pulses

We report on an ultrafast nonequilibrium phase transition with a strikingly long-lived martensitic anomaly driven by above-threshold single-cycle terahertz pulses with a peak field of more than 1 MV/cm. A nonthermal, terahertz-induced depletion of low-frequency conductivity in Nb 3 Sn indicates increased gap splitting of high-energy 12 bands by removal of their degeneracies, which induces the martensitic phase above their equilibrium transition temperature. In contrast, optical pumping leads to a Γ 12 gap thermal melting. Such light-induced nonequilibrium martensitic phase exhibits a substantially enhanced critical temperature up to ~100 K, i.e., more than twice the equilibrium temperature, and can be stabilized beyond technologically relevant, nanosecond time scales. Together with first-principle simulations, we identify a compelling terahertz tuning mechanism of structural order via Γ 12 phonons to achieve the ultrafast phase transition to a metastable electronic state out of equilibrium at high temperatures far exceeding those for equilibrium states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗