Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “numerical accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Development and Validation of a Two-Phase Thermal-Hydraulic CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance Computational Fluid Dynamics (CFD) code NEK5000. The goal of this work is to verify and validate the two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) previously developed at Argonne but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2020. This report focuses on verification and validation of the water-steam boiling model NEK-2P Two-Phase, CFD code. The NEK-2P was validated with Nuclear Power Engineering Corporation (NUPEC) Pressurized Water Reactor (PWR) Sub-channel and Bundle Test (PSBT) void distribution benchmark. Three different simulations were performed and analyzed for various operating conditions such as wall-heat flux and sub-cooled inlet temperatures. Reasonably good agreement with measured data was obtained in predicting the measured void distributions. Simulations were performed for Virginia Tech. (VT) 3x3 rod bundle geometry with and without spacers. The preliminary results were presented for Simplified Spacer Grid (SSG). In addition, the implementation of interface reconstruction model was tested with one of the Becker benchmark Critical Heat Flux (CHF) experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Metric Type in the Target-matrix Mesh Optimization Paradigm

The Target Matrix Optimization Paradigm (TMOP) is a method for improving the accuracy, efficiency, and robustness of numerical solutions to partial differential equations by improving the geometric quality of the computational mesh, primarily through node movement. TMOP has been successfully applied to a number applications even though the paradigm was not fully understood at the time. With this work, TMOP can be seen to be a tightly woven fabric of interconnecting ideas and concepts that provides a powerful approach to mesh optimization. The central unifying concepts in TMOP are the concept of a Target Matrix and the concept of Metric Type. Target matrices are motivated by the desire to make mesh quality improvement application-specific and, when needed, solution-adaptive. Metric type plays an essential role because it provides, through the use of typed metrics, the bridge between application-specific quality and target construction. It is shown that there are eight theoretical metric types, including the shape and shape+size types used informally in the past. It is shown further that there exist well-posed metrics corresponding to six of the eight metric types. A well-posed metric is a metric that is typed and convex, polyconvex, or invex, and further, it is a metric that simplifies target construction.

97 MATHEMATICS AND COMPUTING↗

Validation of Computational Fluid Dynamics Simulations for Biological Performance Assessment in Hydropower units (Final Report)

The biological performance assessment (BioPA) toolset developed by Pacific Northwest National Laboratory (PNNL) estimates the relative biological performance of fish passage at a hydroelectric power turbine unit. The tool is based on the use of computational fluid dynamics (CFD) and fish biological response relationships. The recent release, BioPA-v3, is based on directly computed trajectory and collision of material Lagrangian particles using CFD simulation codes rather than the prior version that relies on Tecplot to compute streamtrace trajectories. Before modifying the toolset, a series of validation tests were performed at the various steps of modification in the toolset. Validation is a critical step of any numerical investigation that reflects the accuracy and reliability of the predicted results. It raises the confidence level of the user to use the modified version of the BioPA toolset. Several test cases were simulated and compared, where available, to observed data. The trajectory and collision of the small spherical and cylindrical particles in a water flume were compared to in-house experiments. The CFD predicted collision rate and flow field compared well with experimental observation for vane array and large cylinder as target bodies. Next, the CFD-predicted flow field and hydraulic performance of a laboratory-scale model of a Francis turbine was also successfully validated. Note that the trajectory of the particles is significantly affected by the flow field in such extreme conditions. In addition to the particle trajectories and flow field, the collision detection method employed in the CFD simulations was also successfully validated. The CFD predicted impact velocity, collision time, velocity, and trajectory of a sphere excellently matched with analytical value for a bouncing ball in the elastic collision. A similar approach was also tested and successfully validated for a collision of sphere with a 45° inclined plane. After successfully validating different cases, the BioPA toolset was modified to use direct output of the CFD prediction and the new version can be used in evaluating biological performance at hydroelectric turbines.

13 HYDRO ENERGY↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Novel 'Smart Microchip Proppants' Technology for Precision Diagnostics of Hydraulic Fracture Networks (Edited Final Report)

This project introduces innovative technology to improve subsurface characterization, visualization, and diagnostics of unconventional reservoirs (fossil resources). Through a collaborative effort involving the University of Kansas, UCLA, MicroSilicon Inc., and EOG Resources, the project aims to deliver precision diagnostics for hydraulic fractures using novel high-resolution imaging technology based on smart microchip proppants. Additionally, it seeks to enhance the accuracy and predictability of integrated numerical, and machine-learning modeling techniques for hydraulic fracture characterization and simulation. This groundbreaking technology addresses significant gaps in understanding unconventional and tight reservoir behavior and optimizing well-completion strategies, enabling more cost-efficient recovery of unconventional resources.

02 PETROLEUM↗

The inviscid incompressible limit of Kelvin–Helmholtz instability for plasmas

The Kelvin–Helmholtz Instability (KHI) is an interface instability that develops between two fluids or plasmas flowing with a common shear layer. KHI occurs in astrophysical jets, solar atmosphere, solar flows, cometary tails, planetary magnetospheres. Two applications of interest, encompassing both space and fusion applications, drive this study: KHI formation at the outer flanks of the Earth’s magnetosphere and KHI growth from non-uniform laser heating in magnetized direct-drive implosion experiments. Here, we study 2D KHI with or without a magnetic field parallel to the flow. We use both the GAMERA code, which solves the compressible Euler equations, and the STRATOSPEC code, which solves the Navier-Stokes equations under the Boussinesq approximation, coupled with the magnetic field dynamics. GAMERA is a global three-dimensional MHD code with high-order reconstruction in arbitrary nonorthogonal curvilinear coordinates, which is developed for a large range of astrophysical applications. STRATOSPEC is a three-dimensional pseudo-spectral code with an accuracy of infinite order (no numerical diffusion). Magnetized KHI is a canonical case for benchmarking hydrocode simulations with extended MHD options. An objective is to assess whether or not, and under which conditions, the incompressibility hypothesis allows to describe a dynamic compressible system. For comparing both codes, we reach the inviscid incompressible regime, by decreasing the Mach number in GAMERA, and viscosity and diffusion in STRATOSPEC. Here, we specifically investigate both single-mode and multi-mode initial perturbations, either with or without magnetic field parallel to the flow. The method relies on comparisons of the density fields, 1D profiles of physical quantities averaged along the flow direction, and scale-by-scale spectral densities. We also address the triggering, formation and damping of filamentary structures under varying Mach number or Atwood number, with or without a parallel magnetic field. Comparisons show very satisfactory results between the two codes. The vortices dynamics is well reproduced, along with the breaking or damping of small-scale structures. We end with the extraction of growth rates of magnetized KHI from the compressible regime to the incompressible limit in the linear regime assessing the effects of compressibility under increasing magnetic field. The observed differences between the two codes are explained either from diffusion or non-Boussinesq effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combining machine-learned and empirical force fields with the parareal algorithm: application to the diffusion of atomistic defects

We numerically investigate an adaptive version of the parareal algorithm in the context of molecular dynamics. This adaptive variant has been originally introduced in [1]. We focus here on test cases of physical interest where the dynamics of the system is modelled by the Langevin equation and is simulated using the molecular dynamics software LAMMPS. In this work, the parareal algorithm uses a family of machine-learning spectral neighbor analysis potentials (SNAP) as fine, reference, potentials and embedded-atom method potentials (EAM) as coarse potentials. We consider a self-interstitial atom in a tungsten lattice and compute the average residence time of the system in metastable states. Our numerical results demonstrate significant computational gains using the adaptive parareal algorithm in comparison to a sequential integration of the Langevin dynamics. We also identify a large regime of numerical parameters for which statistical accuracy is reached without being a consequence of trajectorial accuracy.

36 MATERIALS SCIENCE↗

Transient cooling of solid bodies of classical form by radiation

An approximate analytic method is presented for analysis of the unsteady process of radiative cooling of solid bodies of classical form. The nonlinear heat transfer problem is solved by the cascade linearization technique with use of the iteration method. Comparison of the results obtained even in the first approximation with the available numerical solutions indicates adequate engineering accuracy of the proposed technique.

Novikov, V. S.↗

Some self starting integrators for x Prime equals f (x, t)

The integration is discussed of the vector differential equation X = F(x, t) from time t sub i to t sub (i = 1) where only the values of x sub i are available for the the integration. No previous values of x or x prime are used. Using an orbit integration problem, comparisons are made between Taylor series integrators and various types and orders of Runge-Kutta integrators. A fourth order Runge-Kutta type integrator for orbital work is presented, and approximate (there may be no exact) fifth order Runge-Kutta integrators are discussed. Also discussed and compared is a self starting integrator ising delta f/delta x. A numerical method for controlling the accuracy of integration is given, and the special equations for accurately integrating accelerometer data are shown.

Lear, W. M.↗

Structural reanalysis via a mixed method

A study is made of the approximate structural reanalysis technique based on the use of Taylor series expansion of response variables in terms of design variables in conjunction with the mixed method. In addition, comparisons are made with two reanalysis techniques based on the displacement method. These techniques are the Taylor series expansion and the modified reduced basis. It is shown that the use of the reciprocals of the sizing variables as design variables (which is the natural choice in the mixed method) can result in a substantial improvement in the accuracy of the reanalysis technique. Numerical results are presented for a space truss structure.

Noor, A. K.↗

Finite element shell instability analysis

Formulation procedures and the associated computer program for finite element thin shell instability analysis are discussed. Data cover: (1) formulation of basic element relationships, (2) construction of solution algorithms on both the conceptual and algorithmic levels, and (3) conduction of numerical analyses to verify the accuracy and efficiency of the theory and related programs therein are described.

Source record↗

Second-order non-iterative ADI solution of non-linear partial differential equations

A new method for the solution of non-linear partial differential equations by an ADI procedure is described. Although the method is second order accurate in time, it does not require either iterations or predictor corrector methods to overcome the nonlinearity of the equations. Thus the computational effort required for the solution of the non-linear problem becomes similar to that required for the linear case. The method is applied to a two-dimensional 'extended Burgers equation'. Linear stability is studied, and some numerical solutions obtained. The improved accuracy obtained by the 2nd order truncation error is clearly manifested.

Wolfshtein, M.↗

Velocity and temperature distributions of coal-slag layers on magnetohydrodynamic generators walls

Approximate analytical expressions are derived for the velocity and temperature distributions in steady state coal slag deposits flowing over MHD generator walls. Effects of slag condensation and Joule heating are included in the analysis. The transport conditions and the slag temperature at the slag-gas interface are taken to be known parameters in the formulation. They are assumed to have been predetermined either experimentally or from the slag properties and the gas dynamic calculations of the free stream flow. The analysis assumes a power law velocity profile for the slag and accounts for the coupling between the energy and momentum conservation equations. Comparisons are made with the more exact numerical solutions to verify the accuracy of the results.

Pian, C. C. P.↗

The effect of bandwidth on filter instrument total ozone accuracy

The effect of the width and shape of the New Zealand filter instrument's passbands on measured total-ozone accuracy is determined using a numerical model of the spectral measurement process. The model enables the calculation of corrections for the 'bandwidth-effect' error and shows that highly attenuating passband skirts and well-suppressed leakage bands are at least as important as narrow half-bandwidths. Over typical ranges of airmass and total ozone, the range in the bandwidth-effect correction is about 2% in total ozone for the filter instrument, compared with about 1% for the Dobson instrument.

Basher, R. E.↗

An Improved Theoretical Aerodynamic Derivatives Computer Program for Sounding Rockets

The paper outlines a Theoretical Aerodynamic Derivatives (TAD) computer program for computing the aerodynamics of sounding rockets. TAD outputs include normal force, pitching moment and rolling moment coefficient derivatives as well as center-of-pressure locations as a function of the flight Mach number. TAD is applicable to slender finned axisymmetric vehicles at small angles of attack in subsonic and supersonic flows. TAD improvement efforts include extending Mach number regions of applicability, improving accuracy, and replacement of some numerical integration algorithms with closed-form integrations. Key equations used in TAD are summarized and typical TAD outputs are illustrated for a second-stage Tomahawk configuration.

Barrowman, J. S.↗

A generalized vortex lattice method

Several variations of vortex lattice method that are currently available have proved practical and versatile theoretical tools for aerodynamic analysis and design of planar and nonplanar configurations. Success of method is due in great part to relative simplicity of numerical technique involved and to accuracy of results obtained; however, most of available procedures are for subsonic flow applications. VORLAX program was developed to incorporate direct extension of vortex lattice method into supersonic flow regime, thus providing analyst with full flow range capability.

Baker, W. M.↗

Calculation of two-dimensional inlet flow fields in a supersonic free stream by an implicit marching code with nonorthogonal mesh generation: User's manual

An implicit, shock-capturing finite-difference code which is used to calculate two-dimensional inlet flow fields in a supersonic free stream is explained. The Euler equations are subjected to general nonorthogonal transformation and a body-fitted coordinate system is employed. The mathematical formulation of the problem is given along with the numerical algorithm. Initial and boundary conditions, numerical stability, program limitations, and accuracy is discussed. An overall program logic as well as instructions for program use and operation are also furnished.

Biringen, S. H.↗