Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Comparative Toxicity and Dosimetric Profile of Whole-Pelvis Versus Prostate Bed-Only Intensity-Modulated Radiation Therapy After Prostatectomy

Purpose: To assess whether whole-pelvis (WP) intensity modulated radiation therapy (IMRT) for prostate cancer (PCa) after prostatectomy is associated with increased toxicity compared to prostate-bed only (PB) IMRT. Methods and Materials: All patients (n = 67) undergoing postprostatectomy IMRT to 70.2 Gy at our institution from January 2006 to January 2009 with minimum 12-month follow-up were divided into WP (n = 36) and PB (n = 31) comparison groups. WP patients received initial pelvic nodal IMRT to 45 Gy. Pretreatment demographics, bladder and rectal dose-volume histograms, and maximum genitourinary (GU) and gastrointestinal (GI) toxicities were compared. Logistic regression models evaluated uni- and multivariate associations between pretreatment demographics and toxicities. Results: Pretreatment demographics including age and comorbidities were similar between groups. WP patients had higher Gleason scores, T stages, and preoperative prostate-specific antigen (PSA) levels, and more WP patients underwent androgen deprivation therapy (ADT). WP minimum (Dmin) and mean bladder doses, bladder volumes receiving more than 5 Gy (V5) and V20, rectal Dmin, and PB bladder and rectal V65 were significantly increased. Maximum acute GI toxicity was Grade 2 and was increased for WP (61%) vs. PB (29%) patients (p = 0.001); there was no significant difference in acute Grade {>=}2 GU toxicity (22% WP vs. 10% PB; p = 0.193), late Grade {>=}2 GI toxicity (3% WP vs. 0% PB; p = 0.678), or late Grade {>=}2 GU toxicity (28% WP vs. 19% PB; p = 0.274) with 25-month median follow-up (range, 12-44 months). On multivariate analysis, long-term ADT use was associated with Grade {>=}2 late GU toxicity (p = 0.02). Conclusion: Despite dosimetric differences in irradiated bowel, bladder, and rectum, WP IMRT resulted only in clinically significant increased acute GI toxicity in comparison to that with PB IMRT, with no differences in GU or late GI toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron Emission Tomography/Computed Tomography Imaging of Residual Skull Base Chordoma Before Radiotherapy Using Fluoromisonidazole and Fluorodeoxyglucose: Potential Consequences for Dose Painting

Purpose: To detect the presence of hypoxic tissue, which is known to increase the radioresistant phenotype, by its uptake of fluoromisonidazole (18F) (FMISO) using hybrid positron emission tomography/computed tomography (PET/CT) imaging, and to compare it with the glucose-avid tumor tissue imaged with fluorodeoxyglucose (18F) (FDG), in residual postsurgical skull base chordoma scheduled for radiotherapy. Patients and Methods: Seven patients with incompletely resected skull base chordomas were planned for high-dose radiotherapy (dose {>=}70 Gy). All 7 patients underwent FDG and FMISO PET/CT. Images were analyzed qualitatively by visual examination and semiquantitatively by computing the ratio of the maximal standardized uptake value (SUVmax) of the tumor and cerebellum (T/C R), with delineation of lesions on conventional imaging. Results: Of the eight lesion sites imaged with FDG PET/CT, only one was visible, whereas seven of nine lesions were visible on FMISO PET/CT. The median SUVmax in the tumor area was 2.8 g/mL (minimum 2.1; maximum 3.5) for FDG and 0.83 g/mL (minimum 0.3; maximum 1.2) for FMISO. The T/C R values ranged between 0.30 and 0.63 for FDG (median, 0.41) and between 0.75 and 2.20 for FMISO (median,1.59). FMISO T/C R >1 in six lesions suggested the presence of hypoxic tissue. There was no correlation between FMISO and FDG uptake in individual chordomas (r = 0.18, p = 0.7). Conclusion: FMISO PET/CT enables imaging of the hypoxic component in residual chordomas. In the future, it could help to better define boosted volumes for irradiation and to overcome the radioresistance of these lesions. No relationship was founded between hypoxia and glucose metabolism in these tumors after initial surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective Cohort Study of Bronchial Doses and Radiation-Induced Atelectasis After Stereotactic Body Radiation Therapy of Lung Tumors Located Close to the Bronchial Tree

Purpose: To evaluate the dose–response relationship between radiation-induced atelectasis after stereotactic body radiation therapy (SBRT) and bronchial dose. Methods and Materials: Seventy-four patients treated with SBRT for tumors close to main, lobar, or segmental bronchi were selected. The association between incidence of atelectasis and bronchial dose parameters (maximum point-dose and minimum dose to the high-dose bronchial volume [ranging from 0.1 cm{sup 3} up to 2.0 cm{sup 3}]) was statistically evaluated with survival analysis models. Results: Prescribed doses varied between 4 and 20 Gy per fraction in 2-5 fractions. Eighteen patients (24.3%) developed atelectasis considered to be radiation-induced. Statistical analysis showed a significant correlation between the incidence of radiation-induced atelectasis and minimum dose to the high-dose bronchial volumes, of which 0.1 cm{sup 3} (D{sub 0.1cm3}) was used for further analysis. The median value of D{sub 0.1cm3} (α/β = 3 Gy) was EQD{sub 2,LQ} = 147 Gy{sub 3} (range, 20-293 Gy{sub 3}). For patients who developed atelectasis the median value was EQD{sub 2,LQ} = 210 Gy{sub 3}, and for patients who did not develop atelectasis, EQD{sub 2,LQ} = 105 Gy{sub 3}. Median time from treatment to development of atelectasis was 8.0 months (range, 1.1-30.1 months). Conclusion: In this retrospective study a significant dose–response relationship between the incidence of atelectasis and the dose to the high-dose volume of the bronchi is shown.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Combined Effect of Radiation Therapy and Hyperthermia in Terms of Equivalent Dose Distributions

Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy{sup −1}) and β (Gy{sup −2}) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normal tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm{sup 3} of the gross tumor volume (D{sub 0.03cc}) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V{sub 100%}) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would benefit from real-time prostate tracking to reduce the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Escalated Liver Stereotactic Body Radiation Therapy at the Mean Respiratory Position

Purpose: The dosimetric impact of dose probability based planning target volume (PTV) margins for liver cancer patients receiving stereotactic body radiation therapy (SBRT) was compared with standard PTV based on the internal target volume (ITV). Plan robustness was evaluated by accumulating the treatment dose to ensure delivery of the intended plan. Methods and Materials: Twenty patients planned on exhale CT for 27 to 50 Gy in 6 fractions using an ITV-based PTV and treated free-breathing were retrospectively evaluated. Isotoxic, dose escalated plans were created on midposition computed tomography (CT), representing the mean breathing position, using a dose probability PTV. The delivered doses were accumulated using biomechanical deformable registration of the daily cone beam CT based on liver targeting at the exhale or mean breathing position, for the exhale and midposition CT plans, respectively. Results: The dose probability PTVs were on average 38% smaller than the ITV-based PTV, enabling an average ± standard deviation increase in the planned dose to 95% of the PTV of 4.0 ± 2.8 Gy (9 ± 5%) on the midposition CT (P<.01). For both plans, the delivered minimum gross tumor volume (GTV) doses were greater than the planned nominal prescribed dose in all 20 patients and greater than the planned dose to 95% of the PTV in 18 (90%) patients. Nine patients (45%) had 1 or more GTVs with a delivered minimum dose more than 5 Gy higher with the midposition CT plan using dose probability PTV, compared with the delivered dose with the exhale CT plan using ITV-based PTV. Conclusions: For isotoxic liver SBRT planned and delivered at the mean respiratory, reduced dose probability PTV enables a mean escalation of 4 Gy (9%) in 6 fractions over ITV-based PTV. This may potentially improve local control without increasing the risk of tumor underdosing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Urinary Side Effects 10 Years After Low-Dose-Rate Prostate Brachytherapy: Population-Based Results From a Multiphysician Practice Treating With a Standardized Protocol and Uniform Dosimetric Goals

Purpose: To determine late urinary toxicity (>12 months) in a large cohort of uniformly treated low-dose-rate prostate brachytherapy patients. Methods and Materials: From 1998 to 2009, 2709 patients with National Comprehensive Cancer Network–defined low-risk and low-tier intermediate-risk prostate cancer were treated with Iodine 125 ({sup 125}I) low-dose-rate prostate brachytherapy; 2011 patients with a minimum of 25 months of follow-up were included in the study. Baseline patients, treatment, implant factors, and late urinary toxicity (Radiation Therapy Oncology Group [RTOG] grading system and International Prostate Symptom Score [IPSS]) were recorded prospectively. Time to IPSS resolution, late RTOG genitourinary toxicity was examined with Kaplan-Meier and log-rank tests. Cox proportional hazards regression was done for individual covariates and multivariable models. Results: Median follow-up was 54.5 months (range, 2-13 years). Actuarial toxicity rates reached 27% and 10% (RTOG ≥2 and ≥3, respectively) at 9-13 years. Symptoms resolved quickly in the majority of patients (88% in 6-12 months). The prevalence of RTOG 0, 1, 2, 3, and 4 toxicity with a minimum of 7 years' follow-up was 70%, 21%, 6.4%, 2.3%, and 0.08%, respectively. Patients with a larger prostate volume, higher baseline IPSS, higher D90, acute toxicity, and age >70 years had more late RTOG ≥2 toxicity (all P≤.02). The IPSS resolved slower in patients with lower baseline IPSS and larger ultrasound prostate volume, those not receiving androgen deprivation therapy, and those with higher D90. The crude rate of RTOG 3 toxicity was 6%. Overall the rate of transurethral resection of the prostate was 1.9%; strictures, 2%; incontinence, 1.3%; severe symptoms, 1.8%; late catheterization, 1.3%; and hematuria, 0.8%. The majority (80%) resolved their symptoms in 6-12 months. Conclusion: Long-term urinary toxicity after brachytherapy is low. Although actuarial rates increase with longer follow-up (27% RTOG 2 and 10% RTOG 3 at 13 years), symptoms resolve relatively quickly; between 5 and 13 years' follow-up, >90% of patients have minimal urinary toxicity. Refining patient selection criteria, planning, and treatment delivery may further reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Ablative Body Radiation Therapy for Primary Kidney Cancer: A 3-Dimensional Conformal Technique Associated With Low Rates of Early Toxicity

Purpose: To describe our 3-dimensional conformal planning approaches and report early toxicities with stereotactic body radiation therapy for the management of primary renal cell carcinoma. Methods and Materials: This is an analysis of a phase 1 trial of stereotactic body radiation therapy for primary inoperable renal cell carcinoma. A dose of 42 Gy/3 fractions was prescribed to targets ≥5 cm, whereas for <5 cm 26 Gy/1 fraction was used. All patients underwent a planning 4-dimensional CT to generate a planning target volume (PTV) from a 5-mm isotropic expansion of the internal target volume. Planning required a minimum of 8 fields prescribing to the minimum isodose surrounding the PTV. Intermediate dose spillage at 50% of the prescription dose (R50%) was measured to describe the dose gradient. Early toxicity (<6 months) was scored using the Common Terminology Criteria for Adverse Events (v4.0). Results: From July 2012 to August 2013 a total of 20 patients (median age, 77 years) were recruited into a prospective clinical trial. Eleven patients underwent fractionated treatment and 9 patients a single fraction. For PTV targets <100 cm{sup 3} the median number of beams used was 8 (2 noncoplanar) to achieve an average R50% of 3.7. For PTV targets >100 cm{sup 3} the median beam number used was 10 (4 noncoplanar) for an average R50% value of 4.3. The R50% was inversely proportional to decreasing PTV volume (r=−0.62, P=.003) and increasing total beams used (r=−0.51, P=.022). Twelve of 20 patients (60%) suffered grade ≤2 early toxicity, whereas 8 of 20 patients (40%) were asymptomatic. Nausea, chest wall pain, and fatigue were the most common toxicities reported. Conclusion: A 3-dimensional conformal planning technique of 8-10 beams can be used to deliver highly tolerable stereotactic ablation to primary kidney targets with minimal early toxicities. Ongoing follow-up is currently in place to assess long-term toxicities and cancer control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° were corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accumulated Delivered Dose Response of Stereotactic Body Radiation Therapy for Liver Metastases

Purpose: To determine whether the accumulated dose using image guided radiation therapy is a stronger predictor of clinical outcomes than the planned dose in stereotactic body radiation therapy (SBRT) for liver metastases. Methods and Materials: From 2003 to 2009, 81 patients with 142 metastases were treated in institutional review board–approved SBRT studies (5-10 fractions). Patients were treated during free breathing (with or without abdominal compression) or with controlled exhale breath-holding. SBRT was planned on a static exhale computed tomography (CT) scan, and the minimum planning target volume dose to 0.5 cm{sup 3} (minPTV) was recorded. The accumulated minimum dose to the 0.5 cm{sup 3} gross tumor volume (accGTV) was calculated after performing dose accumulation from exported image guided radiation therapy data sets registered to the planning CT using rigid (2-dimensional MV/kV orthogonal) or deformable (3-dimensional/4-dimensional cone beam CT) image registration. Univariate and multivariate Cox regression models assessed the factors influencing the time to local progression (TTLP). Hazard ratios for accGTV and minPTV were compared using model goodness-of-fit and bootstrapping. Results: Overall, the accGTV dose exceeded the minPTV dose in 98% of the lesions. For 5 to 6 fractions, accGTV doses of >45 Gy were associated with 1-year local control of 86%. On univariate analysis, the cancer subtype (breast), smaller tumor volume, and increased dose were significant predictors for improved TTLP. The dose and volume were uncorrelated; the accGTV dose and minPTV dose were correlated and were tested separately on multivariate models. Breast cancer subtype, accGTV dose (P<.001), and minPTV dose (P=.02) retained significance in the multivariate models. The univariate hazard ratio for TTLP for 5-Gy increases in accGTV versus minPTV was 0.67 versus 0.74 (all patients; 95% confidence interval of difference 0.03-0.14). Goodness-of-fit testing confirmed the accGTV dose as a stronger dose–response predictor than the minPTV dose. Conclusions: The accGTV dose is a better predictor of TTLP than the minPTV dose for liver metastasis SBRT. The use of modern image guided radiation therapy in future analyses of dose–response outcomes should increase the concordance between the planned and delivered doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High resolution finite volume scheme for the quantum hydrodynamic equations

The theory of quantum fluid dynamics (QFD) helps nanotechnology engineers to understand the physical effect of quantum forces. Although the governing equations of quantum fluid dynamics and classical fluid mechanics have the same form, there are two numerical simulation problems must be solved in QFD. The first is that the quantum potential term becomes singular and causes a divergence in the numerical simulation when the probability density is very small and close to zero. The second is that the unitarity in the time evolution of the quantum wave packet is significant. Accurate numerical evaluations are critical to the simulations of the flow fields that are generated by various quantum fluid systems. A finite volume scheme is developed herein to solve the quantum hydrodynamic equations of motion, which significantly improve the accuracy and stability of this method. The QFD equation is numerically implemented within the Eulerian method. A third-order modified Osher-Chakravarthy (MOC) upwind-centered finite volume scheme was constructed for conservation law to evaluate the convective terms, and a second-order central finite volume scheme was used to map the quantum potential field. An explicit Runge-Kutta method is used to perform the time integration to achieve fast convergence of the proposed scheme. In order to meet the numerical result can conform to the physical phenomenon and avoid numerical divergence happening due to extremely low probability density, the minimum value setting of probability density must exceed zero and smaller than certain value. The optimal value was found in the proposed numerical approach to maintain a converging numerical simulation when the minimum probability density is 10{sup -5} to 10{sup -12}. The normalization of the wave packet remains close to unity through a long numerical simulation and the deviations from 1.0 is about 10{sup -4}. To check the QFD finite difference numerical computations, one- and two-dimensional particle motions were solved for an Eckart barrier and a downhill ramp barrier, respectively. The results were compared to the solution of the Schroedinger equation, using the same potentials, which was obtained using by a finite difference method. Finally, the new approach was applied to simulate a quantum nanojet system and offer more intact theory in quantum computational fluid dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved performance comparisons of radioxenon systems for low level releases in nuclear explosion monitoring

The Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests and mandates development of verification measures to detect treaty violations. One verification measure is detection of radioactive xenon isotopes produced in the fission of actinides. The International Monitoring System (IMS) currently deploys automated radioxenon systems that can detect four radioxenon isotopes. Radioxenon systems with lower detection limits are currently in development. Historically, the sensitivity of radioxenon systems was measured by the minimum detectable concentration for each isotope. In this paper we analyze the response of radioxenon systems using rigorous metrics in conjunction with hypothetical representative releases indicative of an underground nuclear explosion instead of using only minimum detectable concentrations. Our analyses incorporate the impact of potential spectral interferences on detection limits and the importance of measuring isotopic ratios of the relevant radioxenon isotopes in order to improve discrimination from background sources particularly for low-level releases. To provide a sufficient data set for analysis, hypothetical representative releases are simulated every day from the same location for an entire year. The performance of three types of samplers are evaluated assuming they are located at 15 IMS radionuclide stations in the region of the release point. The performance of two IMS-deployed samplers and a next-generation system is compared with proposed metrics for detection and discrimination using representative releases from the nuclear test site used by the Democratic People’s Republic of Korea.

Haas, Derek A.↗

Third international challenge to model the medium- to long-range transport of radioxenon to four Comprehensive Nuclear-Test-Ban Treaty monitoring stations

In 2015 and 2016, atmospheric transport modeling challenges were conducted in the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) verification, however, with a more limited scope with respect to emission inventories, simulation period and number of relevant samples (i.e., those above the Minimum Detectable Concentration (MDC)) involved. Therefore, a more comprehensive atmospheric transport modeling challenge was organized in 2019. Stack release data of Xe-133 were provided by the Institut National des Radioéléments/IRE (Belgium) and the Canadian Nuclear Laboratories/CNL (Canada) and accounted for in the simulations over a three (mandatory) or six (optional) months period. Best estimate emissions of additional facilities (radiopharmaceutical production and nuclear research facilities, commercial reactors or relevant research reactors) of the Northern Hemisphere were included as well. Model results were compared with observed atmospheric activity concentrations at four International Monitoring System (IMS) stations located in Europe and North America with overall considerable influence of IRE and/or CNL emissions for evaluation of the participants’ runs. Participants were prompted to work with controlled and harmonized model set-ups to make runs more comparable, but also to increase diversity. It was found that using the stack emissions of IRE and CNL with daily resolution does not lead to better results than disaggregating annual emissions of these two facilities taken from the literature if an overall score for all stations covering all valid observed samples is considered. A moderate benefit of roughly 10% is visible in statistical scores for samples influenced by IRE and/or CNL to at least 50% and there can be considerable benefit for individual samples. Effects of transport errors, not properly characterized remaining emitters and long IMS sampling times (12–24 h) undoubtedly are in contrast to and reduce the benefit of high-quality IRE and CNL stack data. Complementary best estimates for remaining emitters push the scores up by 18% compared to just considering IRE and CNL emissions alone. Despite the efforts undertaken the full multi-model ensemble built is highly redundant. An ensemble based on a few arbitrary runs is sufficient to model the Xe-133 background at the stations investigated. The effective ensemble size is below five. An optimized ensemble at each station has on average slightly higher skill compared to the full ensemble. However, the improvement (maximum of 20% and minimum of 3% in RMSE) in skill is likely being too small for being exploited for an independent period.

54 ENVIRONMENTAL SCIENCES↗

Historical trends and extremes in boreal Alaska river basins

Climate change will shift the frequency, intensity, duration and persistence of extreme hydroclimate events and have particularly disastrous consequences in vulnerable systems such as the warm permafrost-dominated Interior region of boreal Alaska. This work focuses on recent research results from nonparametric trends and nonstationary generalized extreme value (GEV) analyses at eight Interior Alaskan river basins for the past 50/60 years (1954/64–2013). Trends analysis of maximum and minimum streamflow indicates a strong (>+50%) and statistically significant increase in 11-day flow events during the late fall/winter and during the snowmelt period (late April/mid-May), followed by a significant decrease in the 11-day flow events during the post-snowmelt period (late May and into the summer). The April–May–June seasonal trends show significant decreases in maximum streamflow for snowmelt dominated systems (<–50%) and glacially influenced basins (–24% to –33%). Annual maximum streamflow trends indicate that most systems are experiencing declines, while minimum flow trends are largely increasing. Nonstationary GEV analysis identifies time-dependent changes in the distribution of spring extremes for snowmelt dominated and glacially dominated systems. Temperature in spring influences the glacial and high elevation snowmelt systems and winter precipitation drives changes in the snowmelt dominated basins. The Pacific Decadal Oscillation was associated with changes occurring in snowmelt dominated systems, and the Arctic Oscillation was linked to one lake dominated basin, with half of the basins exhibiting no change in response to climate variability. The paper indicates that broad scale studies examining trend and direction of change should employ multiple methods across various scales and consider regime dependent shifts to identify and understand changes in extreme streamflow within boreal forested watersheds of Alaska.

54 ENVIRONMENTAL SCIENCES↗

Review of condensed matter laser cooling using electric-dipole-allowed transitions

The cooling of solids via laser-excited anti-Stokes luminescence has reached the cryogenic regime and is now being considered for several applications that benefit from vibration-free cryogenic refrigeration. 4f-4f transitions in rare-earth-doped crystals with low phonon energies currently offer the best laser-cooling performance. These transitions, however, are electric-dipole (ED) forbidden and thus have low cross sections, limiting the minimum achievable temperatures in practical materials to the 50–100 K regime. In contrast, ED-allowed transitions may offer greater cross sections and potentially enable lower minimum temperatures or more compact devices. The search for laser cooling with ED-allowed transitions has been an active field of research over the past decades with a wide variety of materials having been studied. This paper reviews the fundamentals of solid-state laser cooling, provides a preliminary theoretical assessment showing that laser-cooling with ED-allowed transitions is in principle possible, and reviews the experimental results reported to date. While cooling with ED-allowed transitions has not yet been realized in the solid state, the existing experimental body of work along with the theoretical considerations presented here suggest that further research on this topic may be fruitful.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Inconel 625 fabricated using powder-bed-based additive manufacturing technologies

The purpose of this study was to perform a comparative analysis of powder-bed-based additive manufacturing (AM) technologies during the production of metallic components using Inconel 625 powder material. The AM technologies explored in this study include electron beam powder bed fusion (EPBF), laser powder bed fusion (LPBF), and binder jetting technology. Samples were fabricated in two build directions (X and Z build orientations) for this evaluation process, where all specimens underwent a hot isostatic pressing (HIP) post-process. The comparison was made in terms of microstructure and mechanical properties including ultimate tensile strength (UTS), yield strength (YS), percent elongation, and modulus of elasticity (E). Microstructural characterization showed evidence of equiaxed grain formation for binder jetting and LPBF parts, whereas EPBF parts displayed a more columnar grain formation parallel to the build direction. Six specimens were tested per technology, three built in the X orientation and three built in the Z orientation. All six specimens were built in a single run of each AM machine. Results indicated that all three technologies are capable of meeting the minimum requirements of the ASTM F3056-14 standard for parts produced in the X orientation, with properties that are similar to wrought Inconel 625. In the Z orientation, however, only LPBF was able to meet the minimum standard requirements. Through the comparative analysis of the mechanical properties, here this work showed that LPBF outperformed the other technologies in a majority of the evaluated properties, followed by EPBF and binder jetting. An analysis of the fracture surfaces of tensile specimens was also performed, and it indicated ductile fracture (dimple rupture) for the specimens produced with all three of the AM technologies studied. Nevertheless, the characterization also showed certain differences in the fractured surfaces, such as the presence of un-sintered powder particles for the binder jetting processed Inconel 625, or the development of the so called woody structure for the EPBF processed material. This study can be used to determine distinct characteristics between the three powder-bed-based technologies for the fabrication of Inconel 625 that can further include other technologies and materials using similar approaches.

36 MATERIALS SCIENCE↗

Anomalously strong viscosity behavior in mixed oxy-sulfide Na 4 P 2 S 7-x O x invert glasses

In this paper, the first observations have been made of anomalously strong viscosity behavior and correspondingly strong bulk glass formation and resistance to crystallization in a melt quenched (MQ) prepared series of invert, modifier content greater than the glass former content, mixed oxy-sulfide Na 4 P 2 S 7-x O x , 0 ≤ x ≤ 5, (NaPSO) glasses. We find that these glasses even with 67 mole % modifier, Na 2 S, and only 33 mole% glass former P 2 S 5-x O x , exhibit a calorimetric fragility index, m cal , as small as 29 compared to typical values of ~ 60 to 80 for alkali silicate glasses with > 50 mole% SiO 2 and the theoretical minimum m cal of ~ 15. The m cal values were converted to kinetic viscosity fragility, m vis , values and used with the measured glass transition temperatures, T g s, to produce viscosity curves for the glasses using the Mauro-Yue-Ellison-Gupta-Allan (MYEGA) model. The viscosity of the glass with a minimum m cal value of x = 2.5 was then shown to exhibit a viscosity that was as strong as, and for some compositions stronger than, the viscosity of alkali aluminosilicate glasses which have three dimensional network structures compared to the one dimensional chain structures observed in these MOS invert glasses. Consistent with these small values of fragility indices and therefore predicted higher viscosity above the glass transition temperature, T g , in the supercooled liquid regime, these glasses are also particularly resistant to crystallization. For example, the x = 2.5 glass composition exhibits a crystallization temperature, T C , more than 150K above its T g . We find that the calorimetric fragility of these glasses varies systematically with the extent of network forming bridging oxygens (BOs) in the glasses. The structural change caused by incrementally replacing sulfur with oxygen has been found to have consistent, large effects on the thermal properties.

36 MATERIALS SCIENCE↗

Ab initio molecular dynamics simulations of low energy recoil events in MgO

In this paper, low-energy recoil events in MgO are studied using ab initio molecular dynamics simulations to reveal the dynamic displacement processes and final defect configurations. Threshold displacement energies, E d , are obtained for Mg and O along three low-index crystallographic directions, [100], [110], and [111]. The minimum values for E d are found along the [110] direction consisting of the same element, either Mg or O atoms. Minimum threshold values of 29.5 eV for Mg and 25.5 eV for O, respectively, are suggested from the calculations. For other directions, the threshold energies are considerably higher, 65.5 and 150.0 eV for O along [111] and [100], and 122.5 eV for Mg along both [111] and [100] directions, respectively. These results show that the recoil events in MgO are partial-charge transfer assisted processes where the charge transfer plays an important role. Finally, there is a similar trend found in other oxide materials, where the threshold displacement energy correlates linearly with the peak partial-charge transfer, suggesting this behavior might be universal in ceramic oxides.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗