Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnet test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

The new MSFC Solar vector magnetograph. Center director's discretionary fund

The unique MSFC solar vector magnetograph allows measurements of all three components of the Sun's photospheric magnetic field over a wide field-of-view with spatial resolution determined by a 2.7 x 2.7 arc second pixel size. This system underwent extensive modifications to improve its sensitivity and temporal response. The modifications included replacing an SEC vidicon detector with a solid-state CCD camera; replacing the original digital logic circuitry with an electronic controller and a computer to provide complete, programmable control over the entire operation of the magnetograph; and installing a new polarimeter which consists of a single electro-optical modulator coupled with interchangeable waveplates mounted on a rotating assembly. The system is described and results of calibrations and tests are presented. Initial observations of solar magnetic fields with the new magnetograph are presented.

Hagyard, M. J.↗

Flex-PCB Quench Antenna Developments at FNAL

We report flexible printed-circuit-board-based quench antenna arrays have been developed at FNAL since 2017. They proved to be low-noise, low-cost, sensitive, and non-invasive sensors for quench characterization in superconducting magnets, having the potential to extend even to quench detection. Starting with applications of small area sensors of this type, we have explored feasibility for operations at high pressure, and have invested in multi-channel quench antenna arrays covering the complete area of the innermost magnet layer of the conductor. We've also tested and optimized sensor geometry and relative orientations to increase sensitivity and spatial resolution. Beyond developments of warm and cold bore antennas, we've progressed to concepts which attach quench antennas to the conductor surfaces of accelerator magnets. Multiple programs and projects at FNAL and collaborating institutions benefited from this work already and our plans target further extensions of capabilities and applicability of these devices. In this paper we present the logic behind the development steps taken so far, status of our work and direction of near-term research on quench antennas at Fermilab.

43 PARTICLE ACCELERATORS↗

Magnetoelectrostatic thruster physical geometry tests

Inert gas tests are conducted with several magnetoelectrostatic containment discharge chamber geometries. The configurations tested include three discharge chamber lengths; three boundary magnet patterns; two different flux density magnet materials; hemispherical and conical shaped thrusters having different surface-to-volume ratios; and two and three grid ion optics. Argon mass utilizations of 60 to 79% are attained at 210 to 280 eV/ion in different test configurations. Short hemi thruster configurations are found to produce 70 to 92% xenon mass utilization at 185 to 220 eV/ion.

Ramsey, W. D.↗

An experimental study to investigate magnetic field and winding force-dependent contact resistance of NI REBCO coil

Abstract This paper reports the magnetic field and winding force-dependent contact resistance, also known as characteristic resistance, of no-insulation (NI) REBCO coil. Three NI coils were wound with different winding forces ( < 1 kgf, 3 kgf, and 5 kgf) using the same REBCO-coated conductor, and they were tested at 4.2 K in a background field of 0, 5, 10, and 14 T. The contact resistance of each coil is measured at each field. As a result of the measurements, we draw two conclusions. First, a quadratic function for magnetic field intensity reasonably reproduces the measurement results of each NI test coil’s magnetic field-dependent contact resistance, where the practical fit function’s coefficients are determined depending on the winding force. Second, the contact resistance of each coil is partially inconsistent with the magnetoresistance of the electroplated material, i.e. copper, of the REBCO-coated conductor. This paper will present the measurement results in detail, discuss them with Kohler’s rule, and formulate the contact resistance using winding force and magnetic field terms.

Bang, Jeseok (ORCID:0000000247616334)↗

Investigating Material Properties of Subsurface Rock Formations Modified by Engineering Mineral Precipitation (Final Scientific and Technical Report)

Montana State University’s (MSU) Energy Research Institute (ERI), in collaboration with the Center for Biofilm Engineering (CBE) and the Department of Civil Engineering (CE), has conducted a long‐term research program aimed at developing a novel cementing agent to address wellbore integrity and reduce the unwanted upward migration of fluids and greenhouse gases from the subsurface. The primary technology developed through this research program is known as ureolysis‐induced calcite precipitation (UICP), which harnesses bio‐chemical processes to precipitate calcium carbonate (CaCO 3 ). The same general process can also be called microbially-induced calcium carbonate precipitation (MICP) when microbes provide the process-catalyzing urease enzyme. Both terms are used in this report. Results have conclusively demonstrated that, if properly controlled, UICP can successfully seal fractures, high permeability zones, and compromised cement in the vicinity of wellbores and in nearby caprock. This technology has been successfully deployed to mitigate annular leakage in two test wells and over sixty commercial wells with a 100% success rate. This success in downhole deployment generates consideration of other subsurface applications where UICP could provide benefit to the energy sector, such as shale property modification for unconventional oil and gas recovery. The focus of this research project was to investigate fundamental material and mechanical properties of select shale cores and analyze how these properties change due to engineered mineral precipitation with the intent to control these properties to achieve a range of engineering objectives. Ultimately, the project aim was to identify valuable new areas where application of UICP might contribute to national energy security and environmental protection. The research workplan coupled UICP treatment of core samples, nuclear magnetic resonance (NMR) characterization, and mechanical strength testing at MSU with advanced X‐Ray micro-computed tomography (μCT) imaging and numerical modeling performed by collaborators at two national laboratories, the National Energy Technology Laboratory (NETL) and Lawrence Berkeley National Laboratory (LBNL). Experimental results are useful to inform geo-mechanical models which could be applied to predict mineralized rock formation behavior at field scale. Our findings suggest that NMR and μCT methods to detect and quantify biomineral formation in shale fractures are complementary and consistent with each other. Either could be used to estimate the volume of new mineral formed by UICP in shale fractures. The use of surfactants and guar gum to enhance biomineral precipitation in shale fractures merits further research. UICP can, under some conditions, increase the tensile strength of sealed shale fractures beyond that of the intact shale. These findings demonstrate that continued research in this area may be valuable to understanding and improving shale resource recovery techniques.

58 GEOSCIENCES↗

The Statistical Mechanics of Solar Wind Hydroxylation at the Moon, Within Lunar Magnetic Anomalies, and at Phobos

We present a new formalism to describe the outgassing of hydrogen initially implanted by the solar wind protons into exposed soils on airless bodies. The formalism applies a statistical mechanics approach similar to that applied recently to molecular adsorption onto activated surfaces. The key element enabling this formalism is the recognition that the interatomic potential between the implanted H and regolith-residing oxides is not of singular value but possess a distribution of trapped energy values at a given temperature, F(U,T). All subsequent derivations of the outward diffusion and H retention rely on the specific properties of this distribution. We find that solar wind hydrogen can be retained if there are sites in the implantation layer with activation energy values exceeding 0.5eV. We especially examine the dependence of H retention applying characteristic energy values found previously for irradiated silica and mature lunar samples. We also apply the formalism to two cases that differ from the typical solar wind implantation at the Moon. First, we test for a case of implantation in magnetic anomaly regions where significantly lower-energy ions of solar wind origin are expected to be incident with the surface. In magnetic anomalies, H retention is found to be reduced due to the reduced ion flux and shallower depth of implantation. Second, we also apply the model to Phobos where the surface temperature range is not as extreme as the Moon. We find the H atom retention in this second case is higher than the lunar case due to the reduced thermal extremes (that reduces outgassing).

Solar Wind↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 micrometers in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 micrometers or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Electric Propulsion↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 μm in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 μm or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Rohit Shastry↗

Cryo-quenched Fe–Ni–Cr alloy decorative steel single crystals II: Alloy phases, structure, hardness, tensile, tribological, magnetic and electronic properties

We have previously reported (Boatner et al., J. Alloys Compd. 691 (2017) 666–671) on the discovery, formation, processing, and application of a new decorative ternary steel alloy and on its use in a wide range of practical applications including: custom and commercial knives, art objects, jewelry, electronics, and furniture. This decorative property results when polished single crystals of the 70 wt%Fe-15 wt%Ni-15 wt% Cr austenitic alloy are cryo-quenched into the martensitic phase resulting in the formation of a three-dimensional raised pattern of mixed austenitic/martensitic laths. These laths propagate across large dimensions of the material due to the absence of grain boundaries in the single crystal. The macroscopic optically reflective 3-D decorative pattern reproduces the structural symmetry inherent in the single-crystal orientation. This pattern results solely from the metallurgical phase properties of the ternary alloy and is completely distinct from the properties of Damascus steels or more modern so-called pattern-welded steels. Here we use X-ray diffraction, nanoindentation, hardness measurements/scratch testing, tribological measurements, and alloy resistivity and magnetization methods to obtain a more fundamental and comprehensive study of the effects of the austenitic/martensitic phase transition on the structural and physical properties of the 70 wt%Fe-15 wt%Ni-15 wt% Cr alloy. These results reveal new insight into irreversible phenomena that are associated with the inhibited phase transition on heating of the two-phase, mixed austenitic/martensitic structure that is formed subsequent to cryo-quenching the alloy crystal to 77 K.

36 MATERIALS SCIENCE↗

Computer Aided Modeling to Determine the Effectiveness of Resistive Exercises as Countermeasures for Bone Mineral Density Loss

Due to the loss of gravitational loading, astronauts have a tendency to lose bone mineral density in their lumbar spine and lower extremities on orbit. NASA requires astronauts to perform exercises during space flight to help reduce the amount of demineralization. To test these exercises on earth, 17 week bed rest studies are conducted that consist of specific diet and exercise regimes. Developing a finite element model of these exercises will help to quantify the stress distribution imposed by of each of these exercises. To help develop this model, MRI images are acquired from individuals participating in the bed rest studies. The MRIs can be used to create a subject specific model of each individual for testing. The MRIs are processed in the Magnetic Resonance Imaging Data Transfer System program to develop a three-dimensional finite element model of the femur for evaluation. Modifications were made to the MRIDTS that simplified the model creation process. These modifications made it possible to construct two separate models of different portions of a bone simultaneously and then later connect them manually. This helped alleviate the warping problem associated with the drastic changes in geometry found in some body parts, such as the joints. The code was also modified to incorporate material properties of various bone components into the model. Interior meshing was also incorporated into the program to allow for both the cortical shell and the entire bone to be modeled. A prototype model of the right femur of an adult female is being constructed and tested to determine the feasibility of finite element analysis as a tool for evaluating exercise effectiveness. The model is being run through the ANSYS finite element program on the Alabama Super Computer Network. After the model is validated, models of bedrest subjects can be generated to investigate exercise countermeasures.

Murphy, Benjamin M.↗

Viking magnetic properties experiment - Extended mission results

The backhoe magnets on Viking Lander (VL) 2 were successfully cleaned, followed by a test involving successive insertions of the cleaned backhoe into the surface. Rapid saturation of the magnets confirmed evidence from primary mission results that the magnetic mineral in the Martian surface is widely distributed, most probably in the form of composite particles of magnetic and nonmagnetic minerals. An image of the VL 2 backhoe taken via the X4 magnifying mirror demonstrates the fine-grained nature of the attracted magnetic material. The presence of maghemite and its occurrence as a pigment in, or a thin coating on, all mineral particles or as discrete, finely divided and widely distributed crystallites, are consistent with data from the inorganic analysis experiments and with laboratory simulations of results of the biology experiments on Mars.

Hargraves, R. B.↗

Effects of magnetic field assisted heat treatment on the microstructure and mechanical properties of Fe-0.63 %C alloy

This study investigates the influence of an applied magnetic field on the microstructural evolution and mechanical properties of hypoeutectoid steels subjected to heat treatment. Tensile tests and microstructural analysis were performed on samples processed under varying magnetic field strengths (0 T, 5 T, and 9 T) and different austenitization incubation times. The results indicate that the application of a magnetic field alters the fraction of proeutectoid ferrite phase without changing the cooling rates and heat treatment process. Additionally, pearlite microstructural features such as lamellar spacing and misorientation angles exhibit variations under different field strengths. While the pearlite nodule diameter remains largely unaffected, an increase in percentage elongation and strength is observed in the 5 T treated sample, attributed to changes in microstructural features with the magnetic field. Additionally, the percentage elongation is reduced in the samples heat treated with reduced austenitization incubation times. The study further demonstrates that low-angle misorientations increased in the samples taken parallel to the magnetic field direction, influencing the mechanical response. These findings suggest that applying a magnetic field during heat treatment provides an additional driving force for phase transformations, offering a manufacturing process for tailoring microstructures and optimizing mechanical properties. Moreover, integrating magnetic fields in heat treatment processes has potential benefits in energy efficiency.

High magnetic field↗

Comprehensive evaluation of attitude and orbit estimation using real earth magnetic field data

A single, augmented extended Kalman filter (EKF) which simultaneously and autonomously estimates spacecraft attitude and orbit was developed and tested with simulated and real magnetometer and rate data. Since the earth's magnetic field is a function of time and position, and since time is accurately known, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft's orbit, are a function of orbit and attitude errors. These differences can be used to estimate the orbit and attitude. The test results of the EKF with magnetometer and gyro data from three NASA satellites are presented and evaluated.

Deutschmann, Julie↗

Electromagnetic ion cyclotron waves stimulated by modest magnetospheric compressions

AMPTE/CCE magnetic field and particle data are used to test the suggestion that increased hot proton temperature anisotropy resulting from convection during magnetospheric compression is responsible for the enhancement in Pc 1 emission via generation of electromagnetic ion cyclotron (EMIC) waves in the dayside outer equatorial magnetosphere. The relative increase in magnetic field is used to gauge the strength of the compression, and an image dipole model is used to estimate the motion of the plasma during compression. Proton data are used to analyze the evolution of the proton distribution and the corresponding changes in EMIC wave activity expected during the compression. It is suggested that enhancements in dynamic pressure pump the energetic proton distributions in the outer magnetosphere, driving EMIC waves. Waves are expected to be generated most readily close to the magnetopause, and transient pressure pulses may be associated with bursts of EMIC waves, which would be observed on the ground in association with ionospheric transient signatures.

Anderson, B. J.↗

High torque DC motor fabrication and test program

The testing of a standard iron and standard alnico permanent magnet two-phase, brushless dc spin motor for potential application to the space telescope has been concluded. The purpose of this study was to determine spin motor power losses, magnetic drag, efficiency and torque speed characteristics of a high torque dc motor. The motor was designed and built to fit an existing reaction wheel as a test vehicle and to use existing brass-board commutation and torque command electronics. The results of the tests are included in this report.

Makus, P.↗

Magnetic and Electrical Characteristics of Permalloy Thin Tape Bobbin Cores

The core loss, that is, the power loss, of a soft ferromagnetic material is a function of the flux density, frequency, temperature, excitation type (voltage or current), excitation waveform (sine, square, etc.) and lamination or tape thickness. In previously published papers we have reported on the specific core loss and dynamic B-H loop results for several polycrystalline, nanocrystalline, and amorphous soft magnetic materials. In this previous research we investigated the effect of flux density, frequency, temperature, and excitation waveform for voltage excitation on the specific core loss and dynamic B-H loop. In this paper, we will report on an experimental study to investigate the effect of tape thicknesses of 1, 1/2, 1/4, and 1/8-mil Permalloy type magnetic materials on the specific core loss. The test cores were fabricated by winding the thin tapes on ceramic bobbin cores. The specific core loss tests were conducted at room temperature and over the frequency range of 10 kHz to 750 kHz using sine wave voltage excitation. The results of this experimental investigation will be presented primarily in graphical form to show the effect of tape thickness, frequency, and magnetic flux density on the specific core loss. Also, the experimental results when applied to power transformer design will be briefly discussed.

Schwarze, Gene E.↗

Magnetic Damping of Solid Solution Semiconductor Alloys

The objective of this study is to conduct the Earth-based research sufficient to successfully propose a flight experiment (1) to experimentally test the validity of the modeling predictions applicable to the magnetic damping of convective flows in conductive melts as this applies to the bulk growth of solid solution semiconducting materials in the reduced gravitational levels available in low Earth orbit and (2) to assess the effectiveness of steady magnetic fields in reducing the fluid flows occurring in these materials during space processing. To achieve the objectives of this investigation, we are carrying out a comprehensive program in the Bridgman and floating-zone configurations using the solid solution alloy system Ge-Si. This alloy system was chosen because it has been studied extensively in environments that have not simultaneously included both low gravity and an applied magnetic field. Also, all compositions have a high electrical conductivity, and the materials parameters permit high growth rates compared to many other commonly studied alloy semiconductors. An important supporting investigation is determining the role, if any, that thermoelectromagnetic convection (TEMC) plays during growth of these materials in a magnetic field. Some compositional anomalies observed by us in magnetic grown crystals can only be explained by TEMC; this has significant implications for the deployment of a Magnetic Damping Furnace in space. This effect will be especially important in solid solutions where the growth interface is, in general, neither isothermal nor isoconcentrational. It could be important in single melting point materials, also, if faceting takes place producing a non-isothermal interface.

Szofran, Frank R.↗

Challenges in Pulsed-Field Gradient Nuclear Magnetic Resonance on Magnetically Heterogeneous Interfaces: Sequence and Field-Dependent Apparent Diffusion Coefficients

It is well known that the internal gradient (gi) that exists within pores haunts the diffusion coefficient (D) as measured by the pulsed-field gradient (PFG) nuclear magnetic resonance (NMR). Several PFG-NMR methods developed to determine an accurate D were not successful. Then, the steady-state diffusion coefficient (Dapp,8) for the cation [C4mim]+ of [C4mim][Tf2N]; [1-butyl-3-methylimidazolium][bis(trifluoromethylsulfonyl)imde] ionic liquid confined in ordered mesoporous carbon (OMC) were determined by comparing Dapp,8 obtained from 1H PFG-NMR performed with three different stimulated echo sequences: STE, APFG, and MPFG under the two external magnetic field strength, B0 = 9.4 and 14.1 Tesla. The measured Dapp,8 which is an order of magnitude smaller than D of bulk [C4mim][Tf2N], is in good agreement between APFG and MPFG both in B0 = 9.4 and 14.1 Tesla. However, the strong gi artifact, which caused apparent diffusion coefficient (Dapp) depending strongly and weakly on B0 and temperature, respectively, in diffusion-time dependent Dapp, Dapp(?) obtained from a sequence with monopolar gradients (STE) was suppressed by using sequences employing bipolar gradients (APFG and MPFG) in the region of steady-state diffusion. But incompletely suppressed gi artifact resulting in the different behaviors of the early part of Dapp(?) between the sequences leads a ˜ 0.6 and 0.9 in MPFG and APFG, respectively, in the relationship between mean squared displacement and diffusion time: = 2Dta, where a = 0.5 and 1 for 1-dimensional single file diffusion and 3-dimensional bulk diffusion, respectively. The above observations clearly show that the diffusion behavior of ions/molecules within the pores and pore structure, such as the surface-to-volume ratio? (D?_app (?)=D_0 [1-4/(9vp) S/V v(D_0 ?)]) and tortuosity (T = D0/Dapp,8), are possible to be misunderstood, especially in the systems with a non-negligible gi. This work demonstrates that it may be necessary to test several PFG sequences under multiple external magnetic fields for the correct determination of the diffusion behavior of ions/molecules in the pores with a larger internal gradient, gi.

Han, Kee Sung↗