The Pioneer Array and integration of a wave energy converter (WEC)
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A site energy management system is a critical component of future high-power EV charging hubs. It monitors and supervises all inter-hub operations, coordinates grid interactions, and implements energy management strategies and load-sharing controls at various levels and time scales. This report provides a comprehensive high-level overview and guidelines on the essential elements of such energy management systems. These elements primarily focus on the core functions, architecture, and monitoring aspects of site energy management. The core functions define the grid services and operational objectives that a charging hub is expected to provide and achieve. The architectural section investigates the coordination between hub assets, different control schemes, and their potential benefits and drawbacks. Lastly, the report discusses the needs, types, and functionalities of a monitoring and visualization system.
This dataset contains an aggregated and processed version of U.S. (CONUS) wind farm generation rates (~2001-2024, depending on data availability), as well as co-located subsurface estimates for each wind farm location in the Enhanced Geothermal System data from Aljubran & Horne (2024).
Abstract not provided.
To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.
We developed a synergistic ocean renewable system where an array of Wave Energy Converters (WEC) with adaptive resonance was collocated with a Floating Offshore Wind Turbine (FOWT) such that the WECs, capturing wave energy through the resonance adapting to varying irregular waves, consequently reduced FOWFT loads and turbine motions. Combining Surface-Riding WECs (SR-WEC) individually designed to feasibly relocate their natural frequency at the peak of the wave excitation spectrum for each sea state, and to obtain the highest capture width ratio at one of the frequent sea states for annual average power in a tens of kilowatts scale with a 15 MW FOWT based on a semi-submersible, Bayesian Optimization is implemented to determine the arrangement of WECs that minimize the annual representation of FOWT’s wave excitation spectra. The time-domain simulation of the system in the optimized arrangement is performed, including two sets of interactions: one set is the wind turbine dynamics, mooring lines, and floating body dynamics for FOWT, and the other set is the nonlinear power-take-off dynamics, linear mooring, and individual WECs’ floating body dynamics. Those two sets of interactions are further coupled through the hydrodynamics of diffraction and radiation. For sea states comprising Annual Energy Production, we investigate the capture width ratio of WECs, wave excitation on FOWT, and nacelle acceleration of the turbine compared to their single unit operations. We find that the optimally arranged SR-WECs reduce the wave excitation spectral area of FOWT by up to 60% and lower the turbine’s peak nacelle acceleration by nearly 44% in highly occurring sea states, while multiple WECs often produce more than the single operation, achieving adaptive resonance with a larger wave excitation spectra for those sea states. The synergistic system improves the total Annual Energy Production (AEP) by 1440 MWh, and we address which costs of Levelized Cost Of Energy (LCOE) can be reduced by the collocation.
Composite materials have become ubiquitous in the aerospace industry due to their exceptionally light weight and high strength characteristics, as well as their unique ability to be engineered and tailored to meet specific loading conditions and performance requirements. These advanced materials offer superior strength-to-weight ratios compared to traditional metallic materials, making them particularly valuable in weight-critical aerospace applications where every pound saved translates to improved efficiency and performance. In currently operating fleets of commercial and military aircraft, composite materials have been successfully applied to critical structural components, including primary load-bearing elements such as the fuselage sections and flooring structures, which must withstand significant in-flight loads and provide passenger safety. Additionally, these materials have been specifically tailored and optimized for aerodynamic components such as wings and tail assemblies, where their ability to be molded into complex shapes while maintaining structural integrity is particularly advantageous. The application of composite materials extends beyond primary structural elements into the realm of internal cabin components, most notably in innovative seat designs where weight reduction and structural integration are paramount concerns. Modern composite seat structures can be designed to integrate multiple functions, including structural support, comfort features, and safety systems, all while maintaining the lightweight characteristics essential for aircraft performance.
Marine resources such as waves and tides house immense potential to serve as energy-rich sources of renewable power generation. They are known to be highly available,persistent and predictable in nature. Therefore, these can serve as one of the critical components for a primarily renewable energy-driven, resilient and robust future power grid. Although some inherent temporal characteristics of these resources lend themselves favorably to potential grid applications, the inclusion of storage allows the benefits and value streams to become realized more fully. In this paper, we present a framework for assessing impact of marine energy resources inclusion on the overall load generation balance and its impact on the relevant storage requirements to obtain the desired level of renewable energy penetration. From this study, we can critically infer two main points - (a) the relative storage requirements for grid operations with and without marine energy, and (b) the avoided cost of storage by including marine energy into the generation mix. We demonstrate our framework for two different locations across the United States.
Abstract not provided.
A distributed control system uses a central controller in Internet communication with a local controller to manage grid tie attachment with a battery to form an integrated battery energy storage system (BESS). The BESS is capable of charging or discharging the battery, as well as correcting grid phase with volt amp reactive (VAR) leading or lagging operation modes. Examples shown include simple BESS charging and discharging, BESS integrated with renewable energy sources (here photovoltaic), and direct current fast charge (DCFC) connections with an electric vehicle.
Special considerations exist for island grids seeking to smoothly integrate distributed energy resources (DERs), such as rooftop photovoltaics (PV), with an existing fossil fuel-based grid without compromising system stability and reliability. Hawaii, having successfully integrated nonconventional renewable energy sources for a hybrid electricity grid, may serve as a guide for technical specifications and interconnection policy. Island grid planners may seek to follow Hawaii's example by standardizing technical specifications of generators, particularly for advanced inverter components.
Liquid air energy storage (LAES) and pumped thermal energy storage (PTES) are two closely related technologies that employ thermodynamic cycles to store electricity in the form of thermal energy. This chapter describes the integration of PTES and LAES in a single combined cycle (PT-LAES), where the PTES side provides the cold source required to drive the air liquefaction process. This presents several advantages compared to the separate cycles, including the partial or complete removal of cold stores, a higher energy density and the achievement of full air liquefaction. Notably, PT-LAES does not depend on external sources of heat or cold and thus constitutes a stand-alone system. As a result, PT-LAES can also be viewed as an advanced LAES cycle with full liquefaction.
Power electronic (PE) systems are increasingly being integrated into distribution and sub-distribution networks in support of distributed energy resource integration (DERs), electric vehicle (EV) charging (particularly in the case of fast charging infrastructure), and improvement in power quality for high performance computing and/or servers farms. This provides an opportunity to research and develop integrated PE systems that can function as single systems thereby bringing additional functionality and benefits to the overall system. The goal of this paper is to demonstrate foundational technologies and capabilities for a multiport power electronics energy hub that can intelligently coordinate and control integrated sources and loads. The focus for this digest is on a commercial building use case which is demonstrated in hardware.
With the increasing integration of Distributed Energy Resources (DER) into the electric grid, maintaining grid reliability and resilience requires that these devices remain secure. This paper discusses a cybersecurity vulnerability assessment methodology that incorporates best practices from Sandia National Laboratories, SANS Institute, OWASP Foundation, and other web and Internet of Things (IoT) penetration testing (“pen testing”) programs, courses, and frameworks for assessing the security posture of devices. The methodology involves five sequential steps: (1) Collect Public Information, (2) Extract Hardware Details, (3) Inventory Software Components, (4) Identify Vulnerabilities, and (5) Test Vulnerabilities. Each step uncovers potential weaknesses in both hardware and software components of DER devices, considering adversary tactics, techniques, and procedures (TTPs), and potential attack vectors along the way. The results from the execution of this method on multiple residential- and small commercial-scale photovoltaic (PV) inverters reveled hardware and software vulnerabilities, which highlight the benefit of taking a methodical approach to discover vulnerabilities. While the specific vulnerability details are not shared here, a generalized overview of findings underscore the importance of robust security assessments for DER devices. Adoption of an assessment framework of this kind will identify and mitigate cybersecurity threats and bolster the resilience of DER-integrated electric grids.
Large-scale integration of energy storage on the electric grid will be essential to enabling greater penetration of intermittent renewable energy sources, modernizing the grid for increased flexibility security, reliability, and resilience, and enabling cleaner forms of transportation. The purpose of this report is to summarize Sandia's research and capabilities in energy storage and to provide a preliminary roadmap for future efforts in this area that can address the ongoing program needs of DOE and the nation. Mission and vision statements are first presented followed by an overview of the organizational structure at Sandia that provides support and activities in energy storage. Then, a summary of Sandia's energy storage capabilities is presented by technology, including battery storage and materials, power conversion and electronics, subsurface-based energy storage, thermal/thermochemical energy storage, hydrogen storage, data analytics/systems optimization/controls, safety of energy storage systems, and testing/demonstrations/model validation. A summary of identified gaps and needs is also presented for each technology and capability.