Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Increased panel height enhances cooling for photovoltaic solar farms

We report solar photovoltaic (PV) systems suffer substantial efficiency loss due to environmental and internal heating. However, increasing the canopy height of these systems promotes surface heat transfer and boosts production. This work represents the first wind tunnel experiments to explore this concept in terms of array flow behavior and relative convective heat transfer, comparing model solar arrays of varied height arrangements - a nominal height, extended height, and a staggered height configuration. Analyses of surface thermocouple data show average Nusselt number (Nu) to increase with array elevation, where panel convection at double height improved up to 1.88 times that of the nominal case. This behavior is an effect of sub-array entrainment of high velocity flow and panel interactions as evidenced through flow statistics and mean kinetic energy budgets on particle image velocimetry (PIV) data. The staggered height arrangement encourages faster sub-panel flow than in the nominal array. Despite sub-array blockage due to the lower panel interaction, heat shedding at panel surfaces promotes improvements on over 1.3 times that of the nominal height case.

14 SOLAR ENERGY↗

Thermal-Mechanical Analysis of an Additive Manufacturing Ceramic Heat Exchanger for High-Temperature Recuperator in a sCO2 Power System

Supercritical CO2 (sCO2) Brayton power cycle can be configured in a closed-loop power system and has a potentially high cycle efficiency. Compactness and high efficiency of a sCO2 power block make the sCO2 Brayton cycle a versatile power cycle in broad applications. While many heat sources are of sufficient intensity to produce high temperature working fluids to achieve high cycle efficiency, the thermal-mechanical stability of traditional materials (e.g., steels and nickel-based superalloys) used in construction of heat exchangers and turbine components limits the operating conditions and thus thermodynamic efficiency of the system. This effort seeks to establish the viability of ceramic heat exchanger technologies for the most extreme operating conditions envisioned for power generation and other high temperature processes. Heat exchangers constructed from ultra-high temperature ceramics, a class of extreme environment materials featuring melting points (Tmp.) above 3000 degrees C, is particularly appealing for sCO2 Brayton cycles given their ultra-low creep rates and very high retained strength at low homologous temperatures (i.e., T < 0.5 Tmp., or at least 1500 degrees C). To translate these materials properties to ultra-high temperature heat exchangers, innovations are required in ceramic manufacturing techniques to realize the complex architectures featured in compact heat exchangers with high power density. With appropriate processing, ZrB2-SiC based compositions can be sintered to near full density and shaped into complex topologies via ceramic additive manufacturing methods. This paper analyzes heat exchanger designs and explores thermal-mechanical implications of the operating environment. Thermal flow, heat transfer, and conjugate mechanical analyses provide insights into benefits and risks associated with the design approach.

additive manufacturing↗

Energy efficiency based control for a cooling system

A method for controlling a cooling system based on a heat dissipation of an electronic module and an ambient air temperature includes determining a combination of individual controls on components of the cooling system that achieve a specific amount of cooling based on a cooling power relationship for the plurality of components, the heat dissipation of the electronic module and the ambient air temperature, and applying the individual controls to the plurality of components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency based control for a cooling system

A method for controlling a cooling system based on a heat dissipation of an electronic module and an ambient air temperature includes determining a combination of individual controls on components of the cooling system that achieve a specific amount of cooling based on a cooling power relationship for the plurality of components, the heat dissipation of the electronic module and the ambient air temperature, and applying the individual controls to the plurality of components.

Chainer, Timothy J.↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) (Final Report)

This report is a final deliverable for project 81966: Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) Commercial heat pump water heater (CHPWH) systems can significantly improve the energy efficiency of service water heating (SWH), aka domestic hot water (DHW), in commercial and multifamily buildings but have not yet achieved widespread adoption due to pricing, complexity, and perceived risk factors. The goal of this project – Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial HPWHs (Scaling Up) – was to demonstrate and validate a holistic systems approach for CHPWHs that de-risks the technology, creating a reliable, cost-effective, and repeatable approach to CHPWH deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method for performing laser powder bed fusion using controlled, supplemental in situ surface heating to control microstructure and residual stresses in formed part

The present disclosure relates to an additive manufacturing system for forming a part using a powder material. In one embodiment the system makes use of a primary heat generating subsystem to generate a fusing beam for heating and fusing at least one of select portions of a powder layer, or an entire area of a powder layer, deposited on a build plate. The system also incorporates a beam steering subsystem for steering the fusing beam over the powder layer. A supplemental heating subsystem is used to generate a wide area beam to heat a portion of the powder layer either prior to fusing, along with the fusing operation, or subsequent to fusing of the powder with the fusing beam. The wide area beam has an intensity which is insufficient to fuse the powder, and alters a microstructure of the powder layer as the powder layer is at least one of fused or as it cools, to thus relieve stress in the part.

Smith, William↗

Thermal Charging Rate of Composite Wax-Expanded Graphite Phase Change Materials

Phase change materials (PCMs) are valuable for their ability to store heat nearly isothermally around their phase transition temperature. PCMs are at the core of latent heat thermal energy storage (LHTES) systems, which provide the ability to buffer high thermal loads or decouple the time when heating or cooling is needed from when it is produced. Thermal charging and discharging of LHTES systems often employ a constant temperature source, and the rate at which heat can be exchanged is dependent on the thermophysical properties of the PCM. For graphite composite PCMs, the high thermal conductivity of the graphite enables an increased heat transfer rate through the material, but its presence displaces PCM which reduces the effective volumetric latent heat of the composite relative to the pure PCM. This results in a tradeoff between thermal power and volumetric energy storage capacity. The thermal charging rate is the average thermal energy stored in the material for some elapsed time. In this study, composite PCMs of compressed expanded natural graphite (CENG) and n-Octadecane are studied. Samples with varying CENG mass fractions were synthesized and the thermal charging rate was measured under a constant temperature boundary condition. For evaluation of the expanded graphite-PCM composite, one boundary of the material was exposed to a 50°C constant temperature plate, above the 27.5°C melting temperature of the PCM. The melting front progression [mm-s-1] and the thermal charging rate [W-cm-2] of the PCM were determined, and the results were compared with analytical predictions for the 1-D semi-infinite phase change. For CENG addition up to 5.75% mass fraction, a 450% thermal conductivity increase was observed with a 5% decrease in volumetric energy density as compared to pure octadecane. The average thermal charging rate was increased by over 430% for the melt to penetrate a depth of 22 mm. The experimental results matched analytical predictions, indicating that higher CENG fractions can be evaluated using analytical approaches.

Hirschey, Jason↗

Materials Challenges and Opportunities for Energy Generation, Conversion, Delivery, and Storage (Applied Energy Tri-Laboratory Consortium Workshop Report)

This report documents the outcomes of the Tri-Laboratory Materials Workshop that was held July 31 and August 1, 2019 to begin addressing the needs, opportunities, and challenges associated with the development, fabrication, and testing of the needed materials and components for integrated hybrid energy systems (i.e., incorporating nuclear, fossil, and renewables for electric and thermal applications). This was accomplished by assembling the research program leads and principal investigators at Idaho National Laboratory (INL), National Energy Technology Laboratory (NETL), and National Renewable Energy Laboratory (NREL), who support the research and development of new technology and system integration. The team then identified and prioritized key materials development needs. This effort was intended to enhance communications and synergy among the Tri-Lab partners. Advanced functional and structural materials are central to transformative energy technologies for energy generation, conversion, delivery, and storage. With that in mind, the workshop focused on identifying and assessing the foundational materials research needs at both the basic and applied levels. Materials challenges include the ability to withstand harsh environments, such as high temperatures and pressures, corrosion, oxidation, or irradiation while maintaining flexible mission profiles and long service lifespans. Advanced energy system material challenges and needs range from materials for the capture, upgrading/concentration, storage, and delivery of low-grade heat to materials for high temperature environments that involve liquid metals, molten salt, and very high temperature gas heat delivery and storage systems. Material improvements are needed for hybrid energy systems due to accelerated corrosion and stress-fatigue failure of materials and equipment, which results from increased frequency and amplitude of thermal, mechanical, and electrical cycling of systems components. Multifunctional materials are needed for high temperature solid-oxide fuel cells, advanced electrochemical reactors, and in-process separation. Relative to materials manufacturing, application of advanced additive and subtractive methods need to be understood to develop both thin-layer homogenous materials and materials of graded composition. Materials modeling and machine learning will be critical to accelerate the design and production of power electronics, and nuclear reactor materials and fuel, as well as to gain an understanding of beneficial materials phenomena or deleterious microstructure evolution. There is also a need for standardized models, computational structures, data reporting protocols and modeling tools across the three laboratories. This would allow consistent results, analysis, and data sharing. Combining computational capabilities between the three laboratories (e.g., hardware, software) would greatly increase computational capabilities and throughput. The workshop identified the need for laboratories to anticipate and address problems that will occur during scale-up. Laboratory work must connect with industry to ensure that research focuses on processes that are scalable and marketable. Industry input and perspective are essential to guide laboratory research to meet these requirements and deploy new technology in industrial demonstrations. Another aspect of scale-up is the integration of multiple systems since new challenges often arise at the subsystem interfaces. Establishing a scale-up manufacturing demonstration/pilot plant, potentially as an industrial user facility, would be beneficial to the laboratories and industry. That modular scale-up manufacturing demonstration/pilot plant would allow researchers to find and resolve interface problems that cannot be identified by focusing only on individual parts. Communication exchanges among the organizers, attendees, and workshop survey responses indicate that the workshop was successful in achieving its goal to identify key technology gaps and research needs. Strong positive feedback was received on the sharing of ideas, capabilities, talent, and passion to move forward on the materials-related action items.

36 MATERIALS SCIENCE↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Grid-Scale Electricity Storage at Lowest Possible Cost Enabled by Pumped Heat Electricity Storage (Final Report)

Grid-scale energy storage technologies that can provide greater than 10 hours of electricity at full power address a critical need for full penetration of renewables on electricity grids worldwide, minimize renewable curtailment, and maximize grid security and reliability. Pumped Heat Energy Storage (PHES) systems can store energy thermally in any location at the low costs necessary for displacing fossil fuels, reducing foreign fuel imports, and reducing emissions to maintain the energy security of the United States. The award allowed Southwest Research Institute® (SwRI®) and Malta, Inc. (Malta) to advance the PHES concept to a proof-of-concept demonstration for a kW-scale system. The project focused on system operation and integration. The main project objectives were: 1. Address first implementation challenges 2. Explore system control strategies and operation 3. Translate lessons learned to the full-scale system Through these objectives the project completes a first demonstration of this technology and reduces the technical risk associated with a full-scale system.

25 ENERGY STORAGE↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

Adsorption system

An adsorption system can be used as part of a climate control system in a vehicle or in any other space requiring heating or cooling. The adsorbent system can include an enclosure, a plurality of layers arranged in a stack inside the enclosure, and a vapor channel inside the enclosure.

Wang, Evelyn N.↗

Integrated Thermal Energy Storage and Brayton Cycle Equipment Demonstration (Integrated TESTBED) Project Design Basis

The Integrated Thermal Energy Storage and Brayton cycle Equipment Demonstration (Integrated TESTBED) project seeks to retire commercial-scale risks associated with the design, integration,and operation of a supercritical carbon dioxide (sCO2) power cycle and concentrating solar power (CSP) thermal energy storage (TES) system. This requires an understanding of commercial-scale collector system transient impacts on the TES system, the dynamics of heat exchange from theTES to the power cycle, and the control and operation of the power cycle to accommodate various dispatch strategies. In order to retire these risks, Heliogen has proposed to construct a 5 MWe CSP demonstration facility based on directly heated particle and sCO2 technology. The receivers, primary heat exchanger, and power cycle will be deployed at a full commercial scale based on Heliogen’s modular plant architecture to ensure actual system integration risks are validated during design, construction, and operation. This work summarizes the design basis for the Integrated TESTBED project demonstration facility including a design target for capacity factor to support test operations, hours of storage, particle silo arrangement, centrifugal article receivers, a diffusion bonded particle-sCO2 heat exchanger, and a 5 MWe (net) integrally geared sCO2 recompression Brayton cycle.

14 SOLAR ENERGY↗

Characteristics of Ultralow Aspect Ratio Toroidal Plasmas and Non-Solenoidal Startup and Edge Stability Studies at Near-Unity Aspect Ratio (Final Report)

This grant supported a long-term research and development program to explore the physics and technology of spherical tokamak (ST) plasma behavior at near-unity aspect ratio ( A ). The PEGASUS Toroidal Experiment is a university-scale ( R ) ~ 0.40 m, α ~ .35 m, I p ≤ 0.3 MA, B T ≤ 0.15 T) experiment that accesses A → 1, to provide large values of the normalized plasma current, I N = I p /α B T , or equivalently the toroidal field utilization factor I p / I TF . The research activities focused on: 1) developing the technique of Local Helicity Injection (LHI) as a viable means of initiating and growing an ST plasma without the use of a central solenoid; 2) exploring the equilibrium and stability properties of spherical tokamak plasmas at extremely low aspect ratio; and 3) obtaining new insights in the properties of the enhanced confinement H-mode regime at A ~ 1. The initial (Phase I) facility employed a unique high-stress central solenoid Ohmic for current drive and heating with simple magnet current waveforms. A subsequent major upgrade (Phase II) offered more flexible control of the plasma evolution along with a powerful LHI system for plasma initiation, heating and sustainment. The LHI technique consists of injection of high-density current streams into vacuum toroidal and vertical magnetic fields. These streams become unstable and support magnetic reconnection to allow the system to relax into a tokamak-like magnetic configuration. This program focused on: 1) development of electron current sources that provide sufficiently high injection currents in the challenging edge plasma region; 2) validation of theoretical limits to achievable I p arising from magnetic helicity and energy conservation plus absolute limits arising from relaxation to a minimal energy states; 3) tests of a power balance model to describe the evolution of the plasma current I p (t); and 4) study of magnetic fluctuations and their role in the I p evolution. This culminated in the production of toroidal currents of I p ≥ 0.2 MA with only ~8 kA of injected current. Operation with Ohmic induction alone in Phase I created plasmas with soft limits on the achievable I p and field utilization ( I p / I TF ~ 1) due to the onset of large low-order (2/1 or 3/2) internal resonant tearing modes. With the expanded capabilities in Phase II operation, methods employed to mitigate those modes and achieve I p / I TF > 1 were: 1) I TF ramp-downs; 2) non-solenoidal startup via LHI; and 3) extremely low I TF Ohmic operations assisted by LHI current injector pre-ionization. Extensive use of LHI-driven startup and drive for non-solenoidal operation produced favorable current profiles to stably operate tokamak plasmas with unprecedentedly high I N = I p / aB T ~ 15 and I p / I TF > 2. With strong reconnection-driven anomalous ion heating, this in turn provided access to tokamak plasmas with B t up to 100%, a world record 2 times higher than that previously achieved in advanced or spherical tokamaks. This high B t regime had a large fraction (~50%) of the plasma volume in a region of an absolute minimum- B configuration. The MHD stability limit in this regime was the ideal external kink mode without a stabilizing wall. These results provided the first demonstration of access to tokamak plasmas with very high B t , high i N , high elongation κ, and low internal inductance ℓ i , and as such served as a proof-ofprinciple for access to this long-sought ST regime. The naturally low B T needed for stability at A ≤ 1.2 reduces the L-H mode power threshold, P LH , so that H-mode plasmas were achieved with Ohmic heating alone. The power threshold for the transition to the H-mode regime was found to be 10× the accepted values from the ITER international scaling, confirming initial trends indicated by experiments on MAST and NSTX, and suggesting that the physics behind this transition is not yet fully understood. The density dependence of the transition and the observed insensitivity to whether the plasma is bounded by a limiter or magnetic divertor are consistent with the recent FM 3 model. Multiple unstable toroidal magnetic modes were measured during ELM (Edge Localized Mode) crashes, with generally lower toroidal mode numbers than seen at higher A , which was attributed to the larger peeling mode instability drive at low A . First-ever edge current profile measurements through an ELM crash showed current-carrying filaments were generated, as seen in ELM simulations and in electromagnetic blob transport theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computational Fluid Dynamics and Heat Transfer Modeling of a Dimpled Heat Exchanger

Multiphysics and analytical calculations were conducted for a heat exchanger with passive, natural circulation flow. A glycol/water working fluid convects the heat to a dimpled heat exchanger shell, which subsequently transfers the heat to the soil, which acts as the ultimate heat sink. Because the system is fully-passive, it is not subject to the expenses, maintenance, and mechanical breakdowns associated with moving parts. Density, heat capacity, and thermal conductivity material properties were measured for various soil samples, and subsequently included as input for the soil heat conduction model. The soil model was coupled to a computational fluid dynamics (CFD) heat exchanger model that included the dynamic Smagorinsky large eddy simulation and k- omega turbulence models. The analysis showed that the fluid dynamics and heat transfer models worked properly, albeit at a slow pace. Nevertheless, the coupled CFD/heat conduction simulation ran long enough to determine a key parameter—the amount of heat conducted from the heat exchanger to the ground. This unique performance value, along with experimental data, was used as input for stand-alone, fast-running CFD models, as well as boundaries to obtain solutions to partial differential equations for soil heat conduction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗