Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Simulator for Hydrologic Unstructured Domains (SHUD v1.0): numerical modeling of watershed hydrology with the finite volume method

Abstract. Hydrologic modeling is an essential strategy for understanding and predicting natural flows, particularly where observations are lacking in either space or time or where complex terrain leads to a disconnect in the characteristic time and space scales of overland and groundwater flow. However, significant difficulties remain for the development of efficient and extensible modeling systems that operate robustly across complex regions. This paper introduces the Simulator for Hydrologic Unstructured Domains (SHUD), an integrated, multiprocess, multiscale, flexible-time-step model, in which hydrologic processes are fully coupled using the finite volume method. SHUD integrates overland flow, snow accumulation/melt, evapotranspiration, subsurface flow, groundwater flow, and river routing, thus allowing physical processes in general watersheds to be realistically captured. SHUD incorporates one-dimensional unsaturated flow, two-dimensional groundwater flow, and a fully connected river channel network with hillslopes supporting overland flow and baseflow. The paper introduces the design of SHUD, from the conceptual and mathematical description of hydrologic processes in a watershed to the model's computational structures. To demonstrate and validate the model performance, we employ three hydrologic experiments: the V-catchment experiment, Vauclin's experiment, and a model study of the Cache Creek Watershed in northern California. Ongoing applications of the SHUD model include hydrologic analyses of hillslope to regional scales (1 m2 to 106 km2), water resource and stormwater management, and interdisciplinary research for questions in limnology, agriculture, geochemistry, geomorphology, water quality, ecology, climate and land-use change. The strength of SHUD is its flexibility as a scientific and resource evaluation tool where modeling and simulation are required.

58 GEOSCIENCES↗

Rotating Detonation Combustion for Gas Turbines: Modeling and System Synthesis to Exceed 65% Efficiency Goal (Phase II)

As of May 2019, all RDE test hardware and test operations were completed for this program. Over 700 hot fire tests were conducted at 4 facilities with 7 RDE assemblies, with the data available for future analysis. In particular, measured static and dynamic pressure and computational fluid dynamics (CFD) provided basis for pressure gain combustion (PGC) analysis of the Engineering Scale RDE. It was demonstrated via measurements and CFD that a carefully designed diffuser can recover some total pressure of the highly oscillatory RDE exhaust. In general, the isolator/injector is largest contributor of pressure losses; however a low loss design was demonstrated that improves significantly on previous natural-gas/air RDEs. Also, a tailored injector and mixing technique was demonstrated that allowed NG-air RDE operation with overall equivalence ratio of less than 0.6. CFD models by AR, the UofM and Purdue University were extensively used throughout the program to refine diffuser design for improved pressure recovery, to simulate injection and mixing, to estimate turbine interaction, to estimate combustor pressure gain anchored with test data and to provide input to other design and analytical tasks. CFD analyses were completed for many of the configurations tested at Purdue with the 13.4” RDE including the shark fin and low area ratio isolators. Results were compared favorably to available hot fire test particle image velocimetry (PIV) measurements and wave speeds. The results of these CFD analyses suggest a modest pressure gain of 33% with a sufficiently low area ratio isolator. A thermodynamic power plant system model was set up which utilizes an RDE combustor. The performance of the RDE combustor module was scaled based on measurements from the Engineering Scale RDE tests with low loss injector and tailored fuel flow. This combined model indicates potential for significant plant efficiency improvement. The successful tailored fuel injection test result with lower than .6 equivalence ratio has implication that a power plant can use a RDE combustor configuration where all the air flows through the combustion zone thereby not requiring a bypass mixer. In this configuration, the results of the natural gas combined cycle (NGCC) plant system indicate net efficiency of 66.4%.

02 PETROLEUM↗

An integrated high-throughput robotic platform and active learning approach for accelerated discovery of optimal electrolyte formulations

Solubility of redox-active molecules is an important determining factor of the energy density in redox flow batteries. However, the advancement of electrolyte materials discovery has been constrained by the absence of extensive experimental solubility datasets, which are crucial for leveraging data-driven methodologies. In this study, we design and investigate a highly automated workflow that synergizes a high-throughput experimentation platform with a state-of-the-art active learning algorithm to significantly enhance the solubility of redox-active molecules in organic solvents. Our platform identifies multiple solvents that achieve a remarkable solubility threshold exceeding 6.20 M for the archetype redox-active molecule, 2,1,3-benzothiadiazole, from a comprehensive library of more than 2000 potential solvents. Significantly, our integrated strategy necessitates solubility assessments for fewer than 10% of these candidates, underscoring the efficiency of our approach. Our results also show that binary solvent mixtures, particularly those incorporating 1,4-dioxane, are instrumental in boosting the solubility of 2,1,3-benzothiadiazole. Beyond designing an efficient workflow for developing high-performance redox flow batteries, our machine learning-guided high-throughput robotic platform presents a robust and general approach for expedited discovery of functional materials.

25 ENERGY STORAGE↗

Experimental Studies of NGNP Reactor Cavity Cooling System With Water

This project will investigate the flow behavior that can occur in the reactor cavity cooling system (RCCS) with water coolant under the passive cooling-mode of operation. The team will conduct separate-effects tests and develop associated scaling analyses, and provide system-level phenomenological and computational models that describe key flow phenomena during RCCS operation, from forced to natural circulation, single-phase flow and two-phase flow and flashing. The project consists of the following tasks: Task 1. Conduct separate-effects, single-phase flow experiments and develop scaling analyses for comparison to system-level computational modeling for the RCCS standpipe design. A transition from forced to natural convection cooling occurs in the standpipe under accident conditions. These tests will measure global flow behavior and local flow velocities, as well as develop instrumentation for use in larger scale tests, thereby providing proper flow distribution among standpipes for decay heat removal. Task 2. Conduct separate-effects experiments for the RCCS standpipe design as two-phase flashing occurs and flow develops. As natural circulation cooling continues without an ultimate heat sink, water within the system will heat to temperatures approaching saturation , at which point two-phase flashing and flow will begin. The focus is to develop a phenomenological model from these tests that will describe the flashing and flow stability phenomena. In addition, one could determine the efficiency of phase separation in the RCCS storage tank as the two-phase flashing phenomena ensues and the storage tank vents the steam produced. Task 3. Develop a system-level computational model that will describe the overall RCCS behavior as it transitions from forced flow to natural circulation and eventual two-phase flow in the passive cooling-mode of operation. This modeling can then be used to test the phenomenological models developed as a function of scale.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MAGNETIC FIELD GENERATION AND PARTICLE ENERGIZATION AT RELATIVISTIC SHEAR BOUNDARIES IN COLLISIONLESS ELECTRON-POSITRON PLASMAS

Using particle-in-cell simulations, we study the kinetic physics of relativistic shear flow in collisionless electron-positron (e+e-) plasmas. We find efficient magnetic field generation and particle energization at the shear boundary, driven by streaming instabilities across the shear interface and sustained by the shear flow. Nonthermal, anisotropic high-energy particles are accelerated across field lines to produce a power-law tail turning over just below the shear Lorentz factor. These results have important implications for the dissipation and radiation of jets in blazars and gamma-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of electron temperature and electron flow on O-X conversion

Effects of electron temperature and electron flow on Ordinary-Extraordinary (O-X) conversion in the range of electron cyclotron frequency are investigated. The modified optimal parallel refraction index, N{sub zc}, and the conversion coefficient are obtained analytically from the kinetic dispersion relation. The presence of finite electron temperature shifts the O-X conversion layer towards a region of lower density and increases the value of N{sub zc}; while the effect of electron flow depends on its direction with respect to the parallel wave vector. When the electron flow is along the parallel wave vector, N{sub zc} will be increased and the effects of finite electron temperature and finite electron flow accumulate. As a result, a more oblique incidence angle is required for efficient O-X conversion. For typical Tokamak plasmas, the efficiency of O-X conversion will decrease without the consideration of the two effects. When the electron flow is in the direction opposite to the parallel wave vector, the two effects compete, even cancel each other.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental analysis of the pressure drop and heat transfer through metal foams used as volumetric receivers under concentrated solar radiation

The main objective of this work was to evaluate the behavior of porous materials, when treated as volumetric receivers under concentrated solar radiation. For this reason various porous metallic and ceramic materials have been tested as potential receivers for concentrated solar radiation. The experimental investigation showed that their efficiency was depending on both materials parameters and flow conditions. In this work, a variety of foam materials such as Ni and Ni alloy, inconel, copper, aluminum and SiC with different open cell porosity were tested as potential media to be used as volumetric receivers and heat exchangers. However, since the results were similar, for space economy, only the results of two of them, nickel and inconel were presented in detail and compared with each other. (author)

14 SOLAR ENERGY↗

Operation and performance of microhexcavity pixel detector in gas discharge and avalanche mode

The Microhexcavity Panel (μHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The μHex is under development to be deployed as a scalable, fast timing (ns) and hermetically sealed gaseous tracking detector with high rate (> 100KHz / cm 2 ) capability. The devices reported here were fabricated as 16 × 16 pixel arrays of 2 mm edge-to-edge, 1 mm deep hexagonal cells embedded in a thin, 1.4 mm glass–ceramic wafer. Cell walls are metalized cathodes, connected to high voltage bus lines through conductive vias. Anodes are small, 457 μm diameter metal discs screen printed on the upper substrate. The detectors are filled with an operating gas to near 1 atm and then closed with a shut-off valve. They have been operated in both avalanche mode and gas discharge devices, producing mV to volt level signals with about 1 to 3 ns rise times. Operation in discharge mode is enabled by high impedance quench resistors on the high voltage bus at each pixel site. Results indicate that each individual pixel behaves as an isolated detection unit with high single pixel intrinsic efficiency to both βs from radioactive sources and to cosmic ray muons. Finally, continuous avalanche mode operation over several days at hit rates over 300 KHz / cm 2 with no gas flow have been observed. Measurements of pixel isolation, timing response, efficiency, hit rate and rate stability are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy-Duty Low-Temperature and Diesel Combustion & Heavy-Duty Combustion Modeling

Regulatory drivers and market demands for lower pollutant emissions, lower carbon dioxide emissions, and lower fuel consumption motivate the development of clean and fuel-efficient engine operating strategies. Most current production engines use a combination of both in-cylinder and exhaust emissions-control strategies to achieve these goals. The emissions and efficiency performance of in-cylinder strategies depend strongly on flow and mixing processes associated with fuel injection. Various diesel engine manufacturers have adopted close-coupled post-injection combustion strategies to both reduce pollutant emissions and to increase engine efficiency for heavy-duty applications, as well as for light- and medium-duty applications. Close-coupled post-injections are typically short injections that follow a larger main injection in the same cycle after a short dwell, such that the energy conversion efficiency of the post-injection is typical of diesel combustion. Of the various post-injection schedules that have been reported in the literature, effects on exhaust soot vary by roughly an order of magnitude in either direction of increasing or decreasing emissions relative to single injections (O’Connor et al., 2015). While several hypotheses have been offered in the literature to help explain these observations, no clear consensus has been established. For new engines to take full advantage of the benefits that post-injections can offer, the in-cylinder mechanisms that affect emissions and efficiency must be identified and described to provide guidance for engine design.

33 ADVANCED PROPULSION SYSTEMS↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

A Thermal Model for the Performance Analysis of Large Scale Spent Fuel Cooling Pond - 19173

This paper presents a thermal model for the performance analysis of a large scale cooling pond for the long term storage of spent nuclear fuel. The model has been developed using the knowledge gained from fundamental investigation using CFD and has been validated by comparing against reliable experimental and/or numerical data. It was then applied in the context of operation of a large scale pond to ascertain the sensitivity of various operational and environmental conditions. To develop the model, the water body along with the heating elements was considered as one zone and humid air inside the building as another zone, both of which are considered as well-mixed zones. Various input conditions namely, total heat load from the heat source, environmental temperature and relative humidity, ventilation rate, efficiency of the cooling tower, recirculation and make-up water flow rates have been programmed in the model. The statistical method AVONA has been used to assess the influence of the above variables. The results reveal that the efficiency of the cooling tower is the most influential parameter on the cooling performance of cooling pond within the considered values of heat load. It has also been found that the majority of the heat is taken by the recirculating water for very high heat load while the other modes of heat transfer are small but not insignificant. The model is capable of simulating the scenario of loss of cooling water and suggests that it can be used for managing a large pond efficiently as well as recovery from an accident situation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Learning Provably Stable Local Volt/Var Controllers for Efficient Network Operation

Here this paper develops a data-driven framework to synthesize local Volt/Var control strategies for distributed energy resources (DERs) in power distribution grids (DGs). Aiming to improve DG operational efficiency, as quantified by a generic optimal reactive power flow (ORPF) problem, we propose a two-stage approach. The first stage involves learning the manifold of optimal operating points determined by an ORPF instance. To synthesize local Volt/Var controllers, the learning task is partitioned into learning local surrogates (one per DER) of the optimal manifold with voltage input and reactive power output. Since these surrogates characterize efficient DG operating points, in the second stage, we develop local control schemes that steer the DG to these operating points. We identify the conditions on the surrogates and control parameters to ensure that the locally acting controllers collectively converge, in a global asymptotic sense, to a DG operating point agreeing with the local surrogates. We use neural networks to model the surrogates and enforce the identified conditions in the training phase. AC power flow simulations on the IEEE 37-bus network empirically bolster the theoretical stability guarantees obtained under linearized power flow assumptions. The tests further highlight the optimality improvement compared to prevalent benchmark methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Computational Models for the Flow of Milled Biomass Part II: Continuum-Mechanics Models

The design of efficient material-handling systems for milled lignocellulosic biomass is challenging due to their complex particle morphologies and frictional interactions. Computational modeling, including the discrete element method (DEM) and continuum-based finite-element/volume methods, may offer scientific insight and predictive capabilities for the flow of milled biomass in hoppers and feeders. Herein, this article (Part II) presents a review of current state-of-the-art continuum models for the flow of milled biomass, whereas DEM models are reviewed in a companion article (Part I). Advances of numerical methods to solve the global governing equations are discussed first, followed by a comprehensive review of constitutive models for granular materials, including Drucker–Prager, hypoplastic, Cambridge-type, inertial-rheology, and nonlocal granular fluidity models. Specifically, we provide in-depth discussion on the suitability of those models for milled lignocellulosic biomass materials in terms of nonlinear elasticity, dependence of flow strength on pressure, density and shear rate, and compaction (dilation) associated with hardening (softening). Furthermore, our study shows that, despite the recent advances in continuum granular flow modeling, the most suitable constitutive models still need further development to account for material parametrization, multiflow regimes, and multiscale behavior before they can be reliably used to optimize the design and operation of biomass handling systems.

09 BIOMASS FUELS↗

The Cascade Effectiveness of 3-Terminal Tandem Photocathode Architectures as Applied to CO 2 Reduction

Cascade catalysis for photoelectrochemical CO 2 reduction (CO 2 R) decouples the overall reaction into sequential steps occurring on separately optimized catalysts (for example, Ag and Cu) between which an intermediate species such as CO is transferred. A 3-terminal tandem (3TT) photovoltaic architecture advantageously holds two different catalytic regions at different potentials under a single illumination source, but its overall efficiency is low. Using a stochastic reaction-diffusion model, we have examined 3TT photocathode design principles, focusing on the coupling of surface chemistry and transport of CO both inside the boundary layer and outward, into the bulk electrolyte. We find that ensuring that the lateral diffusion distance within the boundary layer is short compared to the boundary layer thickness and controlling bulk flow are key, with interdigitated designs showing an overall conversion efficiency improvement by 2 orders of magnitude compared to the side-by-side case without flow. These findings can be adapted for other cascaded architectures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DYNAMO EFFICIENCY WITH SHEAR IN HELICAL TURBULENCE

To elucidate the influence of shear flow on the generation of magnetic fields through the modification of turbulence property, we consider the case where a large-scale magnetic field is parallel to a large-scale shear flow without direct interaction between the two in the kinematic limit where the magnetic field does not backreact on the velocity. By nonperturbatively incorporating the effect of shear in a helically forced turbulence, we show that turbulence intensity and turbulent transport coefficients (turbulent viscosity, {alpha} and {beta} effect) are enhanced by a weak shear, while strongly suppressed for strong shear. In particular, {beta} is shown to be much more strongly suppressed than {alpha} effect. We discuss its important implications for dynamo efficiency, i.e., on the scaling of the dynamo number with differential rotation.

79 ASTRONOMY AND ASTROPHYSICS↗

Hadronic vacuum polarization using gradient flow

The gradient-flow operator product expansion for QCD current correlators including operators up to mass dimension four is calculated through NNLO. This paves an alternative way for efficient lattice evaluations of hadronic vacuum polarization functions. In addition, flow-time evolution equations for flowed composite operators are derived. Their explicit form for the non-trivial dimension-four operators of QCD is given through order $\alpha_s^3$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust foil regenerator flow loss and heat transfer tests under oscillating flow condition

A regenerator works as an energy storage component in a Stirling engine. Thus, it is one of the most critical components that makes the Stirling engine highly efficient. Traditionally, the regenerators are made of wire media such as woven screens and random fibers. These wire regenerators experience considerably high flow losses through the regenerator due to the flow separation and the resulting vortices. The high flow losses associated with the flow separation and vortices result in a lower engine efficiency. This research is to test a new robust foil regenerator to investigate its feasibility for free-piston Stirling engine applications. The robust foil regenerator is configured with parallel flow channels and stiffening ribs. Comparing to complex flows patterns in woven screen and random fiber regenerators, the flows in the parallel plates are simple and the flow losses are considerably small, and the heat transfer coefficient is also relatively small. To test the regenerator experimentally, a regenerator test rig was manufactured. To verify the accuracy of the test rig, a woven screen regenerator was made and tested prior to the robust foil regenerator test. The friction factor correlation of the woven screen regenerator shows a good agreement with the published regenerator correlations. The robust foil regenerator tests were conducted under the oscillating flow condition with different Reynolds numbers. The flow losses were measured with dynamic pressure transducers and the friction coefficient was derived from measured pressure drop. The measured temperature difference over the regenerator was used to calculate the heat transfer coefficient and Nusselt number. The figure of merit with two methods of NPH/NTU ratio and j/f ratio was calculated to evaluate the suitability of the robust foil regenerator. The results show that the robust foil regenerator has considerably higher figure of merit and therefore, better performance than other types of regenerator.

42 ENGINEERING↗