Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Kaon gluon parton distribution and momentum fraction from 2+1+1 lattice QCD with high statistics

We present a high-statistics lattice-QCD determination of the kaon gluon parton distribution function and gluon momentum fraction. We use clover valence fermion action to take 1,296,640 kaon-correlator measurements on a highly improved staggered quark ensemble with 𝑎 ≈ 0.12 fm and 310-MeV pion mass generated by the MILC Collaboration. A detailed investigation into the impact of gauge-link smearing on the gluonic matrix elements indicates that five steps of hypercubic smearing offer an effective balance between signal quality and preservation of long-distance physics. We report a nonperturbatively renormalized kaon gluon momentum fraction of Math output error at 𝜇 = 2 GeV in the Math output error scheme. Using reduced pseudo-Ioffe-time-distribution matrix elements and pseudo-parton-distribution-function (PDF) matching, we extract the kaon gluon PDF and compare with the prediction from the Dyson-Schwinger equation and with the pion PDF obtained from the same ensemble.

First-principles calculations↗

Multiscale Physics of Atomic Nuclei from First Principles

Atomic nuclei exhibit multiple energy scales ranging from hundreds of MeV in binding energies to fractions of an MeV for low-lying collective excitations. As the limits of nuclear binding are approached near the neutron and proton drip lines, traditional shell structure starts to melt with an onset of deformation and an emergence of coexisting shapes. It is a long-standing challenge to describe this multiscale physics starting from nuclear forces with roots in quantum chromodynamics. Here, we achieve this within a unified and nonperturbative quantum many-body framework that captures both short- and long-range correlations starting from modern nucleon-nucleon and three-nucleon forces from chiral effective field theory. The short-range (dynamic) correlations which account for the bulk of the binding energy are included within a symmetry-breaking framework, while long-range (static) correlations (and fine details about the collective structure) are included by employing symmetry projection techniques. Our calculations accurately reproduce—within theoretical error bars—available experimental data for low-lying collective states and the electromagnetic quadrupole transitions in 20−30 Ne. In addition, we reveal coexisting spherical and deformed shapes in 30 Ne, which indicates the breakdown of the magic neutron number 𝑁 = 20 as the key nucleus 28 O is approached, and we predict that the drip line nuclei 32,34 Ne are strongly deformed and collective. By developing reduced-order models for symmetry-projected states, we perform a global sensitivity analysis and find that the subleading singlet 𝑆-wave contact and a pion-nucleon coupling strongly impact nuclear deformation in chiral effective field theory. The techniques developed in this work clarify how microscopic nuclear forces generate the multiscale physics of nuclei spanning collective phenomena as well as short-range correlations and allow one to capture emergent and dynamical phenomena in finite fermion systems such as atom clusters, molecules, and atomic nuclei.

74 ATOMIC AND MOLECULAR PHYSICS↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-CD-207-02: Quantification of Breast Lesion Compositions Using Low-Dose Spectral Mammography: A Feasibility Study

Purpose: To investigate the feasibility of measuring breast lesion composition with spectral mammography using physical phantoms and bovine tissue. Methods: Phantom images were acquired with a spectral mammography system with a silicon-strip based photon-counting detector. Plastic water and adipose-equivalent phantoms were used to calibrate the system for dual-energy material decomposition. The calibration phantom was constructed in range of 2–8 cm thickness and water densities in the range of 0% to 100%. A non-linear rational fitting function was used to calibrate the imaging system. The phantom studies were performed with uniform background phantom and non-uniform background phantom. The breast lesion phantoms (2 cm in diameter and 0.5 cm in thickness) were made with water densities ranging from 0 to 100%. The lesion phantoms were placed in different positions and depths on the phantoms to investigate the accuracy of the measurement under various conditions. The plastic water content of the lesion was measured by subtracting the total decomposed plastic water signal from a surrounding 2.5 mm thick border outside the lesion. In addition, bovine tissue samples composed of 80 % lean were imaged as background for the simulated lesion phantoms. Results: The thickness of measured and known water contents was compared. The rootmean-square (RMS) errors in water thickness measurements were 0.01 cm for the uniform background phantom, 0.04 cm for non-uniform background phantom, and 0.03 cm for 80% lean bovine tissue background. Conclusion: The results indicate that the proposed technique using spectral mammography can be used to accurately characterize breast lesion compositions.

60 APPLIED LIFE SCIENCES↗

Effect of porosity, tissue density, and mechanical properties on radial sound speed in human cortical bone

Purpose: The purpose of this study was to investigate the effect of simultaneous changes in cortical porosity, tissue mineral density, and elastic properties on radial speed of sound (SOS) in cortical bone. The authors applied quantitative pulse-echo (PE) ultrasound techniques that hold much potential especially for screening of osteoporosis at primary healthcare facilities. Currently, most PE measurements of cortical thickness, a well-known indicator of fracture risk, use a predefined estimate for SOS in bone to calculate thickness. Due to variation of cortical bone porosity, the use of a constant SOS value propagates to an unknown error in cortical thickness assessment by PE ultrasound. Methods: The authors conducted 2.25 and 5.00 MHz focused PE ultrasound time of flight measurements on femoral diaphyses of 18 cadavers in vitro. Cortical porosities of the samples were determined using microcomputed tomography and related to SOS in the samples. Additionally, the effect of cortical bone porosity and mechanical properties of the calcified matrix on SOS was investigated using numerical finite difference time domain simulations. Results: Both experimental measurements and simulations demonstrated significant negative correlation between radial SOS and cortical porosity (R{sup 2} ≥ 0.493, p < 0.01 and R{sup 2} ≥ 0.989, p < 0.01, respectively). When a constant SOS was assumed for cortical bone, the error due to variation of cortical bone porosity (4.9%–16.4%) was about 6% in the cortical thickness assessment in vitro. Conclusions: Use of a predefined, constant value for radial SOS in cortical bone, i.e., neglecting the effect of measured variation in cortical porosity, propagated to an error of 6% in cortical thickness. This error can be critical as characteristic cortical thinning of 1.10% ± 1.06% per yr decreases bending strength of the distal radius and results in increased fragility in postmenopausal women. Provided that the cortical porosity can be estimated in vivo, the relationship between radial SOS and cortical porosity can be utilized and a porosity based radial SOS estimate could be implemented to determine cortical thickness. This would constitute a step toward individualized quantitative ultrasound diagnostics of osteoporosis.

60 APPLIED LIFE SCIENCES↗

Double Quarter Wave Crab Cavity Wire Stretching Measurement at BNL

The Double Quarter Wave (DQW) crab cavity is one out of the two crab cavities within Work Package 4 of the LHC (Large Hadron Collider) Hi-Lumi Program, and the RF design of the cavity was originally supported by the US LHC Accelerator Research Program (LARP) and later the LHC Accelerator Upgrade Program (AUP) funded by the DOE High Energy Physics Office in the Office of Science. Brookhaven National Laboratory (BNL) has delivered the successful DQW crab cavity RF design, and worked actively with all. The wire stretching measurement was completed on the prototype DQW crab cavity for operation practice and calibration of the measurement system. Four locations were defined to be on the electrical center plane of the crab cavity, and survey of the wire indicated all are on the same plane. The successful measurement validated the wire stretching system built at Brookhaven National Lab. The offset of the four wire locations to the fitted plane provided the error of the measurement.

43 PARTICLE ACCELERATORS↗

Automatic point Cloud Building Envelope Segmentation (Auto-CuBES) using Machine Learning

Modern retrofit construction practices use 3D point cloud data of the building envelope to obtain the as-built dimensions. However, manual segmentation by a trained professional is required to identify and measure window openings, door openings, and other architectural features, making the use of 3D point clouds labor-intensive. In this study, the Automatic point Cloud Building Envelope Segmentation (Auto-CuBES) algorithm is described, which can significantly reduce the time spent during point cloud segmentation. The Auto-CuBES algorithm inputs a 3D point cloud generated by commonly available surveying equipment and outputs a wire-frame model of the building envelope. Unsupervised machine learning methods were used to identify facades, windows, and doors while minimizing the number of calibration parameters. Additionally, Auto-CuBES generates a heat map of each facade indicating non-planar characteristics that are crucial for the optimization of connections used in overclad envelope retrofits. With a scan resolution of 3 mm, the resulting window dimensions showed a mean absolute error of 4.2 mm compared to manual laser measurements.

Maldonado Puente, Bryan↗

The Physical Nature of Subdwarf A Stars: White Dwarf Impostors

We address the physical nature of subdwarf A-type (sdA) stars and their possible link to extremely low mass (ELM) white dwarfs (WDs). The two classes of objects are confused in low-resolution spectroscopy. However, colors and proper motions indicate that sdA stars are cooler and more luminous, and thus larger in radius, than published ELM WDs. We demonstrate that surface gravities derived from pure hydrogen models suffer a systematic ∼1 dex error for sdA stars, likely explained by metal line blanketing below 9000 K. A detailed study of five eclipsing binaries with radial velocity orbital solutions and infrared excess establishes that these sdA stars are metal-poor ≃1.2 M {sub ⊙} main sequence stars with ≃0.8 M {sub ⊙} companions. While WDs must exist at sdA temperatures, only ∼1% of a magnitude-limited sdA sample should be ELM WDs. We conclude that the majority of sdA stars are metal-poor A–F type stars in the halo, and that recently discovered pulsating ELM WD-like stars with no obvious radial velocity variations may be SX Phe variables, not pulsating WDs.

79 ASTRONOMY AND ASTROPHYSICS↗

First M87 Event Horizon Telescope Results. III. Data Processing and Calibration

We present the calibration and reduction of Event Horizon Telescope (EHT) 1.3 mm radio wavelength observations of the supermassive black hole candidate at the center of the radio galaxy M87 and the quasar 3C 279, taken during the 2017 April 5–11 observing campaign. These global very long baseline interferometric observations include for the first time the highly sensitive Atacama Large Millimeter/submillimeter Array (ALMA); reaching an angular resolution of 25 μas, with characteristic sensitivity limits of ~1 mJy on baselines to ALMA and ~10 mJy on other baselines. The observations present challenges for existing data processing tools, arising from the rapid atmospheric phase fluctuations, wide recording bandwidth, and highly heterogeneous array. In response, we developed three independent pipelines for phase calibration and fringe detection, each tailored to the specific needs of the EHT. The final data products include calibrated total intensity amplitude and phase information. They are validated through a series of quality assurance tests that show consistency across pipelines and set limits on baseline systematic errors of 2% in amplitude and 1° in phase. The M87 data reveal the presence of two nulls in correlated flux density at ~3.4 and ~8.3 Gλ and temporal evolution in closure quantities, indicating intrinsic variability of compact structure on a timescale of days, or several light-crossing times for a few billion solar-mass black hole. These measurements provide the first opportunity to image horizon-scale structure in M87.

79 ASTRONOMY AND ASTROPHYSICS↗

A 15-year record of CO emissions constrained by MOPITT CO observations

Long-term measurements from satellites and surface stations have demonstrated a decreasing trend of tropospheric carbon monoxide (CO) in the Northern Hemisphere over the past decade. Likely explanations for this decrease include changes in anthropogenic, fires, and/or biogenic emissions or changes in the primary chemical sink hydroxyl radical (OH). Using remotely sensed CO measurements from the Measurement of Pollution in the Troposphere (MOPITT) satellite instrument, in situ methyl chloroform (MCF) measurements from the World Data Centre for Greenhouse Gases (WDCGG) and the adjoint of the GEOS-Chem model, we estimate the change in global CO emissions from 2001 to 2015. We show that the loss rate of MCF varied by 0.2 % in the past 15 years, indicating that changes in global OH distributions do not explain the recent decrease in CO. Our two-step inversion approach for estimating CO emissions is intended to mitigate the effect of bias errors in the MOPITT data as well as model errors in transport and chemistry, which are the primary factors contributing to the uncertainties when quantifying CO emissions using these remotely sensed data. Our results confirm that the decreasing trend of tropospheric CO in the Northern Hemisphere is due to decreasing CO emissions from anthropogenic and biomass burning sources. In particular, we find decreasing CO emissions from the United States and China in the past 15 years, and unchanged anthropogenic CO emissions from Europe since 2008. We find decreasing trends of biomass burning CO emissions from boreal North America, boreal Asia and South America, but little change over Africa. In contrast to prior results, we find that a positive trend in CO emissions is likely for India and southeast Asia.

54 ENVIRONMENTAL SCIENCES↗

Fermi LAT Observation of Diffuse Gamma-Rays Produced through Interactions Between Local Interstellar Matter and High Energy Cosmic Rays

Observations by the Large Area Telescope (LAT) on the Fermi mission of diffuse {gamma}-rays in a mid-latitude region in the third quadrant (Galactic longitude l from 200{sup o} to 260{sup o} and latitude |b| from 22{sup o} to 60{sup o}) are reported. The region contains no known large molecular cloud and most of the atomic hydrogen is within 1 kpc of the solar system. The contributions of {gamma}-ray point sources and inverse Compton scattering are estimated and subtracted. The residual {gamma}-ray intensity exhibits a linear correlation with the atomic gas column density in energy from 100 MeV to 10 GeV. The measured integrated {gamma}-ray emissivity is (1.63 {+-} 0.05) x 10{sup -26} photons s{sup -1}sr{sup -1} H-atom{sup -1} and (0.66 {+-} 0.02) x 10{sup -26} photons s{sup -1}sr{sup -1} H-atom{sup -1} above 100 MeV and above 300 MeV, respectively, with an additional systematic error of {approx}10%. The differential emissivity from 100 MeV to 10 GeV agrees with calculations based on cosmic ray spectra consistent with those directly measured, at the 10% level. The results obtained indicate that cosmic ray nuclei spectra within 1 kpc from the solar system in regions studied are close to the local interstellar spectra inferred from direct measurements at the Earth within {approx}10%.

08 HYDROGEN↗

Energy considerations in the Community Atmosphere Model (CAM)

An error in the energy formulation in the Community Atmosphere Model (CAM) is identified and corrected. Ten year AMIP simulations are compared using the correct and incorrect energy formulations. Statistics of selected primary variables all indicate physically insignificant differences between the simulations, comparable to differences with simulations initialized with rounding sized perturbations. The two simulations are so similar mainly because of an inconsistency in the application of the incorrect energy formulation in the original CAM. CAM used the erroneous energy form to determine the states passed between the parameterizations, but used a form related to the correct formulation for the state passed from the parameterizations to the dynamical core. If the incorrect form is also used to determine the state passed to the dynamical core the simulations are significantly different. In addition, CAM uses the incorrect form for the global energy fixer, but that seems to be less important. The difference of the magnitude of the fixers using the correct and incorrect energy definitions is very small.

54 ENVIRONMENTAL SCIENCES↗

Performance Exploration Through Optimistic Static Program Annotations

Compilers are limited by the static information directly or indirectly encoded in the program. Low-level languages, such as C/C++, are considered problematic as their weak type system and relaxed memory semantic allows for various, sometimes non-obvious, behaviors. Since compilers have to preserve the program semantics for all program executions, the existence of exceptional behavior can prevent optimizations that the developer would consider valid and might expect. Analyses to guarantee the absence of disruptive and unlikely situations are consequently an indispensable part of an optimizing compiler. However, such analyses have to be approximative and limited in scope as global and exact solutions are infeasible for any non-trivial program. In this paper, we present an automated tool to measure the effectmissing static information has on the optimizations applied to a given program. The approach generates an optimistically optimized program version which, compared to the original, defines a performance gap that can be closed by better compiler analyses and selective static program annotations. Our evaluation on six already tuned proxy applications for high-performance codes shows speedups of up to 20.6%. This clearly indicates that static uncertainty limits performance. At the same time, we observed that compilers are often unable to utilize additional static information. Thus, manual annotation of all correct static information is therefore not only error prone but also mostly redundant.

Auto Tuning↗

Monitoring of corrosion effects in pipes with multi-mode acoustic signals

Current commercial long-range guided wave inspection and monitoring technologies for pipes usually require establishment of certain specific acoustic modes for wave propagation and use a large number of sensors in a certain geometric arrangement (for example, uniformly-spaced arrays of sensors on a collar, placed around a pipe). This paper, in contrast, presents a long-range corrosion detection method in pipes based on multi-mode guided acoustic waves, generated and received using simple, single-element sensors. In this technique, available guided wave modes in any interrogated zone of the structure are automatically down-selected by the medium, and changes in energy distribution over the selected modes are analyzed through signal processing to monitor material loss or addition. Here, to investigate the feasibility of the proposed method, we have performed both experimental and numerical simulation studies on 50.8-mm (2-in)-diameter schedule-40 carbon steel pipes. In these studies, a linear chirp signal is injected in compression mode, perpendicular to the surface of the pipe, generating multi-mode, multi-directional guided waves that travel within the pipe wall. Corrosion effects in the pipes are simulated numerically and experimentally. To reduce errors in the measurement technique due to changes in the local or global temperature of the measured media, a universal temperature compensation algorithm is introduced. The experimental results show good agreement with simulation results, indicating that the proposed multi-mode wave generation and detection in a pipe could be used for long-range detection and monitoring of corrosion effects, such as pipe wall losses or solid material deposits.

36 MATERIALS SCIENCE↗

Online short-term solar power forecasting

This paper describes a new approach to online forecasting of power production from PV systems. The method is suited to online forecasting in many applications and in this paper it is used to predict hourly values of solar power for horizons of up to 36 h. The data used is 15-min observations of solar power from 21 PV systems located on rooftops in a small village in Denmark. The suggested method is a two-stage method where first a statistical normalization of the solar power is obtained using a clear sky model. The clear sky model is found using statistical smoothing techniques. Then forecasts of the normalized solar power are calculated using adaptive linear time series models. Both autoregressive (AR) and AR with exogenous input (ARX) models are evaluated, where the latter takes numerical weather predictions (NWPs) as input. The results indicate that for forecasts up to 2 h ahead the most important input is the available observations of solar power, while for longer horizons NWPs are the most important input. A root mean square error improvement of around 35% is achieved by the ARX model compared to a proposed reference model. (author)

14 SOLAR ENERGY↗

Insensitivity of the octahedral spherical hohlraum to power imbalance, pointing accuracy, and assemblage accuracy

The random radiation asymmetry in the octahedral spherical hohlraum [K. Lan et al., Phys. Plasmas 21, 0 10704 (2014)] arising from the power imbalance, pointing accuracy of laser quads, and the assemblage accuracy of capsule is investigated by using the 3-dimensional view factor model. From our study, for the spherical hohlraum, the random radiation asymmetry arising from the power imbalance of the laser quads is about half of that in the cylindrical hohlraum; the random asymmetry arising from the pointing error is about one order lower than that in the cylindrical hohlraum; and the random asymmetry arising from the assemblage error of capsule is about one third of that in the cylindrical hohlraum. Moreover, the random radiation asymmetry in the spherical hohlraum is also less than the amount in the elliptical hohlraum. The results indicate that the spherical hohlraum is more insensitive to the random variations than the cylindrical hohlraum and the elliptical hohlraum. Hence, the spherical hohlraum can relax the requirements to the power imbalance and pointing accuracy of laser facility and the assemblage accuracy of capsule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Physics-constrained deep learning of nonlinear normal modes of spatiotemporal fluid flow dynamics

In this study, we present a physics-constrained deep learning method to discover and visualize from data the invariant nonlinear normal modes (NNMs) which contain the spatiotemporal dynamics of the fluid flow potentially containing strong nonlinearity. Specifically, we develop a NNM-physics-constrained convolutional autoencoder (NNM-CNN-AE) integrated with a multi-temporal-step dynamics prediction block to learn the nonlinear modal transformation, the NNMs containing the spatiotemporal dynamics of the flow, and reduced-order reconstruction and long-time future-state prediction of the flow fields, simultaneously. In test cases, we apply the developed method to analyze different flow regimes past a cylinder, including laminar flows with low Reynolds number in transient and steady states (RD = 100) and high Reynolds number flow (RD = 1000), respectively. The results indicate that the identified NNMs are able to reveal the nonlinear spatiotemporal dynamics of these flows, and the NNMs-based reduced-order modeling consistently achieves better accuracy with orders of magnitudes smaller errors in construction and prediction of the nonlinear velocity and vorticity fields, compared to the linear proper orthogonal decomposition (POD) method and the Koopman-constrained-CNN-AE using the same number or dimension of modes. We perform an analysis of the modal energy distribution of NNMs and find that compared to POD modes, the few fundamental NNMs capture a very high level of total energy of the flow, which is advantageous for reduced-order modeling and representation of the complex flows. Finally, we discuss the potentials and limitations of the presented method.

Mechanics↗