Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emerging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Coherent spin states and emergent de Sitter quasinormal modes

As a toy model for the microscopic description of matter in de Sitter space, we consider a Hamiltonian acting on the spin-j representation of SU(2). This is a model with a finite-dimensional Hilbert space, from which quasinormal modes emerge in the large-spin limit. The path integral over coherent spin states can be evaluated at the semiclassical level and from it we find the single-particle de Sitter density of states, including 1/j corrections. Along the way, we discuss the use of quasinormal modes in quantum mechanics, starting from the paradigmatic upside-down harmonic oscillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Emergent supersymmetry in the marginal deformations of $\mathcal{N}=4$ SYM

Here, we study the one loop renormalization group flow of the marginal deformations of $\mathcal{N}=4$ SYM theory using the a-function. We found that in the planar limit some non-supersymmetric deformations flow to the supersymmetric infrared fixed points described by the Leigh-Strassler theory. This means supersymmetry emerges as a result of renormalization group flow.

1/N Expansion↗

Role of dual energy CT to improve diagnosis of non-traumatic abdominal vascular emergencies

Computed tomography angiography (CTA) is the modality of choice to evaluate abdominal vascular emergencies (AVE). CTA protocols are often complex and require acquisition of multiple phases to enable a variety of diagnosis such as acute bleeding, pseudoaneurysms, bowel ischemia, and dissection. With single energy CT (SECT), differentiating between calcium, coagulated blood, and contrast agents can be challenging based on their attenuation, especially when in small quantity or present as a mixture. With dual-energy CT (DECT), virtual monoenergetic (VM) and material decomposition (MD) image reconstructions enable more robust tissue characterization, improve contrast-enhancement, and reduce beam hardening artifacts. This article will demonstrate how radiologists can utilize DECT for various clinical scenarios in assessment of non-traumatic AVE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Renal Ablation for Life-Threatening Hemorrhage from Multiple Capsular Branches During Renal Artery Stenting

A 55-year-old woman underwent bilateral renal artery stent placement with good angiographic result. After the procedure, the patient complained of left flank pain secondary to subcapsular hematoma. Retrospective evaluation of images taken during stent implantation favored the diagnosis of guidewire perforation. Three hours after the procedure, contrast-enhanced computed tomography and subsequent renal angiography showed multifocal extravasations. We performed emergent renal ablation for the treatment of massive bleeding. To our knowledge, this is the first use of transcatheter renal ablation technique for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Endovascular 'Bridge' Treatment for Iliac-Enteric Fistula

Aortic aneurysm has been reported to be the dominant cause of primary iliac-enteric fistula (IEF) in >70% of cases [1]; other less common causes of primary IEF include peptic ulcer, primary aortitis, pancreatic pseudocyst, or neoplastic erosion into an adjacent artery [2, 3]. We describe an unusual case of IEF managed with a staged approach using an endovascular stent-graft as a 'bridge' in the emergency setting to optimize the next elective definitive excision of the lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment in Emergency Setting of Acute Arterial Injuries After Orthopedic Surgery

Purpose: To assess the feasibility and effectiveness of emergency endovascular treatment of acute arterial injuries after orthopedic surgery. Materials and Methods: Fifteen patients (mean age 68.3 years) with acute arterial injuries after orthopedic surgery were observed, in particular, 5 patients with pseudoaneurysm, 9 patients with active bleeding, and 1 patient with arterial dissection. Transarterial embolization (TAE) and positioning of covered and noncovered stents were the treatments performed. Follow-up after stent implantation (mean 36 months) was performed with color Doppler US (CDU) at 1, 3, 6, and 12 months and yearly thereafter. Plain X-ray was performed to evidence dislodgment or fracture of the graft. A minimum of 12 months' follow-up is available after TAE. Results: Immediate technical success was obtained in all cases. No major complications occurred. Overall clinical success rate was 100%. During mean follow-up, stent-graft occlusions did not occurred. No recurrence and/or consequence of TAE was registered during a minimum follow-up of 12 months. Conclusions: Percutaneous treatment is a feasible and safe tool for treating arterial injuries because it can provide fast and definitive resolution of the damage. This low-invasiveness approach can be proposed as first-line treatment in patients with acute injuries after orthopedic surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing Documentation of Critical Imaging Result Follow-up Recommendations in Emergency Department Discharge Instructions

To facilitate follow-up of critical test results across transitions in patient care settings, we implemented an electronic discharge module that enabled care providers to include follow-up recommendations in the discharge instructions. We assessed the impact of this module on documentation of follow-up recommendations for critical imaging findings in Emergency Department (ED) discharge instructions. We studied 240 patients with critical imaging findings discharged from the ED before (n = 80) and after (n = 160) implementation of the module. We manually reviewed hand-written forms and electronic discharge instructions to determine if follow-up recommendations were documented. Follow-up recommendations in ED discharge instructions increased from 60.0% (48/80) to 73.8% (118/160) post-module implementation (p = 0.03), a relative increase of 23%. There was no significant change in the rate of documented critical imaging findings in the discharge instructions (77.5% [62/80] before the intervention and 76.9% [123/160] after the intervention; p = 0.91). Implementation of a discharge module was associated with increased documentation of critical imaging finding follow-up recommendations in ED discharge instructions. However, one in four patients still did not receive adequate follow-up recommendations, suggesting further opportunities for performance improvement exist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Heat Removal System for the Secondary Loop of a Fast Sodium Reactor and its Efficiency Evaluation

An emergency heat removal system (SAOT) that removes heat from the secondary loop of a fast sodium reactor by air cooling the surfaces of the piping and equipment of the heat-sink loops of the secondary loop is described and ways to optimize it are indicated. A method of evaluating the efficiency of such an SAOT is described, and the results of an evaluation for a fast sodium reactor are presented as an example showing that the system can be used in fast sodium reactors of any power capacity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Causal sets and an emerging continuum

Abstract Causal set theory offers a simple and elegant picture of discrete physics. But the vast majority of causal sets look nothing at all like continuum spacetimes, and must be excluded in some way to obtain a realistic theory. I describe recent results showing that almost all non-manifoldlike causal sets are, in fact, very strongly suppressed in the gravitational path integral. This does not quite demonstrate the emergence of a continuum—we do not yet understand the remaining unsuppressed causal sets well enough—but it is a significant step in that direction.

Astronomy & Astrophysics↗

On the emerging potential of quantum annealing hardware for combinatorial optimization

Abstract Over the past decade, the usefulness of quantum annealing hardware for combinatorial optimization has been the subject of much debate. Thus far, experimental benchmarking studies have indicated that quantum annealing hardware does not provide an irrefutable performance gain over state-of-the-art optimization methods. However, as this hardware continues to evolve, each new iteration brings improved performance and warrants further benchmarking. To that end, this work conducts an optimization performance assessment of D-Wave Systems’ Advantage Performance Update computer, which can natively solve sparse unconstrained quadratic optimization problems with over 5,000 binary decision variables and 40,000 quadratic terms. We demonstrate that classes of contrived problems exist where this quantum annealer can provide run time benefits over a collection of established classical solution methods that represent the current state-of-the-art for benchmarking quantum annealing hardware. Although this work does not present strong evidence of an irrefutable performance benefit for this emerging optimization technology, it does exhibit encouraging progress, signaling the potential impacts on practical optimization tasks in the future.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Emergency Cooling of Nuclear Power Plant Reactors With Heat Removal By a Forced-Draft Cooling Tower

The feasibility of heat removal during emergency cooling of a reactor by a forced-draft cooling tower with accumulation of the peak heat release in a volume of precooled water is evaluated. The advantages of a cooling tower over a spray cooling pond are demonstrated: it requires less space, consumes less material, employs shorter lines in the heat removal system, and provides considerably better protection of the environment from wetting by entrained moisture.

42 ENGINEERING↗

Creating Spin-One Fermions in the Presence of Artificial Spin–Orbit Fields: Emergent Spinor Physics and Spectroscopic Properties

We propose the creation and investigation of a system of spin-one fermions in the presence of artificial spin–orbit coupling, via the interaction of three hyperfine states of fermionic atoms to Raman laser fields. We explore the emergence of spinor physics in the Hamiltonian described by the interaction between light and atoms, and analyze spectroscopic properties such as dispersion relation, Fermi surfaces, spectral functions, spin-dependent momentum distributions and density of states. Connections to spin-one bosons and SU(3) systems is made, as well relations to the Lifshitz transition and Pomeranchuk instability are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Skyrmion Emergence Mediated by Antiferromagnetic Interlayer Exchange Coupling

Skyrmions are considered as topologically protected magnetic textures; they are covering a large area of applications. In this work, we studied using micromagnetic simulations the emergence of skyrmions in a nanodisk stacked in a FM/NM/FM multilayer system. We show how the skyrmion is formed through the antiferromagnetic interlayer exchange coupling (IEC). We also show the impact of the IEC on skyrmion size in both layers. We try as a conclusion to identify the range of IEC where skyrmions could exist in such systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Rapid determination of 226 Ra in emergency urine samples

A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226 Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed. The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226 Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226 Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226 Ra with DGA Resin, saving time. 133 Ba was used instead of 225 Ra as tracer to allow immediate counting; however, 225 Ra can still be used as an option. The rapid purification of 226 Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226 Ra, with rapid removal of isobaric interferences.

61 RADIATION PROTECTION AND DOSIMETRY↗

Manufacturing Processes for Permanent Magnets: Part II—Bonding and Emerging Methods

Abstract Permanent magnets produce magnetic fields and maintain the field even in the presence of an opposing magnetic field. They are widely used in electric machines, electronics, and medical devices. Part I reviews the conventional manufacturing processes for commercial magnets, including Nd-Fe-B, Sm-Co, alnico, and ferrite in cast and sintered forms. In Part II, bonding, emerging advanced manufacturing processes, as well as magnet recycling methods are briefly reviewed for their current status, challenges, and future directions.

Cui, Jun (ORCID:0000000179118172)↗

Emerging imaging targets for infiltrative cardiomyopathy: Inflammation and fibrosis

Molecular imaging in infiltrative cardiomyopathies is increasingly penetrating the clinical arena. Current approaches target the infiltrate directly, or its metabolic, physiologic, or functional consequences. Inflammation may not just play a role as the infiltrative mechanism itself. It is also thought to play a key role in the development and progression of heart failure in general, because it promotes the development of tissue fibrosis. The cascade leading from tissue damage to inflammation and further to fibrosis and loss of function has emerged as a therapeutic target. This review focuses (1) on novel tracers of inflammation, which are on the brink of clinical applicability and may be more specific than the gross metabolic marker F-18 deoxyglucose; and (2) on novel biologic imaging targets in fibrosis, which may be exploited for interrogation of the crosstalk between inflammation and loss of contractile function. Ultimately, the success of any novel molecular imaging assay will depend on whether it can be used for successful guidance of novel, targeted therapies aiming at tissue regeneration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗