Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Mitigation of nitrogen vacancy photoluminescence quenching from material integration for quantum sensing

The nitrogen-vacancy (NV) color center in diamond has demonstrated great promise in a wide range of quantum sensing. Recently, there have been a series of proposals and experiments using NV centers to detect spin noise of quantum materials near the diamond surface. This is a rich complex area of study with novel nano-magnetism and electronic behavior, that the NV center would be ideal for sensing. However, due to the electronic properties of the NV itself and its host material, getting high quality NV centers within nanometers of such systems is challenging. Band bending caused by space charges formed at the metal-semiconductor interface force the NV center into its insensitive charge states. Here, we investigate optimizing this interface by depositing thin metal films and thin insulating layers on a series of NV ensembles at different depths to characterize the impact of metal films on different ensemble depths. We find an improvement of coherence and dephasing times we attribute to ionization of other paramagnetic defects. The insulating layer of alumina between the metal and diamond provide improved photoluminescence and higher sensitivity in all modes of sensing as compared to direct contact with the metal, providing as much as a factor of 2 increase in sensitivity, decrease of integration time by a factor of 4, for NV T 1 relaxometry measurements.

36 MATERIALS SCIENCE↗

Quantum Logic Enhanced Sensing in Solid-State Spin Ensembles

We demonstrate quantum logic enhanced sensitivity for a macroscopic ensemble of solid-state, hybrid two-qubit sensors. We achieve over a factor of 30 improvement in the single-shot signal-to-noise ratio, translating to an ac magnetic field sensitivity enhancement exceeding an order of magnitude for time-averaged measurements. Using the electronic spins of nitrogen vacancy (NV) centers in diamond as sensors, we leverage the on-site nitrogen nuclear spins of the NV centers as memory qubits, in combination with homogeneous and stable bias and control fields, ensuring that all of the ~10 9 two-qubit sensors are sufficiently identical to permit global control of the NV ensemble spin states. We find quantum logic sensitivity enhancement for multiple measurement protocols with varying optimal sensing intervals, including XY8 and DROID-60 dynamical decoupling, as well as correlation spectroscopy, using an applied ac magnetic field signal. The results are independent of the nature of the target signal and broadly applicable to measurements using NV centers and other solid-state spin ensembles. Furthermore, this work provides a benchmark for macroscopic ensembles of quantum sensors that employ quantum logic or quantum error correction algorithms for enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal and suprathermal plasma densities in the outer magnetosphere

Using the low-frequency cutoff of electromagnetic noise trapped in the magnetosphere at frequencies above the local plasma frequency, it is now possible to make very accurate, + or - 1%, electron density measurements in the low density region between the magnetopause and plasmapause. This technique for measuring the total plasma density was used, together with measurements of the suprathermal proton intensities with the LEPEDEA instrumentation on the IMP-6 spacecraft, to determine the thermal proton densities in the region between the plasmapause and magnetopause. Although the thermal protons usually account for a significant fraction, approximately 50%, of the total proton density in this region, in some cases, particularly at the larger radial distances the density of the thermal protons sometimes drops to a very small fraction, 5%, of the total density and nearly all of the plasma consists of suprathermal particles.

Gurnett, D. A.↗

Making aerospace technology work for the automotive industry - Introduction

In many cases it has been found that advances made in one technical field can contribute to other fields. An investigation is in this connection conducted concerning subjects from contemporary NASA programs and projects which might have relevance and potential usefulness to the automotive industry. Examples regarding aerospace developments which have been utilized by the automotive industry are related to electronic design, computer systems, quality control experience, a NASA combustion scanner and television display, exhaust gas analyzers, and a device for suppressing noise propagated through ducts. Projects undertaken by NASA's center for propulsion and power research are examined with respect to their value for the automotive industry. As a result of some of these projects, a gas turbine engine and a Stirling engine might each become a possible alternative to the conventional spark ignition engine.

Olson, W. T.↗

Space Shuttle communications RF switch matrix

The Shuttle Orbiter communications equipment includes phase modulation (PM) and frequency modulation (FM) channels. The PM section has the capability of routing high levels of energy (175 W) from any one of four transmitters to any one of four antennas, mutually exclusive. The FM channel uses a maximum of 15-W power routed from either of two transmitters to one of two antennas, mutually exclusive. The paper describes the design and the theory of a logic-controlled RF switch matrix devised for the purposes cited. Both PM and FM channels are computer-controlled with manual overrides. The logic interface is realized with CMOS logic for low power consumption and high noise immunity. The interior of the switch matrix is maintained at a pressure of 15 psi (90% nitrogen, 10% helium) by an electron beam-welded encapsulation. The computational results confirm the viability of the RF switch matrix concept.

Winch, R.↗

CO2 impact ionization-driven plasma instability observed by Pioneer Venus Orbiter at Periapsis

Observations of enhanced ac electric field noise about Pioneer Venus periapsis are shown to be related to spacecraft-generated impact ionization of the ambient CO2. The frequency of the electric field noise is found to peak in the vicinity of the CO2(+) ion plasma frequency and to closely follow the form of the neutral CO2 density profile. When the electric field noise in all channels is normalized by the square root of the CO2 number density, the ratio is constant. Since the impact electron density measured by the Pioneer Venus Langmuir probe, is observed to scale directly with the neutral CO2, the growth of the electric field amplitude is found to be linear in time with a growth rate proportional to the CO2(+) ion plasma frequency. On the basis of these results the impact ionization-driven instability is shown to be the ion acoustic instability. Implications for the lack of observations by Pioneer Venus of reflected-O(+)-driven instabilities, as have been proposed for the space shuttle, are discussed.

Curtis, S. A.↗

Fast shocks at the edges of hot diamagnetic cavities upstream from the earth's bow shock

Recently, several events described as hot expanding diamagnetic cavities have been observed upstream from the earth's bow shock using the ISEE 1 and 2 spacecraft. It has been suggested that fast shocks may form at the edges of some of these events because of the rapid expansion of the cavities. Here, plasma density, temperature, velocity, and total field changes across the edges of several events were examined, and these changes were found to be consistent with the presence of shocks there. The presence of flat-topped electron distributions and occasional electron beams at and down-stream from the edges provides additional evidence for shocks. Plasma wave observations also show shocklike electrostatic noise at the edges of several events. It is concluded that the edges of diamagnetic cavity events are often shocks, with a range of shock strengths similar to that observed in the interplanetary medium. The range of shock strengths may be the result of different convection and/or expansion speeds of the cavities.

Fuselier, S. A.↗

Wave mode identification of electrostatic noise observed with ISEE 3 in the deep tail boundary layer

The characteristics of the VLF electrostatic noise observed with ISEE 3 in the low-latitude boundary layer of distant geomagnetic tail are examined using a display format for the wave dynamic spectra different from that used by Scarf et al. (1984). It is shown that the observed noise is composed of impulsive bursts. The results of the detailed analysis of the noise parameters are used to develop a model of plasma wave behavior in the plasma rest frame. A hypothesis is proposed that the wide frequency extent of the noise spectra is composed of Doppler effects of waves propagating nearly omnidirectionally within the plasma rest frame, which is moving with the electron bulk speed. On the basis of this hypothesis, the wavelength of the observed waves were determined from the width of the frequency extent and the measured electron bulk speed. It is shown that the wavelength ranges from 2 to 8 times the plasma Debye length.

Tsutsui, M.↗

Realization of Ultra-High Spectral Purity with the Opto-Electronic Oscillator

Recent results with the Opto-Electronic Oscillator (OEO) have led to the realization of very high spectral purity. Experimental results have produced a performance characterized by a noise as low as by -50 dBc/Hz at 10 Hz for a 10 GHz OEO. The unit was built in a compact package containing an integrated DFB laser and the modulator. This performance is significant because the oscillator is free running, and since the noise in an OEO is independent of the oscillation frequency, the same result can also be obtained at higher frequencies. The result also demonstrates that high frequency, high performance, low cost, and miniature OEO can be realized with the integrated photonic technology. We have also developed a novel carrier suppression technique to reduce the 1/f phase noise of the oscillator even further. The technique is based on the use of a long fiber delay, in place of the high Q cavity, to implement carrier suppression. Our preliminary experimental results indicate an extra 10 to 20 dB phase noise reduction of the OEO with this novel technique. Further noise reduction beyond this value is expected with improved circuit design and longer reference fiber.

Yao, Steve↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

A compact submillimeter wave transmission / reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 90 dB (60 dB typical), and phase noise is less than +/- 2(deg). By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near real-time imaging capability using only a single pixel.

submillimeter wave imaging↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Champey, Patrick↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Camera↗

Advanced Silicon Avalanche Photodiodes on NASA's Global Ecosystem Dynamics Investigation (GEDI) Mission

Silicon Avalanche Photodiodes (APDs) are used in NASA’s Global Ecosystem Dynamics Investigation (GEDI) which was launched in December 2018 and is currently measuring the Earth’s vegetation vertical structure from the International Space Station. The APDs were specially made for space lidar with a much lower hole-to-electron ionization coefficient ratio (k-factor ~0.008) than that of commercially available silicon APDs in order to reduce the APD excess noise from the randomness of the avalanche gain. A silicon heater resistor was used under the APD chip to heat the device up to 70°C and improve its quantum efficiency at 1064 nm laser wavelength while maintaining a low dark current such that the overall signal to noise ratio is improved. Special APD protection circuits were used to raise the overload damage threshold to prevent device damage from strong laser return by specular surfaces, such as still water bodies, and space radiation events. The APD and a hybrid transimpedance amplifier circuit were hermetically sealed in a package with a sufficiently low leak rate to ensure multi-year operation lifetime in space. The detector assemblies underwent a series of pre-launch tests per NASA Goddard Environmental Verification Standard for space qualification. They have performed exactly as expected with GEDI in orbit. A detailed description of the GEDI detector design, signal and noise model, and test results are presented in this paper.

Sun, Xiaoli↗

Deriving Large Coronal Magnetic Loop Parameters Using LOFAR J Burst Observations

Large coronal loops around one solar radius in altitude are an important connection between the solar wind and the low solar corona. However, their plasma properties are ill-defined, as standard X-ray and UV techniques are not suited to these low-density environments. Diagnostics from type J solar radio bursts at frequencies above 10 MHz are ideally suited to understand these coronal loops. Despite this, J-bursts are less frequently studied than their type III cousins, in part because the curvature of the coronal loop makes them unsuited for using standard coronal density models. We used LOw-Frequency-ARray (LOFAR) and Parker Solar Probe (PSP) solar radio dynamic spectrum to identify 27 type III bursts and 27 J-bursts during a solar radio noise storm observed on 10 April 2019. We found that their exciter velocities were similar, implying a common acceleration region that injects electrons along open and closed magnetic structures. We describe a novel technique to estimate the density model in coronal loops from J-burst dynamic spectra, finding typical loop apex altitudes around 1.3 solar radius. At this altitude, the average scale heights were 0.36 solar radius, the average temperature was around 1 MK, the average pressure was 0.7mdyn cm -2 , and the average minimum magnetic field strength was 0.13 G. We discuss how these parameters compare with much smaller coronal loops.

Jinge Zhang↗

Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space

Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.

Astronomical detectors↗

Single-electron charge transfer into putative Majorana and trivial modes in individual vortices

Majorana bound states are putative collective excitations in solids that exhibit the self-conjugate property of Majorana fermions—they are their own antiparticles. In iron-based superconductors, zero-energy states in vortices have been reported as potential Majorana bound states, but the evidence remains controversial. Here, we use scanning tunneling noise spectroscopy to study the tunneling process into vortex bound states in the conventional superconductor NbSe 2 , and in the putative Majorana platform FeTe 0.55 Se 0.45 . We find that tunneling into vortex bound states in both cases exhibits charge transfer of a single electron charge. Our data for the zero-energy bound states in FeTe 0.55 Se 0.45 exclude the possibility of Yu–Shiba–Rusinov states and are consistent with both Majorana bound states and trivial vortex bound states. Our results open an avenue for investigating the exotic states in vortex cores and for future Majorana devices, although further theoretical investigations involving charge dynamics and superconducting tips are necessary.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Possible explanation for nonthermal radio noise from binary stars.

Radio emission from the binary stars alpha-Sco, beta-Per, and beta-Lyr is interpreted as due to the mass exchange between the components. The electrons in the inflowing stream excite plasma waves near the surface of the receptor star, and these waves generate radio emission. Crude predictions of radio frequency, intensity, and timescales of variation seem compatible with current observations.

Jones, T. W.↗

Statistical Error Analysis on White-Light Filter Ratio Experiments to Measure Electron Parameters

The Filter ratio technique to remotely measure electron temperature and speed using four color filters in visible light and a polarization camera was described in detail in four articles by Reginald et al., Solar physics, (2018, 2019a, 2019b, 2020). In these four articles we quantified the systematic error associated with using models of symmetric corona to interpret results from asymmetric corona. We also showed the criteria applied to select the bandwidths of filters, and the pros and cons of replacing the traditional linear polarizer with a polarization camera to measure pB. What started in 1990s as ground experiments conducted during total solar eclipses that lasted for a few minutes lead to a balloon borne experiment lasting eight hours in 2019 and will blossom into a space experiment on the International Space Station in 2023. Due to constraints on the bandwidths of the four filters, a successful mission requires quantification of the statistical error using Monte Carlo simulation to generate two feasibility profiles, which are unique to the design parameters of the coronagraph, to comprehend the feasibility to measure temperature and speed within the desired temporal and spatial resolutions. For the statistical error analysis, we use modeled K and F corona profiles, representative theoretical diffraction, scattering, and vignetting profiles, assumed efficiencies for lenses, mirrors, and polarizers, assumed detector properties on quantum efficiency, full well depth, dark noise, and read noise, and assumed instrument properties on aperture diameter, solid angle, and pixel resolution. We hope future white-light coronagraphs will exhibit capabilities to measure electron density, temperature, and speed.

Nelson Reginald↗