Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Current Practices in Distribution Utility Resilience Planning for Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using Institute of Electrical and Electronics Engineers (IEEE) 1366-2022, which defines major events as an event that exceeds reasonable design and/or operational limits of the electric power system. Resilience planning is focused on major event days and reliability planning is focused on nonmajor event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on winter storms in which the primary hazards are heavy snowfall, freezing rain, ice, extreme cold, severe wind, and flooding. These hazards can also contribute to generation shortages, resulting in bulk power system impacts that have consequences for the distribution system, such as load shedding. Stand-alone reports focusing on wildfires and nonwinter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UNIFI Specifications for Grid-Forming Inverter-Based Resources (V. 2)

The UNiversal Interoperability for grid-Forming Inverters (UNIFI) Consortium is addressing fundamental challenges facing the integration of grid-forming (GFM) inverters in electric grids alongside rotating machines and other inverter-based resources (IBRs). This document defines a set of UNIFI Specifications for GFM IBRs that provides requirements from both a power system-level as well as functional requirements at the inverter level that are intended to provide means for vendor-agnostic operation of GFM IBRs at any scale in electric power systems. The specifications are clearly identified and attributed to an IBR plant or an IBR unit throughout the document, where applicable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Networked Microgrid Topology Reconfiguration to Promote Fairness in Proactive Load Shedding

Increasing occurrences of natural disasters and grid emergency events consistently challenge the safe and reliable operations of power systems. During such emergency situations, system operators may proactively shed load to mitigate risks. However, uncoordinated implementation of load shedding may disrupt electricity supply and even lead to cascading failures. Meanwhile, it is crucial to address potential biases affecting different customers when executing load shedding. This paper addresses the dynamic topology reconfiguration problem for networked microgrids with distributed energy resources under emergency conditions. Specifically, we propose a novel rolling-horizon optimization model that integrates fairness-aware constraints into the networked microgrid topology reconfiguration. Unlike existing approaches that focus solely on efficiency or apply fairness considerations in static settings, our method explicitly incorporates temporal fairness constraints to restrict repeated or excessive load curtailment for load blocks. Moreover, the fairness-aware constraints are specifically developed for the context of dynamic networked microgrid topology reconfiguration, and are designed to be convex or amenable to linear reformulations, which offers a more tractable alternative to traditional models with non-convex formulations. Numerical studies on a modified IEEE 13-bus system and a larger-sized SMART-DS networked microgrid system demonstrate the performance of the proposed algorithm towards more fairness-aware networked microgrid topology reconfiguration decision-making.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Management System for an Electric Machine With Additively Manufactured Hollow Conductors With Integrated Heat Pipes

Here, this paper discusses steps taken to develop a novel thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal finite element analysis is used to determine optimum heat transfer coefficient of the convective boundaries. For some of the convective boundaries, fin-based surface area enhancement is required to reach a target combined overall heat transfer coefficient and surface area performance (UA). This enhancement is worked out using a combination of the Engineering Equation Solver tool and 3D thermal FEA. The thermal management system's UA, and by extension its specific power, sensitivity to coolant temperature is explored. Temperature distribution plots of optimized machine components are also presented and discussed. Lastly, additional heat pipe testing is carried out to study its maximum heat transfer capability's sensitivity to condenser coolant temperature and configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

A National Roadmap for Grid-Interactive Efficient Buildings

The way electricity is generated and consumed in the US is quickly changing, including in terms of the rapid growth in variable power generation resources and the need for large-scale investments to replace aging infrastructure and modernize the grid. Buildings that coordinate electricity use with grid conditions are a flexible and cost-effective resource to address the evolving power system challenges. Outfitted with smart technologies, GEBs are energy-efficient buildings with smart technologies characterized by the active use of distributed energy resources to optimize energy use for grid services, occupant needs and preferences, and cost reductions in a continuous and integrated way. In doing so, GEBs can play a key role in promoting greater affordability, resilience, environmental performance, and reliability. The report finds that, over the next two decades, GEBs could deliver between $100 and $200 billion in savings to the US power system and cut CO 2 emissions by 80 million tons per year by 2030, or 6% of total power sector CO 2 emissions. The report also provides 14 recommendations for addressing the top barriers to overcome barriers to GEB adoption and deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resilience Plans: State Requirements, Utility Practices, and Utility Plan Template

As of June 2024, 14 states and one city require jurisdictional electric utilities to file resilience plans. Drawing on these requirements and filed plans, this report offers a standard template that states and utilities can consider to improve utility filings for grid resilience plans, either as part of a distribution system plan or as a separate filing. Key elements include a vulnerability assessment, description of proposed resilience programs, and projected costs and rate impacts. While many of these requirements and plans focus on extreme weather hazards, the template also can be used to address additional threats, including cyber and physical attacks and seismic events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Northeast Freight Corridor Charging Plan (Roadmap Report)

Final report produced as part of grant awarded to National Grid. The final report is a roadmap of 39 prioritized sites. These sites would create a minimum viable network of charging infrastructure, enabling the electrification of trucks across the Northeast

02 PETROLEUM↗

Automotive Power Electronics and Electric Machine Thermal Management

The transition to modular and scalable electrified vehicle transportation requires technologies to improve power density within cost and reliability constraints to maximize vehicle platform flexibility. Key research challenges arise due to the limited packaging space, coolant distribution, electrical connections, and ambient temperatures. Challenges include thermal management for compact power-dense electric machines and the associated power electronics for power management within the vehicle. High-temperature silicon and wide-bandgap (WBG) based power electronics systems are of interest to enable compact and efficient electric drive systems. The higher temperatures present packaging challenges for thermal management and reliability. In this work, we provide an overview of research for thermal characteristics of materials, packages and thermal management approaches for enabling compact power dense automotive electric drive systems.

DIRECT ENERGY CONVERSION↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗

Hydrogen-Battery Hybrid Energy System on Repurposed Offshore Platforms for Efficient Clean-Energy Transition

Due to the rising global energy demand and enhanced awareness of the environmental impact of fossil fuels, the Gulf of Mexico, traditionally known for oil extraction, offers a distinct chance to repurpose the existing offshore infrastructure. With the depletion of oil reserves, it is feasible to adapt previously utilized floating platforms for extraction to generate renewable energy, specifically through wind-generated power and hydrogen production. This adaptation seeks to promote a transport system that is more ecologically friendly in the future. Offshore wind turbines serve as the main energy source, with help from battery storage and hydrogen production to enhance the overall system performance, hydrogen creation, fuel, and electricity delivery for sustainable energy production. The system is divided into two distinct cases, each evaluated for cost, performance, and feasibility, with a focus on minimizing both the Levelized Cost of Energy (LCOE) and the Levelized Cost of Hydrogen (LCOH). The first case examines the integration of offshore wind turbines with hydrogen production. Excess electricity generated by wind turbines is directed toward hydrogen production via electrolysis. The hydrogen produced can be used as fuel for vehicles or transported to the shore via pipelines. The second case investigates a technology that combines wind turbines with battery storage. The batteries possess an ability to supply electricity for a continuous duration of 4 hours maximum each day. The main objective is to reduce the LCOE by considering the battery's charging and discharging cycles, together with the uncertain attributes of wind power and battery deterioration. The produced energy can be distributed for onshore applications or utilized for the purpose of offsetting offshore loads such as subsea oil and gas production, transportation, etc. The offshore hydrogen-battery hybrid system is improved via three advanced algorithms, Particle Swarm Optimization (PSO), and Grey Wolf Optimizer (GWO). In Case 1, PSO improves hydrogen production by efficiently managing the electrolyzer’s power consumption, decreasing production costs significantly. Particle Swarm Optimization (PSO) is applied to improve the efficiency of the electrolyzer, reducing production costs and achieving an optimized CAPEX of $240.00 million (from an initial $300.00 million) and OPEX of $9.60 million per year. This system produces 4,720,000 kg of hydrogen annually, with a Levelized Cost of Hydrogen (LCOH) of $6.40/kg and an annual profit of $9.27 million. In Case 2, GWO effectively reduces the overall energy cost by improving the charge-discharge management of batteries, which extends battery life and optimizes their use. The second case focuses on integrating battery storage, optimized using the Grey Wolf Optimizer (GWO), which enhances battery charge-discharge cycles, extending battery life and lowering costs. This system achieves an optimized CAPEX of $204.80 million (from an initial $256.00 million) and OPEX of $9.29 million per year, producing 310883.39 MWh of electricity annually at a Levelized Cost of Energy (LCOE) of $86.13/MWh, with an annual profit of $6.25 million. The implementation of a comprehensive strategy results in a substantial reduction in costs, improved energy efficiency, and a dependable supply of both electric power and hydrogen, emphasizing the benefits of converting offshore oil platforms for clean energy transition. This study explores a clean strategy to enable cost-effective repurposing of offshore O&G platforms. Both cases highlight the economic and technical feasibility of transitioning offshore oil platforms to clean energy systems, demonstrating substantial cost reductions and reliable energy and hydrogen supplies for sustainable energy production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method for modeling battery-temperature-aware EV power profiles utilizing Next-Gen Profile data

With the expected increase in the number of electric vehicles (EVs) on the road in the coming years, it is important that analysis tools are capable of modeling and predicting the expected load on the power grid due to both individual EV charging sessions as well as large populations of vehicles. To do this accurately, the power profile of an EV charge session must be accurately modeled, including for scenarios where the temperature is above or below the ideal, and also take into account the nuances of manufacturer charging preferences. This paper introduces a method that utilizes the data in the Next-Gen Profile (NGP) data collection project to build a model of EV charging that takes into account the variations in charging power that occur due to off-nominal battery temperature and manufacturer preferences that limit power due to cold temperatures or high battery state-of-charge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Electric-field-assisted-sintering of rare-earth oxide dispersion strengthened Fe-Cr-Mo alloys

Oxide dispersion-strengthened (ODS) alloys are widely recognized for their exceptional high-temperature strength, creep resistance, and radiation tolerance, making them indispensable for advanced nuclear reactors, aerospace, and energy systems. Achieving a fine and stable dispersion of oxide nanoparticles is critical, as these particles act as strong barriers to dislocation motion and effective sinks for irradiation-induced defects, ensuring structural integrity under extreme conditions. Here, in this study, Fe–Cr–Mo-based ODS alloys were fabricated via mechanical alloying and consolidated using electric-field-assisted sintering (EFAS) with additions of Y 2 O 3 , La 2 O 3 , and CeO 2 . EFAS processing produced ultrafine-grained microstructures (average grain size <1 μm) with uniformly distributed oxide clusters (2–4 nm). Atom probe tomography revealed that La 2 O 3 -containing alloys exhibited the highest nanoparticle number density, resulting in superior tensile strength compared to yttria- and ceria-bearing counterparts. The combined effect of grain refinement and rare-earth oxide dispersion significantly enhanced mechanical performance, demonstrating the potential of EFAS for developing high-strength ferritic alloys for demanding environments such as nuclear systems.

36 - MATERIALS SCIENCE↗