Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Adaptive resource allocation for surrogate modeling of systems comprised of multiple disciplines with varying fidelity

We present an adaptive algorithm for constructing surrogate models for integrated systems composed of a set of coupled components. With this goal we introduce ‘coupling’ variables with a priori unknown distributions that allow approximations of each component to be built independently. Once built, the surrogates of the components are combined and used to predict system-level quantities of interest (QoI) at a fraction of the cost of interrogating the full system model. We use a greedy experimental design procedure, based upon a modification of Multi-Index Stochastic Collocation (MISC), to minimize the error of the combined surrogate. This is achieved by refining each component surrogate in accordance with its relative contribution to error in the approximation of the system-level QoI. Our adaptation of MISC is a multi-fidelity procedure that can leverage ensembles of models of varying cost and accuracy, for one or more components, to produce estimates of system-level QoI. Several numerical examples demonstrate the efficacy of the proposed approach on systems involving feed-forward and feedback coupling. For a fixed computational budget, the proposed algorithm is able to produce approximations that are orders of magnitude more accurate than approximations that treat the integrated system as a black-box.

97 MATHEMATICS AND COMPUTING↗

RLMolLM: Reinforcement Learning-Enhanced Language Model Framework for Inverse Molecular Design

Inverse molecular design faces significant challenges due to vast chemical space and complex property requirements. While language models show promise for molecular generation, they struggle with validity, multi-property optimization, and structural constraints. This work presents RLMolLM, a reinforcement learning framework combining Proximal Policy Optimization (PPO) with genetic algorithms to address these limitations. Our approach optimizes multiple user-specified properties including quantitative estimates of drug-likeness (QED), synthetic accessibility (SA), and ADMET (absorption, distribution, metabolism, excretion, and toxicity) endpoints without requiring complete model retraining, while maintaining capability for scaffold-constrained generation where specific substructures must be preserved. We outperform state-of-the-art methods for molecular optimization, achieving best QED scores across GDB13, Moses, and Zinc datasets with up to 31% improvement over previous methods while maintaining excellent validity, uniqueness, and novelty metrics. For simultaneous multi-property optimization, our framework achieves substantial improvements in ADMET properties including 4.5-fold reduction in hERG toxicity and enhanced Caco-2 permeability compared to Moses dataset. Under structural constraints, the framework significantly improves molecular validity while preserving scaffolds and effectively optimizing properties. In conclusion, this versatile solution advances pharmaceutical and materials molecular design through effective integration of reinforcement learning and genetic algorithms with multi-property optimization and scaffold preservation.

Genetic algorithms↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks

Moving target defense (MTD) is a defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation using distributed flexible AC transmission system (D-FACTS) devices. However, existing studies neglect to address a fundamental yet critical issue, i.e., the D-FACTS placement, by assuming that all lines are equipped with D-FACTS devices. Here, to tackle this problem, we first derive analytical necessary conditions and requirements on the D-FACTS placement for a complete MTD. Further, we propose sufficient conditions using a graph theory-based topology analysis to ensure that the MTD under the proposed D-FACTS placement has the maximum rank of its composite matrix, which is indicative of the MTD effectiveness. Based on the analytical conditions, we design D-FACTS placement algorithms by using the minimum number of D-FACTS devices to achieve the maximum MTD effectiveness. A novel MTD-based ACOPF model, in which the reactance of D-FACTS lines is introduced as decision variables, is proposed to find a trade-off between the system loss and the MTD effectiveness. Numerical results on 6-bus, IEEE 14-bus, and IEEE 118-bus systems show the efficacy of MTDs using the proposed D-FACTS placement algorithms in maximizing the composite matrix rank and detecting FDI attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Herbaceous Feedstock 2018 State of Technology Report

The U.S. Department of Energy (DOE) promotes the production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the state of technology (SOT). As part of its involvement with this mission, Idaho National Laboratory (INL) completes an annual SOT report for biomass feedstock logistics. This report summarizes supply system impacts of Bioenergy Technologies Office (BETO)-funded research and development efforts at INL and elsewhere (such as the High-Tonnage Feedstock Logistics projects (Webb et al. 2013a, Webb et al. 2013b, Webb et al. 2013c, Webb and Sokhansanj 2014, Sokhansanj et al. 2014) that lead to improvements in feedstock supply systems. These include improvements to and observed performance of innovative harvest and collection methods, storage technologies, transportation and handling approaches, and advanced preprocessing technologies. Biomass quality and variability, and the interface between feedstock quality and conversion performance are key drivers in addition to delivered feedstock cost. In this report, we estimate the benefits of R&D improvements to individual supply system unit operations, and present the status of feedstock logistics technology development for converting biomass into biofuels. These analyses are supported by experimental data where possible, and help to align the SOT relative to the cost goals defined in the Multi-Year Program Plan. The 2018 Herbaceous SOT aligned feedstock logistic design with current biorefinery’s design capacity utilized by biochemical conversion platform. Currently biochemical conversion platform utilizes a 725,000 dry ton/year biorefiney design for the techno economic analysis. Hence, feedstock delivered cost in the 2018 Herbaceous SOT is calculated based on biorefinery’s 725,000 dry ton design capacity instead of 800, 000 dry ton capacity utilized in the 2017 Herbaceous SOT. Biomass availabilities in this SOT were updated to year 2018 data from the 2016 Billion-Ton Report (BT16) (DOE 2016a), with the exception of switchgrass, for which the 2018 Herbaceous SOT utilized the 2019 switchgrass availability data from BT16. The BT16 report (DOE 2016a) does not project switchgrass availability in 2018; the soonest switchgrass is available in the BT16 report is 2019. Therefore, availability of switchgrass for this analysis was that projected for 2019. The 2018 Herbaceous SOT incorporates same technologies utilized in the 2017 Herbaceous SOT. However, a sensitivity analysis is performed to understand the impact of variation of process parameters on those technologies on feedstock logistic cost. New R&D data that shows the variations of process parameters affecting process performance is incorporated in the 2018 SOT to measure the variations in delivered feedstock cost. The 2018 Herbaceous SOT has also provided projected delivered feedstock of 2022 design case based on near term technical target under BETO funded R&D project. Finally, updated biorefinery size of 725,000 dry ton/year was incorporated within least-cost formulation model to select optimal siting and depot scales during optimization of the least cost blend. This modification to the optimization algorithm allows the trade-off between the cost of increased supply radius and the savings from selecting biomass from higher producing counties to be assessed. Such optimization has also showed the economic benefit of decentralized depots in comparison to centralized preprocessing co-located with the biorefinery by decoupling the biorefinery and feedstock locations. The 2018 Herbaceous SOT report documents the current modeled cost of a herbaceous feedstock supply system (from harvest to the pretreatment reactor throat, including grower payment) for hydrocarbon fuel production via biochemical conversion, based on equipment and processes now available or potentially available in the near term. The modeled cost also considers both the required quality and the availability of the biomass resources. The 2018 Herbaceous SOT predicts a modeled delivered feedstock cost of $83.67/dry ton (2016$); this is a $0.23/dry ton (2016$) decrease from the 2017 Herbaceous SOT. The modification of biorefinery’s designed capacity and increased projected biomass availability in the same supply shed contributed to this modeled cost reduction. The least-cost formulation model to optimally site and scale local distributed preprocessing depots also contributed to the cost reduction by considering county-level grower payment and distance from the biorefinery as variables in the optimization algorithm. Sensitivity analysis on various process parameters that affect delivered feedstock cost in the 2018 Herbaceous SOT shows that the delivered cost could varies from $80.45-$88.83/dry ton. The top factors that causes such variations are: effective baling rate, bale density, hammer mill throughput, interest rate and storage dry matter loss.

09 BIOMASS FUELS↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗

Model-Free Voltage Control of Active Distribution System with PVs Using Surrogate Model-Based Deep Reinforcement Learning

Accurate knowledge of the distribution system topology and parameters is required to achieve good voltage control performance, but this is difficult to obtain in practice. This paper proposes a physical-model-free voltage control method based on a surrogate-model-enabled deep reinforcement learning approach. Specifically, a surrogate model is trained in a supervised manner using the recorded limited number of historical data to learn the relationship between the power injections and voltage fluctuations of each node. Then, the deep reinforcement learning algorithm is applied to learn an optimal control strategy from the experiences obtained by continuous interactions with the surrogate model. The proposed method can achieve physical-model-free control of unbalanced distribution network and inform real-time decisions to deal with fast voltage fluctuations caused by the rapid variation of PV generation. Simulation results on an unbalance IEEE 123-bus system show that the proposed method can achieve similar performance as that of perfect physical-model-based approaches while being advantageous over other traditional methods.

active distribution network↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Baryon–Antibaryon Photoproduction off the Proton

The GlueX Experiment at Jefferson Lab uses linearly polarized photon beam to study the photoproduction of light mesons and baryons off a proton target with unprecedented precision. We have observed p¯p photoproduction and, for the first time, ?¯? photoproduction from thresholds up to E = 11.6 GeV. We reproduce the observed kinematic distributions with a phenomenological model that includes t-channel Regge exchange and double Regge exchange. The model uses few parameters to match all the kinematic spectra via an optimization algorithm developed specifically for this purpose. We report the total cross sections of the two reactions, as well as differential cross sections with respect to various momentum transfers and invariant mass spectra of p¯p, ?¯?, p¯? systems which show enhancements right above production thresholds. Furthermore, the beam asymmetries of the p¯p system are extracted from the GlueX data to further probe the nature of the t-channel Regge exchanges. We also report preliminary measurements of the spin polarizations of the individual hyperons. No prominent resonance structure was found in these reaction channels, but the angular distributions and the correlation of longitudinal momenta indicate the existence of multiple production mechanisms. Besides a dominant forward peak in the polar angle of the baryon-antibaryon pair in t-channel production, we see wide-angle antibaryon distributions different from that of the baryon. In the hyperon channel, we see a clear separation between the photoproduction of the ?¯?, p¯? systems.

Li, Hao↗

Tri-Level Scheduling Model Considering Residential Demand Flexibility of Aggregated HVACs and EVs Under Distribution LMP

Residential loads, especially heating, ventilation and air conditioners (HVACs) and electric vehicles (EVs), have great potentials to provide demand flexibility which is an attribute of grid-interactive efficient buildings (GEB). Under this new paradigm, first, EV and HVAC aggregator models are developed in this paper to represent the fleet of GEBs, in which the aggregated parameters are obtained based on a new approach of data generation and least squares parameter estimation (DG-LSPE), which can deal with heterogeneous HVACs. Then, a tri-level bidding and dispatching framework is established based on competitive distribution operation with distribution locational marginal price (DLMP). Furthermore, the first two levels form a bilevel model to optimize the aggregators’ payment and to represent the interdependency between load aggregators and the distribution system operator (DSO) using DLMP, and the third level is to dispatch the optimal load aggregation to all residents by the proposed priority list-based demand dispatching algorithm. Finally, case studies on a modified IEEE 33-Bus system illustrate three main technical reasons of payment reduction due to demand flexibility: load shift, DLMP step changes, and power losses. They can be used as general guidelines for better decision-making for future planning and operation of demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An MILP-Based Distributed Energy Management for Coordination of Networked Microgrids

An MILP-based distributed energy management for the coordination of networked microgrids is proposed in this paper. Multiple microgrids and the utility grid are coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) update their schedules separately. Then, the price signals are updated according to the generation–load mismatch and distributed to MCs and DMS for the next iteration. The iteration continues until the generation–load mismatch is small enough, i.e., the generation and load are balanced under agreed price signals. Through the proposed distributed energy management, various microgrids and the utility grid with different economic, resilient, emission and socio-economic objectives are coordinated with generation–load balance guaranteed and the microgrid customers’ privacy preserved. In particular, a piecewise linearization technique is employed to approximate the augmented Lagrange term in the alternating direction method of multipliers (ADMM) algorithm. Thus, the subproblems are transformed into mixed integer linear programming (MILP) problems and efficiently solved by open-source MILP solvers, which would accelerate the adoption and deployment of microgrids and promote clean energy. The proposed MILP-based distributed energy management is demonstrated through various case studies on a networked microgrids test system with three microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Age of Evapotranspiration: Lower‐Bound Constraints From Distributed Water Fluxes Across the Continental United States

Abstract Unlike streamflow, which can be sampled in aggregate at the catchment outlet, evapotranspiration (ET) is spatially dispersed, challenging large‐scale age estimation. Here, we introduce an approach for constraining the age of ET via mass balance and present the minimum flux‐weighted age of ET across the continental United States using distributed, publicly available water flux data sets. The lower‐bound constraint on ET age can be calculated by assuming that ET is preferentially sourced from the most recent precipitation through a last‐in, first‐out algorithm. From 2012 to 2017, ET was at least several months old across large areas of the western continental United States, including in Mediterranean and (semi‐)arid climate zones and shrub and evergreen needleleaf plant communities. The primary limitation of this approach is that it provides only a minimum flux‐weighted average age to satisfy the mass balance of outgoing fluxes; true ET fluxes are composed of distributions of ages and may be composed of much older water. The primary advantage of the approach is that flux time series of precipitation and ET are sufficient to constrain ET age, and model parameterization is unnecessary. ET ages can be used to validate tracer‐aided and modeling approaches and inform studies of biogeochemistry, water‐rock interactions, and plant water sourcing under drought.

Hahm, W. J.↗

An ion specific continuum model on ionic surfactant's binary phase diagram in aqueous solution

Here, a continuum aggregation model is proposed to account for specific ion effects, enabling accurate phase diagrams calculations for the micellar, cylindrical and lamellar aggregates of sodium/potassium carboxylate surfactants in aqueous solution across a range of temperatures. Three groups of concentrations at distinctive temperatures are fitted to build empirical temperature dependence given the limited availability of relevant experimental measurements. The specific ion effects are manifested in the aggregates' surface tension as well as in the distributions of counter-ions' concentrations in the vicinity of the aggregates. The aggregates' geometric sizes are well-reproduced. The differential evolution algorithm is applied to address boundary conditions of the electrostatic potential, aggregate size optimization as well as the equilibrium of monomers transferring between the aggregate and aqueous region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling extrapolations of nuclear properties with feature selection

Predictions of nuclear properties far from measured data are inherently inaccurate because of uncertainties in our knowledge of nuclear forces and in our treatment of quantum many-body effects in strongly-interacting systems. While the model bias can be directly calculated when experimental data is available, only an estimate can be made in the absence of such measurements. Current approaches to compute the estimated bias quickly lose predictive power when their input variables are taken far from the training region, resulting in uncontrolled uncertainties in applications such as nucleosynthesis simulations. In this letter, we present a novel technique to identify the input variables of machine learning algorithms that can provide robust estimates of model bias. Our process is based on selecting input variables, or features, based on their probability distribution functions across the entire nuclear chart. We illustrate our approach on the problem of quantifying the model bias in nuclear binding energies calculated with Density Functional Theory (DFT). We prove that building model biases with only Z and N as features leads to highly unreliable extrapolations. Conversely, we show that proper feature selection can systematically improve theoretical predictions without increasing uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Holes in Optical Lightning Flashes: Identifying Poorly Transmissive Clouds in Lightning Imager Data

Space-based optical lightning sensors including the lightning imaging sensor (LIS) and geostationary lightning mapper (GLM) are pixelated imagers that detect lightning as transient increases in cloud top illumination. Detection requires optical emissions to escape the cloud top to space with sufficient energy to trigger a pixel on the imaging array. Through scattering and absorption, certain clouds are able to block most light from reaching the instrument, causing a reduction in detection efficiency (DE) and possibly location accuracy (LA). Radiant lightning emissions that illuminate large cloud top areas are used to examine scenarios where clouds block light from reaching orbit. In some cases, these anomalies in the spatial radiance distribution from the lightning pulse lead to “holes” in the optical lightning flash where certain pixels fail to trigger. Such holes are identified algorithmically in the Tropical Rainfall Measuring Mission satellite LIS record and the microphysical properties of the coincident storm region are queried. We find that holes primarily occur in tall (IR T b < 235 K) convection (87%) and overhanging anvil clouds (10%). The remaining 3% of holes occur in moderate-to-weak convection or in clear air breaks between stormclouds. We further demonstrate how an algorithm that assesses the spatial radiance patterns from energetic lightning pulses might be used to construct an optical transmission gridded stoplight product for GLM that could help operators identify clouds with a potentially reduced DE and LA.

54 ENVIRONMENTAL SCIENCES↗

Consistent and reproducible computation of the glass transition temperature from molecular dynamics simulations

In many fields, from semiconductors for opto-electronic applications to ionic liquids (ILs) for separations, the glass transition temperature (Tg) of a material is a useful gauge for its potential use in practical settings. As a result, there is a great deal of interest in predicting Tg using molecular simulations. However, the uncertainty and variation in the trend shift method, a common approach in simulations to predict Tg, can be high. This is due to the need for human intervention in defining a fitting range for linear fits of density with temperature assumed for the liquid and glass phases across the simulated cooling. The definition of such fitting ranges then defines the estimate for the Tg as the intersection of linear fits. We eliminate this need for human intervention by leveraging the Shapiro–Wilk normality test and proposing an algorithm to define the fitting ranges and, consequently, Tg. Through this integration, we incorporate into our automated methodology that residuals must be normally distributed around zero for any fit, a requirement that must be met for any regression problem. Consequently, fitting ranges for realizing linear fits for each phase are statistically defined rather than visually inferred, obtaining an estimate for Tg without any human intervention. The method is also capable of finding multiple linear regimes across density vs temperature curves. We compare the predictions of our proposed method across multiple IL and semiconductor molecular dynamics simulation results from the literature and compare other proposed methods for automatically detecting Tg from density–temperature data. We believe that our proposed method would allow for more consistent predictions of Tg. We make this methodology available and open source through GitHub.

Chemistry↗

Surface Merging Technique to Design GA-Optimized Heat Sinks

High-power density inverters require efficient and small heat dissipation systems. For liquid cooling systems, an effective heat sink design is important to enable higher heat transfer and keep the pressure drop within reasonable limits. A heat sink geometry generated from an extruded, 1D fast Fourier transform can achieve more even temperature distribution and improved heat transfer than a conventional heat sink. Building on this concept, this paper proposes a new heat sink geometry creation algorithm. Instead of one plane profile being extruded, multiple plane profiles, each created from the fast Fourier transform method, are subsequently merged by smooth surfaces along the flow direction of the heat sink. Thus, a 3D heat sink geometry is created that enables 3D coolant flow and efficient heat transfer. The volume of this design was reduced by 50% compared with pin fin heat sinks. Compared with extruded 1D fast Fourier transform heat sinks, the proposed design showed an approximately 5% device temperature reduction and a 20% pressure drop reduction.

Barua, Himel↗