Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Development of Room-temperature CdMnTe Gamma-ray Detectors

CdMnTe materials have wide bandgap, high resistivity, fair electron-transport properties, and good compositional uniformity. All these features make CdMnTe a good candidate for low cost, high-resolution room-temperature gamma-ray detector. Using several techniques available at BNL, we are characterizing CdMnTe as a material for gamma-ray detectors. The consequent improvements in growth, fabrication, and manufacturing techniques for CdMnTe potentially yield a suitable material for sensing devices with lower production costs. Success of this research has the possibility of generating high impact to nuclear nonproliferation with the goal of offering inexpensive highly sensitive gamma spectrometers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Testing of the dual slab verification detector for attended measurements of the BN-350 dry storage casks

The Dual Slab Verification Detector (DSVD) has been developed and built by Los Alamos National Laboratory in cooperation with the International Atomic Energy Agency (IAEA) as part of the dry storage safeguards system for the spent fuel from the BN-350 fast reactor. The detector consists of two rows of {sup 3}He tubes embedded in a slab of polyethylene which has been designed to be placed on the outer surface of the dry storage cask. The DSVD will be used to perform measurements of the neutron flux emanating from inside the dry storage cask at several locations around each cask to establish a neutron 'fingerprint' that is sensitive to the contents of the cask. The sensitivity of the fingerprinting technique to the removal of specific amount of nuclear material from the cask is determined by the characteristics of the detector that is used to perform the measurements, the characteristics of the spent fuel being measured, and systematic uncertainties that are associated with the dry storage scenario. MCNPX calculations of the BN-350 dry storage asks and layout have shown that the neutron fingerprint verification technique using measurements from the DSVD would be sensitive to both the amount and location of material that is present within an individual cask. To confirm the performance of the neutron fingerprint technique in verifying the presence of BN-350 spent fuel in dry storage, an initial series of measurements have been performed to test the performance and characteristics of the DSVD. Results of these measurements will be presented and compared with MCNPX results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial measurements of BN-350 spent fuel in dry storage casks using the dual slab verification detonator

The Dual Slab Verification Detector (DSVD) has been developed, built, and characterized by Los Alamos National Laboratory in cooperation with the International Atomic Energy Agency (IAEA) as part of the dry storage safeguards system for the spent fuel from the BN-350 fast reactor. The detector consists of two rows of 3He tubes embedded in a slab of polyethylene which has been designed to be placed on the outer surface of the dry storage cask. By performing DSVD measurements at several different locations around the outer surface of the DUC, a signature 'fingerprint' can be established for each DUC based on the neutron flux emanating from inside the dry storage cask. The neutron fingerprint for each individual DUC will be dependent upon the spatial distribution of nuclear material within the cask, thus making it sensitive to the removal of a certain amount of material from the cask. An initial set of DSVD measurements have been performed on the first set of dry storage casks that have been loaded with canisters of spent fuel and moved onto the dry storage pad to both establish an initial fingerprint for these casks as well as to quantify systematic uncertainties associated with these measurements. The results from these measurements will be presented and compared with the expected results that were determined based on MCNPX simulations of the dry storage facility. The ability to safeguard spent nuclear fuel is strongly dependent on the technical capabilities of establishing and maintaining continuity of knowledge (COK) of the spent fuel as it is released from the reactor core and either reprocessed or packaged and stored at a storage facility. While the maintenance of COK is often done using continuous containment and surveillance (C/S) on the spent fuel, it is important that the measurement capabilities exist to re-establish the COK in the event of a significant gap in the continuous CIS by performing measurements that independently confirm the presence and content of Plutonium (Pu) in the spent fuel. The types of non-destructive assay (NDA) measurements that can be performed on the spent fuel are strongly dependent on the type of spent fuel that is being safeguarded as well as the location in which the spent fuel is being stored. The BN-350 Spent Fuel Disposition Project was initiated to improve the safeguards and security of the spent nuclear fuel from the BN-350 fast-breeder reactor and was developed cooperatively to meet the requirements of the International Atomic Energy Agency (IAEA) as well as the terms of the 1993 CTR and MPC&A Implementing Agreements. The unique characteristics of fuel from the BN-350 fast-breeder reactor have allowed for the development of an integrated safeguards measurement program to inventory, monitor, and if necessary, re-verify Pu content of the spent fuel throughout the lifetime of the project. This approach includes the development of a safeguards measurement program to establish and maintain the COK on the spent fuel during the repackaging and eventual relocation of the spent-fuel assemblies to a long-term storage site. As part of the safeguards measurement program, the Pu content of every spent-fuel assembly from the BN-350 reactor was directly measured and characterized while the spent-fuel assemblies were being stored in the spent-fuel pond at the BN-350 facility using the Spent Fuel Coincidence Counter (SFCC). Upon completion of the initial inventory of the Pu content of the individual spent-fuel assemblies, the assemblies were repackaged into welded steel canisters that were filled with inert argon gas and held either four or six individual spent-fuel assemblies depending on the type of assembly that was being packaged. This repackaging of the spent-fuel assemblies was performed in order to improve the stability of the spent-fuel assemblies for long-term storage and increase the proliferation resistance of the spent fuel. To maintain the capability of verifying the presence of the spent-fuel assemblies inside the welded steel canisters, measurements were performed on the canisters using the Spent Fuel Attribute Monitor (SPAM), which was a neutron coincidence counter very similar in design to the SFCC, but with a larger operational volume to accommodate the canisters. The analysis of the neutron coincidence data from the measurements of the welded steel canisters using SP AM yielded a Canister Attribute (CA) that was shown to be proportional to the total amount of Pu mass that was present inside the canister and comparable to the CA values that were calculated based on the previous SFCC measurements. The next step in securing the spent fuel from the BN-350 reactor is the packaging of the steel canisters into Dual-Use Casks (DUCs) and the transportation of the DUCs to a remote dry storage site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detector response calibration for the NOvA quasi-elastic cross-section measurement

NOvA is a long-baseline neutrino experiment designed to observe the neutrino oscillation phenomenon of muon neutrinos oscillating into electron neutrinos. The NuMI beam line located at Fermilab produces the muon neutrinos for this observation. The Near and Far Detectors are constructed off-axis of the NuMI beam line and located at Fermilab and northern Minnesota (electron neutrino appearance maximum), respectively. In order to carry out the long-term goals of the experiment, the NOvA Near Detector Prototype (NDOS) was built and commissioned at Fermilab. Its goals are to demonstrate that, using the same materials and technologies as the larger NOvA detectors, we are able to observe neutrino data from the NuMI beam and cosmic ray muons. The cosmic ray muon data were used in the commissioning and it is currently being used in testing of detector response. These data are also being used in the development of reconstruction and calibration techniques to be used in the Near and Far Detectors. Furthermore, the neutrino data acquired are being used in the development and implementation of physics analyses, not only for NDOS data, but also for the first NOvA data. This thesis will discuss the development of the detector response calibration using cosmic ray muon data and its effects on the preliminary charged current quasi-elastic cross-section measurement using beam neutrino data in the NDOS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SCGSR Final Report

Dual phase noble liquid time projection chambers (TPCs) have an unprecedented sensitivity towards dark matter searches and neutrinos, owing to their ability to detect single electrons. When a particle deposits energy into one of these detectors, electrons are released and drifted into a gaseous region of high electric field. In the gas, the electrons are accelerated to produce extra light into what is called an S2 pulse. This light is far easier to detect than the current induced from a single electron. The two widely used elements for noble liquid detectors are Xe and Ar. Xe has a larger chance of being hit by neutrinos or dark matter, but ends with a lower (i.e. harder to detect) energy when struck. However, Ar light is hard to reflect and detect due to its short wavelength which is absorbed by most materials. While one may use TPB to re-emit this light at a longer wavelength, spatial variations of TPB thickness can smear the amount of re-emitted light, and thus cause a poor S2 energy resolution and spatial resolution. Furthermore, a single electron pulse in Ar is spread over a much longer time than one in Xe, which makes it harder to identify single electrons in Ar. The goal of Xe doping is to combine the best aspects of Ar with the best aspects of Xe. More specifically, this means a detector with a larger yield of photons and electrons produced per energy deposition, an ability to collect more of the light given by those signals, and a narrower pulse from the electron signal. During this project, we developed and operated a detector that can overcome the thermodynamic challenges of Xe doping – namely, preventing Xe from freezing. In the first experimental run during this award period, we found that we can achieve at least 5% of Xe in LAr, and measure the Xe concentration in the gas. In the second run, we installed our detector and saw the first S2 pulses in a dual phase Xe doped LAr TPC. With the data we took, we quantified the effect of Xe doping on the detectability of wavelength-shifted light produced in a Xe doped Ar mixture, as well as the single electron pulse shape. While the Ar light has successfully been wavelength shifted, we learned that much to our surprise, Xe doping actually makes the S2 pulse wider before it makes it narrower.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Profile Detector for Breast Specific Gamma Imaging

Jefferson Lab (JLab), Dilon Technologies (Dilon) and Hampton University (HU) entered into a research CRADA project titled: “Low Profile Detector for Breast Specific Gamma Imaging.” Dr. Benjamin Welch, Director of Research and Development/Engineering was the Principal Investigator for the detector project for Dilon. Dr. Nicholas Kenny was the Principal Investigator for the project for HU. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and acted as the chief contact with Dilon and HU. The responsibility of Jefferson Lab was the development and construction of detector instrumentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of MSNDs for Fast-Neutron Detection and the TREAT Hodoscope

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. A key feature of the TREAT reactor core is an open, horizontal channel that allows line-of-sight viewing of test specimens using various instrumentation during steady-state and transient operation. This instrumentation includes the hodoscope, which consists of over 300 steel-collimated channels coupled to Hornyak buttons (and other detectors) for detection of fast neutrons emitted from fission of the test specimen. Posterior analysis can be used to reconstruct fuel motion and other properties from the collimated channel signals. A large-scale effort is underway to develop next generation instrumentation for transient testing at TREAT (and, potentially, other facilities). Work at KSU specifically aims to provide improved detection systems for hodoscope applications. It was initially proposed to adapt KSU-developed Microstructured Semiconductor Neutron Detectors (MSNDs) for use as fast-neutron detectors. The current generation of MSNDs is designed for thermal-neutron detection based on {sup 6}Li and can achieve intrinsic efficiencies nearing 30% owing to the large (n, t) cross section of {sup 6}Li and clever optimization of the geometry. In order to evaluate MSNDs for fast-neutron detection, two approaches were considered: (1) use of a hydrogenous material to thermalize neutrons to exploit the intrinsic efficiencies of current MSNDs, and (2) substitution of a fast-sensitive reactant for {sup 6}Li. The former approach is attractive because it makes use of proven, off-the-shelf technology and leads to reasonable time resolution and efficiency. Unfortunately, use of thermalization leads to prohibitive degradation of spatial resolution. The second approach will require further experimental efforts, but scoping analyses suggest {sup 235}U- or {sup 237}Th-loaded MSNDs may achieve sufficient efficiencies. The rest of this summary examines these issues in more detail. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241}Am) were performed. A homemade algorithm was developed to determine a value which is related to the neutron absorption of the sample with the analysis of the raw detector data. The detector was placed 42 cm away from the neutron source. Distance between detector and the samples was 0.5 cm. At the sample position the fast neutron flux was estimated to 9x10{sup 3} n cm{sup -2} s{sup -1} for a neutron emission of 10{sup 8} n s{sup -1}. The acquisition time was 15 minutes. First neutron radiographs were successfully recorded despite the low detector efficiency and low neutron emission. Analysis of the data shows a correlation between the measured signal and determined neutron absorption. Thus discrimination between different materials of same thicknesses may be achieved. The measurements and results will be presented and discussed in details.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Qualitative comparison of bremsstrahlung X-rays and 800 MeV protons for tomography of urania fuel pellets

We present an assessment of x-rays and proton tomography as tools for studying the time dependence of the development of damage in fuel rods. We also show data taken with existing facilities at Los Alamos National Laboratory that support this assessment. Data on surrogate fuel rods have been taken using the 800 MeV proton radiography (pRad) facility at the Los Alamos Neutron Science Center (LANSCE), and with a 450 keV bremsstrahlung X-ray tomography facility. The proton radiography pRad facility at LANSCE can provide good position resolution (<70 {mu}m has been demonstrate, 20 {mu}m seems feasible with minor changes) for tomography on activated fuel rods. Bremsstrahlung x-rays may be able to provide better than 100 {mu}m resolution but further development of sources, collimation, and detectors is necessary for x-rays to deal with the background radiation for tomography of activated fuel rods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of Diamond Based Devices for Beam Diagnostics

Beamlines at new light sources, such as the National Synchrotron Light Source II will operate at flux levels beyond the saturation level of existing diagnostics, necessitating the development of new devices. Currently, there is no detector which can span the entire flux range that is possible even in a second generation light source and will become crucial for next generation light sources. One new approach is a diamond-based detector that will be able to monitor beam position, flux and timing to much better resolution. Furthermore, this detector also has linear response to flux over 11 orders of magnitude. However, the successful development of the detector requires thorough understanding and optimization of the physical processes involved. We will discuss the new modeling capabilities we have been implementing in the VORPAL 3D code to investigate the effects of charge generation due to absorption of x-ray photons, transport, and charge trapping. We will report results from VORPAL simulations on charge collection and how it depends on applied field, charge trapping, and the energy of absorbed photons.

43 PARTICLE ACCELERATORS↗

The GeantV project: Preparing the future of simulation

Detector simulation is consuming at least half of the HEP computing cycles, and even so, experiments have to take hard decisions on what to simulate, as their needs greatly surpass the availability of computing resources. New experiments still in the design phase such as FCC, CLIC and ILC as well as upgraded versions of the existing LHC detectors will push further the simulation requirements. Since the increase in computing resources is not likely to keep pace with our needs, it is therefore necessary to explore innovative ways of speeding up simulation in order to sustain the progress of High Energy Physics. The GeantV project aims at developing a high performance detector simulation system integrating fast and full simulation that can be ported on different computing architectures, including CPU accelerators. After more than two years of R&D the project has produced a prototype capable of transporting particles in complex geometries exploiting micro-parallelism, SIMD and multithreading. Portability is obtained via C++ template techniques that allow the development of machine- independent computational kernels. Furthermore, a set of tables derived from Geant4 for cross sections and final states provides a realistic shower development and, having been ported into a Geant4 physics list, can be used as a basis for a direct performance comparison.

97 MATHEMATICS AND COMPUTING↗

EIC Software Overview

Development of the EIC project detector "ePIC" is now well underway and this includes the "single software stack" used for simulation and reconstruction. The stack combines several non-experiment-specific packages including ACTS, DD4hep, JANA2, and PODIO. The software stack aims to be forward looking in the era of AI/ML and heterogeneous hardware. A formal decision making process was implemented to choose the components that involved everyone in the collaboration that was interested. This talk will present an overview of the software stack currently used for development of the ePIC detector and on which we expect to execute the experiment.

Lawrence, David↗

EIC Software Overview

Development of the EIC project detector "ePIC" is now well underway and this includes the "single software stack" used for simulation and reconstruction. The stack combines several non-experiment-specific packages including ACTS, DD4hep, JANA2, and PODIO. The software stack aims to be forward looking in the era of AI/ML and heterogeneous hardware. A formal decision making process was implemented to choose the components that involved everyone in the collaboration that was interested. This talk will present an overview of the software stack currently used for development of the ePIC detector and on which we expect to execute the experiment.

Lawrence, David↗

Hunting the Dark Matter with DEAP/CLEAN

The potential of the DEAP/CLEAN program for direct Dark Matter detection to test various dark matter models is illustrated. The scintillation pulse of a noble liquid like Argon or Neon has two well distinguished time constants allowing a very reliable correlation between pulse shape and type of event. This pulse shape discrimination already provides the power of rejecting a background10{sup 8}-10{sup 9} times larger than the signal. MiniCLEAN, a 500 kg LAr detector, is currently under construction, and a 3.6 ton detector, DEAP-3600, under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the ArgoNeuT and MicroBooNE experiments

Liquid Argon (LAr) time projection chambers are a promising technology for future large-scale neutrino detectors. Their spatial resolution and ability to measure dE/dX make them well suited for identifying and measuring the properties of neutrino i nteractions and rejecting background processes. The development of this technology in the United States is taking a staged approach, with current efforts combining research and development and Physics goals in varying amounts. The ArgoNeut experiment, a p rimarily R&D effort, consists of a cryostat containing 0.24 t of LAr. It is currently in the NuMI beam at Fermilab and will take neutrino data this spring. It will provide a test-bed for development of analysis techniques for LAr detectors. The MicroBooNE cryostat will contain 170 t of LAr and will be located in the Booster neutrino beam at Fermilab. MicroBooNE will develop and test processes for building a large LAr detector, as well as make relevant neutrino cross section measurements for future long ba seline neutrino experiments and study the MiniBooNE low energy excess.

Rebel, Brian↗