Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “decelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

970 records · Page 54

Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n'γ) reactions towards lower energies and the isotropic character of scattering of the secondary neutrons may lead to the observed limitation of the length of effective interaction, since a fraction of the secondary neutrons that propagate in the forward direction are not subject to further inelastic scattering because of their substantially lower energy. At these reduced energies, it is the capture cross-section (n, γ) that becomes predominant, resulting in lower detection efficiency. Based on these results, several types of detectors have been envisioned for application in detection systems for nuclear materials. The testing results for one such detector are presented in this work. We have studied the possibility of creation of a composite detector with scintillator granules placed inside a transparent polymer material. Because of the low transparency of such a dispersed scintillator, better light collection conditions are ensured by incorporation of a light guide between the scintillator layers. This guide is made of highly transparent polymer material. The use of a high-transparency hydrogen-containing polymer material for light guides not only ensures optimum conditions of light collection in the detector, but also allows certain deceleration of neutron radiation, increasing its interaction efficiency with the composite scintillation panels; accordingly, the detector signal is increased by 5-8%. When fast neutrons interact with the scintillator material, the resulting inelastic scattering gamma-quanta emerge, having different energies and different delay times with respect to the moment of the neutron interaction with the nucleus of the scintillator material (delay times ranging from 1x10{sup -9} to 1.3x10{sup -6} s). These internally generated gamma-quanta interact with the scintillator, and the resulting scintillation light is recorded by the photo-receiver. Since neutron sources are also strong sources of low-energy gamma-radiation, the use of dispersed ZnSe(Te) scintillator material provides high gamma-radiation detection efficiency in that energy range. This new type of gamma-neutron detector is based on a 'sandwich' structure using a ZnSe composite film and light guide with a fast neutron detection efficiency of about 6%. Its high detection efficiency of low-energy gamma-radiation allows a substantial increase (by an order of magnitude) in the efficiency of detection of neutron sources and transuranic materials by means of simultaneous detection of accompanying gamma-radiation. The design and fabrication technology of this detector allows the creation of gamma-neutron detectors characterized by high sensitivity at relatively low costs (as compared with analogs using oxide scintillators) for portable inspection systems. The sandwich structure can be comprised of any number of plates, with no limitations on thickness or area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Stopping Power of Water for Carbon Ions Using Inverted Doppler Shift Attenuation

Carbon ion therapy has gained importance in cancer treatment due to its locally well confined dose distribution, but there is a significant lack of experimental data which is needed for dose calculations and estimation of biological damage. Since tissue is mainly comprised of water, the energy-dependent stopping power of water is the critical measure. Importantly, previous data gathered from experiments with light ions has been limited to water vapour and ice and neglected water in its liquid phase. Additionally, theoretical models regarding the stopping power cannot yet describe the complex charge transfer interactions of the projectile at velocities in the range of the mean velocity of the valence electrons of the traversed medium. There are also discrepancies in the amount of phase effects concerning water and water vapour cross sections. Despite its importance there exists no experimental data for the stopping power of water for carbon ions in the energy region between 1 MeV and 5 MeV. This may be due to the short track length of carbon ions which makes traditional transmission experiments unfeasible. Therefore a project was launched to measure the stopping power of liquid water for carbon ions in the vicinity of the Bragg peak which corresponds to the energy regime of the maximum stopping power. For this measurement the inverted Doppler shift attenuation method was used. This uses the gamma quanta emitted from excited carbon nuclei which are produced by means of the {sup 12}C(α,α'){sup 12}C* reaction. The recorded γ-spectra contain the information of the projectiles velocity at the time they decay to their ground state and an internal clock provided by the exponential decay law. The deceleration of the projectile is directly connected to the stopping power which can be determined with this method as a function of the projectiles kinetic energy. Further measurements have been carried out to improve the experimental method. The setup and the preliminary results of this study will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Drop Testing of a Container for the Storage, Transport and Disposal of Intermediate Level Waste - 18078

Impact tests were performed, as part of a corresponding container's substantiation, during design development of a shielded container proposed for use at Sellafield for waste retrieval from the First Generation Magnox Storage Pond (FGMSP) in the UK. The mechanical test program comprised a 9 m free drop test onto an unyielding target in a container long lid edge down orientation at ambient conditions. Further, a 0,5 m free drop test onto a punch target was performed. Here, the container was orientated with the lid downwards in a way that the punch, a mild steel bar, impacts a filter lid. The test specimen was instrumented with strain gauges and accelerometers for the drop tests. Transient strains at selected points of the inner and outer container walls, at the shielding lid, as well as at the lid bolts were measured during the container's impact. Furthermore, decelerations of the container body, container lid, and the skip were measured. The complex geometrical changes of the container due to impact were determined by optical 3d- deformation measures using the projected fringes method in combination with multi-image photogrammetry. This paper summarizes the performance of the drop tests and various drop test results in context with the design development as well as aspects regarding the associated Finite Element (FE) analyses and post-test evaluation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

10. Path Modifiers

Toolpaths for additive manufacturing are typically broken into three types: closed-loop, open-loop, and space-filling. Each of these toolpaths serve a specific purpose and are often used in combination to construct an object. The standard implementation of each toolpath commands a constant motion speed and extrusion rate throughout the length of the path. The 3D printer will then make any necessary adjustments during interpolation of the motion, such as accelerating and decelerating when traversing a corner. However, sometimes more finite control and additional pathing can be needed to ensure the successful printing of a path. This chapter will outline path modifiers and how they can be used to enhance the printability of a toolpath by modifying parameters or adding segments.

Roschli, Alex↗

Optics Studies for Multipass Energy Recovery at CEBAF: ER@CEBAF

Energy recovery linacs (ERLs), focus on recycling the kinetic energy of electron beam for the purpose of accelerating a newly injected beam within the same accelerating structure. The rising developments in the super conducting radio frequency technology, ERL technology has achieved several noteworthy milestones over the past few decades. In year 2003, Jefferson Lab has successfully demonstrated a single pass energy recovery at the CEBAF accelerator. Furthermore, they conducted successful experiments with IR-FEL demo and upgrades, as well as the UV FEL driver. This multi-pass, multi-GeV range energy recovery demonstration proposed to be carried out at CEBAF accelerator at Jefferson Lab focuses on demonstrating highest energy recovery in super conducting linac in the low-current range. Continuous electron beam accelerate up to 7.5 GeV within 5-passes and decelerate in the next 5-passes recovering RF energy and dumps at a low energy dump. The beamline optics design for recirculating linacs require special attention to avoid beam instabilities due to RF wakefields. Usually, multi-pass linac beam lines require stronger focusing at lower energies as that is necessary to avoid beam breakup (BBU) instabilities, even with this small beam current. The CEBAF linac optics optimization is focused on balancing over-focusing at higher energies and beta excursions at lower energies. The race-track-shaped geometry of CEBAF accelerator allows its linacs to accommodate multiple energy beams simultaneously, while individual recirculating arcs transporting one beam energy, are shared between accelerating/decelerating beams. For the linac optics optimization process, an extended strategy is used that is originally used in 6-pass Recirculating Linac design of the LHeC, to represent the ten passes through a single linac. Using proper mathematical expressions, linac optics optimization can be achieved with evolutionary genetic algorithms, with Multi-Objective optimization. This thesis introduces a CEBAF optics redesign tailored to accommodates the ER@CEBAF multi-pass ER scheme. The isochronous arcs were retuned to match into optics solutions for optimized 10-pass linacs. Within this work, a single bunch particle tracking analysis presented here focuses on the further improvements of the beamline and beam transportation.

Neththikumara, Isurumali↗

Eddy-current-damped microelectromechanical switch

A microelectromechanical (MEM) device is disclosed that includes a shuttle suspended for movement above a substrate. A plurality of permanent magnets in the shuttle of the MEM device interact with a metal plate which forms the substrate or a metal portion thereof to provide an eddy-current damping of the shuttle, thereby making the shuttle responsive to changes in acceleration or velocity of the MEM device. Alternately, the permanent magnets can be located in the substrate, and the metal portion can form the shuttle. An electrical switch closure in the MEM device can occur in response to a predetermined acceleration-time event. The MEM device, which can be fabricated either by micromachining or LIGA, can be used for sensing an acceleration or deceleration event (e.g. in automotive applications such as airbag deployment or seat belt retraction).

47 OTHER INSTRUMENTATION↗

COMPARISON OF RESPONSE OF 9977 TEST PACKAGES TO ANALYTICAL RESULTS

Each of the hypothetical accident test cases for the 9977 prototypes was included in the battery of finite element structural analyses performed for the package. Comparison of the experimental and analytical results provides a means of confirming that the analytical model correctly represents the physical behavior of the package. The ability of the analytical model to correctly predict the performance of the foam overpack material for the crush test is of particular interest. The dissipation of energy in the crushing process determines the deceleration of the package upon impact and the duration of the impact. In addition, if the analytical model correctly models the foam behavior, the predicted deformation of the package will match that measured on the test articles. This study compares the deformations of the test packages with the analytical predictions. In addition, the impact acceleration and impact duration for the test articles are compared with those predicted by the analyses.

42 ENGINEERING↗

LLE Review 114 (January-March 2008)

This volume of the LLE Review, covering January-March 2008, features 'Cryogenic Targets: Current Status and Future Development', by D. R. Harding, D. H. Edgell, M. D. Wittman, L. M. Elasky, S. J. Verbridge, A. J. Weaver, L. D. Lund, W. Seka, W. T. Shmayda, R. T. Janezic, M. J. Shoup III, M. Moore, R. Junquist, and A. V. Okishev. In this article (p. 57), the authors report on the status of layering cryogenic DT and D{sub 2} targets at LLE for inertial confinement fusion (ICF) targets. This critical effort achieves the important milestone of routinely providing cryogenic DT targets that meet the 1.0-{micro}m (rms) OMEGA ice-quality-surface specification. The best D{sub 2}-ice layers produced so far (rms roughness of 1.1 {micro}m) are approaching the quality typically achieved in DT targets. Efforts to improve the consistency of this process are reported along with investigations supporting the National Ignition Campaign studying issues relevant to indirect-drive and direct-drive cryogenic targets. Additional highlights of recent research presented in this issue include the following: (1) an improved laser speckle smoothing scheme that augments the current NIF 1-D SSD system by using multiple-FM modulators (MultiFM 1-D SSD) (p. 73). With a judicious choice of modulator frequencies, MultiFM 1-D SSD smoothes resonances produced at the higher spatial frequencies and can attain similar or even faster smoothing rates compared to the baseline NIF 2-D SSD system. DRACO simulations have shown that MultiFM 1-D SSD beam smoothing is sufficient for the direct-drive-ignition targets and pulse shapes analyzed thus far, and may even allow reducing the bandwidth enough to eliminate the need for dual-tripler frequency conversion on the NIF. (2) describes a time-gated, monoenergetic proton radiography that provides unique measurements of implosion dynamics of spherical targets in direct-drive inertial confinement fusion (ICF) (p. 81). Radiographs obtained at different implosion times, from acceleration, through coasting, deceleration, to final stagnation, display a comprehensive picture of spherical ICF implosion. Critical information inferred from such images characterizes the spatial structure and temporal evolution of self-generated fields and plasma areal density. (3) describes a single-shot cross-correlator based on a pulse replicator that produces a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test (p. 86). The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm, where a dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps. The dynamic range can be extended with standard optical-density filters and the temporal range extended with larger optics. (4) presents a novel focal-spot diagnostic developed for OMEGA EP that will be used to characterize on-shot focal spots to support high-quality laser-matter interaction experiments (p. 94). The complex fields in the region of the high-energy focus are calculated using high-resolution measurements of the main beam wavefront using the focal-spot diagnostic (FSD) located on the short-pulse diagnostic package and a careful calibration of the transfer wavefront between the FSD instrument and target chamber center. The concept of this calibration procedure is experimentally verified in the Multi-Terawatt (MTW) Laser System, which serves as a development platform for OMEGA EP. A technique based on phase retrieval is employed for the transfer-wavefront calibration since the OMEGA EP infrastructure cannot be replicated in the MTW laser; however, this approach also shows promise as an alternative method for OMEGA EP. (5) report on a systematic study to improve the laser-damage resistance of multilayer high-reflector coatings for use at 351 nm on the OMEGA EP Laser System (p. 103). A series of ha

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deflagration Behavior of PBX 9501 at Elevated Temperature and Pressure

We report the deflagration behavior of PBX 9501 at pressures up to 300 MPa and temperatures of 150-180 C where the sample has been held at the test temperature for several hours before ignition. The purpose is to determine the effect on the deflagration behavior of material damage caused by prolonged exposure to high temperature. This conditioning is similar to that experienced by an explosive while it being heated to eventual explosion. The results are made more complicated by the presence of a significant thermal gradient along the sample during the temperature ramp and soak. Three major conclusions are: the presence of nitroplasticizer makes PBX 9501 more thermally sensitive than LX-04 with an inert Viton binder; the deflagration behavior of PBX 9501 is more extreme and more inconsistent than that of LX-04; and something in PBX 9501 causes thermal damage to 'heal' as the deflagration proceeds, resulting in a decelerating deflagration front as it travels along the sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reaching High-Yield Fusion with a Slow Plasma Liner Compressing a Magnetized Target

Dynamics of the compression of a magnetized plasma target by a heavy liner made of partially ionized high high-Z material is discussed. A 'soft-landing' (shockless) mode of the liner deceleration is analyzed. Conclusion is drawn that such mode is possible for the liners whose thickness at the time of the first contact with the target is smaller than, roughly, 10% of the initial (un-compressed) target radius. A combination of the plasma liner with one or two glide cones allows for a direct access to the area near the center of the reactor chamber. One can then generate plasma target inside the plasma liner at the optimum time. The other advantage of the glide cones is that they can be used to deliver additional fuel to the center of the target near the point of a maximum compression and thereby increase the fusion yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radioisotope Electric Propulsion for Deep Space Sample Return

The need to answer basic questions regarding the origin of the Solar System will motivate robotic sample return missions to destinations like Pluto, its satellite Charon, and objects in the Kuiper belt. To keep the mission duration short enough to be of interest, sample return from objects farther out in the Solar System requires increasingly higher return velocities. A sample return mission involves several complicated steps to reach an object and obtain a sample, but only the interplanetary return phase of the mission is addressed in this paper. Radioisotope electric propulsion is explored in this parametric study as a means to propel small, dedicated return vehicles for transferring kilogram-size samples from deep space to Earth. Return times for both Earth orbital rendezvous and faster, direct atmospheric re-entry trajectories are calculated for objects as far away as 100 AU. Chemical retro-rocket braking at Earth is compared to radioisotope electric propulsion but the limited deceleration capability of chemical rockets forces the return trajectories to be much slower.

33 ADVANCED PROPULSION SYSTEMS↗

Eddy-current-damped microelectromechanical switch

A microelectromechanical (MEM) device is disclosed that includes a shuttle suspended for movement above a substrate. A plurality of permanent magnets in the shuttle of the MEM device interact with a metal plate which forms the substrate or a metal portion thereof to provide an eddy-current damping of the shuttle, thereby making the shuttle responsive to changes in acceleration or velocity of the MEM device. Alternately, the permanent magnets can be located in the substrate, and the metal portion can form the shuttle. An electrical switch closure in the MEM device can occur in response to a predetermined acceleration-time event. The MEM device, which can be fabricated either by micromachining or LIGA, can be used for sensing an acceleration or deceleration event (e.g. in automotive applications such as airbag deployment or seat belt retraction).

47 OTHER INSTRUMENTATION↗

Can we stop the spread of influenza in schools with face masks?

In the absence of a strain-specific vaccine and the potential resistance to antiviral medication, nonpharmaceutical interventions can be used to reduce the spread of an infectious disease such as influenza. The most common non-pharmaceutical interventions include school closures, travel restrictions, social distancing, enforced or volunteer home isolation and quarantine, improved hand hygiene, and the appropriate wearing of face masks. However, for some of these interventions, there are some unavoidable economic costs to both employees and employers, as well as possible additional detriment to society as a whole. For example, it has been shown that school-age children are most likely to be infected and act as sources of infection for others, due to their greater societal interaction and increased susceptibility. Therefore, preventing or at least reducing infections in children is a logical first-line of defense. For this reason, school closures have been widely investigated and recommended as part of pandemic influenza preparedness, and some studies support this conclusion. Yet, school closures would result in lost work days if at least one parent must be absent from work to care for children who would otherwise be at school. In addition, the delay in-academic progress may be detrimental due to mass school absenteeism. In particular, the pandemic influenza guidance by the U.S. Department of Health and Human Services recommends school closures for less than four weeks for Category 2 and 3 pandemics (i.e., similar to the milder 1957 and 1968 pandemics) and one to three months for Category 4 and 5 pandemics (i .e., similar to the 1918 pandemic ). Yet, given the above, it is clear that closing schools for up to three months is unlikely to be a practical mitigation strategy for many families and society. Thus modelers and policy makers need to weigh all factors before recommending such drastic measures, particularly if the agent under consideration typically has low mortality and causes a mild disease. Therefore, we contend that face masks are an effective, practical, non-pharmaceutical intervention that would reduce the spread of disease among school-children, while keeping schools open. Influenza spreads through person-to-person contact, via transmission by large droplets or aerosols (droplet nuclei) produced by breathing, talking, coughing or sneezing, as well as by direct (though most people touch very few others in their daily lives) or indirect (i.e., via fomites) contact. Face masks act as a physical barrier to reduce the amount of potentially infectious inhaled and exhaled particles, although they would not reliably protect the wearer against aerosols; a recent study also demonstrated that they can redirect and decelerate exhaled airflows (when worn by an infected individual) to prevent them from entering the breathing zones of others. Thus, if a whole classroom were to don face masks, disease transmission would be expected to be greatly diminished. Another recent study on face masks and hand hygiene show a 10-50% transmission reduction for influenza-like illnesses. Furthermore, face masks can act as an effective physical reminder and barrier to transmission by preventing the wearer from touching any potentially infectious secretions from their mucous membranes (i.e., from the nose and mouth), which is another mechanism for direct and indirect contact transmission for influenza. A recent systematic review has suggested that wearing masks can be highly effective in limiting the transmission of respiratory infections, such as influenza. Yet, admittedly, the effectiveness of this intervention strategy is highly dependent on compliance (i.e., the willingness to wear the mask in all appropriate situations), which in tum depends on comfort, convenience, fitness, and hygiene. Importantly, masks themselves must not become a source of infection (or reinfection); as such they should be replaced or sanitized daily (where possible) to maximize effectiveness. One solution could be for masks to be touted as fashion accessories, which may be particularly effective in influencing trend-conscious children. With support from the fashion industry and a child-targeted public health campaign, it may be possible to encourage such a trend and make the mask an acceptable fashion item, as well as an important means of infectious disease control.

57↗

The Transverse Linac Optics Design in Multi-pass ERL

In this paper, we analyzed the linac optics design requirement for a multi-pass energy recovery linac (ERL) for arbitrary number of linacs. A set of general formula of constrains for the 2-D transverse matrix is derived to ensure design optics acceptance matching throughout the entire accelerating and decelerating process. Meanwhile, the rest free parameters can be adjusted for fulfilling other requirements or optimization purpose. As an example, we design the linac optics for the future MeRHIC (Medium Energy eRHIC) project and show the optimization for small {beta} function.

43 PARTICLE ACCELERATORS↗

ACE3P Computations of Wakefield Coupling in the CLIC Two-Beam Accelerator

The Compact Linear Collider (CLIC) provides a path to a multi-TeV accelerator to explore the energy frontier of High Energy Physics. Its novel two-beam accelerator concept envisions rf power transfer to the accelerating structures from a separate high-current decelerator beam line consisting of power extraction and transfer structures (PETS). It is critical to numerically verify the fundamental and higher-order mode properties in and between the two beam lines with high accuracy and confidence. To solve these large-scale problems, SLAC's parallel finite element electromagnetic code suite ACE3P is employed. Using curvilinear conformal meshes and higher-order finite element vector basis functions, unprecedented accuracy and computational efficiency are achieved, enabling high-fidelity modeling of complex detuned structures such as the CLIC TD24 accelerating structure. In this paper, time-domain simulations of wakefield coupling effects in the combined system of PETS and the TD24 structures are presented. The results will help to identify potential issues and provide new insights on the design, leading to further improvements on the novel CLIC two-beam accelerator scheme.

43 PARTICLE ACCELERATORS↗

Frequency Control Support of a Doubly-Fed Induction Generator Based on the Torque Limit

This paper proposes a torque limit-based inertial control scheme of a doubly-fed induction generator (DFIG) that supports the frequency control of a power system. If a frequency deviation occurs, the proposed scheme aims to release a large amount of kinetic energy (KE) stored in the rotating masses of a DFIG to raise the frequency nadir (FN). Upon detecting the event, the scheme instantly increases its output to the torque limit and then reduces the output with the rotor speed so that it converges to the stable operating range. To restore the rotor speed while causing a small second frequency dip (SFD), after the rotor speed converges the power reference is reduced by a small amount and maintained until it meets the reference for maximum power point tracking control. The test results demonstrate that the scheme can improve the FN and maximum rate of change of frequency while causing a small SFD in any wind conditions and in a power system that has a high penetration of wind power, and thus the scheme helps maintain the required level of system reliability. The scheme releases the KE from 2.9 times to 3.7 times the Hydro-Quebec requirement depending on the power reference.

24 POWER TRANSMISSION AND DISTRIBUTION↗