Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Comparison of aircraft measurements during GoAmazon2014/5 and ACRIDICON-CHUVA

The indirect effect of atmospheric aerosol particles on the Earth's radiation balance remains one of the most uncertain components affecting climate change throughout the industrial period. The large uncertainty is partly due to the incomplete understanding of aerosol–cloud interactions. One objective of the GoAmazon2014/5 and the ACRIDICON (Aerosol, Cloud, Precipitation, and Radiation Interactions and Dynamics of Convective Cloud Systems)-CHUVA (Cloud Processes of the Main Precipitation Systems in Brazil) projects was to understand the influence of emissions from the tropical megacity of Manaus (Brazil) on the surrounding atmospheric environment of the rainforest and to investigate its role in the life cycle of convective clouds. During one of the intensive observation periods (IOPs) in the dry season from 1 September to 10 October 2014, comprehensive measurements of trace gases and aerosol properties were carried out at several ground sites. In a coordinated way, the advanced suites of sophisticated in situ instruments were deployed aboard both the US Department of Energy Gulfstream-1 (G1) aircraft and the German High Altitude and Long-Range Research Aircraft (HALO) during three coordinated flights on 9 and 21 September and 1 October. Here, we report on the comparison of measurements collected by the two aircraft during these three flights. Such comparisons are challenging but essential for assessing the data quality from the individual platforms and quantifying their uncertainty sources. Similar instruments mounted on the G1 and HALO collected vertical profile measurements of aerosol particle number concentrations and size distribution, cloud condensation nuclei concentrations, ozone and carbon monoxide mixing ratios, cloud droplet size distributions, and downward solar irradiance. We find that the above measurements from the two aircraft agreed within the measurement uncertainties. The relative fraction of the aerosol chemical composition measured by instruments on HALO agreed with the corresponding G1 data, although the total mass loadings only have a good agreement at high altitudes. Furthermore, possible causes of the discrepancies between measurements on the G1 and HALO are examined in this paper. Based on these results, criteria for meaningful aircraft measurement comparisons are discussed.

47 OTHER INSTRUMENTATION↗

CMS centres worldwide: A new collaborative infrastructure

The CMS Experiment at the LHC has established a network of more than fifty inter-connected 'CMS Centres' at CERN and in institutes in the Americas, Asia, Australasia, and Europe. These facilities are used by people doing CMS detector and computing grid operations, remote shifts, data quality monitoring and analysis, as well as education and outreach. We present the computing, software, and collaborative tools and videoconferencing systems. These include permanently running 'telepresence' video links (hardware-based H.323, EVO and Vidyo), Webcasts, and generic Web tools such as CMS-TV for broadcasting live monitoring and outreach information. Being Web-based and experiment-independent, these systems could easily be extended to other organizations. We describe the experiences of using CMS Centres Worldwide in the CMS data-taking operations as well as for major media events with several hundred TV channels, radio stations, and many more press journalists simultaneously around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine

03 NATURAL GAS↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data (Final Report)

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components: (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine.

20 FOSSIL-FUELED POWER PLANTS↗

Better bang for your buck? Comparing savings realization from ESPCs and direct-funded projects

Energy savings performance contracts (ESPCs) offer an opportunity to tremendously scale decarbonization projects, given their paid-from-savings premise. However, prospective customers still question whether ESPC is worth the effort and expense. This study evaluates the savings realization rates of ESPCs compared to direct-funded projects using ENERGY STAR Portfolio Manager (ESPM) benchmarking data. It compares normalized EUIs from ESPM before and after energy conservation projects implemented via ESPC or direct funding in roughly 450 federal buildings. This documented change, ideally a savings, can then be compared to the estimated savings from the energy conservation initiative in order to generate a rough realization rate. Preliminary results indicate a notably greater savings realization rate for the ESPC buildings (median = 105% of estimated savings) than those that underwent direct-funded projects (median = 46%). Because of a shortage of good quality data and the wide range in results, the difference is only significant at the p < 0.20 level. However, the higher savings realization of ESPCs corroborates the authors’ 2014 findings using a different comparison method. With continued soft government funding and regulatory impediments for climate change mitigation in the U.S., financed, paid-from-savings project models (e.g., ESPC, PACE, EaaS and others) certainly merit more attention. This study’s results are particularly compelling (and encouraging) given the country’s likely reliance on these vehicles to address existing building retrofits.

Earni, Shankar↗

Hourly land-use regression models based on low-cost PM monitor data

Highlights: • A network of 23 low-cost PM monitors was deployed across an urban area. • Land use regression models predict the hourly intra-urban PM variations. • Coefficients of determination for hourly PM predictions ranged 0.66–0.76. • Low-cost PM monitor data need to be carefully evaluated before use. • The combination of low-cost monitors and modeling provides useful PM estimates. Land-use regression (LUR) models provide location and time specific estimates of exposure to air pollution and thereby improve the sensitivity of health effects models. However, they require pollutant concentrations at multiple locations along with land-use variables. Often, monitoring is performed over short durations using mobile monitoring with research-grade instruments. Low-cost PM monitors provide an alternative approach that increases the spatial and temporal resolution of the air quality data. LUR models were developed to predict hourly PM concentrations across a metropolitan area using PM concentrations measured simultaneously at multiple locations with low-cost monitors. Monitors were placed at 23 sites during the 2015/16 heating season. Monitors were externally calibrated using co-located measurements including a reference instrument (GRIMM particle spectrometer). LUR models for each hour of the day and weekdays/weekend days were developed using the deletion/substitution/addition algorithm. Coefficients of determination for hourly PM predictions ranged from 0.66 and 0.76 (average 0.7). The hourly-resolved LUR model results will be used in epidemiological studies to examine if and how quickly, increases in ambient PM concentrations trigger adverse health events by reducing the exposure misclassification that arises from using less time resolved exposure estimates.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-237: The Imaging and Radiation Oncology Core (IROC) Cooperatives Activities Supporting the NCI’s National Clinical Trial Network

Purpose: The Imaging and Radiation Oncology Core (IROC) Cooperative has been active for the past two years supporting the National Clinical Trial Network and the details of that support are reported. Methods: There are six QA centers (Houston, Ohio, Philadelphia-RT, Philadelphia-DI, Rhode Island, St. Louis) providing an integrated RT and DI quality control program in support of the NCI’s clinical trials. The QA Center’s efforts are focused on assuring high quality data for clinical trials designed to improve the clinical outcomes for cancer patients worldwide. This program is administered through five core services: site qualification, trial design support, credentialing, data management, and case review. Results: IROC currently provides core support for 172 NCTN trials with RT, DI and RT/DI components. Many of these trials were legacy trial from the previous cooperative group program. IROC monitors nearly 1800 RT photon and 20 proton institutions. Over 28,000 beams outputs were monitored with 8% of the sites requiring repeat audits due to beam out of criteria. As part of credentialing, 950 QA phantoms have been irradiated, 515 imaging modalities evaluated and almost 4000 credentialing letters have been issued. In just year 2, 5290 RT and 4934 DI patient datasets were received (many using TRIAD) by IROC QA Centers to be prepared for review. During the past 2 years, a total of 6300 RT cases and 19,000 DI image sets were reviewed by IROC technical staff. To date, IROC has published 36 manuscripts. Conclusion: The QA services provided by IROC are numerous and are continually being evaluated for effectiveness, harmonized across all NCTN Groups and administered in an efficient and timely manner to enhance accurate and per protocol trial data submission. These efforts increase each NCTN Group’s ability to derive meaningful outcomes from their clinical trials. This work was supported by DHHS NIH grant 5U24CA180803.

60 APPLIED LIFE SCIENCES↗

Commissioning of Robotic Inspection and Automated Analysis System for Assay of Gas Diffusion Piping - 19500

Robotic, in-pipe, nondestructive assay (NDA) is a revolutionary and important means for measuring, analyzing, and reporting radioactive holdup deposits in enrichment piping. This innovation promises vast advantages for efficiency, safety, and cost savings. Payoff, however, lies in utilization much more than innovation. Crossing that threshold from a technical capability to an everyday tool occurs only after rigorous commissioning, adoption, and infusion. This must meet the highest standard, and there can be no compromise. Certification of a new NDA technology must meet the highest standards for quality, safety, and efficacy. Prior to this work, there was no precedent of procedure and method for certification of a robotic methodology for this purpose. The best of robotics had not certified NDA. The best of NDA had not certified robotics. Hence, a great deal of discovery, resourcefulness, and collaboration contributed to this success. This paper chronicles the first-of-kind chartering, co-development, testing, documentation, and site integration that certified this trailblazing in-pipe, robotic NDA. Commissioning had to demonstrate and certify end-to-end NDA automation from robot traversal to computer analysis to report generation of contaminated process piping at the Portsmouth, Ohio gaseous diffusion facility. This was a rigorous campaign of tests, evaluations, and documentation. Highlights included multiple tests in four elevated pipes exercised the gamut of NDA and robotic capabilities. Each of the four test pipes presented a unique loading of U-235. The tests demonstrated operations in both 30- inch and 42-inch diameter pipes with varying lengths and terminated by a variety of valves and fittings. Tests in a fifth pipe at floor level demonstrated deployment and applicability for pipes at this ground height and robot recognition of another fitting type. All operations, calibration, deployment, auto-reporting, and analysis were handled by Portsmouth site personnel. These tests concluded a series of component-level acceptance tests which certified all constituent technologies and operational features. Test metrics included comparison of reported to ground truth results and assessment of data quality from quality assurance and replicate measurement comparison. Beyond the radiometry associated with any NDA method, this unique commissioning path exercised and evaluated all the robotic features that are intrinsic to automation. These include odometry, geometric modeling, autonomy, remote launch and recovery, and end-to-end data flow. Each of these required verification and certification. These evaluations were first-of-kind for the decommissioning community, requiring innovation and resourcefulness in their own right. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Standardized Architecture for a Mega-Biobank Phenomic Library: The Million Veteran Program (MVP)

Electronic health records (EHRs) provide a wealth of data for phenotype development in population health studies, and researchers invest considerable time to curate data elements and validate disease definitions. The ability to reproduce well-defined phenotypes increases data quality, comparability of results and expedites research. In this paper, we present a standardized approach to organize and capture phenotype definitions, resulting in the creation of an open, online repository of phenotypes. This resource captures phenotype development, provenance and process from the Million Veteran Program, a national mega-biobank embedded in the Veterans Health Administration (VHA). To ensure that the repository is searchable, extendable, and sustainable, it is necessary to develop both a proper digital catalog architecture and underlying metadata infrastructure to enable effective management of the data fields required to define each phenotype. Our methods provide a resource for VHA investigators and a roadmap for researchers interested in standardizing their phenotype definitions to increase portability.

Knight, Kathryn↗

Standardized Architecture for a Mega-Biobank Phenomic Library: The Million Veteran Program (MVP)

Electronic health records (EHRs) provide a wealth of data for phenotype development in population health studies, and researchers invest considerable time to curate data elements and validate disease definitions. The ability to reproduce well-defined phenotypes increases data quality, comparability of results and expedites research. In this paper, we present a standardized approach to organize and capture phenotype definitions, resulting in the creation of an open, online repository of phenotypes. This resource captures phenotype development, provenance and process from the Million Veteran Program, a national mega-biobank embedded in the Veterans Health Administration (VHA). To ensure that the repository is searchable, extendable, and sustainable, it is necessary to develop both a proper digital catalog architecture and underlying metadata infrastructure to enable effective management of the data fields required to define each phenotype. Our methods provide a resource for VHA investigators and a roadmap for researchers interested in standardizing their phenotype definitions to increase portability.

Knight, Kathryn↗

Screening tool to evaluate the vulnerability of down-gradient receptors to groundwater contaminants from uncapped landfills

Highlights: • A spreadsheet-based risk screening tool for groundwater affected by landfills is presented. • Domenico solute transport equations are used to estimate downgradient contaminant concentrations. • Landfills are categorized as presenting high, moderate or low risks. • Analysis of parameter sensitivity and examples of the method’s application are given. • The method has value to regulators and those considering redeveloping closed landfills. - Abstract: A screening tool for quantifying levels of concern for contaminants detected in monitoring wells on or near landfills to down-gradient receptors (streams, wetlands and residential lots) was developed and evaluated. The tool uses Quick Domenico Multi-scenario (QDM), a spreadsheet implementation of Domenico-based solute transport, to estimate concentrations of contaminants reaching receptors under steady-state conditions from a constant-strength source. Unlike most other available Domenico-based model applications, QDM calculates the time for down-gradient contaminant concentrations to approach steady state and appropriate dispersivity values, and allows for up to fifty simulations on a single spreadsheet. Sensitivity of QDM solutions to critical model parameters was quantified. The screening tool uses QDM results to categorize landfills as having high, moderate and low levels of concern, based on contaminant concentrations reaching receptors relative to regulatory concentrations. The application of this tool was demonstrated by assessing levels of concern (as defined by the New Jersey Pinelands Commission) for thirty closed, uncapped landfills in the New Jersey Pinelands National Reserve, using historic water-quality data from monitoring wells on and near landfills and hydraulic parameters from regional flow models. Twelve of these landfills are categorized as having high levels of concern, indicating a need for further assessment. This tool is not a replacement for conventional numerically-based transport model or other available Domenico-based applications, but is suitable for quickly assessing the level of concern posed by a landfill or other contaminant point source before expensive and lengthy monitoring or remediation measures are taken. In addition to quantifying the level of concern using historic groundwater-monitoring data, the tool allows for archiving model scenarios and adding refinements as new data become available.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H02 WETLAND TREATMENT SYSTEM WATER CHEMISTRY SAMPLING AND RESULTS REPORT

The H-02 Wetland Treatment System (Figure 1) is used to remove heavy metals (e.g., copper and zinc) from the H-Area process and storm water discharge. Routine flow enters an equalization basin by inlets on either the east (Location 1) or west end (Location 2). The west end influent constitutes 75% of the average flow into the basin which has an average residence time of approximately 3 days at low pool (i.e., 120 gal/min. through a volume of 0.5 million gallons). The water then exits via the basin outlet on the east end. Next, the water flows to a splitter box (Location 3) which evenly separates the flow between two wetland cells for a design flow of 60 gal/min. per wetland cell with a residence time in the cell of approximately 2 days. The wetland effluent is then combined (Location 4) and flows through a spillway before reaching the National Pollution Discharge Elimination System (NPDES) measurement point near Road 4. During initial operation, it was observed that the pH of the water leaving the equalization basin was elevated compared to the influent pH. Furthermore, the elevated pH remained through the wetland cells so that there was an average pH of 10 leaving the wetland cells during the daytime which exceeds the upper NPDES limit of 8.5. The purpose of the current study was to evaluate the cause of the increase in pH within the equalization basin of the H-02 Wetland Treatment System. Possible mechanisms included algal activity and inorganic chemistry interactions (e.g., interactions with the clay and/or bentonite liner). Water quality parameters were evaluated throughout the H-02 Wetland Treatment system and over time in order to determine the cause of high pH values measured in the basin and wetland. Fluctuations in dissolved oxygen (DO) and accompanying changes in pH would be expected in systems where algae are an influencing factor. An unexpected increase or decrease in the concentration of inorganic substances may indicate operational changes or an inorganic chemistry influence on pH. In addition, alternative methods to alleviate or mitigate the pH increase were evaluated. This study documents the results of sampling activities undertaken and conveys the analytical results along with suggestions for operation of the H-02 Wetland Treatment System. The water samples collected and the water quality data generated from this activity are for analytical purposes only, and as such, were not collected in support of compliance activities.

54 ENVIRONMENTAL SCIENCES↗

SU-G-BRB-04: Automated Output Factor Measurements Using Continuous Data Logging for Linac Commissioning

Purpose: Linac commissioning is a time consuming and labor intensive process, the streamline of which is highly desirable. In particular, manual measurement of output factors for a variety of field sizes and energy greatly hinders the commissioning efficiency. In this study, automated measurement of output factors was demonstrated as ‘one-click’ using data logging of an electrometer. Methods: Beams to be measured were created in the recording and verifying (R&V) system and configured for continuous delivery. An electrometer with an automatic data logging feature enabled continuous data collection for all fields without human intervention. The electrometer saved data into a spreadsheet every 0.5 seconds. A Matlab program was developed to analyze the excel data to monitor and check the data quality. Results: For each photon energy, output factors were measured for five configurations, including open field and four wedges. Each configuration includes 72 fields sizes, ranging from 4×4 to 20×30 cm{sup 2}. Using automation, it took 50 minutes to complete the measurement of 72 field sizes, in contrast to 80 minutes when using the manual approach. The automation avoided the necessity of redundant Linac status checks between fields as in the manual approach. In fact, the only limiting factor in such automation is Linac overheating. The data collection beams in the R&V system are reusable, and the simplified process is less error-prone. In addition, our Matlab program extracted the output factors faithfully from data logging, and the discrepancy between the automatic and manual measurement is within ±0.3%. For two separate automated measurements 30 days apart, consistency check shows a discrepancy within ±1% for 6MV photon with a 60 degree wedge. Conclusion: Automated output factor measurements can save time by 40% when compared with conventional manual approach. This work laid ground for further improvement for the automation of Linac commissioning.

43 PARTICLE ACCELERATORS↗

Plate Impact and Penetration at the Ballistic Launch Tube: Experiments

This report details the data collected from plate impact experiments performed at the Ballistics Launch Tube (BLT) in May 2019. The experiments consisted of 62 shots of copper projectiles (cylindrical and ogive) impacting 1/4", 1/2", and 3/4" aluminum plates at varying velocities. An additional 14 shots of copper cylinders on a 1" steel plate were fired at varying velocities as a Taylor anvil test. We recorded videos of the impact events and resulting fragmentation using a multi-view system of three high speed cameras. The purpose of these tests was to collect high quality data from the multi-view camera system and create digital representations of the deformed target, projectile and fragments. This data is intended to be used as validation data set for high fidelity simulation codes. This report covers the experimental setup, diagnostics, and collected data. Data processing and analysis are underway and will be discussed in a separate report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

A proposed U.S./China theoretical/experimental collaborative effort on baryon resonance extraction

In this paper we discuss the reasons for our work towards establishing a new collaboration between Jefferson Lab (JLab) and the Institute of High Energy Physics (IHEP) in Beijing. We seek to combine experimentalists and theorists into a dedicated group focused on better understanding the current and future data from JLab and from the Beijing Electron Positron Collider (BEPC). Recent JLab results on the extraction of single- and double-polarization observables in both the 1{pi}- and 2{pi}-channel show their high sensitivity to small production amplitudes and therefore their importance for the extraction of resonance parameters. The Beijing Electron Spectrometer (BES) at the BEPC has collected high statistics data on J/{Psi} production. Its decay into baryon-antibaryon channels offers a unique and complementary way of probing nucleon resonances. The CEBAF Large Acceptance Spectrometer, CLAS, has access to N* form factors at high Q{sup 2}, which is advantageous for the study of dynamical properties of nucleon resonances, while the low-background BES results will be able to provide guidance for the search for less-dominant excited states at JLab. Moreover, with the recently approved experimental proposal Nucleon Resonance Studies with CLAS12 and the high-quality data streaming from BES-III and CLAS, the time has come for forging a new Trans-Pacific collaboration of theorists and experimentalists on NSTAR physics.

43 PARTICLE ACCELERATORS↗

THE BARYON OSCILLATION SPECTROSCOPIC SURVEY OF SDSS-III

The Baryon Oscillation Spectroscopic Survey (BOSS) is designed to measure the scale of baryon acoustic oscillations (BAO) in the clustering of matter over a larger volume than the combined efforts of all previous spectroscopic surveys of large-scale structure. BOSS uses 1.5 million luminous galaxies as faint as i = 19.9 over 10,000 deg{sup 2} to measure BAO to redshifts z < 0.7. Observations of neutral hydrogen in the Ly{alpha} forest in more than 150,000 quasar spectra (g < 22) will constrain BAO over the redshift range 2.15 < z < 3.5. Early results from BOSS include the first detection of the large-scale three-dimensional clustering of the Ly{alpha} forest and a strong detection from the Data Release 9 data set of the BAO in the clustering of massive galaxies at an effective redshift z = 0.57. We project that BOSS will yield measurements of the angular diameter distance d{sub A} to an accuracy of 1.0% at redshifts z = 0.3 and z = 0.57 and measurements of H(z) to 1.8% and 1.7% at the same redshifts. Forecasts for Ly{alpha} forest constraints predict a measurement of an overall dilation factor that scales the highly degenerate D{sub A} (z) and H {sup -1}(z) parameters to an accuracy of 1.9% at z {approx} 2.5 when the survey is complete. Here, we provide an overview of the selection of spectroscopic targets, planning of observations, and analysis of data and data quality of BOSS.

79 ASTRONOMY AND ASTROPHYSICS↗

Ocelot: An Interactive, Efficient Distributed Compression-As-a-Service Platform With Optimized Data Compression Techniques

Large volumes of data generated by scientific simulations, genome sequencing, and other applications need to be moved among clusters for data collection/analysis. Data compression techniques have effectively reduced data storage and transfer costs. However, users' requirements on interactively controlling both data quality and compression ratios are non-trivial to fulfill. Here, we propose a novel Compression-as-a-Service (CaaS) platform called Ocelot with four important contributions: (1) It offers real-time visualization, interactive compression, and transfer of scientific datasets. (2) It incorporates new strategies for compressing diverse types of datasets more effectively than traditional methods. (3) It provides an effective method for estimating the compression ratio and execution time of compression tasks. (4) Experiments on multiple real-world datasets on geographically distributed computers show that Ocelot can significantly improve data transfer efficiency with a performance gain of more than 10x in computing clusters with relatively slow networks.

compression as a service (CaaS)↗