Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Effect of laser radiation wavelength and reepithelization process on optical quality of eye cornea after laser correction of vision

The optical quality of the eye cornea surface after performing the laser vision correction essentially depends on the characteristic roughness scale (CRS) of the ablated surface, which is mainly determined by the absorption coefficient of the cornea at the laser wavelength. Thus, in the case of using an excimer ArF laser (λ = 193 nm) the absorption coefficient is equal to 39000 cm{sup -1}, the darkening by the dissociation products takes place, and the depth of the roughness relief can be as large as 0.23 mm. Under irradiation with the Er : YAG laser (λ = 2940 nm) the clearing is observed due to the rupture of hydrogen bonds in water, and the relief depth exceeds 1 μm. It is shown that the process of reepithelization that occurs after performing the laser vision correction leads to the improvement of the optical quality of the cornea surface. (interaction of laser radiation with matter)

74 ATOMIC AND MOLECULAR PHYSICS↗

Adaptive correction of the image of an incoherent source object

The paper examines the operation of an optical system forming an image of an incoherent source object under conditions of atmospheric noise. The effect of atmospheric turbulence is considered. The calculations are performed in the Fresnel – Huygens approximation. The characteristics of the image for ‘long’ and ‘short’ exposures are investigated. The issues related to the adaptive correction of the general light wavefront slopes are discussed. The limits of applicability of phase adaptive correction using a reference source are shown. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peculiarities of adaptive phase correction of optical wave distortions under conditions of ‘strong’ intensity fluctuations

The reason for the loss of efficiency of adaptive phase correction in the propagation of optical waves in a turbulent atmosphere under conditions of ‘strong’ intensity fluctuations is experimentally explained for the first time. Based on the data from experiments conducted on both horizontal and vertical atmospheric paths, we have found that intensity fluctuations begin to significantly affect phase measurements when the coherence radius of the optical wave becomes less than the radius of the first Fresnel zone. Under these conditions, the main meter of adaptive optics systems, i. e. the Hartmann sensor, no longer provides correct measurements of the phase distribution in the presence of deep amplitude modulation. Based on the study of the behaviour of the mode components of the phase fluctuations reconstructed from the results of measurements in various operating regimes, we have found that, first of all, the amplitudes of the lowest modes of phase fluctuation expansion (tilts, defocusing, and astigmatism) are distorted, which, as the analysis shows, is very different from the regime of weak fluctuations. (atmospheric optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive system for wavefront correction of the PEARL laser facility

The results of the operation of a wavefront correction system based on a deformable bimorph mirror of the PEARL subpetawatt laser facility are presented. An improvement in the quality of focusing of laser radiation, which led to an increase in the Strehl ratio from 0.3 to 0.6, is demonstrated. The features of the compensation for phase distortions of the wavefront in the case of a low pulse repetition rate, as well as the correct allowance for the noise of the CCD camera when calculating the Strehl ratio are investigated. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CORRECTING FOR INTERPLANETARY SCATTERING IN VELOCITY DISPERSION ANALYSIS OF SOLAR ENERGETIC PARTICLES

To understand the origin of Solar Energetic Particles (SEPs), we must study their injection time relative to other solar eruption manifestations. Traditionally the injection time is determined using the Velocity Dispersion Analysis (VDA) where a linear fit of the observed event onset times at 1 AU to the inverse velocities of SEPs is used to derive the injection time and path length of the first-arriving particles. VDA does not, however, take into account that the particles that produce a statistically observable onset at 1 AU have scattered in the interplanetary space. We use Monte Carlo test particle simulations of energetic protons to study the effect of particle scattering on the observable SEP event onset above pre-event background, and consequently on VDA results. We find that the VDA results are sensitive to the properties of the pre-event and event particle spectra as well as SEP injection and scattering parameters. In particular, a VDA-obtained path length that is close to the nominal Parker spiral length does not imply that the VDA injection time is correct. We study the delay to the observed onset caused by scattering of the particles and derive a simple estimate for the delay time by using the rate of intensity increase at the SEP onset as a parameter. We apply the correction to a magnetically well-connected SEP event of 2000 June 10, and show it to improve both the path length and injection time estimates, while also increasing the error limits to better reflect the inherent uncertainties of VDA.

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigating challenges in aberration-corrected electron-beam lithography on electron-opaque substrates

Aberration-corrected electron-beam lithography (AC-EBL) using ultra-thin electron transparent membranes has achieved single-digit nanometer resolution in two widely used electron-beam resists: poly (methyl methacrylate) (PMMA) and hydrogen silsesquioxane. On the other hand, AC-EBL implementation on thick, electron-opaque substrates is appealing for conventional top-down fabrication of quantum devices with nanometer-scale features. To investigate the performance of AC-EBL on thick substrates, we measured the lithographic point spread function of a 200 keV aberration-corrected scanning transmission electron microscope by defining both positive and negative patterns in PMMA thin films, spin-cast on thick SiO 2 /Si substrates. We present the problems encountered during pre-exposure beam focusing and discuss methods to overcome them. In addition, applying some of these methods using commercial 50 nm thick SiN X membranes with thick Si support frames, we printed arrays of holes in PMMA with pitches around 26 nm on SiN X /Si substrates with increasing Si thickness. Here, our results show that proximity effects from even 50 nm thick SiN X membranes limit hole arrays to 20 nm pitch; however, down to this limit, the effect of the substrate thickness on the pattern quality is minimal. These results highlight the need for novel resists less susceptible to proximity effects, or resists which can be used directly, after development, as the dielectric material in periodic gates in 2D quantum devices.

2D quantum devices↗

A consistency relation for the observed galaxy bispectrum and the local non-Gaussianity from relativistic corrections

We obtain a consistency relation for the observed three-point correlator of galaxies. It includes relativistic effects and it is valid in the squeezed limit. Furthermore, the consistency relation is non-perturbative and can be used at arbitrarily small scales for the short modes. Our results are also useful to compute the non-linear relativistic corrections which induce a signal in the observations that might be misinterpreted as primordial non-Gaussianity with a local shape. We estimate the effective local non-Gaussianity parameter from the relativistic corrections. The exact value depends on the redshift and the magnification bias. At redshift of z=1.5, in the absence of magnification bias, we get f{sup GR}{sub NL} ≅ − 3.0 .

79 ASTRONOMY AND ASTROPHYSICS↗

On thermal corrections to near-threshold annihilation

We consider non-relativistic ''dark'' particles interacting through gauge boson exchange. At finite temperature, gauge exchange is modified in many ways: virtual corrections lead to Debye screening; real corrections amount to frequent scatterings of the heavy particles on light plasma constituents; mixing angles change. In a certain temperature and energy range, these effects are of order unity. Taking them into account in a resummed form, we estimate the near-threshold spectrum of kinetically equilibrated annihilating TeV scale particles. Weakly bound states are shown to 'melt' below freeze-out, whereas with attractive strong interactions, relevant e.g. for gluinos, bound states boost the annihilation rate by a factor 4 ... 80 with respect to the Sommerfeld estimate, thereby perhaps helping to avoid overclosure of the universe. Modestly non-degenerate dark sector masses and a way to combine the contributions of channels with different gauge and spin structures are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-interaction-free electric dipole polarizabilities for atoms and their ions using the Fermi-Löwdin self-interaction correction

The static electric dipole polarizability of a system is a measure of the binding of its electrons. In density functional theory calculations, this binding is weakened by the presence of unphysical self-interaction in the density functional approximation (DFA), leading to overestimates of polarizabilities. In this work, to investigate this systematically we compare polarizabilities for the atoms from H to Ar and their anions and cations calculated in several DFAs and the corresponding self-interaction-corrected (SIC) DFAs with experiment and with high-level quantum chemistry reference values. The SIC results are obtained using the Fermi-Löwdin orbital self-interaction correction (FLO-SIC) method. Removing self-interaction generally leads to smaller polarizabilities that agree significantly better with reference values. In conclusion, we find that FLO-SIC improves the performance of the local spin density approximation and the generalized gradient approximation (GGA) for polarizabilities to a quality that is comparable to so-called rung 4 functionals, but slightly degrades the performance of the strongly constrained and appropriately normed meta-GGA functional.

74 ATOMIC AND MOLECULAR PHYSICS↗

Single-shot quantum error correction in intertwined toric codes

We construct a subsystem code in three dimensions that exhibits single-shot error correction in a user-friendly and transparent way. As this code is a subsystem version of coupled toric codes, we call it the intertwined toric code (ITC). Although previous codes share the property of single-shot error correction, the ITC is distinguished by its physically motivated origin, geometrically straightforward logical operators and errors, and a simple phase diagram. The code arises from three-dimensional (3D) stabilizer toric codes in a way that emphasizes the physical origin of the single-shot property. In particular, starting with two copies of the 3D toric code, we add check operators that provide for the confinement of pointlike excitations without condensing the loop excitations. Geometrically, the bare and dressed logical operators in the ITC derive from logical operators in the underlying toric codes, creating a clear relationship between errors and measurement outcomes. The syndromes of the ITC resemble the syndromes of the single-shot code by Kubica and Vasmer, allowing us to use their decoding schemes. We also extract the phase diagram corresponding to ITC and show that it contains the phases found in the Kubica-Vasmer code. Lastly, we suggest various connections to Walker-Wang models and measurement-based quantum computation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination

Flat-field calibration of X-ray area detectors is a challenge due to the inability to generate an X-ray flat-field at the selected photon energy the beamline operates at, which has a strong influence on the measurement behavior of the detector. A method is presented in which a simulated flat-field correction is calculated without flat-field measurements. Instead, a series of quick scattering measurements from an amorphous scatterer is used to calculate a flat-field response. The ability to rapidly obtain a flat-field response allows for recalibration of an X-ray detector as needed without significant expenditure of either time or effort. Area detectors on the beamlines used, such as the Pilatus 2M CdTe, PE XRD1621 and Varex XRD 4343CT, were found to have detector responses that drift slightly over timescales of several weeks or after exposure to high photon flux, suggesting the need to more frequently recalibrate with a new flat-field correction map.

47 OTHER INSTRUMENTATION↗

Closed-Form Solution for Synchrophasor Data Correction under GPS Spoofing Attack

Phasor Measurement Units (PMUs) are increasingly being deployed to augment monitoring, protection and control applications in the power grid. PMUs rely on the Global Positioning System (GPS) for generation of time-synchronized and accurate measurements. However, civilian GPS signals, being unencrypted, are susceptible to GPS spoofing attacks (GSA). Hence ensuring the integrity of GPS-timing dependent synchrophasor data has become critical. In this paper, a closed-form analytical solution for estimating the GSA phase shift has been proposed and integrated to the spoofing detection & correction framework. Extensive simulations have been performed in order to verify the accuracy of the solution in determining the location and the phase shift of the compromised PMU. Time domain dynamic simulations presented in this paper demonstrate the applicability of the proposed solution for near-real-time detection of GSA, and this will enable faster detection and correction of phase angles of compromised synchrophasor data.

Synchrophasor, PMUs, GPS, Spoofing, Data Correctio↗

Attack Identification and Correction for PMU GPS Spoofing in Unbalanced Distribution Systems

Due to the vulnerability of civilian global positioning system (GPS) signals, the accuracy of phasor measurement units (PMUs) can be greatly compromised by GPS spoofing attacks (GSAs), which introduce phase shifts into true phase angle measurements. Focusing on simultaneous GSAs for multiple PMU locations, this paper proposes a novel identification and correction algorithm in distribution systems. A sensitivity analysis of state estimation residuals on a single GSA phase angle is firstly implemented. An identification algorithm using a probing technique is proposed to determine the locations of spoofed PMUs and the ranges of GSA phase shifts. Based on the identification results, these GSA phase shifts are determined via an estimation algorithm that minimizes the mismatch between measurements and system states. Finally, with the attacked PMU data corrected, the system states are recovered. Simulations in unbalanced IEEE 34-bus and 123-bus distribution systems demonstrates the efficiency and accuracy of the proposed method.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-98: An Analysis of TG-51 Electron Beam Calibration Correction Factor Uncertainty

Purpose: To analyze the uncertainty of the TG-51 electron beam calibration correction factors for farmer type ion chambers currently used by institutions visited by IROC Houston. Methods: TG-51 calibration data were collected from 181 institutions visited by IROC Houston physicists for 1174 and 197 distinct electron beams from modern Varian and Elekta accelerators, respectively. Data collected and analyzed included ion chamber make and model, nominal energy, N{sub D,w}, I{sub 50}, R{sub 50}, k’R{sub 50}, d{sub ref}, P{sub gr} and pdd(d{sub ref}). k’R{sub 50} data for parallel plate chambers were excluded from the analysis. Results: Unlike photon beams, electron nominal energy is a poor indicator of the actual energy as evidenced by the range of R{sub 50} values for each electron beam energy (6–22MeV). The large range in R{sub 50} values resulted k’R{sub 50} values with a small standard deviation but large range between maximum value used and minimum value (0.001–0.029) used for a specific Varian nominal energy. Varian data showed more variability in k’R{sub 50} values than the Elekta data (0.001–0.014). Using the observed range of R{sub 50} values, the maximum spread in k’R{sub 50} values was determined by IROC Houston and compared to the spread of k’R{sub 50} values used in the community. For Elekta linacs the spreads were equivalent, but for Varian energies of 6 to 16MeV, the community spread was 2 to 6 times larger. Community P{sub gr} values had a much larger range of values for 6 and 9 MeV values than predicted. The range in Varian pdd(d{sub ref} ) used by the community for low energies was large, (1.4–4.9 percent), when it should have been very close to unity. Exradin, PTW Roos and PTW farmer chambers N{sub D,w} values showed the largest spread, ≥11 percent. Conclusion: While the vast majority of electron beam calibration correction factors used are accurate, there is a surprising spread in some of the values used.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-390: Evaluation of Heterogeneity Corrections Made by RayStation Treatment Planning

Purpose: To examine the agreement between absorbed doses calculated by RayStation treatment planning algorithm to those measured with gafchromic film and ion chamber when the photon beam is perturbed by attenuation or lateral scatter of lung material. Methods: A gafchromic EBT2 film was placed in the center of a 30×30×20 cm{sup 3} solid water phantom with a 5 cm lung slab placed at 10 cm depth. The film was irradiated at SSD = 100 cm with a 6 MV photon beam, 10×10 and 5×5 cm{sup 2} field sizes and with the beam parallel to the film and lung slab. A CT was performed to the phantom arrangement for RayStation dose calculation. The films were scanned in an Epson 10000X flatbed scanner and analyzed using the red channel, 16 bits, 76 dpi. PDD curves at the central axis and profiles at dmax were also measured in water using a CC13 (0.13 CC) ion chamber. Measurements and calculation of PDD curves at the central axis and profiles at dmax and 20 cm depth were compared using the criteria suggested by the AAPM Task Group # 53. Results: The PDD curves measured with gafchromic film and those measured in water with ion chamber agree with the ones calculated by RayStation within the uncertainty of the measurements which is within 3%. The passing rate values of the measured and calculated profiles for the 2 field sizes are within 94% for both at dmax and at 20 cm depth. Conclusion: Raystation dose calculation engine models inhomogeneity corrections. Differences between the calculated PDD curves and profiles and those measured with gafchromic film are within the uncertainty of the measurements and inside of the agreement tolerance suggested by TG53. Therefore, RayStation treatment planning has an acceptable algorithm to correct dose delivered by photon beams perturbed by lung tissue.

60 APPLIED LIFE SCIENCES↗

SU-E-T-414: Experimental Correction of High-Z Electrode Effect in Mini-Ionization Chambers for Small Beam Dosimetry

Purpose: To correct for the over-response of mini-ionization chambers with high-Z central electrodes. The hypothesis is that by applying a negative/reverse voltage, it is possible to suppress the signal generated in the high-Z central electrode by low-energy photons. Methods: The mini-ionization chambers used in the experiments were a PTW-31014, PTW-31006 and IBA-CC01. The PTW-31014 has an aluminum central electrode while the PTW-31006 and IBA-CC01 have a steel one. Total scatter factors (Scp) were measured for a 6 MV photon beam down to a square field size of 0.5 cm. The measurements were performed in water at 10 cm depth with SAD of 100 cm. The Scp were measured with the dosimeters with +400V bias voltage. In the case of the PTW-31006 and IBA-CC01, the measurements were repeated with −400V bias voltage. Also, the field factors in water were calculated with Monte Carlo simulations for comparison. Results: The measured Scp at +400V with the PTW-31006 and IBA-CC01 detectors were in agreement within 0.2% down to a field size of 1.5 cm. Both dosimeters shown a systematic difference about 2.5% with the Scp measured with the PTW-31014 and the Monte Carlo calculated field factors. The measured Scp at −400V with the PTW-31006 and IBA-CC01 detectors were in close agreement with the PTW-31014 measured Scp and the field factors within 0.3 and 1.0%, respectively. In the case of the IBA-CC01 it was found a good agreement (1%) down to field size of 1.0 cm. All the dosimeters shown differences up to 17% between the measured Scp and the field factor for the 0.5 cm field size. Conclusion: By applying a negative/reverse voltage to the mini-ionization chambers with high-Z central electrode it was possible to correct for their over-response to low energy photons.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPE phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of diagnostic CT beams. The results obtained here are being used to refine both simulations and design of calorimeter core components.

60 APPLIED LIFE SCIENCES↗

Attenuation correction in emission tomography using the emission data—A review

The problem of attenuation correction (AC) for quantitative positron emission tomography (PET) had been considered solved to a large extent after the commercial availability of devices combining PET with computed tomography (CT) in 2001; single photon emission computed tomography (SPECT) has seen a similar development. However, stimulated in particular by technical advances toward clinical systems combining PET and magnetic resonance imaging (MRI), research interest in alternative approaches for PET AC has grown substantially in the last years. In this comprehensive literature review, the authors first present theoretical results with relevance to simultaneous reconstruction of attenuation and activity. The authors then look back at the early history of this research area especially in PET; since this history is closely interwoven with that of similar approaches in SPECT, these will also be covered. We then review algorithmic advances in PET, including analytic and iterative algorithms. The analytic approaches are either based on the Helgason–Ludwig data consistency conditions of the Radon transform, or generalizations of John’s partial differential equation; with respect to iterative methods, we discuss maximum likelihood reconstruction of attenuation and activity (MLAA), the maximum likelihood attenuation correction factors (MLACF) algorithm, and their offspring. The description of methods is followed by a structured account of applications for simultaneous reconstruction techniques: this discussion covers organ-specific applications, applications specific to PET/MRI, applications using supplemental transmission information, and motion-aware applications. After briefly summarizing SPECT applications, we consider recent developments using emission data other than unscattered photons. In summary, developments using time-of-flight (TOF) PET emission data for AC have shown promising advances and open a wide range of applications. These techniques may both remedy deficiencies of purely MRI-based AC approaches in PET/MRI and improve standalone PET imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗