Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Comparative study with two reduced test facilities for air-cooled RCCS scaling law

Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL) conducted steady-state tests at constant heat flux conditions to investigate the scale effect on heat removal behavior of the air-cooled Reactor Cavity Cooling System (RCCS). Two differently scaled-down test facilities were used in this study, KAERI’s ¼ scale with 4.0-m cavity height, and ANL’s ½ scale with 6.8-m cavity height. Two scaling laws were proposed to simulate the radiation across the cavity and the buoyancy-driven duct flow in the riser, respectively. The test matrix for KAERI and ANL test facilities focused on the scaling effect of the heated riser length with constant heat flux at the PMR200 RCCS design. The test results showed that mixed convection in the riser duct is an important factor for accurately extrapolating the thermo-fluid behavior in the prototype from the test results in the scale-down facilities. The system analysis code, GAMMA+, with improved heat transfer models predicted fairly well the air-cooled RCCS test data from two facilities. GAMMA+ analysis results showed that the predicted radiation fractions on the heated plate in the scale-down test conditions were larger than those on the reactor vessel in the prototype. The scaling law for air-cooled RCCS was improved by considering the mixed convection in the riser duct and the same radiation fraction on the heated plate. The mixed convection effect was calculated by the height ratio. The same radiation fraction provided a conservative extrapolation from the scale-down test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Air Cooling for High Temperature Power Electronics (Presentation)

Current emphasis on developing high-temperature power electronics, including wide-bandgap materials such as silicon carbide and gallium nitride, increases the opportunity for a completely air-cooled inverter at higher powers. This removes the liquid cooling system for the inverter, saving weight and volume on the liquid-to-air heat exchanger, coolant lines, pumps, and coolant, replacing them with just a fan and air supply ducting. We investigate the potential for an air-cooled heat exchanger from a component and systems-level approach to meet specific power and power density targets. A proposed baseline air-cooled heat exchanger design that does not meet those targets was optimized using a parametric computational fluid dynamics analysis, examining the effects of heat exchanger geometry and device location, fixing the device heat dissipation and maximum junction temperature. The CFD results were extrapolated to a full inverter, including casing, capacitor, bus bar, gate driver, and control board component weights and volumes. Surrogate ducting was tested to understand the pressure drop and subsequent system parasitic load. Geometries that met targets with acceptable loads on the system were down-selected for experimentation. Nine baseline configuration modules dissipated the target heat dissipation, but fell below specific power and power density targets. Six optimized configuration modules dissipated the target heat load, exceeding the specific power and power density targets. By maintaining the same 175 degrees C maximum junction temperature, an optimized heat exchanger design and higher device heat fluxes allowed a reduction in the number of modules required, increasing specific power and power density while still maintaining the inverter power.

30 DIRECT ENERGY CONVERSION↗

Probabilistic constrained Bayesian inversion for transpiration cooling

Abstract To enable safe operations in applications such as rocket combustion chambers, the materials require cooling to avoid material damage. Here, transpiration cooling is a promising cooling technique. Numerous studies investigate possibilities to simulate and evaluate the complex cooling mechanism. One naturally arising question is the amount of coolant required to ensure a safe operation. To study this, we introduce an approach that determines the posterior probability distribution of the Reynolds number using an inverse problem and constraining the maximum temperature of the system under parameter uncertainties. Mathematically, this chance inequality constraint is dealt with by a generalized polynomial chaos expansion of the system. The posterior distribution will be evaluated by different Markov chain Monte Carlo based methods. A novel method for the constrained case is proposed and tested among others on two‐dimensional transpiration cooling models.

97 MATHEMATICS AND COMPUTING↗

Catastrophic Cooling Instability in Optically Thin Plasmas

The solar corona is the prototypical example of a low-density environment heated to high temperatures by external sources. The plasma cools radiatively, and because it is optically thin to this radiation, it becomes possible to model the density, velocity, and temperature structure of the system by modifying the MHD equations to include an energy source term that approximates the local heating and cooling rates. The solutions can be highly inhomogeneous and even multiphase because the well-known linear instability associated with this source term, thermal instability, leads to a catastrophic heating and cooling of the plasma in the nonlinear regime. Here we show that there is a separate, much simpler linear instability accompanying this source term that can rival thermal instability in dynamical importance. The stability criterion is the isochoric one identified by Parker (1953), and we demonstrate that cooling functions derived from collisional ionization equilibrium are highly prone to violating this criterion. If catastrophic cooling instability can act locally in global simulations, then it is an alternative mechanism for forming condensations, and due to its nonequilibrium character, it may be relevant to explaining a host of phenomena associated with the production of cooler gas in hot, low density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Different Cooling Rates on the Corrosion Behavior of High-Carbon Pearlitic Steel

The present work discusses the effect of pearlitic morphology on the corrosion behavior of high-carbon fully pearlitic steel in 3.5% NaCl solution. Four different types of pearlitic steels (furnace-cooled, as-received, air-cooled and forced-air-cooled) consisting of coarse, medium, fine and very fine microstructures, respectively, were tested. Electrochemical behavior of these steels was studied with the help of dynamic and linear polarization and AC impedance spectroscopic tests. The corrosion resistance improved with fineness of the microstructure in general. However, with further reduction in interlamellar spacing beyond a limit, the corrosion resistance reduced slightly. Formation of homogeneous distribution of microgalvanic cells between cementite and ferrite lamellae of fine pearlitic steel improved the corrosion resistance. However, entanglement of the lamellae of pearlite in very fine pearlitic structure as well as breaking of cementite lamellae due to finer pearlitic colonies was attributed to the higher corrosion of the forced-air-cooled steel as compared to the air-cooled steel.

36 MATERIALS SCIENCE↗

Effects of Solidification Cooling Rates on Microstructures and Physical Properties of Fe-6.5%Si Alloys

Compared to the widely used Fe-3.2wt%Si steel, Fe-6.5wt%Si has superior electric and magnetic properties, including higher electrical resistivity, lower iron loss, higher permeability, and near zero magnetostriction. However, Fe-6.5wt%Si sheet is difficult to produce using traditional manufacturing processes as the high silicon content favors the formation of ordered phases that embrittle the material. Fortunately, these ordered phases can be suppressed if the alloy is cooled fast enough from a high temperature kinetically trapping the disordered solid solution or amorphous state. Planar flow casting is known for its rapid solidification rate. In order to consider it as a viable method to manufacture ductile Fe-6.5wt%Si sheets, the effect of cooling rate on physical properties of Fe-6.5wt%Si alloy are systematically investigated. In this work, various cooling rates are achieved by changing melt-spin wheel speeds, which significantly affect the solidification temperature profile and have profound effects on ordering, microstructures, textures, hardness, and magnetic properties. High cooling rates result in refined grains, reduced ordering, enhanced <100> out of the plane texture, decreased hardness, and increased coercivity. This study demonstrates a critical cooling rate at ~1.7 × 10 5 K/s, corresponding to a tangential wheel speed of 5-7 m/s, below which the hardness significantly increases in agreement with the sudden increase of the ordered phases that causes the material embrittlement.

36 MATERIALS SCIENCE↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Spatial distribution of internal heat gains: A probabilistic representation and evaluation of its influence on cooling equipment sizing in large office buildings

Internal heat gains from occupants, lighting, and plug loads are significant components of the space cooling load in an office building. Internal heat gains vary with time and space. The spatial diversity is significant, even for spaces with the same function in the same building. The stochastic nature of internal heat gains makes determining the peak cooling load to size air-conditioning systems a challenge. The traditional conservative practice of considering the largest internal heat gain among spaces and applying safety factors overestimates the space cooling load, which leads to oversized air-conditioning equipment and chiller plants. In this study, a field investigation of several large office buildings in China led to the development of a new probabilistic approach that represents the spatial diversity of the design internal heat gain of each tenant as a probability distribution function. In a large office building, a central chiller plant serves all air handling units (AHUs), with each AHU serving one or more floors of the building. Therefore, the spatial diversity should be considered differently when the peak cooling loads to size the AHUs and chillers are calculated. Finally, the proposed approach considers two different levels of internal heat gains to calculate the peak cooling loads and size the AHUs and chillers in order to avoid oversizing, improve the overall operating efficiency, and thus reduce energy use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Design, fabrication, and testing of a water-cooled tungsten-foam high-heat flux plasma-facing module

Here, we present a comprehensive study detailing the design, fabrication and testing a new modular “finger” component, featuring a hexagonal tungsten foam armor tile bonded to the top surface of the water-cooled finger unit. The mechanical, thermal, and particle transport properties of the tungsten foam armor were determined for a wide range of porosity and cell size, and then combined in an equivalent solid material with “effective” properties suitable for large-scale simulations. A series of 3-D multiphysics simulations for coupled thermal and mechanical behavior of the “finger” module are used to optimize the design before fabrication. The simulation results show that, for the expected experimental conditions, a safe range of heat flux and foam porosity is possible for both water-cooling and helium-cooling. Based on these multiphysics simulations, an optimum finger cooling module has been fabricated at Ultramet, Inc. A series of experiments were designed to study the thermomechanical performance of the “finger” unit under steady-state and transient thermal loading at surface heat flux up to 16 MW/m 2 in the High Energy Flux Test facility (HEFTY) at UCLA. Testing conditions included low-power, steady-state plasma exposure at 6 MW/m 2 , followed by severe high heat flux cycles at 16 MW/m 2 . Results of these tests are explained through comparisons with multiphysics simulations. To eliminate the effects of thermomechanical damage carried out on a module on its thermo-mechanical response on a subsequent test, three different yet identically designed and fabricated finger modules were tested. The results show that the current design is capable of cooling the walls of fusion devices at surface heat flux up to 6 MW/m 2 without failure, and that the failure heat flux limit is below 16 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation, cooling history and age of impact events on the IIE iron parent body: Evidence from the Miles meteorite

Most iron meteorites formed in planetary cores during differentiation, but the IIE iron meteorites have chemical and physical features that are inconsistent with this origin. By combining mineral chemistry, mineral modes and three-dimensional petrography, we reconstruct the bulk chemistry of the felsic silicate-bearing Miles IIE iron meteorite and demonstrate that the silicate inclusion compositions are similar to partial melts produced experimentally from an H chondrite composition. We use the reconstructed bulk composition, mineralogy and thermodynamic modelling to show that melting above ~ 1200°C under reducing conditions formed metal (Fe-Ni alloy) and felsic silicate partial melts. Upon cooling, the melts crystallized Mg-rich pyroxenes, Na- and K-rich feldspars, and tridymite. Importantly, this mechanism enriches cosmochemically volatile elements (i.e., those with a 50% condensation temperature of ~430–830°C, like Na and K) to the level found in the felsic silicate inclusions. The presence of crystallographically disordered srilankite (only stable above 1160°C) and an absence of Widmanstätten texture require both high peak temperatures and rapid cooling, which cannot be explained by core formation. Instead, they point to small melt volumes, a transient heat pulse, and small thermal mass, and imply efficient physical segregation of silicate and metallic melts through buoyancy separation followed by rapid cooling that arrested the separation of metal and silicate liquid phases. In situ 207 Pb/ 206 Pb age of 4542.3 ± 4.0 Ma in Zr-oxide and phosphate minerals dates the melting event that formed the silicate inclusions. This age aligns with the earliest ages found in other IIE iron meteorite silicates and requires a heating event ~25 million years after the solar system formed. We found 39 Ar/ 40 Ar ages of 3495 ± 52 Ma (low-T) and 4303 ± 7 Ma (high-T) in a K-feldspar grain, with the 3495 Ma age aligning with later thermal events recorded in other IIE iron meteorites. Dating reveals the complex petrogenetic and thermal history of Miles and the IIE iron meteorites. This is the first IIE iron meteorite found to record evidence of heating at 4.5 and 3.5 Ga likely from impact events. We propose that high-velocity impact(s) into an iron-rich, porous chondritic parent body at ~4.54 Ga produced immiscible metal and silicate melts that cooled rapidly and trapped low density silicate inclusions within high density metal. Other IIE irons that formed at lower peak temperatures (900–1000°C) contain chondritic silicate inclusions and relict chondrules, supporting this conceptual model. In conclusion, this petrogenesis is consistent with thermodynamic modelling, experimental data and the wide range of peak temperatures and cooling rates observed in the IIE iron meteorites.

58 GEOSCIENCES↗

Enhancing the thermosiphon-driven discharge of a latent heat thermal storage system used in a personal cooling device

Personal cooling devices reduce energy loads by allowing buildings to operate with elevated setpoint temperatures, without compromising on the occupant comfort. One such novel technology called the Roving Comforter (RoCo) uses a compact R134a based vapor compression system for cooling. Following its cooling operation, during which waste heat from the condensing refrigerant is stored in a phase change material (PCM), a two-phase loop thermosiphon is used to discharge (solidify) the PCM to enable its next operation. The transient operation of this thermosiphon is the focus of the present paper. Use of a PCM as the storage medium provides high energy density due to the ability to store thermal energy as latent heat during the phase transition; however, the discharge rate is limited by the low thermal conductivity of the PCM. Insertion of a graphite foam within the PCM can increase the rate of discharge and decrease the downtime of the cooling device. Since graphite enhancement involves a tradeoff between improving the discharge time at the expense of PCM volumetric latent heat, the impact of graphite foam density on the PCM discharge rate is investigated by using a Modelica-based transient model of the thermosiphon. The semi-empirical model, which uses relevant heat transfer coefficient and pressure drop correlations for both refrigerant and airside heat transfer, captures the complex phenomena involving simultaneous phase change of the refrigerant and the PCM. Finally, the graphite enhanced PCM selected from this analysis results in a 51% reduction in the discharge time with addition of only 5% to the thermal storage weight, without compromising the required cooling time.

42 ENGINEERING↗

The influence of cooling rate on condensation of iron, aluminum, and uranium oxide nanoparticles

Fundamental observations of particle size distributions are needed to develop models that predict the fate and transport of radioactive materials in the atmosphere following a nuclear incident. The extent of material transport is influenced by the time scales of particle formation processes (e.g., condensation, coagulation). In this study, we investigated the influence of cooling time scales on size distributions of uranium, aluminum, and iron oxide particles that are synthesized separately under identical run conditions inside the controlled environment of an argon plasma flow reactor. Two distinct temperature distributions are imposed along the flow reactor by varying the argon flow rate downstream of the plasma torch. The vaporized reactants of uranium, aluminum, and iron are cooled from about 5000K to 1000K before they are collected on silicon wafers for ex situ scanning electron microscope analysis. The microscope images show that the sizes of the largest aluminum and iron oxide particles heavily depend on the cooling time scales, whereas significant size variation with cooling rate is not observed for uranium oxide particles. In addition, the size distribution of aluminum oxide particles exhibits the broadest range among all three metal oxides studied. We performed simulations of particle size distributions using a kinetic model that couples gas phase oxidation chemistry with particle formation processes, including nucleation, condensation, and coagulation. The model results demonstrate the strong sensitivity of particle size distribution to different cooling histories (i.e., temperature vs residence time) along the flow reactor. In conclusion, the kinetic model also helps identify directions for future research to improve the predictions.

36 MATERIALS SCIENCE↗

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno↗

Engineered Nanoporous Frameworks for Adsorption Cooling Applications

The energy demand for traditional vapor-compressed technology for space cooling continues to soar year after year due to global warming and the increasing human population’s need to improve living and working conditions. Thus, there is a growing demand for eco-friendly technologies that use sustainable or waste energy resources. Here this review discusses the properties of various refrigerants used for adsorption cooling applications followed by a brief discussion on the thermodynamic cycle. Next, sorbents traditionally used for cooling are reviewed to emphasize the need for advanced capture materials with superior properties to improve refrigerant sorption. The remainder of the review focus on studies using engineered nanoporous frameworks (ENFs) with various refrigerants for adsorption cooling applications. The effects of the various factors that play a role in ENF–refrigerant pair selection, including pore structure/dimension/shape, morphology, open-metal sites, pore chemistry and possible presence of defects, are reviewed. Next, in-depth insights into the sorbent–refrigerant interaction, and pore filling mechanism gained through a combination of characterization techniques and computational modeling are discussed. Finally, we outline the challenges and opportunities related to using ENFs for adsorption cooling applications and provide our views on the future of this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Process-Specific Contributions to Anomalous Java Mixed Layer Cooling During Positive IOD Events

Negative sea surface temperature (SST) anomalies associated with positive Indian Ocean Dipole (pIOD) events first appear in the seasonal upwelling zone along the southern coast of Java during May–July. The evolution of anomalous SSTs in this coastal region is analyzed by computing a temperature budget using output from a strongly eddy-active ocean general circulation model. The seasonal cooling south of Java in May–July is driven by a reduction in incoming shortwave radiation and by vertical mixing, consistent with earlier studies in the region; however, the model budget also shows an advective contribution that drives anomalous cooling at the onset of pIOD events. To identify which process(es) are responsible for the anomalous advective cooling during pIOD events, a novel process index regression method is used to estimate the contributions of wind stress, equatorial Kelvin waves, mesoscale eddies, and Lombok Strait flow to anomalous cooling south of Java. Using this method, wind stress forcing along the west coast of Sumatra is found to make the most substantial contribution to anomalous cooling south of Java, with lesser contributions from equatorially sourced Kelvin waves and local wind stress. Mesoscale eddies redistribute heat from the Lombok Strait outflow, and have an anomalous warming effect on the eastern side of the upwelling region. The process-specific temperature budget south of Java highlights the importance of wind stress forcing west of Sumatra relative to equatorial and local forcing, and explains most of the mixed layer temperature anomaly evolution associated with advection during pIOD events.

54 ENVIRONMENTAL SCIENCES↗

Where Are White Roofs More Effective in Cooling the Surface?

Solar reflective roofs (also called white or cool roofs) are a common heat mitigation strategy. By reflecting more sunlight than regular roofs, cool roofs experience lower surface temperatures and produce less heating of the surrounding air. The effectiveness of cool roofs, quantified by the surface temperature difference between cool roofs and regular roofs ??????, is known to vary spatially. A common perception is that ?????? is controlled by solar radiation that reaches the roof surface. Here we use an Earth System Model and a surface energy balance model to show that the spatial variability of ??????, when normalized by the albedo difference between cool roofs and regular roofs (????), is in fact more controlled by an energy distribution factor that encodes the efficiencies of surface energy balance components in dissipating heat. Our results suggest that painting the roof white is more effective in reducing the roof surface temperature when the roof has less water holding capacity and smaller thermal admittance and is located in places with more solar radiation, less precipitation, and lower wind speed.

Wang, Linying↗

Shaping nanoscale magnetic domain memory in exchange-coupled ferromagnets by field cooling

The advance of magnetic nanotechnologies relies on detailed understanding of nanoscale magnetic mechanisms in materials. Magnetic domain memory (MDM), that is, the tendency for magnetic domains to repeat the same pattern during field cycling, is important for magnetic recording technologies. Here we demonstrate MDM in [Co/Pd]/IrMn films, using coherent X-ray scattering. Under illumination, the magnetic domains in [Co/Pd] produce a speckle pattern, a unique fingerprint of their nanoscale configuration. We measure MDM by cross-correlating speckle patterns throughout magnetization processes. When cooled below its blocking temperature, the film exhibits up to 100% MDM, induced by exchange-coupling with the underlying IrMn layer. The degree of MDM drastically depends on cooling conditions. If the film is cooled under moderate fields, MDM is high throughout the entire magnetization loop. Lastly, if the film is cooled under nearly saturating field, MDM vanishes, except at nucleation and saturation. Our findings show how to fully control the occurrence of MDM by field cooling.

36 MATERIALS SCIENCE↗