Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative scheme”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

972 records · Page 54

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Energizer Bunny: Dual-Use Photovoltaic and Pasture-Raised Rabbit Farms (Final Report)

This case study project lays the groundwork for the broader realization of agrivoltaics by considering the techno-economic, environmental, and social aspects of system development and assessing a novel rabbit-based concept. Research on the social and political barriers to agrivoltaic development is sparse, which emphasizes the importance of this project as it provides key insight into the consequential socio-political challenges that may hinder the diffusion of agrivoltaic technology. Additionally, the rabbit agrivoltaic concept is novel and has not been applied in experimental or commercial applications to date. This project advances our understanding of the viability of this co-location scheme through empirical assessment of integrating grazing rabbits with solar. A total of five manuscripts (3 published in peer-reviewed journals, 2 under review) have resulted from this project. The techno-economic component of the project included a) a pilot test study investigating the feasibility of the rabbit agrivoltaic concept and b) an economic analysis of the advantages available to solar operators who leverage grazing animals for lawn maintenance and a dual-revenue stream. Our calculations indicate that the co-location of solar and rabbit farms is a viable form of agrivoltaics, increasing overall site revenue by 2.5%-24.0% above projected electricity revenue. The environmental component of the project entailed an ISO 14040 and 14044 compliant life cycle assessment to quantify the impacts of the rabbit agrivoltaic concept. The results indicate pasture-based agrivoltaic systems provide a dual synergy that produces 69.3% less emissions and demands 82.9% less fossil energy per functional unit of cumulative MWh output of electricity and cumulative kg of meat compared to non-integrated production. The social component of the project included conducting two separate interview studies with agriculture and solar industry professionals and the distribution of a public survey. The interview findings identify the key socio-political opportunities for agrivoltaics include: the retention of agricultural land and rural interests, and increased local level acceptance of solar development. The key barriers to agrivoltaics include: ensuring long term agricultural productivity is not compromised, and subnational zoning strategies. The survey results indicate that support for local solar projects increase by 10% when an agricultural function is incorporated. Survey respondents prefer agrivoltaic projects that are a) designed to provide economic opportunities for farmers and the local community b) located on private property or existing agricultural land, and c) do not threaten local interests. Cumulatively, this project can inform agrivoltaic decision making, solar development practices, rabbit-based applications, land use management, and policy making in a way that supports the furtherance of the renewable energy transition, conserves arable land, and utilizes innovative solar photovoltaic technologies.

14 SOLAR ENERGY↗

Economic analysis of CCUS: Accelerated development for CO 2 EOR and storage in residual oil zones under the context of 45Q tax credit

Residual oil zones (ROZ) undergoing CO 2 Enhanced Oil Recovery (CO 2 -EOR) may benefit from specific strategies to maximize their value. We evaluated several strategies for producing from a Permian Basin, West Texas, USA field’s ROZ. This ROZ lies below the main pay zone (MPZ) of the field. Such brownfield ROZs occur in the Permian Basin and elsewhere. Since brownfield ROZs are hydraulically connected to the MPZs, development sequences and schemes influence oil production, CO 2 storage, and net present value (NPV). We conducted economic assessments of various CO 2 injection/production schemes in the stacked ROZ-MPZ reservoir based on flow simulations of a high-resolution geocellular model built from wireline logs and core data and calibrated through production history matching. Flow simulations of water alternating gas (WAG) injection, such as switching injection from the MPZ to the ROZ and commingled production, were studied. Simulation results showed that simultaneous CO 2 injection into the MPZ and ROZ lead to the largest oil production and, generally, the largest NPV. If instead, CO 2 was simultaneously injected into the MPZ and ROZ, then into the ROZ alone, this maximized CO 2 storage. CO 2 storage can be used as a tax credit under the Internal Revenue Code, Section 45Q. Storage performance depends on the development approach and WAG ratio. Developing the ROZ increased storage compared to only producing from the MPZ. The WAG ratio to maximize oil production did not always yield the largest NPV. These findings are potentially applied to other Brownfield ROZs, which are common below San Andres reservoirs in the Permian Basin and other basins. ROZ development can increase oilfields’ NPV and carbon storage potential. Our study can serve as an analog for similar reservoirs. Here this work provides valuable insights into the further optimization of brownfield ROZ development and information for operators to plan to develop stacked ROZ-MPZ reservoirs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon-Assisted, Continuous Syngas Production in a Chemical Looping Scheme

In the current energy and environment scenario, it is imperative to develop energy efficient routes for chemical manufacturing that also pave the way for mitigation of greenhouse gas emissions. This work presents an efficient pathway for continuous syngas production via a chemical looping conversion of the two most potent greenhouse gases—CH 4 , and CO 2 . The well-known dry-reforming process of converting CH 4 , and CO 2 to syngas is energy-intensive and suffers from catalyst deactivation. The chemical looping approach, on the other hand, provides avenues for mitigating catalyst deactivation and enabling improved energy efficiency. The key to such process enhancements lies in the intricate structure–function relationships of the catalyst and its correlation to the process variables. We present the reduction and oxidation characteristics of 5 wt.% Ni/Ce 1-x Zr x O 2 -based catalysts (x = 0, 0.4, and 0.625). We demonstrate low temperature CH4 activation over Ni-promoted samples as opposed to pure Ce 1-x Zr x O 2 . Moreover, our results depict an optimum regeneration of these catalysts when oxidized by CO 2 , and H 2 O, which allows for chemical looping operation of steam reforming of methane as well. Process variables were tuned to optimize the CH 4 conversion (over 80%), and H 2 /CO ratio at 650 °C. The critical surface reactions—carbon accumulation and gasification, and thermocatalytic CO 2 splitting were investigated to elucidate the dynamic nature of the catalyst surface. In conclusion, the impact of this work lies in showcasing the opportunities to design chemical looping reactors for energy efficient syngas production from waste greenhouse gases.

25 ENERGY STORAGE↗

Benchmarking thermal energy storage cost for industrial process heat

Process heat accounts for roughly half of industrial energy demand, and currently 95% of process heat is derived from the combustion of natural gas, oil, and coal. Electrification of industrial heating could be an alternative, potentially expanding locations suitable for manufacturing; however, industrial facility owners may desire energy storage to stabilize energy costs. In this work, the economic benefits of pairing thermal storage with electrified process heat to reduce the average price paid for energy are analyzed. Cost savings focus on energy arbitrage, or leveraging flexible energy pricing schemes, alone. The cost of natural gas combustion across decades (2019-2060) is compared to the costs of electricity and thermal energy storage in four United States Independent System Operator (ISO) regions. Systems installed today may not yield positive net present value (NPV) compared to the use of natural gas. However, using estimated electricity prices, systems installed in 2030 using arbitrage alone could be profitable when compared to natural gas in some regions of the U.S. Furthermore, if capital expenditures could be reduced by 50% for sensible thermal storage systems by 2030, profitable systems are found across all regions. This implies that electrification of industrial process heat, when paired with inexpensive thermal energy storage systems, could be less expensive than brownfield natural gas systems, using arbitrage as the only source of revenue and without a dependency on any future policy drivers such as pricing externalities that could further incentivize the electrification of industrial process heat.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acceleration Modes and Transitions in Pulsed Plasma Accelerators

Pulsed plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas, ionizing and accelerating it through the Lorentz body force. Two plasma accelerator types employing this general scheme have typically been studied: the gas-fed pulsed plasma thruster and the quasi-steady magnetoplasmadynamic (MPD) accelerator. The gas-fed pulsed plasma accelerator is generally represented as a completely transient device discharging in approximately 1-10 microseconds. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j (current density) by B (magnetic field) body force, entraining propellant it encounters. This process is sometimes referred to as detonation-mode acceleration because the current sheet representation approximates that of a strong shock propagating through the gas. Acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new current sheet at the breech and depriving the initial sheet of additional acceleration. In the quasi-steady MPD accelerator, the pulse is lengthened to approximately 1 millisecond or longer and maintained at an approximately constant level during discharge. The time over which the transient phenomena experienced during startup typically occur is short relative to the overall discharge time, which is now long enough for the plasma to assume a relatively steady-state configuration. The ionized gas flows through a stationary current channel in a manner that is sometimes referred to as the deflagration-mode of operation. The plasma experiences electromagnetic acceleration as it flows through the current channel towards the exit of the device. A device that had a short pulse length but appeared to operate in a plasma acceleration regime different from the gas-fed pulsed plasma accelerators was developed by Cheng, et al. The Coaxial High ENerGy (CHENG) thruster operated on the 10-microseconds timescales of pulsed plasma thrusters, but claimed high thrust density, high efficiency and low electrode erosion rates, which are more consistent with the deflagration mode of acceleration. Separate work on gas-fed pulsed plasma thrusters (PPTs) by Ziemer, et al. identified two separate regimes of performance. The regime at higher mass bits (termed Mode I in that work) possessed relatively constant thrust efficiency (ratio of jet kinetic energy to input electrical energy) as a function of mass bit. In the second regime at very low mass bits (termed Mode II), the efficiency increased with decreasing mass bit. Work by Poehlmann et al. and by Sitaraman and Raja sought to understand the performance of the CHENG thruster and the Mode I / Mode II performance in PPTs by modeling the acceleration using the Hugoniot Relation, with the detonation and deflagration modes representing two distinct sets of solutions to the relevant conservation laws. These works studied the proposal that, depending upon the values of the various controllable parameters, the accelerator would operate in either the detonation or deflagration mode. In the present work, we propose a variation on the explanation for the differences in performance between the various pulsed plasma accelerators. Instead of treating the accelerator as if it were only operating in one mode or the other during a pulse, we model the initial stage of the discharge in all cases as an accelerating current sheet (detonation mode). If the current sheet reaches the exit of the accelerator before the discharge is completed, the acceleration mode transitions to the deflagration mode type found in the quasi-steady MPD thrusters. This modeling method is used to demonstrate that standard gas-fed pulsed plasma accelerators, the CHENG thruster, and the quasi-steady MPD accelerator are variations of the same device, with the overall acceleration of the plasma depending upon the behavior of the plasma discharge during initial transient phase and the relative lengths of the detonation and deflagration modes of operation.

Polzin, Kurt A.↗

Heterogeneous Integration Technologies for High-temperature, High-density, Low-profile Power Modules of Wide Bandgap Devices in Electric Drive Applications (Final Technical Report)

The goal of this project is to develop packaging technologies for making high-temperature, high-density, and low-profile wide-bandgap (WBG) power electronics modules for electric drives. These modules are aimed at enabling the DOE’s University Consortium to reach its 2025 inverter targets of ≥ 100 kW/L and ≤ 2.7 $/kW. The specific objectives are to: design and fabricate SiC half-bridge power modules with double-sided cooling and parasitic inductances < 5 nH, heat flux density > 400 W/cm 2 , and working junction temperature of 200 o C; design, fabricate, and deliver a gate driver with double-sided cooled modules for the construction of a 100 kW/L inverter at Oak Ridge National Lab; and design and prototype intelligent gate drivers with integrated current sensor and a low-profile DC-DC power supply with air-core transformer for testing power modules at 200 o C junction temperature. We followed an iterative technical approach of design, simulation, fabrication, and testing of various versions of modules, current sensors, and power supply. The state-of-the-art silicon carbide devices rated at 1.2 kV and 149 A were packaged by sintered-silver bonding on an aluminum nitride direct-bond-copper substrate for high thermal conductivity, high working temperature, and high joint reliability. Porous silver posts were used to interconnect the device’s source pads to the other direct-bond-copper substrate for low mechanical stresses, ease of manufacturing, and double-sided cooling. A current sensor based on package parasitic inductance was developed to measure switching current. A dynamic feedback scheme was developed to compensate the effect of parasitic resistance and temperature variation. A constant-current class-E dc-dc converter with air-core transformer was developed. Air-core transformer was used due to the unavailability of magnetic core at high temperatures. Gate driver and power supply were integrated with the double-side cooled, high temperature SiC power modules for testing the modules at 200 o C junction temperature. Double-pulse and continuous testing of the integrated technologies validated the design and fabrication of the three component technologies. Throughout the project, we overcame the challenge for design verification caused by low prototyping yield, which then helped train the graduate students, the future workforce, to learn the engineering know-how for low-cost manufacturing of reliable products. Below is a summary of the major accomplishments of this project: development of a prototyping process for fabricating double-side cooled (1200 V, 149 A) SiC phase-leg modules capable of working to 200 o C Tj; simulation and experimental verification of the improvement of thermo-mechanical reliability of the double-side cooled SiC phase-leg module by using rigid encapsulant; design and experimental validation of a current sensor based on package parasitic inductance and a compensation solution for eliminating the effect of parasitic resistance; design and experimental validation of a low-profile power supply with six-output air-core transformer for gate driver; functional demonstration of a SiC phase-leg module integrated with its gate driver, current sensor, and an air-core power supply at 200 o C Tj in a double-pulse switching test setup and Buck converter continuous test setup; successful completion of six PhD and two MS students who are or will work at Apple Inc., Tesla Inc., Wolfspeed Inc., Microchip Inc., Monolithic Power Systems Inc., and LG Magna Inc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling of the Electricity and Transportation Sectors - Part I: Sector Overviews

“Sector coupling” is a concept that addresses potential designs for the future power industry. Traditionally, the energy sectors, i.e., electricity supply, transport, and industry, have functioned largely independently from one another. Thus, the concept of sector coupling means that the electricity sector would become the central pillar of the energy system, supplying the other sectors – transportation and industry – with energy in various ways, a scheme described by the term “Power-to-X”. This report delves into the ambitious goal set by the United States to achieve net-zero emissions by 2050, with a pivotal milestone of making half of all passenger vehicles sold in America zero-emission by 2030. Central to achieving this objective is the electrification of the transportation sector, resulting in complex interactions between this sector and the electric industry. As electric vehicles become more prevalent, a shift in the dependency on electricity for vehicle charging emerges, alongside a reduction in the electricity demand associated with maintaining the fossil fuel supply chain. Both the electricity and fossil fuel have been identified as critical infrastructure sectors, the transportation sector's historical reliance on fossil fuels, and the mature supply chain supporting them are explored. This study emphasizes the existing sectoral coupling between the electric energy and transportation sectors, extending beyond vehicle charging to essential operations at refineries, pipeline facilities, storage, and fuel extraction. Recognizing the critical dependency of fossil fuel supply chain operations on the electric sector, this research underscores the need for a comprehensive view of the evolving dynamics between the transportation and electric sectors. This study has been split into two segments, Part-I provides an overview of the existing fossil fuel supply chain architecture and the electrical sector. We provide an in-depth analysis of the grid-transportation sectoral coupling, its interactions, the vulnerabilities and essential take-aways that would help us to address them and apply towards an electrified transportation sector in the future. We engaged with stakeholders to understand their expectations in enabling an electrified transportation. We accumulate the understandings from the current fossil fuel-based system in developing a risk matrix, by identifying all the threats and vulnerabilities and how would they apply to both the current and future transportation systems in Part-II of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detonation to Deflagration-Mode Transitions in Pulsed Plasma Accelerators

PULSED plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas. The current in such discharges will ionize the gas and produce a strong magnetic field, which interacts with the flowing current to accelerate the plasma through the Lorentz body force. For the present work, two plasma accelerator types employing this general scheme are of interest: the gas-fed pulsed plasma thruster (PPT) 1 and the quasi-steady magnetoplasmadynamic (MPD) accelerator. 2 The gas-fed pulsed plasma accelerator is generally understood as a completely transient device discharging in ∼1-10 μs. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j × B body force, entraining and accelerating propellant it encounters. This process is sometimes referred to in literature as 'snowplowing' the propellant or accelerating the gas in a detonation-mode because the current sheet representation approximates that of a strong detonation shockwave propagating through the gas. For these devices, acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new 'crowbar' discharge at the breech and depriving the initial sheet of additional acceleration. In general, PPTs typically claim thrust efficiencies (ratio of jet kinetic energy to input electrical energy) registering in the teens or lower. 3 In the quasi-steady MPD accelerator, the pulse is lengthened to ∼1 ms or longer and maintained at an approximately constant level during discharge through the use of a pulse-forming network (PFN) of capacitors. After an initial transient discharge, which is typically short relative to the overall discharge period, the plasma assumes a relatively steady-state configuration, known as 'quasi-steady' MPD operation. 2 In this state, ionized gas flows through a stationary current channel in a manner that is sometimes referred to as deflagration-mode operation owing to the similarities to deflagration waves in gases. The plasma experiences electromagnetic acceleration as the plasma flows through the current channel towards the exit of the device. Quasi-steady MPD thrusters claim efficiencies up to 50% for certain propellants.4 There has been significant and sustained research over several decades on both gas-fed PPTs and quasi-steady MPD thrusters, however there have been pulsed thrusters that do not appear to exactly fit either classification, instead possessing a mixture of operational qualities characteristic of both thruster variants. The Coaxial High ENerGy (CHENG) thruster by Cheng, et al.5 operated on the short 10 μs timescales characteristic of PPTs, but claimed the high thrust densities, high efficiencies, and low electrode erosion rates that are more consistent with the MPD/deflagration mode of plasma acceleration. Gas-fed PPT research by Ziemer, et al. 3, 6 identified two separate regimes of performance in those thrusters. The regime at higher mass bits (termed Mode I in that work) possessed relatively constant thrust efficiency as a function of mass bit, while the second regime at very low mass bits (termed Mode II) exhibited an increase in efficiency with decreasing mass bit. Work by Poehlmann et al.7 and by Sitaraman and Raja8 sought to understand the performance of the CHENG thruster and the Mode I/Mode II performance in PPTs by modeling the acceleration using the Hugoniot Relation, with the detonation and deflagration modes of plasma acceleration representing two distinct sets of solutions to the relevant conservation laws. In these works, it was proposed that the values of the various controllable parameters determined whether the accelerator would operate in detonation or deflagration mode. Our hypothesized view of the acceleration process in the CHENG thruster and in PPTs experiencing a transition from Mode I to Mode II is inspired by observations of the transition from the PPT mode of operation to the quasi-steady MPD mode. Specifically, the quasi-steady MPD was discovered by driving a PPT to extended pulse lengths. Above a certain pulse length threshold the transient plasma current sheet transitions into a stable plasma acceleration mode that 'replicates in every observable detail steady flow self-field magnetoplasmadynamic acceleration.' 9 In the present work, instead of treating the accelerator as if it were only operating in a single mode during a pulse, we consider the initial stage of the discharge in all cases as a current sheet forming at the breach of the accelerator and moving towards the exit as a detonation wave. If the current sheet reaches the exit of the accelerator before the discharge is completed, the view of the acceleration mode transitions to the deflagration mode-type found in quasi-steady MPD thrusters. In previous work10 we presented a modeling framework that first captured the time-evolution of the current sheet (detonation) mode of the thruster and then transitioned into the quasi-steady MPD (deflagration) mode of plasma acceleration. In the present work, variations of the controllable parameters - specifically the pulsed circuit properties, the amount of mass injected into the thruster, and the relative timing between the initial gas injection and the initiation of the plasma current sheet - will be used to explore the thruster performance. A range of parameters are explored to demonstrate that standard gas-fed pulsed plasma accelerators, the CHENG thruster, and the quasi-steady MPD accelerator are variations of the same device, with the overall acceleration of the plasma depending upon the behavior of the plasma discharge during initial transient phase and the relative lengths of the detonation and deflagration modes of operation.

Polzin, Kurt A.↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large Solar-Rejection Filter

NASA utilized Image Intensified Video Cameras for ATV data acquisition from a jet flying at 12.8 km. Afterwards the video was digitized and then analyzed with a modified commercial software package, Image Systems Trackeye. Astrometric results were limited by saturation, plate scale, and imposed linear plate solution based on field reference stars. Time-dependent fragment angular trajectories, velocities, accelerations, and luminosities were derived in each video segment. It was evident that individual fragments behave differently. Photometric accuracy was insufficient to confidently assess correlations between luminosity and fragment spatial behavior (velocity, deceleration). Use of high resolution digital video cameras in future should remedy this shortcoming. A scenically accurate description of matter interpreted as a substance made up of corpuscular constituents was established during the course of the 19th century. In this description, atoms--the building blocks of the matter--form molecules. The properties of the molecules were described by chemistry or thermodynamics depending on what characteristics of the matter were investigated. In both theories, the molecules can dissociate to atoms when the kinetic energies of the atoms exceed the strength of the chemical bonds. The number of atoms is always preserved in a closed system. This is not true, however, when the matter takes up much higher energies at relativistic scales. New particles can be produced at the expense of the kinetic energy. The number of particles is no longer preserved. There are other conserved quantities, however, these quantities, the charge, baryon number, lepton number, are associated with particles that are considered elementary today. The properties and behavior of these elementary particles is the subject of Particle Physics or High Energy Physics. Practice Page: A crewmember touching a positively charged surface was thought to be galvanically isolated from the vehicle ground analogous to a bird on a high voltage power wire. Recent analysis confirms that positive floating potentials, ionospheric currents to the EVA suit, can be hazardous. The analysis is wrong in that the ionospheric plasma itself can close the circuit. Parametric analysis of very low voltage exposures (2 to 15 volts) could cause pain and/or involuntary muscle tetani or spinal cord shock. NASA worked with the Naval Health Research Center Detachment Directed Energy Bioeffects Laboratory to examine the affects electrical hazards could have on extravehicular activity using two models. The results of the two computational models were combined to predict areas of the body in which neurons of different diameters would be excited. They predicted that physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work to analyze additional current paths was proposed. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is 3 times solar, and sulfur is 20 times solar. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is times solar, and sulfur is 20 times solar. From its previously observed optical emission lines, P831-57 (WD 0334 6400 or Ret 1 in A Catalog and Atlas of Cataclysmic Variables: Living Edition) has been suspected to contain an accretion disk associated with a companion star in orbit around a subdwarf star with a temperature T is greater than 21,000K. P831-57 has therefore been classified as a nova-like. However, our present observations show it to be a DA + dMe binary. The analysis of its Far Ultraviolet Spectroscopic Explorer (FUSE) spectrum (continuum and lines) reveal an average mass white dwarf (Log(g) approximately equals 7.8 plus or minus 0.1)with a temperature T approximately equals 37,000 plus or minus 500K, an extremely low projected rotational velocity, and a distance of about 115 plus or minus 5pc. The photosphere contains C, N, Si, and S (at about 1% of solar abundances). The dMe star is seen as a flux excess in near-infrared photometry and appears to show occasional flaring of about one magnitude as seen in the Harvard plates. There is no evidence of periodic variability in the spectroscopic or photometric data. We find no evidence of a an accretion disk, instead we find evidence of wind accretion as the stellar carbon abundance (N(C)/N(H) = 2.5 x 10 (exp -6) is about ten times larger than predicted by radiative levitation for such a gravity and temperature. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. The symptoms and threats from acute mountain sickness (AMS) are discussed. The underlying assumptions concerning spacecraft atmosphere mean there is a potential risk to astronauts. The baseline worst case scenario is about 25% based on direct ascent to 8.0 psia with 32% O2. The practical mitigation approach is a staged depressurization scheme. Due to the uncertainty about potential AMS risk the flight surgeon should prepare, focused research should proceed, and current analytical efforts should continue. This slide presentation reviews the threat astronauts face from acute mountain sickness (AMS). The incidence of AMS is highly variable and the risk to astronauts is unclear. However, the potential risk is higher than current EAAs suggest and precautions should be implemented. Due to the uncertain nature of the risk flight surgeons should prepare, and focused research should proceed. Quasiparticle tunneling can be understood at low temperatures using a non-equilibrium kinetic theory. Low-temperature tunneling can be suppressed using existing techniques: island-lead gap engineering, lead cooling with SIN junctions, and quasiparticle traps. The slide presentation reviews the science goals and mission planning for the proposed Jupiter System Observer (JSO). The spacecraft would accommodate 9 instruments making the instrument payload more capable than any previously flown to Jupiter. The would-be mission includes study programs for Jupiter's satellites, interior, magnetosphere and atmosphere. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. This slide presentation reviews the power requirements for the space exploration and the lunar surface mobility programs. It includes information about the specifications for high energy batteries and the power requirements for lunar rovers,

Roberts, William↗

Launch Complex 34, SWMU CC054 2023 DNAPL Source Zone Operations, Maintenance, and Monitoring, Site-Wide Long-Term Monitoring, and Hot Spot 6 Air Sparge System Annual Performance Monitoring and Phase Two Expansion Construction Completion Report Cape Canaveral Space Force Station, Florida

This Annual Performance Monitoring Report (PMR) for the Dense Non-Aqueous Phase Liquid (DNAPL) Source Zone (DSZ), Site-Wide Long-Term Monitoring (LTM), and Hot Spot 6 (HS 6) Air Sparge (AS) System presents the results of Year 14 operations and performance monitoring of the hydraulic containment (HC) Interim Measure (IM), details associated with construction and implementation of the HS 6 AS system expansion (Phase Two), and the results of operations and performance sampling of the HS 6 AS IM at Launch Complex 34 (LC34), located at Cape Canaveral Space Force Station (CCSFS), Florida. The timeframe for activities documented in this PMR extends from April 1, 2023 to March 31, 2024. LC34 has been designated Solid Waste Management Unit CC054 under the Kennedy Space Center (KSC) Resource Conservation and Recovery Act Corrective Action Program. The objective of the HC IM at LC34 is to contain the shallow and deep DSZ and surrounding dissolved-phase trichloroethene (TCE) high concentration plume via operation of a hydraulic containment system (HCS). The pre-IM design 300 micrograms per liter (μg/L) TCE groundwater contour was used to establish the deep zone capture area for deep recovery wells, and the shallow zone capture area was defined by the DSZ. The system began operating in 2010, and in 2015, the system was expanded to provide HC for areas within the 300 μg/L TCE groundwater isocontours of HS 3 and 4. In 2018 and 2019, an investigation was conducted to recharacterize the DSZ, which included investigating TCE mass in Layer 7. This data was subsequently used to optimize the pumping rates of the HCS and install additional recovery wells in Layer 7 to more adequately capture residual contaminant mass. The operational period for Year 14 of the HCS was from April 1, 2023 to March 31, 2024. Operational runtime for the system was 94 percent during Year 14, with downtime events attributed to planned maintenance, system repairs, and power outages. As of March 31, 2024, a total of 344,849,634 cumulative gallons of groundwater containing 94,656 pounds of chlorinated volatile organic compounds (CVOCs) have been removed by the HCS. During the reporting period covered under this report, the HCS recovered 31,176,393 gallons and approximately 6,319 pounds of CVOC mass. Total combined influent concentrations of TCE have decreased since startup from approximately 280,000 µg/L (January 2010) to 25,000 µg/L (March 2024). During the reporting period, all effluent concentrations from the HCS (aqueous and vapor) were below regulatory reporting limits, indicating the system continues to operate as intended. Performance monitoring was conducted in January 2024 within the DSZ to evaluate TCE contamination. Groundwater samples were collected via DPT at nine locations, consistent with previous events between 2017 and 2022. Full vertical profile sampling was completed at each DPT from 8 to 98 feet below land surface (bls), at 5-foot intervals. The DPT performance monitoring results are summarized in this PMR. The results revealed TCE remains at concentrations greater than 11,000 µg/L in the DSZ (1-percent solubility, indicative of DNAPL) at eight of the nine DPT locations and at depths ranging from 28 to 98 feet bls. An overall decreasing trend of TCE concentrations was observed in DPT samples during this reporting period, which is a reduction from the previous event (December 2022) and the peak event in December 2021, where TCE percentages appeared to increase in all depth zones because several recovery wells were turned off during the AS pilot study in the DSZ. The maximum TCE concentration in January 2024 was 1,600,000 µg/L in the 53 feet bls depth interval at DPT594 (previous maximum result in 2022 was 1,800,000 µg/L in the 48 feet bls depth interval at DPT599). This maximum concentration in the 53 feet bls depth interval is in the deep capture zone. During the January 2024 DPT event, the largest portion of TCE mass was observed in the 48 feet bls interval above/within Layer 4. This trend remains consistent with previous years and appears to indicate continued mass discharge from Layer 4 (fine-grained unit). In addition to DPT sampling, annual groundwater samples were collected from 11 deep monitoring wells in the DSZ area (Layers 7 and 8) in December 2023 to verify vertical and horizontal delineation. Three of the wells were also sampled biweekly to evaluate operations of recovery well RW21D (screened 86 to 106 feet bls), which was installed in January 2023. Of the Layer 7/8 monitoring sampled only annually, results were non-detect or less than groundwater cleanup target levels GCTLs in December 2023, with the exception of one well, IW45D2, which had a cis-1,2-dichloroethene (cDCE), detection greater than the GCTL. Of the three wells sampled biweekly during the operational period, the well located closest to Layer 7 recovery well RW21D (IW44D2, screened 105 to 115 feet bls) had concentrations of TCE, cDCE and vinyl chloride (VC) greater than GCTLs throughout the operational period, but displayed a decreasing trend since the peak concentrations in September 2023. The maximum TCE concentration during this operational period was 190,000 µg/L at IW44D2 in September 2023, but reduced to 700 µg/L in March 2024, indicating the HCS is still effectively removing mass from the source area. Expansion of the HCS and addition of new recovery wells is ongoing and will continue to be evaluated as the groundwater recovery scheme is optimized. Details of the expansion and optimization will be provided in a future PMR. The HS 6 AS IM was initiated in 2018 with 160 AS wells and expanded in 2019 with another 140 AS wells. An additional expansion of the HS 6 AS IM was completed during the reporting period covered under this report and details of the construction implementation and startup of the expansion are detailed in Section III of this report. The new expansion, referred to as Phase Two, was implemented between August 17, 2022 and August 28, 2023, and included the installation of 190 air sparge wells to treat an additional 11.2 acres. The original configuration (referred to as Phase One) operated until Phase Two came online, then all but 52 AS wells were turned off so the components could be moved and utilized in the Phase Two area. The 52 AS wells that remain on are in a barrier configuration preventing contaminated groundwater from impacting the treated area. The HS 6 AS system (both Phase One and Two) operated normally during the reporting period covered under this report. Semi-annual performance monitoring of the Phase One configuration was conducted in April and November 2023, consistent with previous years. For the Phase Two configuration, 21 new monitoring wells were installed and sampled quarterly, with a baseline event in July 2023, and quarterly events in November 2023 and February 2024 summarized in this report. Semi-annual monitoring results collected in April and October 2023 show concentrations of contaminants of concern (cDCE, trans-1,2-dichloroethene, and VC) have decreased to less than GCTLs in nearly all wells and not impacting the surface water drainage canal, indicating the HS 6 IM continues to meet objectives. The baseline and quarterly sampling for the Phase Two configuration indicate generally decreasing concentrations in wells within and around the perimeter of the treatment area. At least two more quarters of monitoring will be conducted and once those results are evaluated a reduced the sampling frequency may be considered. Overall, the tasks associated with Year 14 operation of the HC IM and operation of the HS 6 AS IM were performed in accordance with recommendations included in the previous 2022 LC34 (Year 13) PMR. Evaluation of results from the HC IM and HS 6 IM show that these systems are operating as designed and meeting performance objectives.

groundwater remediation↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗