Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

SU-F-T-398: Improving Radiotherapy Treatment Planning Using Dual Energy Computed Tomography Based Tissue Characterization

Purpose: Both kVp settings and geometric distribution of various materials lead to significant change of the HU values, showing the largest discrepancy for high-Z materials and for the lowest CT scanning kVp setting. On the other hand, the dose distributions around low-energy brachytherapy sources are highly dependent on the architecture and composition of tissue heterogeneities in and around the implant. Both measurements and Monte Carlo calculations show that improper tissue characterization may lead to calculated dose errors of 90% for low energy and around 10% for higher energy photons. We investigated the ability of dual-energy CT (DECT) to characterize more accurately tissue equivalent materials. Methods: We used the RMI-467 heterogeneity phantom scanned in DECT mode with 3 different set-ups: first, we placed high electron density (ED) plugs within the outer ring of the phantom; then we arranged high ED plugs within the inner ring; and finally ED plugs were randomly distributed. All three setups were scanned with the same DECT technique using a single-source DECT scanner with fast kVp switching (Discovery CT750HD; GE Healthcare). Images were transferred to a GE Advantage workstation for DECT analysis. Spectral Hounsfield unit curves (SHUACs) were then generated from 50 to 140-keV, in 10-keV increments, for each plug. Results: The dynamic range of Hounsfield units shrinks with increased photon energy as the attenuation coefficients decrease. Our results show that the spread of HUs for the three different geometrical setups is the smallest at 80 keV. Furthermore, among all the energies and all materials presented, the largest difference appears at high Z tissue equivalent plugs. Conclusion: Our results suggest that dose calculations at both megavoltage and low photon energies could benefit in the vicinity of bony structures if the 80 keV reconstructed monochromatic CT image is used with the DECT protocol utilized in this work.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-07: Determination of Patient-Specific Myocardial Mass at Risk Using Computed Tomography Angiography

Purpose: To evaluate the accuracy of a patient-specific coronary perfusion territory assignment algorithm that uses CT angiography (CTA) and a minimum-cost-path approach to assign coronary perfusion territories on a voxel-by-voxel basis for determination of myocardial mass at risk. Methods: Intravenous (IV) contrast (370 mg/mL iodine, 25 mL, 7 mL/s) was injected centrally into five swine (35–45 kg) and CTA was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Additionally, a 4F catheter was advanced into the left anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA) and contrast (30 mg/mL iodine, 10 mL, 1.5 mL/s) was directly injected into each coronary artery for isolation of reference coronary perfusion territories. Semiautomatic myocardial segmentation of the CTA data was then performed and the centerlines of the LAD, LCX, and RCA were digitally extracted through image processing. Individual coronary perfusion territories were then assigned using a minimum-cost-path approach, and were quantitatively compared to the reference coronary perfusion territories. Results: The results of the coronary perfusion territory assignment algorithm were in good agreement with the reference coronary perfusion territories. The average volumetric assignment error from mitral orifice to apex was 5.5 ± 1.1%, corresponding to 2.1 ± 0.7 grams of myocardial mass misassigned for each coronary perfusion territory. Conclusion: The results indicate that accurate coronary perfusion territory assignment is possible on a voxel-by-voxel basis using CTA data and an assignment algorithm based on a minimum-cost-path approach. Thus, the technique can potentially be used to accurately determine patient-specific myocardial mass at risk distal to a coronary stenosis, improving coronary lesion assessment and treatment. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

The Nature of Electrochemical Delithiation of Li-Mg Alloy Electrodes: Neutron Computed Tomography and Modeling of Li Diffusion and Delithiation Phenomenon

Li-Mg alloys are promising as positive electrodes (anodes) for Li-ion batteries due to the high Li storage capacity and the relatively lower volume change during the lithiation/delithiation process. They also present a unique opportunity to image the Li distribution through the electrode thickness at various delithiation states. In this work, spatial distributions of Li in electrochemically delithiated Li-Mg alloy electrodes have been quantitatively determined using neutron tomography. Specifically, the Li concentration profiles along thickness direction are determined. A rigorous analytical model to quantify the diffusion-controlled delithiation, accompanied by phase transition and boundary movement, has also been developed to explain the delithiation mechanism. The analytical modeling scheme successfully predicted the Li concentration profiles which agreed well with the experimental data. It is demonstrated that during discharge Li is removed by diffusion through the solid solution Li-Mg phases and this proceeds with β→α phase transition and the associated phase boundary movement through the thickness of the electrode. This is also accompanied by electrode thinning due to the change in molar volume during delithiation. In conclusion, following the approaches developed here, one can develop a rigorous and quantitative understanding of electrochemical delithiation in electrodes of electrochemical cells, similar to that in the present Li-Mg electrodes.

25 ENERGY STORAGE↗

Livermore Computed Tomography Input/Output library

Read, write, and connect visualizers to data for LLNL radiography and CT tools (e.g. LTT: https://softwarelicensing.llnl.gov/product/livermore-tomography-tools-ltt).

Vardar-Irrgang, MichaelE [Lawrence Livermore Natio↗

Preoperative Radiomic Approach to Evaluate Tumor-Infiltrating CD8{sup +} T Cells in Hepatocellular Carcinoma Patients Using Contrast-Enhanced Computed Tomography

Background: To help identify potential hepatocellular carcinoma (HCC) candidates for immunotherapies, we aimed to develop and validate a radiomics-based biomarker (Rad score) to predict the infiltration of tumor-infiltrating CD8{sup +} T cells in HCC patients, and to evaluate the correlation of Rad score with tumor immune characteristics. Methods: Overall, 142 HCC patients (n = 100 and n = 42 in the training and validation sets, respectively) were subjected to radiomic feature extraction. Imaging features and immunochemistry data of patients in the training set were subjected to elastic-net regularized regression analysis to predict the level of CD8{sup +} T cell infiltration. Results: A Rad score for CD8{sup +} T-cell infiltration, which contained seven variables, was developed and was validated in the validation set (area under the curve [AUC]: training set 0.751, 95% confidence interval [CI] 0.656–0.846; validation set 0.705, 95% CI 0.547–0.863). The decision curve indicated the clinical usefulness of the Rad score. A higher Rad score correlated with superior overall and disease-free survival outcomes (p = 0.012 and 0.0088, respectively). Using the pathological slides, we found that the Rad score positively correlated with the percentage of tumor-infiltrating lymphocytes (TILs; Spearman rho = 0.51, p < 0.0001). Moreover, the Rad score could also discriminate inflamed tumors from immune-desert and immune-excluded tumors (Kruskal–Wallis, p < 0.0001), and higher Rad scores could be found in patients with positive programmed cell death ligand 1 expression in tumor/immune cells, as well as those with positive programmed cell death protein 1 expression. Conclusion: The newly developed Rad score was a powerful predictor of CD8{sup +} T-cell infiltration, which could be useful in identifying potential HCC patients who can benefit from immunotherapies when validated in large-scale prospective cohorts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗