Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A Compact Topological Microwave Isolator

A central goal of topological photonics has been to develop compact isolators using protected, non-reciprocal edge states. Furthermore, a recent demonstration of a ferrite-based microwave isolator leverages the magnon-induced topological photonic bandgap to achieve over 100 dB of isolation in a device smaller than a single free-space wavelength.

Magneto-optics↗

Compact spectroscopy of keV to MeV X-rays from a laser wakefield accelerator

We reconstruct spectra of secondary X-rays from a tunable 250–350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Explainable machine learning for incipient anomaly detection in compact molten salt heat exchanger with overlapping feature distributions

High-temperature molten salt-cooled reactors (MSCRs) are a promising next-generation nuclear technology option, offering efficient power conversion and inherent safety features. However, the reliability of these systems depends on the robust operation of heat exchangers (HXs), which are susceptible to failure due to temperature gradients and channel plugging caused by fluid freezing. Conventional monitoring methods, relying on inlet and outlet measurements, lack the spatial resolution needed to detect early-stage faults. We propose a novel design of a compact salt-to-salt matrix-type HX design consisting of interleaved arrays of parallel tubes, with integrated synthetic fiber optic distributed temperature sensing (DTS) to enable localized detection of incipient faults. To evaluate performance of this design, we generate high-fidelity synthetic data using heat transfer computational modeling to simulate channel plugging, and introduce sensor noise for realistic modeling of measurements. The dataset comprises of 97% normal operation and 3% anomaly cases, with each anomaly class representing 1% of the data. These early anomalies result in overlapping temperature profiles between normal and faulty channels, producing a non-separable dataset that challenges traditional classification techniques. We benchmark eight supervised machine learning (ML) models and demonstrate that XGBoost achieves the highest performance. To improve transparency, we develop an explainability framework combining Shapley values and partially ordered sets (POSETs) to quantify and structurally analyze feature importance. This approach identifies both dominant predictors and ambiguous feature relationships, enhancing trust and interpretability. Our results highlight the potential of combining DTS and explainable ML with intelligent feature selection to improve predictive maintenance and ensure operational resilience in advanced nuclear systems.

Prantikos, Konstantinos [Argonne National Laborato↗

Compact monocrystalline silicon solar modules with high voltage outputs and mechanically flexible designs

Here, a type of compact (~cm 2 ) high voltage photovoltaic module that utilizes large collections of ultrathin (~15 μm), small (~45 μm wide, ~1 mm long) silicon solar cells was fabricated and characterized. Integration on thin sheets of plastic yielded flexible modules with per-cell efficiencies of ~8%, voltage outputs >200 V, and maximum power outputs >1.5 mW.

36 MATERIALS SCIENCE↗

Stochastic methods for aerosol chemistry: a compact molecular description of functionalization and fragmentation in the heterogeneous oxidation of squalane aerosol by OH radicals

The heterogeneous oxidation of organic aerosol by hydroxyl radicals (OH) can proceed through two general pathways: functionalization, in which oxygen functional groups are added to the carbon skeleton, and fragmentation, in which carbon–carbon bonds are broken, producing higher volatility, lower molecular weight products. An ongoing challenge is to develop a quantitative molecular description of these pathways that connects the oxidative evolution of the average aerosol properties (e.g. size and hygroscopicity) to the transformation of free radical intermediates. In order to investigate the underlying molecular mechanism of aerosol oxidation, a relatively compact kinetics model is developed for the heterogeneous oxidation of squalane particles by OH using free radical intermediates that convert reactive hydrogen sites into oxygen functional groups. Stochastic simulation techniques are used to compare calculated system properties over ten oxidation lifetimes with the same properties measured in experiment. The time-dependent average squalane aerosol mass, volume, density, carbon number distribution of scission products, and the average elemental composition are predicted using known rate coefficients. For functionalization, the calculations reveal that the distribution of alcohol and carbonyl groups is controlled primarily by the initial OH abstraction rate and to lesser extent by the branching ratio between secondary peroxy radical product channels. For fragmentation, the calculations reveal that the formation of activated alkoxy radicals with neighboring functional groups controls the molecular decomposition, particularly at high O/C ratios. Finally, this kinetic scheme provides a framework for understanding the oxidation chemistry of a model organic aerosol and informs parameterizations of more complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low thermal budget, photonic-cured compact TiO 2 layers for high-efficiency perovskite solar cells

Rapid advances in organometallic trihalide perovskite solar cells (PSCs) have positioned them to be one of the leading next generation photovoltaic technologies. However, most of the high-performance PSCs, particularly those using compact TiO 2 as an electron transport layer, require a high-temperature sintering step, which is not compatible with flexible polymer-based substrates. Considering the materials of interest for PSCs and corresponding device configurations, it is technologically imperative to fabricate high-efficiency cells at low thermal budget so that they can be realized on low-temperature plastic substrates. In this paper, we report on a new photonic curing technique that produces crystalline anatase-phase TiO 2 films on indium tin oxide-coated glass and flexible polyethylene terephthalate (PET) substrates. Finally, the planar PSCs, using photonic-cured TiO 2 films, exhibit PCEs as high as 15.0% and 11.2% on glass and flexible PET substrates, respectively, comparable to the device performance of PSCs incorporating furnace annealed TiO 2 films.

14 SOLAR ENERGY↗

Scalable open-air deposition of compact ETL TiO x on perovskite for fullerene-free solar cells

We report a scalable, low-temperature TiO x electron transport layer (ETL) produced directly on top of perovskite in an inverted architecture device by an open-air chemical vapor deposition (OA-CVD) process. The OA-CVD pyrolysis of a titanium ethoxide precursor forms a fully inorganic, conformal, and compact TiO x film. The resultant film is mechanically robust and exhibits a fracture toughness 30-fold higher than commonly used fullerene-based ETL films. The TiO x is an effective barrier layer against environmental degradation—unencapsulated devices with the TiO x ETL retain 60% of their initial efficiency after 1000 hours in ambient aging conditions—compared to devices with a fullerene ETL which were inoperable after 144 hours. Inverted architecture devices with an optimized TiO x ETL thickness of 70 nm exhibited high open-circuit voltages of 1.08 V. We comment on the photocatalytic properties of TiO x and the influence of an amorphous film on maximum power point stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a multi-functional gel polymer electrolyte with a 3D compact stacked polymer micro-sphere matrix for high-performance lithium metal batteries

We report lithium metal batteries (LMBs) are considered as promising high energy density batteries. However, they still suffer from poor cyclability due to the instability of solid electrolyte interphases (SEIs) and Li dendrite issues. Herein, a novel 3D densely packed multifunctional crosslinked gel polymer electrolyte (PHGPE) has been synthesized by in situ copolymerization of pentaerythritol tetraacrylate and 2-hydroxyethyl acrylate in a liquid electrolyte via a thermal initiation method. Due to intermolecular hydrogen bonding in the frameworks, the PHGPE exhibits a 3D compact-stacked and crosslinked micro-sphere structure, which benefits the construction of homogeneous Li + flux, enabling uniform Li plating/stripping and formation of robust SEIs onto the lithium electrode. Benefiting from the above advantages, symmetric Li cells in the PHGPE deliver excellent cyclabilities of 6000 h at a current density of 1 mA cm -2 (1 mA h cm -2 ) and 7700 h at 0.5 mA cm -2 (2 mA h cm -2 ). Moreover, the PHGPE has such a wide electrochemical window that it is compatible with both high-voltage LiNi 0.8 Co 0.1 Mn 0.1 O 2 and sulfur cathodes to realize long cycle life. Additionally, a LiFePO 4 based pouch size LMB also presents promising performance. Therefore, this study of the PHGPE has opened a new avenue for high-performance LMBs with excellent versatility and practicality.

25 ENERGY STORAGE↗

Polarization and variability of compact sources measured in Planck time-ordered data

This paper introduces a new Planck Catalog of Polarized and Variable Compact Sources (PCCS-PV) comprising 153 sources, the majority of which are extragalactic. The data include both the total flux density and linear polarization measured by Planck with frequency coverage from 30 to 353 GHz, and temporal spacing ranging from days to years. We classify most sources as beamed, extragalactic radio sources; the catalog also includes several radio galaxies, Seyfert galaxies, and Galactic and Magellanic Cloud sources, including H II regions and planetary nebulae. An advanced extraction method applied directly to the multifrequency Planck time-ordered data, rather than the mission sky maps, was developed to allow an assessment of the variability of polarized sources. Our analysis of the time-ordered data from the Planck mission, tod2flux, allowed us to catalog the time-varying emission and polarization properties for these sources at the full range of polarized frequencies employed by Planck, 30-353 GHz. PCCS-PV provides the time-and frequency-dependent, polarized flux densities for all 153 sources. To illustrate some potential applications of the PCCS-PV, we conducted preliminary comparisons of our measurements of selected sources with published data from other astronomical instruments. In summary, we find general agreement between the Planck and the Institut de Radioastronomie Millimétrique (IRAM) polarization measurements as well as with the Metsähovi 37 GHz values at closely similar epochs. Here, these combined measurements also show the value of PCCS-PV results and the PCCS2 catalog for filling in missing spectral (or temporal) coverage and helping to define the spectral energy distributions of extragalactic sources. In turn, these results provide useful clues as to the physical properties of the sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatially resolved gas and stellar kinematics in compact starburst galaxies

The kinematics of galaxies provide valuable insights into their physics and assembly history. Kinematics are governed not only by the gravitational potential, but also by merger events and stellar feedback processes such as stellar winds and supernova explosions. We aim to identify what governs the kinematics in a sample of SDSS-selected nearby starburst galaxies, by obtaining spatially resolved measurements of the gas and stellar kinematics. We obtained near-infrared integral-field K-band spectroscopy with VLT/SINFONI for 15 compact starburst galaxies. We derived the integrated as well as spatially resolved stellar and gas kinematics. The stellar kinematics were derived from the CO absorption bands, and Paα and Brγ emission lines were used for the gas kinematics. Based on the integrated spectra, we find that the majority of galaxies have gas and stellar velocity dispersion that are comparable. A spatially resolved comparison shows that the six galaxies that deviate show evidence for a bulge or stellar feedback. Two galaxies are identified as mergers based on their double-peaked emission lines. In our sample, we find a negative correlation between the ratio of the rotational velocity over the velocity dispersion (v rot /σ) and the star formation rate surface density. We propose a scenario where the global kinematics of the galaxies are determined by gravitational instabilities that affect both the stars and gas. This process could be driven by mergers or accretion events. Effects of stellar feedback on the ionised gas are more localised and detected only in the spatially resolved analysis. The mass derived from the velocity dispersion provides a reliable mass even if the galaxy cannot be spatially resolved. The technique used in this paper is applicable to galaxies at low and high redshift with the next generation of infrared-focussed telescopes (JWST and ELT).

79 ASTRONOMY AND ASTROPHYSICS↗

The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control and Safety Systems during the Second Long Shutdown of the Large Hadron Collider at CERN

The Electromagnetic Calorimeter (ECAL) is one of the subdetectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. Over this long period, several changes to both systems were necessary to correct issues, extend functionality and keep them in-line with current hardware technologies and the evolution of software platforms. Due to the constraints imposed on significant changes to a running system, major hardware and software upgrades were therefore deferred to the second LHC Long Shutdown (LS2). This paper presents the architectures of the CMS ECAL control and safety systems, discusses the ongoing and planned upgrades, details implementation processes and validation methods and highlights the expectations for the post-LS2 systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact ExB mass separator for heavy ion beams

A compact ExB mass separator that deflects beam by 30 deg. has been designed and built to prove its principle of operation. The main part of the separator is contained in a shielding box of 11 cm long, 9 cm wide, and 1.5 cm high. An electromagnet of 7 cm pole diameter produced variable magnetic field in the mass separation region instead of a couple of permanent magnets which is to be used in the final design. The experimental result agreed well with the theoretical prediction, and larger mass ions is bent with less magnetic field with the aid of the deflection electric field. The reduction in resolving power for mass separation due to the deflection electric field has been investigated experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics of a He{sup +} beam extracted from a compact magnetic bucket-type ion source

Performance of a compact He{sup +} ion source was investigated before installing it to the experiment system developed for studying the efficiency of autodetachment neutralization from He{sup -} to He{sup 0}. Dependence of the extracted ion current upon the plasma parameters and that upon the extraction voltage indicated that the source performance was limited by space charge effect. The beam emittance was measured with a multislit system for various operation conditions. The experimentally determined emittance agreed well with the emittance obtained from ion trajectories calculated with input plasma parameters measured by a Langmuir probe. The beam current density of 60 mA/cm{sup 2} and the emittance of less than 25{pi} mm mrad are expected to deliver enough current to the downstream of the He{sup -} neutralizer system to clarify factors affecting the final He{sup 0} intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gluon Vortices and Induced Magnetic Field in Compact Stars

The natural candidates for the realization of color superconductivity are the extremely dense cores of compact stars, many of which have very large magnetic fields, especially the so called magnetars. In this paper we discuss how a color superconducting core can serve to generate and enhance the stellar magnetic field without appealing to a magnetohydrodynamic dynamo mechanism.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact cantilever force probe for plasma pressure measurements

A simple, compact cantilever force probe (CFP) has been developed for plasma pressure measurements. It is based on the pull-in phenomenon well known in microelectromechanical-system electrostatic actuators. The probe consists of a thin (25 {mu}m) titanium foil cantilever (38 mm of length and 14 mm of width) and a fixed electrode separated by a 0.75 mm gap. The probe is shielded by brass box and enclosed into boron nitride housing with a 9 mm diameter window for exposing part of cantilever surface to the plasma. When the voltage is applied between the cantilever and the electrode, an attractive electrostatic force is counterbalanced by cantilever restoring spring force. At some threshold (pull-in) voltage the system becomes unstable and the cantilever abruptly pulls toward the fixed electrode until breakdown occurs between them. The threshold voltage is sensitive to an additional externally applied force, while a simple detection of breakdown occurrence can be used to measure that threshold voltage value. The sensitivity to externally applied forces obtained during calibration is 0.28 V/{mu}N (17.8 V/Pa for pressure). However, the resolution of the measurements is {+-}0.014 mN ({+-}0.22 Pa) due to the statistical scattering in measured pull-in voltages. The diagnostic temporal resolution is {approx}10 ms, being determined by the dynamics of pull-in process. The probe has been tested in the tokamak ISTTOK edge plasma, and a plasma force of {approx}0.07 mN (plasma pressure {approx}1.1 Pa) has been obtained near the leading edge of the limiter. This value is in a reasonable agreement with the estimations using local plasma parameters measured by electrical probes. The use of the described CFP is limited by a heat flux of Q{approx}10{sup 6} W/m{sup 2} due to uncontrollable rise of the cantilever temperature ({delta}T{approx}20 deg. C) during CFP response time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of compact electron cyclotron resonance ion source

The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C{sup 4+} ions; its performance such as beam intensity and stability has already reached the medical requirements. Therefore, the prototype development of the source for medical use is essentially finished. Recently, we have started a few studies on other applications of the source. One is the production of fullerenes in the ECR plasma and modified fullerenes with various atoms for new materials. A second application is the production of multiply charged ions (not only carbon) for ion implantation. In this paper, some basic experiments for these applications are reported.

36 MATERIALS SCIENCE↗

Compact 2.45 GHz microwave ion/atom source

Characteristics of a microwave driven 3.4 cm diameter compact ion/atom source equipped with permanent magnets were tested. The source can be mounted to a standard copper gasket flange, and microwave power is supplied through an N-type microwave connector. The ion source plasma was observed through an ion extraction hole with an optical emission spectrometer. Peak height of an optical line spectrum emission corresponding to atomic nitrogen increased in proportion to the microwave input power. Quadrupole mass spectrometer showed that N{sup +} and N{sub 2}{sup +} were the dominant species in the extracted ion beam. Nitrogen ion current density of 0.23 mA/cm{sup 2} was obtained with only 10 W discharge power and 6x10{sup -3} Pa source surrounding pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact soft x-ray spectrometer for plasma diagnostics at the Heidelberg Electron Beam Ion Trap

A compact flat-field soft x-ray grazing-incidence grating spectrometer equipped with a cryogenically cooled back-illuminated charge-coupled device camera was built and implemented at the Heidelberg Electron Beam Ion Trap. The instrument spans the spectral region from 1 to 37 nm using two different gratings. In slitless operation mode, it directly images a radiation source, in this case ions confined in an electron beam ion trap, with high efficiency and reaching hereby a resolving power of {lambda}/{delta}{lambda} congruent with 130 at 2 nm and of {lambda}/{delta}{lambda} congruent with 600 at 28 nm. Capable of automatized operation, its low noise and excellent stability make it an ideal instrument not only for spectroscopic diagnostics requiring wide spectral coverage but also for precision wavelength measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗