Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “circuitry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

One-way Doppler extractor

This paper presents a feasibility analysis, tradeoffs, and implementation for a one-way Doppler extractor system. A Doppler error analysis is discussed which shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared, and a 'Vernier' technique is presented which obtains high Doppler resolution with low-speed logic. Parameter tradeoffs and sensitivities for this Vernier technique are discussed, leading to a hardware design configuration. Also presented is a performance evaluation of the resulting breadboard model that verifies the theoretical performance predictions. The breadboard model contains the circuitry to interface with an S-band transponder, to extract the Doppler and time-interval counts, to compute navigational parameters by means of a microprocessor, and to display the results. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of better than 0.02 hertz for a one-second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

Nossen, E. J.↗

Design and performance of a modularized NaI/Tl/ detector /The Crystal Ball prototype/

A prototype NaI(Tl) detector (the Cluster of 54) of spherical geometry subtending a solid angle of 7.5% of 4pi at its center, has recently been assembled and tested. This detector consists of 54 close-packed but optically isolated NaI(Tl) modules and the associated electronic circuitry. The Cluster of 54 is the predecessor of an almost complete spherical detector, the Crystal Ball, which will cover 94% of 4pi. The latter detector is now under construction and is especially designed for the study of gamma-rays produced in electron-positron collisions at colliding beam facilities. This article outlines the mechanical, optical, and electronic assembly of the prototype system.

Chan, Y.↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗

Design concept of geostationary platform

The payload efficiency of communication satellites has typically averaged 25 to 30% while meteorology and earth observation satellites range from 30 to 35%. Improvement in solar cell efficiency, batteries, electric propulsion for stationkeeping, and solid-state circuitry will increase this efficiency in the future, but it will still be advantageous in the Shuttle era to reduce the expenditure for support systems. A platform that provides all the support functions could reduce the initial cost due to economics of scale and also reduce transportation cost. Three alternate configurations of a platform for geosynchronous orbit communications and meteorology missions are presented

Hamilton, E. C.↗

Decision-directed automatic gain control

Logic circuitry determines whether gain fluctuation are result of signal-strength changes or of atypical strings of like data symbols. Automatic Gain Control (AGC) system provides tight control that is independent of short-term, average, received signal energy and has negligible degrading effect on probability of error for signal.

Weber, W. J., III↗

Improved isolation in double-balanced mixers

Bypass circuit eliminates unwanted leakage in output RF signal. Correction circuit was developed for phase-shift-keyed transmitters. Principle can be adapted to correct leakage in other types of RF circuitry as well.

Stanton, P. H.↗

Electronic pictures from charged-coupled devices

Imaging system uses charge-coupled devices (CCD's) to generate TV-like pictures with high resolution, sensitivity, and signal-to-noise ratio. It combines detectors for five spectral bands as well as processing and control circuitry all on single silicon chip.

Mccann, D. H.↗

Teletype test unit

Device may be used to facilitate testing and fault isolation in teletype and modem systems that are used for communication by people who having hearing disabilities. Unit uses CMOS digital integrated circuitry which may be operated from relatively inexpensive battery of any voltage from 3 to 18 volts.

Couch, R. H.↗

Automatic thermal switch

Automatic thermal switch closes and opens heat-flow path in response to temperature changes. Control is used to regulate temperature in electronic circuitry or cryogenic refrigeration equipment.

Cunningham, J. W.↗

Window comparator for voltages

Circuit determines whether voltage is within preselected range of voltage levels.Device requires fewer components than previous window comparators and is less susceptible to errors from reference drift. Comparator is useful in process-control circuitry, measuring instruments, and checkout equipment.

Black, J. M.↗

Fluid velocity measuring device

A fluid velocity measuring device is described which, when placed in a freestream fluid flow, causes vortices to be formed at a frequency proportional to the flow rate of the fluid. Sensors on the device generate electric signals with frequency proportional to the rate of vortex creation and with relative mean amplitudes indicative of fluid flow direction. Electric circuitry translates the electric signals into indications of fluid speed and direction.

Thomas, D. F., Jr.↗

Optical effects module

The possible degradation of optical samples exposed to the effluent gases and particulate matter emanating from the payload of the space transportation system during orbital operations may be determined by measuring two optical parameters for five samples exposed to this environment, namely transmittance and diffuse reflectance. Any changes detected in these parameters as a function of time during the mission are then attributable to surface contamination or to increased material absorption. These basic functions are attained in the optical effects module by virtue of the following subsystems which are described: module enclosure; light source with collimator and modulator; sample wheel with holders and rotary drive; photomultipliers for radiation detection; processing and sequencing electronic circuitry; and power conditioning interfaces. The functions of these subsystems are reviewed and specified.

Source record↗

Investigation of the dynamic range problem and providing software support for the AOL system

The present scheme for providing system timing for the airborne oceanographic lidar (AOL) system is not completely satisfactory. The possibility of using a digital approach to generate the forty pulses needed to energize the gates leading to the charge digitizers was investigated. The solution in terms of general analog and digital circuitry is straightforward. The crystal oscillator provides a stable frequency source which is used as a clock to the ring counter. The ring counter propagates a pulse from stage one to stage forty. Each of the outputs has an amplifier for isolation. This design is easy to implement in the frequency range up to 50 MHZ. Because a gate pulse width of from about 2 to 6 ns is needed for the AOL system, this dictates an input clock frequency to the shift register of from 100 MHA to 500 MHA. Problems associated with generating pulses in this range of operation are examined and an alternate solution is discussed.

Source record↗

Phase conjugation method and apparatus for an active retrodirective antenna array

An active retrodirective antenna array wherein a reference array element is used to generate a phase reference which is replicated at succeeding elements of the array. Each element of the array is associated with a phase regeneration circuit and the phase conjugation circuitry of an adjacent element. In one implementation, the phase reference circuit operates on the input signal at the reference element, a voltage controlled oscillator (VCO) output signal and the input pilot signal at the next array element received from a transmission line. By proper filtering and mixing, a phase component may be produced to which the VCO may be locked to produce the phase conjugate of the pilot signal at the next array element plus a transmission line delay. In another implementation, particularly suited for large arrays in space, two different input pilot frequencies are employed.

Tausworthe, R. C.↗

Design, fabrication, and evaluation of charge-coupled devices with aluminum-anodized-aluminum gates

A 4-phase, 49 1/2 bit CCD shift register was designed and fabricated using two levels of aluminum metallization with anodic Al2O3 insulation separating the layers. Test circuitry was also designed and constructed. A numerical analysis of an MOS-RC transmission line was made and results are given to characterize performance for various conductivities. The electrical design of the CCD included a low-noise dual-gate input and a balanced floating diffusion output circuit. Metallization was accomplished both by low voltage DC sputtering and thermal evaporation. The audization was according to published procedures using a buffered tartaric acid bath. Approximately 20 wafers were processed with 50 complete chips per wafer. All devices failed by shorting between the metal levels at some point. Experimental procedures eliminated temperature effects from sintering and drying, anodic oxide thickness, edge effects, photoresist stripping procedures, and metallization techniques as the primary causes of failure. It was believed from a study of SEM images that protuberances (hillocks) grow up from the first level metal through the oxide either causing a direct short or producing a weak, highly stressed insulation point which fails at low voltage. The cause of these hillocks is unknown; however, they have been observed to grow during temperature excursions to 470 C.

Gassaway, J. D.↗

AIFTDS stand-alone RMDU flight test report

The remote multiplexer/digitizer unit for the airborne integrated flight test data system was subjected to a flight test environment in order to study its dynamic response and that of its associated instrumentation circuitry during an actual flight test. The shielding schemes and instrumentation used are described and the data obtained are analyzed.

Wilner, D. O.↗

Development of multipurpose radiometer

A radiometer has been developed for thermal vacuum testing at the Johnson Space Center. The radiometer: (1) measures incident or absorbed irradiance in the solar and/or infrared spectral regions, (2) measures emittance and absorptance, (3) has improved sensitivity, (4) is light in weight, (5) is rugged and very reliable, (6) is temperature-compensated, (7) requires no external control, circuitry or in situ calibration, and (8) has reduced operating costs.

Redman, R. S.↗