Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

The selection of imaging systems for planetary photography from space vehicles.

Discussion of the selection of a type of imaging system for a specific mission which will maximize the return of scientific data while keeping development risk and cost to acceptable limits. A representative example is given which shows that the parameters of the optimizing process range from the scientific objectives through the engineering and programming constraints of the spacecraft and mission, to the characteristics of the types of systems. The selections for all planetary missions flown to date have been imaging systems using image tube cameras. Film cameras and mechanical scan cameras, however, have unique advantages which should find application in planetary exploration.

Smokler, M. I.↗

Automatically-focusing microscope system for live tissue observation

System includes focus-sensing arrangement which controls servo to keep microscope constantly focused on target. Microscope objective is moved along optical axis. System includes two video cameras that are used as transducers for sensing focus. Incoming visual image is split by beam splitter so that one-half of information is fed to each camera.

Mansour, M. N.↗

Earth resources experiment package sensor performance evaluation. Volume 2: S191

An S191 performance summary based on ground testing and orbital operations in terms of pertinent parameters is provided. Additional tasks covering S191 short-wavelength radiometric calibration, data-acquisition camera, and viewfinder tracking system design criteria, radiometric comparison of S190A, S191, and S192, and wavelength calibration data are included as supplemental analyses. Descriptions of techniques employed in the performance analyses are also discussed. Final results of the evaluations in terms of significant performance degradation, sensor and system anomalies, and achieved performance are presented. Conclusions were based on S191 performance and interaction of S191 with the EREP system. Recommendations for additional analyses and improvements in design and operation are presented.

Kenney, G. P.↗

Servo-controlled intravital microscope system

A microscope system is described for viewing an area of a living body tissue that is rapidly moving, by maintaining the same area in the field-of-view and in focus. A focus sensing portion of the system includes two video cameras at which the viewed image is projected, one camera being slightly in front of the image plane and the other slightly behind it. A focus sensing circuit for each camera differentiates certain high frequency components of the video signal and then detects them and passes them through a low pass filter, to provide dc focus signal whose magnitudes represent the degree of focus. An error signal equal to the difference between the focus signals, drives a servo that moves the microscope objective so that an in-focus view is delivered to an image viewing/recording camera.

Mansour, M. N.↗

Spectrophotometry of the transient X-ray source A0620-00

Optical observations of the transient X-ray source A0620-00 over the wavelength range from about 3200 to 6600 A are analyzed which were made with the 5-m Hale telescope using a multichannel spectrometer, a digital spectrograph with a cooled integrating SIT vidicon, and an image photon-counting system attached to the camera of the coude spectrograph. Infrared observations at 1.65, 2.2, and 3.5 microns are also examined. Individual spectral lines of special interest are discussed, the E(B-V) color excess is estimated to be about 0.40, and a distance of 1200 pc is adopted. Analysis of the continuous spectrum yields several simple binary models. A specific model is proposed in which one of the continuum sources is an optically thick object characterized by a model atmosphere at a temperature of 25,000 to 30,000 K and the second source is either a cool black body at 4000 K or a partially optically thick source of bound-free plus free-free radiation from a hydrogen gas with an electron temperature of at least 100,000 K. Some possible parameters of these sources and of the accretion disk are considered.

Oke, J. B.↗

Spacecraft automatic umbilical system

An umbilical system design is described that incorporates all the features specified for a power system to payload interconnect capability. A proof-of-concept prototype of the umbilical system was built to determine experimentally the suitability of the threading characteristics of the ram mechanism and to verify freedom from cross threading. It is concluded that Berthing systems that utilize remote manipulator systems (RMS) can be simplified by using RMS targets, closed circuit TV cameras, tie into the RMS control system, and grapple-fixture and end-effector-like capture and secure mechanisms. To effect a remotely controlled umbilical interconnect in proximity with a manned spacecraft and to provide for extravehicular activity backup and maintenance capabilities, 18 different mechanisms are found to be necessary. The weight impact of proving for maintenance capability in a large multiple connector umbilical system was found to be in the order of +60 percent.

Goldin, R. W.↗

An automated mapping satellite system

Topographic maps are compiled by manually operated stereoplotters that recreate the geometry of two wide-angle overlapping stereo frame photographs. Continuous imaging systems such as strip cameras, electro-optical scanners, or linear arrays of detectors (push brooms) can also create stereo coverage from which topography can be compiled; however, the instability of an aircraft in the atmosphere makes this approach impractical. The benign environment of space permits a satellite to orbit the Earth with very high stability as long as no local perturbing forces are involved. Solid-state linear-array sensors have no moving parts and create no perturbing force on the satellite. Digital data from highly stabilized stereo linear arrays are amenable to simplified processing to produce both planimetric imagery and elevation data. A proposed satellite, called MAPSAT, could accomplish automated mapping in near real time. Image maps as large as 1:50,000 scale with contours as close as 20-m interval may be produced from MAPSAT data.

Colvocoreses, A. P.↗

Viking Lander Atlas of Mars

Half size reproductions are presented of the extensive set of systematic map products generated for the two Mars Viking landing sites from stereo pairs of images radioed back to Earth. The maps span from the immediate foreground to the remote limits of ranging capability, several hundred meters from the spacecraft. The maps are of two kinds - elevation contour and vertical profile. Background and explanatory material important for understanding and utilizing the map collection included covers the Viking Mission, lander locations, lander cameras, the stereo mapping system and input images to this system.

Liebes, S., Jr.↗

Eye directed view

This paper presents the concept of extended intelligence and describes modifications to a commercially available automaton, using state-of-the-art technology, that demonstrates the practical use of extended intelligence. The natural inclination of an operator to look beyond the boundaries of a work scene as presented on a video monitor is used to command the pan and tilt of television cameras. In a teleoperator system, this capability allows the natural expansion of a work scene without burdening the operator with either a trivial cerebral task or a time consuming motor task. The automaton is unobtrusive, allows complete operator freedom, and approaches full dependability of command response with minimal operator orientation.

Goode, P. W.↗

A CCD search for geosynchronous debris

Using the Spacewatch Camera, a search was conducted for objects in geosynchronous earth orbit. The system is equipped with a CCD camera cooled with dry ice; the image scale is 1.344 arcsec/pixel. The telescope drive was off so that during integrations the stars were trailed while geostationary objects appeared as round images. The technique should detect geostationary objects to a limiting apparent visual magnitude of 19. A sky area of 8.8 square degrees was searched for geostationary objects while geosynchronous debris passing through was 16.4 square degrees. Ten objects were found of which seven are probably geostationary satellites having apparent visual magnitudes brighter than 13.1. Three objects having magnitudes equal to or fainter than 13.7 showed motion in the north-south direction. The absence of fainter stationary objects suggests that a gap in debris size exists between satellites and particles having diameters in the millimeter range.

Gehrels, Tom↗

Thermal design of the Wide Field/Planetary Camera

The Wide Field/Planetary Camera is an imaging system developed by the Jet Propulsion Laboratory for the NASA Hubble Space Telescope currently scheduled to be launched in December 1989 aboard the space shuttle. The temperature control design of the instrument utilizes multilayered insulation, electric resistance heaters, aluminum/ammonia heat pipes, thermoelectric coolers, temperature control coatings, and space radiators. A feedback control system maintains stable sensor temperatures. Thermal capacitance maintains stable optics and electronics temperatures during transient conditions. Schedule slips and launch delays have allowed extensive thermal testing of the instrument. Six instrument thermal vacuum tests and a spacecraft thermal vacuum test were performed. Several modifications have been made to the instrument to correct icing and contamination problems that have been discovered during thermal vacuum testing. This paper describes the thermal design, last instrument thermal vacuum test, results, and thermal model correlation.

Garcia, R. D.↗

Vacuum Chuck Holds Filter Pad For Counting Particles

Microscope-stage holder keeps filter pad flat to keep it in focus. Specimen holder is special vacuum chuck that applies suction through flat screen. Suction keeps filter pad flat against specimen holder while microscope stage moving to scan areas denoted by grid. In microscope system equipped with video camera, image-analyzing/particle-counting computer, and automatic focus, use of stage speeds count considerably by eliminating need to stop frequently for manual refocusing. Technician free to perform other tasks while computer controls translation of stage and takes count automatically.

Berry, Anthony↗

Detection Of Motion With A Phase-Conjugate Mirror

Photorefractive image-processing apparatus generates images of rapidly moving objects and suppresses images of stationary and slowly moving objects. Resembles apparatus described in article, "Improved Interferometric Photorefractive Optical Processor", NPO-17773. Principle of operation similar, except system includes two video cameras and instead of transparencies, electro-optical spatial light modulators used to impress image information from video camera on laser beams.

Cheng, Li-Jen↗

Planetary Spectroscopy

The effort is divided into instrumentation and observational research. In the area of instrumentation, the primary objective is the maintenance and slow improvement of the CCD camera and data acquisition system for continuing use of any interested LPL user. The main goal of the observational research is CCD spectroscopic and imaging studies of the solar system in support of spacecraft investigations. The studies include the physical behavior of comets, the atmospheres of the gaseous planets, and the solid surfaces of satellites and asteroids.

Fink, Uwe↗

Local heat transfer measurement with liquid crystals on rotating surfaces including non-axisymmetric cases

An overview and summary of test methods and results are given for the problem of measuring local heat transfer on rotating surfaces that model gas turbine engine disks. Disk cavity situations generically similar to those encountered in the high pressure stage disk cooling are considered, with cooling air supplied both at or near the wheel centerline as well as through single or multiple jets impinging outboard on the wheel near the blade attachment region. In some situations provision has been made for ingestion into the disk-cavity from the gas path region radially outboard of the disk. Local heat transfer rates in all cases are determined from the color display from a thin coating of encapsulated liquid crystals sprayed onto the disk, in conjunction with use of a video camera and computer vision system. For cases with axisymmetric disk surfaces, the coated surfaces are illuminated and viewed continuously, and detailed radial distributions of local Nusselt number are obtained. For non-axisymmetric disk surfaces, such as encountered in the vicinity of bolt heads, the disk is illuminated with stroboscopic light, and a method has been developed and used to synchronize the computer frame grabber with the illumination.

Metzger, D. E.↗

Cathodoluminescence properties of components in enstatite chondrites

As a group, the enstatite chondrites are notable by the extremely low FeO content of most of their silicates. This property predisposes many of these materials to emit Cathodoluminescence (CL). Since examination of the CL properties of meteoritic components in ordinary and carbonaceous chondrites have proven to be a useful technique, we have initiated a survey of the enstatite chondrites in order to better characterize the chemical and physical properties of their luminescing phases. Because of the diversity encountered in this study, it is first necessary to describe the number and types of materials observed to emit CL in these meteorites. Two CL techniques were used. First, the initial survey work was conducted at low magnification using a Nuclide (now MAAS) Luminoscope mounted to a Wild MP binocular microscope equipped for photomicroscopy. The beam conditions used were 14 +/- KeV and 7 +/- 1 milliamps, with the beam focussed to the diameter of the field of view of the microscope at 20x (appox. 1.25 cm). Photomosaics were produced for each section using Ecktar 1000 film and an exposure time of 15 to 30 seconds. Second, high magnification (400x) photos were obtained of individual components of interest by mounting a 35mm camera to the optical system of the Cameca Camebax microprobe located at the Johnson Space Center. Beam conditions used were 15 KeV and 600 nA. Ecktar 1000 film was also used, but exposure times of 6 minutes were necessary to produce a useful image. The components in E chondrites that produce CL can be divided into four broad categories. These are clasts and aggregates, chondrules, matrix components, and refractory objects. Components in each category are discussed.

Dehart, John M.↗

Doppler global velocimetry: Development of a flight research instrumentation system for application to non-intrusive measurements of the flow field

Doppler Global Velocimetry (DGV) is a new diagnostic tool that offers potential for flow field measurements in flight by acquiring three-component velocity data in near real-time during flight maneuvers. The feasibility of implementation of a flight DGV system aboard NASA's High-Angle-of-Attack Research Vehicle (HARV) was addressed in this work by identifying the essential characteristics of a flight measurement system and by performing calibration and error tests. Results from this work were: an outline that establishes a preliminary basis for system configurations by analyzing measurement errors, installation issues, and operating requirements; measurement of the accuracy of the DGV technique using a laboratory breadboard DGV system based on a frequency-doubled Nd: YAG laser and iodine Absorption Line Filter (ALF), which showed excellent agreement between the DGV data and pilot measurements on a laminar flow jet with velocities of up to 150 m/sec; a survey of DGV system components and technologies that are relevant to the design of a flight measurement system, including a survey of cameras for the next generation DGV receivers; an assessment of the candidate lasers and absorption line filters for the flight system, resulting in a near-term recommendation of Nd: host lasers and an iodine ALF for both flight and wind tunnel applications.

Komine, Hiroshi↗

Discrete Gabor Filters For Binocular Disparity Measurement

Discrete Gabor filters proposed for use in determining binocular disparity - difference between positions of same feature or object depicted in stereoscopic images produced by two side-by-side cameras aimed in parallel. Magnitude of binocular disparity used to estimate distance from cameras to feature or object. In one potential application, cameras charge-coupled-device video cameras in robotic vision system, and binocular disparities and distance estimates used as control inputs - for example, to control approaches to objects manipulated or to maintain safe distances from obstacles. Binocular disparities determined from phases of discretized Gabor transforms.

Weiman, Carl F. R.↗