Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alternative energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

High-order cyclo-difference techniques: An alternative to finite differences

The summation-by-parts energy norm is used to establish a new class of high-order finite-difference techniques referred to here as 'cyclo-difference' techniques. These techniques are constructed cyclically from stable subelements, and require no numerical boundary conditions; when coupled with the simultaneous approximation term (SAT) boundary treatment, they are time asymptotically stable for an arbitrary hyperbolic system. These techniques are similar to spectral element techniques and are ideally suited for parallel implementation, but do not require special collocation points or orthogonal basis functions. The principal focus is on methods of sixth-order formal accuracy or less; however, these methods could be extended in principle to any arbitrary order of accuracy.

Carpenter, Mark H.↗

Impacts of Voltage-Based Grid Support Functions on Energy Production of PV Customers

This paper presents the impact of inverter grid- support functions (GSFs) on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, HI. These autonomous GSFs based on local voltage measurements are good alternatives to increase PV hosting capacity. However, these functions can result in PV energy curtailment to the customer, and this study addresses the concerns about the impact of inverter GSFs through detailed quasi-static time series (QSTS) simulations. It proposes four metrics: maximum and average GSF curtailment, average increased generation and average net generation change, to assess the impact of a given control on PV systems located on customer sites. It was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 range. A reliable relationship between curtailment and peak customer voltage is demonstrated, suggesting that peak voltage could be used as an indicator of customer curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges and future perspectives on sodium and potassium ion batteries for grid-scale energy storage

The energy crisis and environmental pollution require the advancement of large-scale energy storage techniques. Among the various commercialized technologies, batteries have attracted enormous attention due to their relatively high energy density and long cycle life. Nevertheless, the limited supply and uneven distribution of lithium minerals, as well as their high cost, has greatly hindered the application of lithium-ion batteries in large-scale energy storage. Therefore, building next-generation alternative rechargeable batteries that feature low cost, long service life, and high safety is of the utmost importance. Over the past several years, we have witnessed many successful research outcomes for sodium and potassium ion batteries (SIBs and PIBs) in regard to electrode and electrolyte materials. In this Perspective, we summarize the current developments on SIBs/PIBs and their challenges when facing practical applications, including their cost, energy density, ion diffusivity in solids/electrolytes/interphases, cycle life, and safety concerns. Furthermore, we provide an overview of strategies to overcome the remaining challenges for achieving better electrochemical performance. Finally, we outline several possible directions for the future development of these two battery chemistries, with the hope of aiding the transition from the laboratory to next-generation practical applications for SIBs/PIBs batteries in grid-scale energy storage.

Energy Storage↗

Submitting a Standard Compliance Annual Report: EPAct State and Alternative Fuel Provider Fleet Program User Guide

State government and alternative fuel provider fleets covered under the State and Alternative Fuel Provider Fleet Program (Program) established pursuant to the Energy Policy Act of 1992 (EPAct) may use the Compliance Reporting Tool to track and report on several compliance activities. These activities include, but are not limited to, completing Standard Compliance annual reports, Alternative Compliance notices of intent, and exemption requests. Covered fleets can access the Compliance Tool through the Program's website at https://epact.energy.gov/users/sign_in. Covered fleet points of contact should bookmark the Compliance Reporting Tool for future access. This user guide addresses how to complete and submit Standard Compliance annual reports, including getting started with reporting, submitting annual reports, submitting exemption requests, and viewing annual reports.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Highly reversible Zn metal anode enabled by sustainable hydroxyl chemistry

Rechargeable Zn metal batteries (RZMBs) may provide a more sustainable and lower-cost alternative to established battery technologies in meeting energy storage applications of the future. However, the most promising electrolytes for RZMBs are generally aqueous and require high concentrations of salt(s) to bring efficiencies toward commercially viable levels and mitigate water-originated parasitic reactions including hydrogen evolution and corrosion. Electrolytes based on nonaqueous solvents are promising for avoiding these issues, although full cell performance demonstrations with solvents other than water have been very limited. To address these challenges, we investigated MeOH as an alternative electrolyte solvent. These MeOH-based electrolytes exhibited exceptional Zn reversibility over a wide temperature range, with a Coulombic efficiency > 99.5% at 50% Zn utilization without cell short-circuit behavior for > 1,800 h. More important, this remarkable performance translates well to Zn || metal-free organic cathode full cells, supporting < 6% capacity decay after > 800 cycles at –40°C.

25 ENERGY STORAGE↗

Photovoltaic windows cut energy use and CO 2 emissions by 40% in highly glazed buildings

Buildings account for 30% of global energy use. The architectural trend across building sectors is toward more glass despite higher energy use and carbon emissions than opaque cladding alternatives. Numerous window technologies - low-emissivity coatings, triple glazing, dynamic tinting, and the more recently developed photovoltaic glass - have emerged in the last two decades as approaches to reduce building energy. However, a comprehensive understanding of where and how these window technologies can be installed to enable optimal energy savings under different climate conditions remains limited. Here we test window technologies using thousands of macroscale building-energy simulations for different climate zones and building designs to evaluate the associated net energy use and carbon-emissions reduction potential. Novel window technologies, especially photovoltaic windows with high thermal performance, offer energy savings in all climates, ranging from 10,000-40,000 GJ per year over substandard windows for a typical office building, resulting in up to 2,000 tons of annual CO 2 emissions reduction. Highly glazed, net-zero buildings are achievable via photovoltaic windows when combined with careful geometric considerations.

14 SOLAR ENERGY↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

Prediction of Long-Term Strength of Thermoplastic Composites Using Time-Temperature Superposition

Accelerated tests for composite failure were investigated. Constant ramp transverse strength tests on thermoplastic composite specimens were conducted at four temperatures from 300 F to 450 F and five duration times from 0.5 sec to 24 hrs. Up to 400 F, the time-temperature-superposition method produces a master curve allowing strength at longer times to be estimated from strength tests conducted over shorter times but at higher temperatures. The shift factors derived from compliance tests applied well to the strength data. To explain why strength behaved similar to compliance, a viscoelastic fracture model was investigated based on the hypothesis that the work of fracture for crack initiation at some critical flaw remains constant with time and temperature. The model, which used compliance as input, was found to fit the strength data only if the critical fracture energy was allowed to vary with stress rate. Fracture tests using double cantilever beam specimens were conducted from 300 F to 450 F over time scales similar to the strength study. The toughness data showed a significant change with loading rate, less variation with temperature, did not form a master curve, and could not be correlated with the fracture model. Since the fracture model did not fit the fracture data, an alternative explanation based on the dilatational strain energy density was proposed. However the usefulness of this model is severely limited because it relies on a critical parameter which varies with loading rate.

Reeder, James R.↗

Federal Facility Agreement and Consent Order: Nevada National Security Site Use Restriction Management Plan with ROTC 1

This Use Restriction Management Plan (URMP) provides the information needed to create, modify, and manage use restrictions (URs) for sites on the Nevada National Security Site (NNSS), and sites accessed through the NNSS main gate, that were closed using the corrective action alternative (CAA) of closure in place under the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). (Note: This pertains to those FFACO sites not managed by the U.S. Department of Energy [DOE], Legacy Management.) The closure in place alternative is used for sites closed with residual contamination at levels requiring corrective action as determined using the FFACO process. The URs contain and control all requirements for long-term monitoring. This URMP also serves as the single repository of the URs implemented under the FFACO that identify use restricted areas and contain the current requirements for inspections, maintenance, and monitoring of the UR. The requirements in these URs replace all requirements listed in previous documentation. This consolidates post-closure monitoring requirements into a single source that ensures completeness and consistency of UR requirements and information. Standardized UR forms were developed to clearly document post-closure requirements that are consistent with current protocols and to ensure consistent information is contained in the URs. Standard notification, summary, and site controls statements were developed for all URs with provisions to insert site-specific options in the text. Current protocols for Industrial Sites and Soils URs are defined in this document and in the Soils Risk-Based Corrective Action (RBCA) Evaluation Process (DOE/EMNV, 2018). The standardized UR forms that have been approved to date are listed in Appendix A. Additional UR forms will be added once the review and approval process has been completed.

54 ENVIRONMENTAL SCIENCES↗

Design update on the transition beamline for the CEBAF Energy Upgrade

For Jefferson Lab’s 22GeV upgrade, two new permanent-magnet Fixed-Field Alternating Gradient (FFA) arcs will be integrated to serve the accelerator’s six highest-energy recirculation passes. Connecting these FFA arcs to the existing linear accelerator (linac) requires a carefully engineered transition section. The current design has two parts where the first part adiabatically matches the beam dispersion and orbit trajectories, while the second part aligns the Twiss parameters (alpha and beta functions) with those at the linac entrance. Given the tight spatial constraints and multiple matching requirements, a genetic algorithm is being explored to optimize the beam optics matching. This paper presents the current progress in developing and optimizing this transition.

Accelerator Physics↗

Federal Best Practices: Core Principles of Sustainable Fleet Management

This document is designed to help agency fleet managers understand and implement optimal petroleum reduction strategies for each fleet location by evaluating the most appropriate combination of the four core principles of sustainable fleet management: Right-sizing the fleet to agency mission by implementing a vehicle allocation methodology study; Minimizing vehicle miles traveled; Increasing fleet fuel efficiency by replacing inefficient vehicles with more fuel-efficient vehicles, maintaining vehicles, driving more efficiently, and avoiding excessive idling; Optimizing cost-effective alternative fuel use, including maximizing utilization of existing alternative fuel infrastructure, installing alternative fuel infrastructure where practical (including electric vehicle charging stations), and aligning deployment of alternative fuel vehicles with fueling infrastructure.

30 DIRECT ENERGY CONVERSION↗

Grid Planning Impacts of Hydropower Growth and Decline

Hydropower and pumped storage hydropower (PSH) have a complex and uncertain future in the U.S. electricity system. On one hand, existing assets have the potential for an expanded role in integrating variable renewable energy while new deployment, particularly of PSH, can help meet growing needs for grid flexibility and improved reliability. On the other hand, challenging environmental and cost considerations could limit the extent of new investments in hydropower and PSH capacity and flexibility. This technical presentation demonstrates the use of a high-fidelity capacity expansion model of the U.S. electric grid (the National Renewable Energy Laboratory's Regional Energy Deployment System) to understand the impacts of alternative futures for the hydropower and PSH fleet, including scenarios of both growth and decline. Growth scenarios include new PSH deployment or improved hydropower flexibility, while scenarios of decline reduce the capacity or energy production potential of hydropower and PSH. Economic, environmental, and performance outcomes of the grid are compared across these scenarios to reveal the potential contributions of hydropower and PSH in the U.S. electric sector over the next several decades, focusing on changes to the grid technology mix, electric sector costs, electricity prices, and air emissions. This broad scenario approach demonstrates how flexible hydropower and PSH can help reduce air emissions and cost by complementing variable renewables, but the opposite can occur with reduced hydropower availability, particularly in the next decade. It is important to consider a wide range of scenarios and metrics to gain a national and regional understanding of hydropower's future in the United States.

capacity expansion↗

Arctic Deployment of a Fully Integrated Self-Powered Drifting Buoy Harvesting Wave Energy via a Triboelectric Nanogenerator

The Arctic Ocean remains one of the most poorly sampled regions on Earth, where improved in situ environmental monitoring is vital for advancing oceanographic and atmospheric studies. However, data collection efforts are constrained by the short operational lifespans and high costs of conventional systems. Drifting buoys powered by pendulum-driven wave energy harvesters offer a cost-effective alternative, yet earlier designs have neither been optimized for real-world wave conditions nor validated in the Arctic. In this study, we develop a self-powered drifting buoy that integrates a pendulum-driven triboelectric nanogenerator (TENG) system with a mechanical motion rectifier, a high-gear-ratio transmission, and power management circuits. Through coupled buoy–pendulum dynamic simulations and laboratory testing using a motion simulator, we identify an optimal pendulum mass of 1.6 kg (12.7% of total buoy weight) that maximizes energy output while maintaining buoy stability. Laboratory experiments achieved average power outputs of 12.7 mW under Arctic-like wave and temperature conditions. The system was successfully deployed in the Bering Sea, where it generated 11 J of energy in 3.1 m waves, marking the first Arctic deployment of a TENG-based drifting buoy for sea surface temperature monitoring. This work establishes a cost-effective framework for designing self-powered Arctic monitoring platforms and advances the feasibility of long-term environmental observations in real Arctic waters.

marine enerby↗

Tunable-Quantum-Well Infrared Detector

Proposed detector of infrared photons based on photon-assisted, resonant quantum-mechanical tunneling between adjacent energy wells in its semiconductor structure. Wavelength adjusted by changing applied voltage. Device contains alternating layers of different seminconductors which form double-quantum-well electron-energy structure. Tunable-quantum-well detectors made on single chip constitutes line imager. Many such devices stacked to form two-dimensional imaging device. Signal-processing circuitry integrated into chip at its lower end. Potential barriers and wells produced by alternating layers of different semiconductor materials. Steepness of slope proportional to applied electric field. Electric field and thicknesses and heights of barriers selected to favor photon-assisted, resonant quantum-mechanical tunneling at chosen photon frequency.

Maserjian, Joseph↗

Novel Electrowinning Reactor for the Energy-Efficient, Low- Cost Production of Rare Earth Metals

This project developed a novel neodymium (Nd) electrowinning reactor for energy-efficient electrowinning of Nd metal. Throughout this project we have developed an alternative chloride based molten salt electrolysis process. Our process lowers the specific electrical energy consumption compared to the state of the art, while producing reusable chlorine gas and eliminating direct CO2 and PFC emissions. Facilities required for implementing the project were setup and designs were finalized, and a standard operating procedure for safe operation of high temperature electrolysis cells was written. The electrowinning reactor was designed and constructed. Electrolysis experiments confirmed the ability to reproducibly electrowin Nd metal on a Mo cathode. The current efficiency for Nd electrowinning was measured as a function of applied current density in the presence of the separator. Successful electrowinning of Nd sponge at high current densities (200 mA/cm2 and above) at a current efficiency >80% was demonstrated using multiple techniques. Stable Nd electrowinning up to 10h at 250 mA/cm2 was demonstrated. All of these design advancements were used to develop a techno-economic and life cycle assessment model that demonstrated that our process could be operated at cost of less than $0.20/kg-Nd (~30% lower compared to state of the art when comparing electrolysis energy cost) with a >20% total reduction in global warming potential compared to the state of the art while generating no direct CO2 or perfluorocarbon emissions.

42 ENGINEERING↗

Global assessment of the carbon–water tradeoff of dry cooling for thermal power generation

Water scarcity and climate change are dual challenges that could potentially threaten energy security. Yet, integrated water–carbon management frameworks coupling diverse water- and carbon-mitigation technologies at high spatial heterogeneity are largely underdeveloped. Here we build a global unit-level framework to investigate the CO 2 emission and energy penalty due to the deployment of dry cooling—a critical water mitigation strategy—together with alternative water sourcing and carbon capture and storage under climate scenarios. We find that CO 2 emission and energy penalty for dry cooling units are location and climate specific (for example, 1–15% of power output), often demonstrating notably faster efficiency losses than rising temperature, especially under the high climate change scenario. Despite energy and CO 2 penalties associated with alternative water treatment and carbon capture and storage utilization, increasing wastewater and brine water accessibility provide potential alternatives to dry cooling for water scarcity alleviation, whereas CO 2 storage can help to mitigate dry cooling-associated CO 2 emission tradeoffs when alternative water supply is insufficient. By demonstrating an integrative planning framework, our study highlights the importance of integrated power sector planning under interconnected dual water–carbon challenges.

42 ENGINEERING↗

Shadow energy functionals and potentials in Born–Oppenheimer molecular dynamics

In Born–Oppenheimer molecular dynamics (BOMD) simulations based on the density functional theory (DFT), the potential energy and the interatomic forces are calculated from an electronic ground state density that is determined by an iterative self-consistent field optimization procedure, which, in practice, never is fully converged. The calculated energies and forces are, therefore, only approximate, which may lead to an unphysical energy drift and instabilities. Here, we discuss an alternative shadow BOMD approach that is based on backward error analysis. Instead of calculating approximate solutions for an underlying exact regular Born–Oppenheimer potential, we do the opposite. Instead, we calculate the exact electron density, energies, and forces, but for an underlying approximate shadow Born–Oppenheimer potential energy surface. In this way, the calculated forces are conservative with respect to the approximate shadow potential and generate accurate molecular trajectories with long-term energy stabilities. We show how such shadow Born–Oppenheimer potentials can be constructed at different levels of accuracy as a function of the integration time step, δt, from the constrained minimization of a sequence of systematically improvable, but approximate, shadow energy density functionals. For each energy functional, there is a corresponding ground state Born–Oppenheimer potential. These pairs of shadow energy functionals and potentials are higher-level generalizations of the original “zeroth-level” shadow energy functionals and potentials used in extended Lagrangian BOMD. The proposed shadow energy functionals and potentials are useful only within this extended dynamical framework, where also the electronic degrees of freedom are propagated as dynamical field variables together with the atomic positions and velocities. The theory is quite general and can be applied to MD simulations using approximate DFT, Hartree–Fock, or semi-empirical methods, as well as to coarse-grained flexible charge models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TEAMER: Results of Investigating Structural Design Concepts and Alternative Materials for a Wave Power System

Included here are materials from a study on the design of a three-body Wave Energy Converter (WEC) utilizing a heave plate, dual Power Take Offs (PTOs), and single point mooring. A material trade study has been conducted to evaluate the effects of introducing various metallic and fiber-reinforced polymer (FRP) elements to the design. The baseline design is C-Power's patented k2 Wave Power System (WPS). This Testing Expertise and Access for Marine Energy Research (TEAMER) Request for Technical Support (RFTS) 9 effort resulted in alternative designs of the WPS center member, the nacelle. The analysis resulting from this study will inform the design of a lightweight structure with lower manufacturing and operating costs that increases energy conversion and power-to-weight ratio of the device. The dataset contains several components: finite element analysis (FEA) data, hand calculations, and CAD models. FEA files includes those used for and generated by finite element simulations. Calculations include hand calculations performed using Microsoft Excel, which assess core laminate properties, buckling, and other structural aspects in accordance with risk management DNV-RP-C201 standards. CAD materials include Solidworks files for parts, assemblies, and drawings of the evaluated models.

16 TIDAL AND WAVE POWER↗