Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Impact of window temperature variations on ITER toroidal interferometer and polarimeter (TIP) measurements

Abstract The toroidal interferometer and polarimeter (TIP) is one of the primary electron density diagnostics on ITER. To meet measurement requirements over several thousand seconds, environmental factors such as changes in the window temperature, air temperature, and humidity, which can cause uncompensated phase drifts, must be minimized. This paper reports measurements of the phase shift induced by ZnSe and BaF₂ windows as their temperature is varied utilizing the TIP prototype. To accomplish these measurements, test pieces of BaF₂ and ZnSe are placed in a small oven that is located in one leg of the 10.59/5.22 micron two-color interferometer TIP prototype. The oven temperature was varied from room temperature to ∼90 °C, which is slightly higher than the expected window temperatures on ITER. The vibration compensated phase shifts measured for these two materials are dϕᵥ꜀ /dT/L = 0.0121 and −0.275 deg. /°C/cm −1 for BaF₂ and ZnSe, respectively. From these measurements, it was concluded that temperature variations of the environmental/secondary confinement barrier window and primary vacuum window have to be suppressed within approximately 1°C and 2°C, respectively, in order to passively meet the electron density measurement requirements in ITER.

Akiyama, T (ORCID:0000000198469795)↗

Deducing Electronic Unit Internal Response During a Vibration Test Using a Lumped Parameter Modeling Approach

During random vibration testing of electronic boxes there is often a desire to know the dynamic response of certain internal printed wiring boards (PWBs) for the purpose of monitoring the response of sensitive hardware or for post-test forensic analysis in support of anomaly investigation. Due to restrictions on internally mounted accelerometers for most flight hardware there is usually no means to empirically observe the internal dynamics of the unit, so one must resort to crude and highly uncertain approximations. One common practice is to apply Miles Equation, which does not account for the coupled response of the board in the chassis, resulting in significant over- or under-prediction. This paper explores the application of simple multiple-degree-of-freedom lumped parameter modeling to predict the coupled random vibration response of the PWBs in their fundamental modes of vibration. A simple tool using this approach could be used during or following a random vibration test to interpret vibration test data from a single external chassis measurement to deduce internal board dynamics by means of a rapid correlation analysis. Such a tool might also be useful in early design stages as a supplemental analysis to a more detailed finite element analysis to quickly prototype and analyze the dynamics of various design iterations. After developing the theoretical basis, a lumped parameter modeling approach is applied to an electronic unit for which both external and internal test vibration response measurements are available for direct comparison. Reasonable correlation of the results demonstrates the potential viability of such an approach. Further development of the preliminary approach presented in this paper will involve correlation with detailed finite element models and additional relevant test data.

random vibration response↗

The low frequency 2D vibration sensor based on flat coil element

Vibration like an earthquake is a phenomenon of physics. The characteristics of these vibrations can be used as an early warning system so as to reduce the loss or damage caused by earthquakes. In this paper, we introduced a new type of low frequency 2D vibration sensor based on flat coil element that we have developed. Its working principle is based on position change of a seismic mass that put in front of a flat coil element. The flat coil is a part of a LC oscillator; therefore, the change of seismic mass position will change its resonance frequency. The results of measurements of low frequency vibration sensor in the direction of the x axis and y axis gives the frequency range between 0.2 to 1.0 Hz.

58 GEOSCIENCES↗

In-situ synthesis of magnetic (NiFe{sub 2}O{sub 4}/CuO/FeO) nanocomposites

In-situ synthesis of magnetic nanocomposites with (NiFe{sub 2}O{sub 4}/CuO/FeO) crystal phases has been done using a sol-gel method by taking a non-stoichiometric composition of the precursors. The average particle size of the nanocomposites was calculated using X-ray diffraction (XRD) and high resolution tunneling electron microscope (HR-TEM) and it turns out to be {approx}20 nm. The vibrating sample magnetometer (VSM) measurements demonstrate the ferromagnetic nature of the nanocomposites. The synthesized nanocomposite was used to prepare magnetic fluid using tetramethylammonium hydroxide as a surfactant and its stability in the solution was also discussed. -- Graphical abstract: Magnetic nanocomposites containing (NiFe{sub 2}O{sub 4}/CuO/FeO) phases having particle size {approx}17 nm were synthesized by a sol-gel method. The synthesized nanocomposites exhibit ferromagnetic nature with small value of coercivity.

36 MATERIALS SCIENCE↗

National Transonic Facility Model and Tunnel Vibrations

Since coming online in 1984, the National Transonic Facility (NTF) cryogenic wind tunnel at the NASA Langley Research Center has provided unique high Reynolds number testing capability. While turbulence levels in the tunnel, expressed in terms of percent dynamic pressure, are typical of other transonic wind tunnels, the significantly increased load levels utilized to achieve flight Reynolds numbers, in conjunction with the unique structural design requirements for cryogenic operation, have brought forward the issue of model and model support structure vibrations. This paper reports new experimental measurements documenting aerodynamic and structural dynamics processes involved in such vibrations experienced in the NTF. In particular, evidence of local un-steady airloads developed about the model support strut is shown and related to well documented acoustic features known as "Parker" modes. Two-dimensional unsteady viscous computations illustrate this model support structure loading mechanism.

Edwards, John W.↗

Integrating Oil Debris and Vibration Gear Damage Detection Technologies Using Fuzzy Logic

A diagnostic tool for detecting damage to spur gears was developed. Two different measurement technologies, wear debris analysis and vibration, were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Test Rig. Experimental data were collected during experiments performed in this test rig with and without pitting. Results show combining the two measurement technologies improves the detection of pitting damage on spur gears.

Dempsey, Paula J.↗

Non-invasive fluid density and viscosity measurement

The noninvasively measurement of the density and viscosity of static or flowing fluids in a section of pipe such that the pipe performs as the sensing apparatus, is described. Measurement of a suitable structural vibration resonance frequency of the pipe and the width of this resonance permits the density and viscosity to be determined, respectively. The viscosity may also be measured by monitoring the decay in time of a vibration resonance in the pipe.

47 OTHER INSTRUMENTATION↗

The Infrared Spectrum of H 2 S from 1 to 5 µm

The absorption spectra of H 2 S from 2000 to 11 147 cm -1 have been obtained with spectral resolutions of 0.006, 0.012, and 0.021 cm -1 and optical paths of 1.5 m to 433 m using the Fourier transform spectrometer at Kitt Peak National Observatory/National Solar Observatory. The 20 new vibrational bands have been assigned for the first time and 8 others re-analyzed so that accurate energy levels, band origins, and rotational parameters could be determined for a total of 29 states. Experimental band centers have been modeled by vibrational calculations. Line intensity measurements and analysis are in progress. A prediction of the 4 µm bands of H 2 S is currently available.

absorption↗

CHLORINE ABUNDANCES IN COOL STARS

Chlorine abundances are reported in 15 evolved giants and 1 M dwarf in the solar neighborhood. The Cl abundance was measured using the vibration-rotation 1-0 P8 line of H{sup 35}Cl at 3.69851 μ m. The high-resolution L -band spectra were observed using the Phoenix infrared spectrometer on the Kitt Peak Mayall 4 m telescope. The average [{sup 35}Cl/Fe] abundance in stars with −0.72 < [Fe/H] < 0.20 is [{sup 35}Cl/Fe] = (−0.10 ± 0.15) dex. The mean difference between the [{sup 35}Cl/Fe] ratios measured in our stars and chemical evolution model values is (0.16 ± 0.15) dex. The [{sup 35}Cl/Ca] ratio has an offset of ∼0.35 dex above model predictions, suggesting that chemical evolution models are underproducing Cl at the high metallicity range. Abundances of C, N, O, Si, and Ca were also measured in our spectral region and are consistent with F and G dwarfs. The Cl versus O abundances from our sample match Cl abundances measured in planetary nebula and H ii regions. In one star where both H{sup 35}Cl and H{sup 37}Cl could be measured, a {sup 35}Cl/{sup 37}Cl isotope ratio of 2.2 ± 0.4 was found, consistent with values found in the Galactic ISM and predicted chemical evolution models.

79 ASTRONOMY AND ASTROPHYSICS↗

OARE and SAMS on STS-94/MSL-1

Four microgravity acceleration measurement instruments were included on MSL-1 to measure the accelerations and vibrations to which science experiments were exposed during their operation on the mission. The data were processed and presented to the principal investigators in a variety of formats to aid their assessment of the microgravity environment during their experiment operations. Two accelerometer systems managed by the NASA Lewis Research Center (LeRC) supported the MSL-1 mission: the Orbital Acceleration Research Experiment (OARE), and the Space Acceleration Measurement System (SAMS). In addition, the Microgravity Measurement Assembly (MMA) and the Quasi- Steady Acceleration Measurement (QSAM) system, both sponsored by the Microgravity Research Division, collected acceleration data as a part of the MSL-1 mission. The NIMA was funded and designed by the European Space Agency in the Netherlands (ESA/ESTEC), and the QSAM system was funded and designed by the German Space Agency (DLR). The Principal Investigator Microgravity Services (PIMS) project at the NASA Lewis Research Center (LeRC) supports Principal Investigators (PIs) of the Microgravity science community as they evaluate the effects of acceleration on their experiments. PIMS primary responsibility is to support NASA-sponsored investigators in the area of acceleration data analysis and interpretation. A mission summary report was prepared and published by PIMS in order to furnish interested experiment investigators with a guide for evaluating the acceleration environment during the MSL-1 mission.

Moskowitz, Milton↗

Coupled rotor/fuselage dynamic analysis of the AH-1G helicopter and correlation with flight vibrations data

Under a research program designated Design Analysis Methods for VIBrationS (DAMVIBS), existing analytical methods are used for calculating coupled rotor-fuselage vibrations of the AH-1G helicopter for correlation with flight test data from an AH-1G Operational Load Survey (OLS) test program. The analytical representation of the fuselage structure is based on a NASTRAN finite element model (FEM), which has been developed, extensively documented, and correlated with ground vibration test. One procedure that was used for predicting coupled rotor-fuselage vibrations using the advanced Rotorcraft Flight Simulation Program C81 and NASTRAN is summarized. Detailed descriptions of the analytical formulation of rotor dynamics equations, fuselage dynamic equations, coupling between the rotor and fuselage, and solutions to the total system of equations in C81 are included. Analytical predictions of hub shears for main rotor harmonics 2p, 4p, and 6p generated by C81 are used in conjunction with 2p OLS measured control loads and a 2p lateral tail rotor gearbox force, representing downwash impingement on the vertical fin, to excite the NASTRAN model. NASTRAN is then used to correlate with measured OLS flight test vibrations. Blade load comparisons predicted by C81 showed good agreement. In general, the fuselage vibration correlations show good agreement between anslysis and test in vibration response through 15 to 20 Hz.

Corrigan, J. C.↗

Electroplating hard magnetic SmCo for magnetic microactuator applications

Patterned SmCo thin films were electroplated from an aqueous solute containing glycine by using dc and pulse dc current on the beaker level. Micromolds prepared by photolithography allow an accurate pattern transfer for patterned deposition of the material. A flux guide of a magnetic microactuator was chosen as a pattern, and Al{sub 2}O{sub 3} was used as the substrate. Au and Cr were investigated as seed layer materials. The content of Sm in the SmCo films is strongly dependent on the applied cathodic current density. A relative Sm content of up to 13.8 at. % could be determined by energy dispersive x-ray (EDX) spectroscopy. The SmCo thin films were annealed at 560 deg. C in a vacuum oven. Vibrating sample magnetometer (VSM) measurements were applied to characterize the magnetic properties. This film features hard magnetic properties with an intrinsic coercivity H{sub ci} of up to 44 kA/m. Electron probe microanalysis (EPMA) measurements showed that up to 40 at. % of O may be integrated in these films. The phases in the deposited films were determined by applying X-ray diffraction (XRD) measurements. These films consist of a mixture of SmCo alloy, Sm oxide, and Co.

36 MATERIALS SCIENCE↗

Probing the electronic structure and spectroscopy of pyrrolyl and imidazolyl radicals using high-resolution photoelectron imaging of cryogenically cooled anions

High-resolution photoelectron imaging and photodetachment spectroscopy of cryogenically cooled pyrrolide and imidazolide anions are used to probe the electronic structure and spectroscopy of pyrrolyl and imidazolyl radicals. The high-resolution data allow the ground state vibronic structures of the two radicals to be completely resolved, yielding accurate electron affinities of 2.1433 ± 0.0008 eV and 2.6046 ± 0.0006 eV for pyrrolyl and imidazolyl radicals, respectively. Fundamental frequencies for eight vibrational modes of pyrrolyl and ten vibrational modes of imidazolyl are measured, including several nonsymmetric Franck–Condon-forbidden modes. Two electronic excited states are also observed for the two radicals, displaying diffuse spectral features in both systems. The observations of nonsymmetric vibrational modes in the ground states and the diffuse excited state features provide strong evidence for vibronic couplings between the ground state and the two close-by excited states. The 2-pyrrolide isomer is also observed as a minor species from the electrospray ionization source and the electron affinity of 2-pyrrolyl is measured to be 1.6690 ± 0.0030 eV along with five vibrational frequencies. Even though the HOMOs of both pyrrolide and imidazolide anions are p orbitals, photodetachment spectroscopy reveals completely different threshold behaviors for the two anions: a d-wave-dominated spectrum for pyrrolide and an s-wave-dominated spectrum for imidazolide. Furthermore, the current study provides a wealth of electronic and spectroscopic information, which is ideal to compare with more accurate vibronic coupling calculations for these two important radicals, as well as interesting information about the photodetachment dynamics of the two anions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advances in Ceramic Matrix Composite Blade Damping Characteristics for Aerospace Turbomachinery Applications

For advanced aerospace propulsion systems, development of ceramic matrix composite integrally-bladed turbine disk technology is attractive for a number of reasons. The high strength-to-weight ratio of ceramic composites helps to reduce engine weight and the one-piece construction of a blisk will result in fewer parts count, which should translate into reduced operational costs. One shortcoming with blisk construction, however, is that blisks may be prone to high cycle fatigue due to their structural response to high vibration environments. Use of ceramic composites is expected to provide some internal damping to reduce the vibratory stresses encountered due to unsteady flow loads through the bladed turbine regions. A goal of our research was to characterize the vibration viscous damping behavior of C/SiC composites. The vibration damping properties were measured and calculated. Damping appeared to decrease with an increase in the natural frequency. While the critical damping amount of approximately 2% is required for typical aerospace turbomachinery engines, the C/SiC damping at high frequencies was less than 0.2% from our study. The advanced high-performance aerospace propulsion systems almost certainly will require even more damping than what current vehicles require. A purpose of this paper is to review some work on C/SiC vibration damping by the authors for the NASA CMC turbine blisk development program and address an importance of the further investigation of the blade vibration damping characteristics on candidate CMC materials for the NASA s advanced aerospace turbomachinery engine systems.

Min, James B.↗

Probing Heterogeneous Charge Distributions at the α-Al 2 O 3 (0001)/H 2 O Interface

Unlike metal or semiconductor electrodes, the surface charge resulting from the protonation or deprotonation of insulating mineral oxides is highly localized and heterogeneous in nature. In this work the Stark active C≡N stretch of potassium thiocyanate is used as a molecular probe of the heterogeneity of the interfacial electrostatic potential at the α-Al 2 O 3 (0001)/H 2 O interface. Vibrational sum frequency generation (vSFG) measurements performed in the OH stretching region suggest that thiocyanate species organize interfacial water similarly to halide ions. Changes in the electrostatic potential are then tracked via Stark shifts of the vibrational frequency of the thiocyanate stretch. Our vSFG measurements show that we can simultaneously measure the vSFG response of SCN – ions experiencing charged and neutral surface sites. We assign local potentials of +308 and -154 mV to positively and negatively charged aluminol groups that are present at pH = 4 and pH = 10, respectively. Thiocyanate anions at positively charged surface sites and negatively charged surface sites and those participating in contact ion pairing adopt similar orientations and are oppositely oriented relative to thiocyanate ions near neutral surface sites. All four species followed Langmuir adsorption isotherms. Density functional theory–molecular dynamics (DFT-MD) simulations of SCN – near the neutral α-Al 2 O 3 (0001)/H 2 O interface show that the vSFG response in the C≡N stretch region originates from a SCN–H–O–Al complex, suggesting the surface site specificity of these experiments. To our knowledge this is the first spectroscopic measurement of local potentials associated with a heterogeneously charged surface. The ability to probe the evolution of local charges in situ could provide vital insight into many industrial, electrochemical, and geochemically relevant interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Short Duration Bioastronautics Investigation 1904: Human Factors Assessment of Vibration Effects on Visual Performance during Launch

The primary objective of the Short Duration Bioastronautics Investigation (SDBI) 1904 was to determine visual performance limits during Shuttle operational vibration and g-loads, specifically through the determination of minimal usable font sizes using Orion-type display formats. Currently there is little to no data available to quantify human visual performance under the extreme g- and vibration conditions of launch. Existing data on shuttle vibration magnitude and frequency is incomplete and does not address human visual performance. There have been anecdotal reports of performance decrements from shuttle crews, but no structured data have been collected. Previous work by NASA on the effects of vibration and linear g-loads on human performance was conducted during the Gemini era, but these experiments were performed using displays and controls that are dramatically different than current concepts being considered by the Constellation Program. Recently, three investigations of visual performance under vibration have been completed at NASA Ames Research Center: the first examining whole-body vibration, the second employing whole-body vibration coupled with a sustained g-load, and a third examining the effects of peak versus extended duration vibration. However, all of these studies were conducted using only a single x-axis direction (eyeballs in/out). Estimates of thrust oscillations from the Constellation Ares-I first stage are driving the need for realistic human performance requirements. SDBI 1904 was an opportunity to address the need for requirements by conducting a highly focused and applied evaluation in a relevant spaceflight environment. The SDBI was a companion effort to Detailed Test Objective (DTO) 695, which measured shuttle seat accelerations (vibration) during ascent. Data from the SDBI will serve an important role in interpreting the DTO vibration data. Both SDBI 1904 and DTO 695 were low impact with respect to flight resources, and combined, they represent an efficient and focused problem solving approach. This project provided (a) immediate data for developing preliminary human performance vibration requirements; (b) flight validated inputs for ongoing and future ground-based research; and (c) preliminary information related to Orion display format design.

Thompson, Shelby↗

Experimental validation of finite element and boundary element methods for predicting structural vibration and radiated noise

This research report is presented in three parts. In the first part, acoustical analyses were performed on modes of vibration of the housing of a transmission of a gear test rig developed by NASA. The modes of vibration of the transmission housing were measured using experimental modal analysis. The boundary element method (BEM) was used to calculate the sound pressure and sound intensity on the surface of the housing and the radiation efficiency of each mode. The radiation efficiency of each of the transmission housing modes was then compared to theoretical results for a finite baffled plate. In the second part, analytical and experimental validation of methods to predict structural vibration and radiated noise are presented. A rectangular box excited by a mechanical shaker was used as a vibrating structure. Combined finite element method (FEM) and boundary element method (BEM) models of the apparatus were used to predict the noise level radiated from the box. The FEM was used to predict the vibration, while the BEM was used to predict the sound intensity and total radiated sound power using surface vibration as the input data. Vibration predicted by the FEM model was validated by experimental modal analysis; noise predicted by the BEM was validated by measurements of sound intensity. Three types of results are presented for the total radiated sound power: sound power predicted by the BEM model using vibration data measured on the surface of the box; sound power predicted by the FEM/BEM model; and sound power measured by an acoustic intensity scan. In the third part, the structure used in part two was modified. A rib was attached to the top plate of the structure. The FEM and BEM were then used to predict structural vibration and radiated noise respectively. The predicted vibration and radiated noise were then validated through experimentation.

Seybert, A. F.↗

Permanent hydrophilization of outer and inner surfaces of polytetrafluoroethylene tubes using ambient air plasma generated by surface dielectric barrier discharges

We present an atmospheric pressure ambient air plasma technique developed for technically simple treatment of inner and/or outer surfaces of plastic tubes and other hollow dielectric bodies. It is based on surface dielectric barrier discharge generating visually diffuse plasma layers along the treated dielectric surfaces using water-solution electrodes. The observed visual uniformity and measured plasma rotational and vibrational temperatures of 333 K and 2350 K indicate that the discharge can be readily applied to material surface treatment without significant thermal effect. This is exemplified by the obtained permanent surface hydrophilization of polytetrafluoroethylene tubes related to the replacement of a high fraction (more than 80%) of the surface fluorine determined by X-ray photoelectron spectroscopy. A tentative explanation of the discharge mechanism based on high-speed camera observations and the discharge current and voltage of measurements is outlined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗