Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

What were the use patterns observed at the highly-utilized direct current fast charge sites?

This paper will examine the use of the most highly utilized DCFC units in the EV Project, and analyze the conditions under which the user elected to charge at those DCFCs. The DCFC stations examined for this paper had an average of 33 charge events per week. There were 20 DCFC stations that were used an average 20.8 to 66 times per week The user-based conditions evaluated for this paper include the battery’s indicated state-of-charge (SOC) at charge start, the distance away from home that the fast-charge took place, the day of the week that the PEV driver elected to fast-charge, and the time of day when the charge took place.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO 2 Brayton Cycle - Report

This report presents the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO 2 ) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO 2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

20 FOSSIL-FUELED POWER PLANTS↗

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO2 Brayton Cycle - Presentation

This presentation discusses the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO2) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

Brayton power cycle↗

Evaluating Utility Costs Savings for EV Charging Infrastructure [Slides]

This analysis was conducted under the first round of the Solar Energy Innovation Network (SEIN), a program led by the National Renewable Energy Laboratory (NREL) that assembles diverse teams of stakeholders to research solutions to real-world challenges associated with solar energy adoption. As part of the Solar Energy Innovation Network, NREL used a tool called REopt to evaluate the impact on utility costs of light duty electric vehicle (EV) charging stations in Minnesota. The analysis models EV chargers at medium offices in Minneapolis, Minnesota. Specifically, the analysis explores three questions: (a) How can photovoltaics (PV) and stationary storage be co-deployed with EV charging infrastructure to lower the cost of purchasing grid electricity? (b) What are the potential savings of co-locating EV charging infrastructure with (behind the meter of) a commercial building? and (c) What savings can be gained from optimizing the times at which the EVs are charged to decrease lifecycle costs? Note that this presentation is not indented to be presented widely, but is just to provide ReOpt outputs for the partner's use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Applying Non-Energy Impacts from Other Jurisdictions in Cost-Benefit Analyses of Energy Efficiency Programs: Resources for States for Utility Customer-Funded Programs

Avoided energy and capacity costs are the primary yardstick utilities use to determine which energy efficiency programs are cost-effective for their customers. But sometimes "non-energy impacts" — not commonly recognized as directly associated with energy generation, transmission and distribution — represent substantial benefits, such as improving comfort, air quality and public health. Considering whether and how to include non-energy impacts is an important part of cost-benefit analyses for these programs. This report offers practical considerations for deciding which non-energy impacts to include and how to apply values or methods from other jurisdictions. Researchers reviewed studies quantifying non-energy impacts used in 30 states and applied a five-point system to indicate transferability of a value or method from each study for 16 categories of non-energy impacts: Water resource costs and benefits; Other fuels costs and benefits; Avoided environmental compliance costs; Environmental impacts; Productivity; Health and safety; Asset value; Energy and/or capacity price suppression effects; Avoided costs of compliance with Renewable Portfolio Standard requirements; Avoided credit and collection costs; Avoided ancillary services; Comfort; Economic development and job impacts; Public health impacts; Energy security impacts; Increased reliability. The U.S. Department of Energy’s Building Technologies Office supported this work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process Intensification for Electrochemical Utilization of CO 2

The conversion of CO 2 to value-added products is an attractive approach for reducing the cost of CO 2 capture. Formic acid (FA) is a multipurpose industrial chemical feedstock for formic acid fuel cells, additives in the textile and agricultural sectors, cleaning products, and corrosion inhibitors. FA can be produced directly from CO 2 via a two-electron process facilitated with DC electricity supplied via renewable/intermittent power sources [1]. The state-of-the-art method for industrial FA production is the Kemira process, which uses methanol, sodium methoxide, and CO to produce methyl formate that is subsequently hydrolyzed to formic acid. Conversely, an electrochemical approach reduces the number of chemical input for FA production, but conventional electrochemical processes for CO 2 reduction to FA continue to suffer from selectivity issues where the electrocatalyst produces a wide range of products. These competing products include FA, hydrogen, carbon monoxide, methanol, and methane that reduce faradaic efficiency by up to 50% [2]. The CAER-Andora process features an enzymatic catalyst with high selectivity for FA production with turn-over-frequency >85 s-1. The CAER-Andora process combines an electrochemical cell that features graphite electrodes and an electrochemically facile charge mediator, combined with an immobilized proprietary catalyst inside a FA production cell. These processes work together to 1) reduce faradaic inefficiencies by producing only FA, 2) protect the valuable catalyst from deactivation by overpotentials, and 3) provide a modular system configuration that facilitates independent optimization of the electrochemical and production cells. Operating at <3 V, the CAER-Andora process currently produces ~1 mM FA/hour with >90% CO2 to FA conversion in the production cell, and progress towards the intensification of the CO 2 utilization process will be discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Implications of a regional resource adequacy program on utility integrated resource planning: Study for the Western United States

LBNL collaborated with the Western Interstate Energy Board and the University of Texas, Austin to investigate the implications of a regional resource adequacy (RA) program on utility integrated resource planning. This report is focused on an active policy discussion to develop a novel voluntary program to share capacity resource and improve RA in the Western Interconnection. This report identifies two RA components of IRP that will be highly impacted by a regional RA program: resource capacity accreditation and RA targets. There are at least four resources that will require specific attention for their capacity credit calculation: (1) variable renewable resources, (2) demand-side resources, (3) hydropower, and (4) contracts. It will then be necessary to decide on a RA target reliability metric (e.g., a planning reserve margin) that is at least the minimum requirement in IRPs to ensure consistency in RA requirement calculations. The report finds that load forecasting and transmission expansion analyses will be moderately impacted, but that most of IRP components will not be significantly impacted. The report includes (i) a review of traditional resource adequacy practices in IRP; (ii) a case study of an existing regional RA program that interacts with IRP (Southwest Power Pool) and (iii) an overview of the NWPP regional resource adequacy proposal that is the object of this work. This paper does not (1) advocate for or against a regional RA program for the NWPP, (2) make detailed design recommendations for this program, or (3) assess its benefits and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Policy and Regulatory Environment for Utility-Scale Energy Storage: India

This report is part of a series investigating the potential for utility-scale energy storage in South Asia. The first part of the work is focused on opportunities and barriers for energy storage within existing policy and regulatory frameworks in the region. This report applies the previously-developed Energy Storage Readiness Assessment to evaluate the policy and regulatory environment for energy storage in India. Forthcoming reports will expand this analysis to other countries in South Asia. These evaluations are designed to provide insights on the opportunities and barriers for energy storage growth and deployment in each country. The second part of this work consists of techno-economic analysis to understand the drivers of energy storage investments in South Asia. Using NREL’s power system planning and operational models of South Asia, this analysis will identify potential storage applications and growth under various cost, policy, and demand growth scenarios. In addition, the regulatory and policy barriers and incentive mechanisms identified in the first task will be incorporated into the modeling task to understand their impact on energy storage deployment and operation. Together these studies will inform the applications and value of energy storage on South Asia power systems and policy and regulatory pathways to realize this value.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Universal Utility Data Exchange (UUDEX) - Workflow Design - Rev 1

This workflow design document describes the process of establishing a Universal Utility Data Exchange (UUDEX) Connection between two or more UUDEX Endpoints. The existing processes required to establish a data link using Inter Control Center Communications Protocol (ICCP) are very time consuming, from both the perspectives of effort and calendar time. The intent of UUDEX is to provide a more streamlined alternative. The UUDEX Workflow is also used to establish UUDEX Connections to exchange data other than that found in traditional ICCP data exchanges such as exchanges of power system model files, security events and mitigations, disturbance reports, and market data.

97 MATHEMATICS AND COMPUTING↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Universal Utility Data Exchange (UUDEX) Phase 4 Demonstration Environment and Results

This report provides an overview of the environment used by the Pacific Northwest National Laboratory (PNNL) in the Universal Utility Data Exchange (UUDEX) Phase 4 demonstration, and description of the demonstrations performed in the environment. The UUDX Phase 4 demonstration took place on March 31, 2021, with representatives from PNNL and the two project sub-contractors, OATI and MITRE, performing the demonstration for members of the UUDEX Industry Advisory Board (IAB). The demonstration tasks were based on the previous Phase 3 demonstration but conducted in a multi-site environment. Additional demonstrations showed features that were developed since the Phase 3 demonstration. The development environment was constructed by PNNL programming staff using the previously developed UUDEX Functional Design, Protocol Design, and Workflow Design documents as a starting point. The environment was augmented with subject creation management and access control security data structures and workflows, and data exchange structure documents developed as part of Phase 3 and Phase 4.

97 MATHEMATICS AND COMPUTING↗

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

MARVEL Utilization Plan

This report provides a high-level overview of the utilization plan for the MARVEL microreactor. The main focus is on discussing testing and application-demonstration opportunities that leverage the reactor. With the reactor rapidly progressing towards demonstration, along with the short (2- year) operational window, it was deemed critical to establish a basis for how stakeholders can engage with the program and leverage the reactor as a testbed. This report discusses potential opportunities to use MARVEL, leveraging from data and design access to testing novel controls, and novel nuclear-electric and nuclear-heat applications. It provides guidance for interested stakeholders on potential funding opportunities that can be pursued to support tests during the operational lifetime of the reactor. The report discusses the recommended strategy for outreach and the organizational structure to review and select projects for participation. Interested stakeholders are encouraged to fill out a questionnaire on how they could leverage MAVEL at this link: https://qfreeaccountssjc1.az1.qualtrics.com/jfe/form/SV_72InKjSEz54Q2j4 It is important to emphasize that this is intended to be a living document (updated annually or as needed) with revisions issued as the MARVEL demonstration timeline evolves. Similarly, the framework for engagement is subject to change as the project progresses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the Ukrainian version of this report, see NREL/TP-7A40-90360 (https://www.nrel.gov/docs/fy24osti/90360.pdf).

14 SOLAR ENERGY↗

ТЕХНІКО-ЕКОНОМІЧНИЙ АНАЛІЗ ПОТЕНЦІАЛУ ІНТЕГРАЦІЇ РОЗПОДІЛЕНИХ ЕНЕРГЕТИЧНИХ РЕСУРСІВ ДЛЯ ВОДОКАНАЛУ М.ЧЕРВОНОГРАД В УКРАЇНІ [Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine] (Ukrainian Translation)

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the English version of this report, see NREL/TP-7A40-89599 (https://www.nrel.gov/docs/fy24osti/89599.pdf).

14 SOLAR ENERGY↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗