Three-Dimensional Dose Verification for Intensity-Modulated Radiation Therapy in the Radiological Physics Centre Head-and-Neck Phantom Using Optical Computed Tomography Scans of Ferrous Xylenol-Orange Gel Dosimeters

Purpose: To extend the Radiological Physics Centre (RPC) intensity-modulated radiation therapy dose verification protocol to three dimensions using optical computed tomography (CT) scans of ferrous xylenol-orange (FX) gels. Methods and Materials: The dosimetry insert in the RPC head-and-neck phantom was replaced with an FX cylindrical gel dosimeter. Two gels were calibrated, independently irradiated with 6-MV X-ray beams and scanned using laser and cone-beam (Vista{sup TM}) optical CT, respectively. For matching dose slices, measured dose distributions were compared with Pinnacle{sup 3} computed distributions. Results: Within high-dose regions and low gradients, doses measured using laser CT were 2% to 3% less than the computed dose, whereas with cone-beam CT they were 4% to 5% less. Inside the central 90% of the gel cylinder diameter, the fraction of voxels satisfying the two-dimensional gamma analysis (5% dose difference, 3-mm distance to agreement) with laser-beam- and cone-beam-measured dose distributions were 98.4% and 99.0%, respectively. A three-dimensional gamma analysis with cone-beam data revealed that 96.7% of voxels within the central 90% gel volume satisfied the above criteria. Within the axial and sagittal planes through the primary planning target volume (PTV), computed and measured doses using GAFChromic EBT film (RPC measured) and cone-beam scanned FX gel generally agreed. At equivalent points in the planning target volumes, computed, thermoluminescent dosimeter (RPC-measured), and gel point doses agreed to within 5.1% in absolute dose. Conclusions: Laser and cone-beam CT yield comparable dose distributions in high-dose regions. The RPC head phantom and optical CT-scanned FX gels can be used for accurate intensity-modulated radiation therapy dose verification in three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose From Megavoltage Computed Tomography Imaging

Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Ultrasound-Based (BAT) Prostate-Repositioning: A Three-Dimensional On-Line Fiducial-Based Assessment With Cone-Beam Computed Tomography

Purpose: To assess the accuracy of ultrasound-based repositioning (BAT) before prostate radiation with fiducial-based three-dimensional matching with cone-beam computed tomography (CBCT). Patients and Methods: Fifty-four positionings in 8 patients with {sup 125}I seeds/intraprostatic calcifications as fiducials were evaluated. Patients were initially positioned according to skin marks and after this according to bony structures based on CBCT. Prostate position correction was then performed with BAT. Residual error after repositioning based on skin marks, bony anatomy, and BAT was estimated by a second CBCT based on user-independent automatic fiducial registration. Results: Overall mean value (MV {+-} SD) residual error after BAT based on fiducial registration by CBCT was 0.7 {+-} 1.7 mm in x (group systematic error [M] = 0.5 mm; SD of systematic error [{sigma}] = 0.8 mm; SD of random error [{sigma}] = 1.4 mm), 0.9 {+-} 3.3 mm in y (M = 0.5 mm, {sigma} = 2.2 mm, {sigma} = 2.8 mm), and -1.7 {+-} 3.4 mm in z (M = -1.7 mm, {sigma} = 2.3 mm, {sigma} = 3.0 mm) directions, whereas residual error relative to positioning based on skin marks was 2.1 {+-} 4.6 mm in x (M = 2.6 mm, {sigma} = 3.3 mm, {sigma} = 3.9 mm), -4.8 {+-} 8.5 mm in y (M = -4.4 mm, {sigma} = 3.7 mm, {sigma} = 6.7 mm), and -5.2 {+-} 3.6 mm in z (M = -4.8 mm, {sigma} = 1.7 mm, {sigma} = 3.5mm) directions and relative to positioning based on bony anatomy was 0 {+-} 1.8 mm in x (M = 0.2 mm, {sigma} = 0.9 mm, {sigma} = 1.1 mm), -3.5 {+-} 6.8 mm in y (M = -3.0 mm, {sigma} = 1.8 mm, {sigma} = 3.7 mm), and -1.9 {+-} 5.2 mm in z (M = -2.0 mm, {sigma} = 1.3 mm, {sigma} = 4.0 mm) directions. Conclusions: BAT improved the daily repositioning accuracy over skin marks or even bony anatomy. The results obtained with BAT are within the precision of extracranial stereotactic procedures and represent values that can be achieved with several users with different education levels. If sonographic visibility is insufficient, CBCT or kV/MV portal imaging with implanted fiducials are recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Examining Margin Reduction and Its Impact on Dose Distribution for Prostate Cancer Patients Undergoing Daily Cone-Beam Computed Tomography

Purpose: To examine the dosimetric impact of margin reduction and quantify residual error after three-dimensional (3D) image registration using daily cone-beam computed tomography (CBCT) for prostate cancer patients. Methods and Materials: One hundred forty CBCTs from 5 prostate cancer patients were examined. Two intensity-modulated radiotherapy plans were generated on CT simulation on the basis of two planning target volume (PTV) margins: 10 mm all around the prostate and seminal vesicles except 6 mm posteriorly (10/6) and 5 mm all around except 3 mm posteriorly (5/3). Daily CBCT using the Varian On-Board Imaging System was acquired. The 10/6 and 5/3 simulation plans were overlaid onto each CBCT, and each CBCT plan was calculated. To examine residual error, PlanCT/CBCT intensity-based 3D image registration was performed for prostate localization using center of mass and maximal border displacement. Results: Prostate coverage was within 2% between the 10/6 and 5/3 plans. Seminal vesicle coverage was reduced with the 5/3 plan compared with the 10/6 plan, with coverage difference within 7%. The 5/3 plan allowed 30-50% sparing of bladder and rectal high-dose regions. For residual error quantification, center of mass data show that 99%, 93%, and 96% of observations fall within 3 mm in the left-right, anterior-posterior, and superior-inferior directions, respectively. Maximal border displacement observations range from 79% to 99%, within 5 mm for all directions. Conclusion: Cone-beam CT dosimetrically validated a 10/6 margin when soft-tissue localization is not used. Intensity-based 3D image registration has the potential to improve target localization and to provide guidelines for margin definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Positron Emission Tomography Compared With Mediastinoscopy for Delineating Involved Lymph Nodes in Stage III Lung Cancer: Insights for Radiotherapy Planning From a Surgical Cohort

Purpose: Mediastinoscopy is routinely carried out on the majority of nonmetastatic, non-small-cell lung cancer (NSCLC) patients in our institution. We used the results of mediastinoscopy from a Stage III NSCLC cohort to assess the reliability of positron emission tomography (PET) scans at identifying involved mediastinal lymph nodes (MLN) when used during radiotherapy planning. Methods and Materials: Mediastinoscopy was the gold standard. Characteristics of PET were calculated for nodal sensitivity. To compare the impact on contouring, theoretical nodal targets (NTs) containing involved MLNs were generated using PET and mediastinoscopy. We determined whether the NT derived from PET (NT-P) was equivalent to, greater than, or less than that seen with the mediastinoscopy (NT-M). Results: Data for 122 patients with Stage III NSCLC, treated between 2000 and 2004, were analyzed. After exclusions, 87 patients with Stage III disease by mediastinoscopy were analyzed. Overall PET sensitivity was 61% and positive predictive value was 94%. Of the 87 patients, 33 (38%) had no abnormal MLN findings by PET. Of 36 Stage IIIA cancer patients, 18 (50%) had NT-P equivalent to NT-M, 10 (28%) had smaller NT-Ps, and 8 (22%) had larger NT-Ps compared with NT-Ms. Of 18 Stage IIIB cancer patients, NTs were equivalent in 6 (34%); in 1 patient (5%) NT-P was larger than the corresponding NT-M, and in 11 (61%) smaller than the corresponding NT-M. Conclusions: In this study PET had modest sensitivity to detect MLN involvement and underestimated the extent of involved nodes for target definition. The role of PET in mediastinal contouring needs to be evaluated prospectively and ideally correlated with a pathology standard.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Lipiodol Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Hepatocellular Carcinoma

Purpose: To evaluate the influence of lipiodol on the proton beam range, which has not yet been determined. Methods and Materials: Two computed tomography (CT) data sets were obtained with a T25-flask containing lipiodol and water that was placed above a water phantom. The plan with the lipiodol CT images was performed, and then a verification plan was applied to the water CT images. The actual proton beam ranges in the lipiodol and water were measured under same conditions, and we compared the calculated proton beam range in the treatment planning system with measured values. Results: The calculated distal range in the treatment planning system was 12 cm in water, which was 3.87 cm longer than that in lipiodol (8.13 cm). In contrast, the measured distal range was 12 {+-} 0.01 cm in water, which was 0.21 {+-} 0.01 cm longer than that of lipiodol (11.78 {+-} 0.01 cm). A 3.65 {+-} 0.01-cm range shift was found in the calculated range compared with the measured range. For 10 hepatocellular carcinoma patients, the distal range in the verification plan with the corrected CT images in which the Hounsfield unit (HU) value of lipiodolized lesion was replaced with the average HU value of the surrounding tissue was 0.61 {+-} 0.26 cm (range, 0.26-0.99) longer than that in the plan with uncorrected CT images. Conclusions: It could be relevant for the purposes of range calculation of proton beams in the treatment planning system that the HU value of a lipiodolized lesion is replaced by the average HU value of the surrounding normal tiss0008.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Intrafractional Movement and Internal Motion in Radiotherapy of Rectal Cancer Using Megavoltage Computed Tomography

Purpose: The aim of this study was to provide estimates of setup and internal margins of patients treated for rectal carcinoma using helical tomotherapy and to assess possible margin adaptations. Using helical tomotherapy, highly conformal dose distributions can be created, and the integrated megavoltage computed tomography (MVCT) modality allows very precise daily patient positioning. In clinical protocols, however, margins originating from traditional setup procedures are still being applied. This work investigates whether this modality can aid in redefining treatment margins. Methods and Materials: Ten patients who were treated with tomotherapy underwent MVCT scanning before and after 10 treatments. Using automatic registration the necessary setup margin was investigated by means of bony landmarks. Internal margins were assessed by delineating and describing the mesorectal movement. Results: Based on bony landmarks, movement of patients during treatments was limited to 2.45 mm, 1.99 mm, and 1.09 mm in the lateral, longitudinal, and vertical direction, respectively. Systematic errors were limited to <1 mm. Measured movement of the mesorectal space was -1.6 mm ({+-} 4.2 mm) and 0.1 mm ({+-} 4.0 mm) for left and right lateral direction. In the antero-posterior direction, mean shifts were -2 mm ({+-} 6.8 mm) and -0.4 mm ({+-} 3.8 mm). Mean shifts in the cranio-caudal direction were respectively -3.2 mm ({+-} 5.6 mm) and -3.2 mm ({+-} 6.8 mm). Conclusions: The use of the integrated MVCT on the tomotherapy system can minimize the setup margin for rectal cancer, and can also be used to adequately describe the internal margin allowing for direct treatment margin adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Between In-Beam and Offline Positron Emission Tomography Imaging of Proton and Carbon Ion Therapeutic Irradiation at Synchrotron- and Cyclotron-Based Facilities

Purpose: The benefit of using dedicated in-beam positron emission tomography (PET) detectors in the treatment room instead of commercial tomographs nearby is an open question. This work quantitatively compares the measurable signal for in-beam and offline PET imaging, taking into account realistic acquisition strategies at different ion beam facilities. Both scenarios of pulsed and continuous irradiation from synchrotron and cyclotron accelerators are considered, because of their widespread use in most carbon ion and proton therapy centers. Methods and Materials: A mathematical framework is introduced to compare the time-dependent amount and spatial distribution of decays from irradiation-induced isotope production. The latter is calculated with Monte Carlo techniques for real proton treatments of head-and-neck and paraspinal tumors. Extrapolation to carbon ion irradiation is based on results of previous phantom experiments. Biologic clearance is modeled taking into account available data from previous animal and clinical studies. Results: Ratios between the amount of physical decays available for in-beam and offline detection range from 40% to 60% for cyclotron-based facilities, to 65% to 110% (carbon ions) and 94% to 166% (protons) at synchrotron-based facilities, and increase when including biologic clearance. Spatial distributions of decays during irradiation exhibit better correlation with the dose delivery and reduced influence of biologic processes. Conclusions: In-beam imaging can be advantageous for synchrotron-based facilities, provided that efficient PET systems enabling detection of isotope decays during beam extraction are implemented. For very short (<2 min) irradiation times at cyclotron-based facilities, a few minutes of acquisition time after the end of irradiation are needed for counting statistics, thus affecting patient throughput.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Does Magnetic Resonance Imaging Influence Staging According to AJCC Staging System for Nasopharyngeal Carcinoma Compared With Computed Tomography?

Purpose: To analyze the degree and pattern of influence of magnetic resonance imaging (MRI) on staging according to the 6th edition of the American Joint Committee on Cancer staging system compared with computed tomography (CT). Methods and Materials: The MRI and CT scans and medical records of 420 consecutive patients with newly diagnosed nasopharyngeal carcinoma (NPC) were analyzed retrospectively. The tumors of all patients were staged according to the 6th edition of the American Joint Committee on Cancer staging system. Results: A significant difference (p <0.05) was found between CT and MRI in demonstrating involvement in the oropharynx (CT, 25.0% vs. MRI, 14.5%), prevertebral muscle (CT, 18.4% vs. MRI, 36.0%), parapharyngeal space (CT, 82.6% vs. MRI, 68.8%), skull base (CT, 31.0% vs. MRI, 52.6%), sphenoid sinus (CT, 13.6% vs. MRI, 16.7%), ethmoid sinus (CT, 7.1% vs. MRI, 3.3%), intracranial area (CT, 4.8% vs. MRI, 16.0%), and retropharyngeal lymph nodes (CT, 52.1% vs. MRI, 69.0%). The incidence of cervical lymph node metastasis and lymph node metastasis at each level was similar according to CT and MRI. MRI resulted in changes in 49.8% of T stage cases, 10.7% of N stage cases, and 38.6% of clinical stage cases. Conclusion: MRI demonstrated early primary tumor involvement more precisely and deep primary tumor infiltration more easily. The use of MRI caused dramatic changes in the results of the T stage and clinical staging and should be preferred to CT in staging NPC. Patients would benefit from changes in treatment strategies resulting from the use of MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Differences for Computed Tomography and Magnetic Resonance Imaging Segmentation and Planning for Proton Prostate Cancer Therapy

Purpose: To determine the influence of magnetic-resonance-imaging (MRI)-vs. computed-tomography (CT)-based prostate and normal structure delineation on the dose to the target and organs at risk during proton therapy. Methods and Materials: Fourteen patients were simulated in the supine position using both CT and T2 MRI. The prostate, rectum, and bladder were delineated on both imaging modalities. The planning target volume (PTV) was generated from the delineated prostates with a 5-mm axial and 8-mm superior and inferior margin. Two plans were generated and analyzed for each patient: an MRI plan based on the MRI-delineated PTV, and a CT plan based on the CT-delineated PTV. Doses of 78 Gy equivalents (GE) were prescribed to the PTV. Results: Doses to normal structures were lower when MRI was used to delineate the rectum and bladder compared with CT: bladder V50 was 15.3% lower (p = 0.04), and rectum V50 was 23.9% lower (p = 0.003). Poor agreement on the definition of the prostate apex was seen between CT and MRI (p = 0.007). The CT-defined prostate apex was within 2 mm of the apex on MRI only 35.7% of the time. Coverage of the MRI-delineated PTV was significantly decreased with the CT-based plan: the minimum dose to the PTV was reduced by 43% (p < 0.001), and the PTV V99% was reduced by 11% (p < 0.001). Conclusions: Using MRI to delineate the prostate results in more accurate target definition and a smaller target volume compared with CT, allowing for improved target coverage and decreased doses to critical normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography to Estimate the Length of Gross Tumor in Patients With Squamous Cell Carcinoma of the Esophagus

Purpose: To determine the optimal method of using {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) to estimate gross tumor length in esophageal carcinoma. Methods and Materials: Thirty-six patients with esophageal squamous cell carcinoma treated with radical surgery were enrolled. Gross tumor volumes (GTVs) were delineated using three different methods: visual interpretation, standardized uptake value (SUV) 2.5, and 40% of maximum standard uptake value (SUV{sub max}) on FDG-PET imaging. The length of tumors on PET scan were measured and recorded as Length{sub vis}, Length{sub 2.5}, and Length{sub 40}, respectively, and compared with the length of gross tumor in the resected specimen (Length{sub gross}). All PET data were reviewed again postoperatively, and the GTV was delineated using various percentages of SUV{sub max}. The optimal-threshold SUV was generated when the length of PET matched the Length{sub gross}. Results: The mean ({+-}SD) Length{sub gross} was 5.48 {+-} 1.98 cm. The mean Length{sub vis}, Length{sub 2.5}, and Length{sub 40} were 5.18 {+-} 1.93 cm, 5.49 {+-} 1.79 cm, and 4.34 {+-} 1.54 cm, respectively. The mean Length{sub vis} (p = 0.123) and Length{sub 2.5} (p = 0.957) were not significantly different from Length{sub gross}, and Length{sub 2.5} seems more approximate to Length{sub gross.} The mean Length{sub 40} was significantly shorter than Length{sub gross} (p < 0.001). The mean optimal threshold was 23.81% {+-} 11.29% for all tumors, and it was 19.78% {+-} 8.59%, 30.92% {+-} 12.28% for tumors {>=}5 cm, and <5 cm, respectively (p = 0.009). The correlation coefficients of the optimal threshold were -0.802 and -0.561 with SUV{sub max} and Length{sub gross}, respectively. Conclusions: The optimal PET method to estimate the length of gross tumor varies with tumor length and SUV{sub max}; an SUV cutoff of 2.5 provided the closest estimation in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Kilovoltage Cone-Beam Computed Tomography With Megavoltage Projection Pairs for Paraspinal Radiosurgery Patient Alignment and Position Verification

Purpose: Implanted gold markers and megavoltage (MV) portal imaging are commonly used for setup verification of paraspinal tumors treated with high-dose, single-fraction radiotherapy. We investigated whether the use of kilovoltage cone-beam computed tomography (CBCT) imaging eliminates the need for marker implantation. Methods and Materials: Patients with paraspinal disease who were eligible for single-fraction stereotactic body radiotherapy were accrued to an institutional review board-approved protocol. Each of 16 patients underwent implantation of fiducial markers near the target. The markers were visible on the MV images. Three MV image pairs were acquired for each patient (initial, verification, and final) and were registered to the reference images. Every MV pair was complemented by a CBCT scan. CBCT image registration was performed automatically by maximizing the mutual information using a region of interest that excluded the markers. The corrections, as determined from the MV images, were compared with these from CBCT and were used for actual patient setup. Results: The mean and standard deviation of the absolute values of the differences between the CBCT and MV corrections were 1.0 {+-} 0.7, 1.0 {+-} 0.6, and 1.0 {+-} 0.8 mm for the left-right, anteroposterior, and superoinferior directions, respectively. The absolute differences between the corresponding pre- and post-treatment kilovoltage CBCT image registration were 0.6 {+-} 0.5, 0.6 {+-} 0.5, and 1.0 {+-} 0.8 mm. Conclusion: The setup corrections found using CBCT without the use of implanted markers were consistent with the marker registration on MV projections. CBCT has additional advantages, including better positioning precision and robust automatic three-dimensional registration, as well as eliminating the need for invasive marker implantation. We have adopted CBCT for the setup of all single-fraction paraspinal patients. Our data have also demonstrated that target displacements during treatment are insignificant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cine Computed Tomography Without Respiratory Surrogate in Planning Stereotactic Radiotherapy for Non-Small-Cell Lung Cancer

Purpose: To determine whether cine computed tomography (CT) can serve as an alternative to four-dimensional (4D)-CT by providing tumor motion information and producing equivalent target volumes when used to contour in radiotherapy planning without a respiratory surrogate. Methods and Materials: Cine CT images from a commercial CT scanner were used to form maximum intensity projection and respiratory-averaged CT image sets. These image sets then were used together to define the targets for radiotherapy. Phantoms oscillating under irregular motion were used to assess the differences between contouring using cine CT and 4D-CT. We also retrospectively reviewed the image sets for 26 patients (27 lesions) at our institution who had undergone stereotactic radiotherapy for Stage I non-small-cell lung cancer. The patients were included if the tumor motion was >1 cm. The lesions were first contoured using maximum intensity projection and respiratory-averaged CT image sets processed from cine CT and then with 4D-CT maximum intensity projection and 10-phase image sets. The mean ratios of the volume magnitude were compared with intraobserver variation, the mean centroid shifts were calculated, and the volume overlap was assessed with the normalized Dice similarity coefficient index. Results: The phantom studies demonstrated that cine CT captured a greater extent of irregular tumor motion than did 4D-CT, producing a larger tumor volume. The patient studies demonstrated that the gross tumor defined using cine CT imaging was similar to, or slightly larger than, that defined using 4D-CT. Conclusion: The results of our study have shown that cine CT is a promising alternative to 4D-CT for stereotactic radiotherapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Evaluation of Automatic Anatomy Segmentation Algorithm on Repeat or Four-Dimensional Computed Tomography Images Using Deformable Image Registration Method

Purpose: Auto-propagation of anatomic regions of interest from the planning computed tomography (CT) scan to the daily CT is an essential step in image-guided adaptive radiotherapy. The goal of this study was to quantitatively evaluate the performance of the algorithm in typical clinical applications. Methods and Materials: We had previously adopted an image intensity-based deformable registration algorithm to find the correspondence between two images. In the present study, the regions of interest delineated on the planning CT image were mapped onto daily CT or four-dimensional CT images using the same transformation. Postprocessing methods, such as boundary smoothing and modification, were used to enhance the robustness of the algorithm. Auto-propagated contours for 8 head-and-neck cancer patients with a total of 100 repeat CT scans, 1 prostate patient with 24 repeat CT scans, and 9 lung cancer patients with a total of 90 four-dimensional CT images were evaluated against physician-drawn contours and physician-modified deformed contours using the volume overlap index and mean absolute surface-to-surface distance. Results: The deformed contours were reasonably well matched with the daily anatomy on the repeat CT images. The volume overlap index and mean absolute surface-to-surface distance was 83% and 1.3 mm, respectively, compared with the independently drawn contours. Better agreement (>97% and <0.4 mm) was achieved if the physician was only asked to correct the deformed contours. The algorithm was also robust in the presence of random noise in the image. Conclusion: The deformable algorithm might be an effective method to propagate the planning regions of interest to subsequent CT images of changed anatomy, although a final review by physicians is highly recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Computed Tomography-Based Treatment Planning for Intensity-Modulated Radiation Therapy and Proton Therapy for Distal Esophageal Cancer

Purpose: To compare three-dimensional (3D) and four-dimensional (4D) computed tomography (CT)-based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. Methods and Materials: The IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Results: Compared with IMRT, median lung volumes exposed to 5, 10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%, 5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%, 8.4%, 5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index [CI], 1.99) and greater irradiation of the heart (heart-V40, 41.8%) compared with the IMRT plan(CI, 1.55, heart-V40, 35.7%) or the three-beam proton plan (CI, 1.46, heart-V40, 27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas filling. Conclusions: Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Four-Dimensional Computed Tomography for Analysis of Intrafractional and Interfractional Variation in Lung Volumes

Purpose: To assess the viability of four-dimensional (4D) computed tomography (CT) in describing intrafractional and interfractional changes in lung volumes and to determine which breathing phase, if any, produces the most highly reproducible lung volumes among fractions. Methods and Materials: Weekly 4D CT scans were acquired for 13 patients with non-small-cell lung cancer during a course of radiotherapy. Contours delineating the right lung, left lung, and total lung were obtained by adapting library models of the anatomic structures to the CT images and propagating them to all 10 respiratory phases represented in the 4D CT image data set. Lung volumes were calculated using software tools in a commercial radiation treatment-planning system and analyzed for interfractional volume reproducibility using t tests and for phase reproducibility using a phase-dependent uncertainty curve across all patients. Probability (p) values of <0.05 were considered to indicate significant differences in all comparisons. Results: The average mean coefficient of variation of tidal volume across all patients was 25.0%. The average standard deviation of tidal volumes was 5.7% relative to the lung volume at end-expiration. Total volumes measured at the 30% phase were 15% more consistent than those measured at end-inspiration (p = 0.03). Conclusions: Four-dimensional CT assesses lung volume with acceptable precision; but the technique was unable to accurately predict interfractional changes in lung volume because wide variations in intra- and interfractional breathing cause high uncertainties in 4D CT data acquisition. The most reproducible breathing phase seems to be at the 30-40% phase (just before end-expiration)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Interfraction Prostate Motion Using Megavoltage Cone Beam Computed Tomography

Purpose: Determine the degree of interfraction prostate motion and its components measured by using daily megavoltage (MV) cone beam computed tomography (CBCT) imaging. Methods and Materials: A total of 984 daily MV CBCT images from 24 patients undergoing definitive intensity-modulated radiotherapy for localized prostate cancer were analyzed retrospectively. Pretreatment couch shifts, based on physician registration of MV CBCT to planning CT data sets, were used as a measure of daily interfraction motion. Off-line bony registration was performed to separate bony misalignment from internal organ motion. Interobserver and intraobserver variation studies were performed on 20 MV CBCT images. Results: Mean interfraction prostate motion was 6.7 mm, with the greatest single-axis deviation in the anterior-posterior (AP) direction. The largest positional inaccuracy was accounted for by systematic deviations in bony misalignment, whereas random deviations occurred from bony misalignment and internal prostate motion. In the aggregate, AP motion did not correlate with days elapsed since beginning therapy or on average with rectal size at treatment planning. Interobserver variation was greatest in the AP direction, decreased in experienced observers, and further decreased in intraobserver studies. Mean interfraction motion during the first 6 days of therapy, when used as a subsequent offset, reduced acceptable AP planning target volume margins by 50%. Conclusion: The MV CBCT is a practical direct method of daily localization that shows significant interfraction motion with respect to conventional three-dimensional conformal and intensity-modulated radiotherapy margins, similar to that measured in other modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗