Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Tracking Restoration And Closure (TRAC): Status Update on Story Maps for Communicating Site Cleanup and Closure Status - 19033

The U.S. Department of Energy (DOE) Office of Environmental Management (EM) initiated the development of a customized, web-based mapping tool for communicating technical information on groundwater plumes at sites within the EM complex. Although the online tool was initially conceived to be a simple conversion of a paper report on contaminant plume sizes, remedial approaches, and regulatory status, it has advanced to providing specific information on cleanup status and site closure. The story maps provide robust geospatial visualization of plumes at DOE sites, as well as explanatory text, photographs, and video for an entire site, or for a management unit within the site. This collection of story maps is called TRAC (Tracking Restoration And Closure), and not only communicates information for each individual site, but also summarizes pertinent metrics on cleanup and remaining contaminants across all EM sites. TRAC is focused on communicating cleanup status, technical challenges, and needs for site closure, with a key challenge of transforming data into relevant, easily understood information. Although DOE managers are the target audience, the story maps can also be used to contribute to public understanding of groundwater cleanup progress at EM sites. Unlike the data access tools maintained at some EM sites (e.g., Hanford, Portsmouth, and Paducah), TRAC is neither a portal for data downloads, nor a tool for performing data analytics. Rather, the goal of TRAC is to provide relevant information on cleanup progress and closure that is consistent across all sites, allowing the user to view summary information across all sites, or examine information relevant to a particular site. This information sharing is needed to maintain open communications with interested parties and communicate efforts that ensure long-term protection of human health and the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance improvement of an extraction Lambertson septum magnet in the SNS accumulator ring

The SNS ring Extraction Lambertson Septum magnet contains a strong skew quadrupole term, which has been identified as the source of causing a beam profile distortion on the target. We have performed 3D computer simulations to study the magnetic field quality in the magnet. The skew quad term is computed with different methods in simulations and is compared to measurement data. The origin of the large skew quad term is thoroughly investigated. The remedy for minimizing the skew quad term by modifying the magnet is proposed. Particle tracking is performed to verify the beam profile evolution through the existing and modified septum. The magnetic interference to the septum performance from an adjacent quadrupole is also assessed.

43 PARTICLE ACCELERATORS↗

SU-G-TeP3-07: On the Development of Mechano-Biological Assessment of Leukemia Cells Using Optical Tweezers

Purpose: Patients with BCR-ABL (Ph +ve) acute lymphoblastic leukemia are at very high risk of relapse and mortality. In line with the NIH mission to understand the physical and biological processes, we seek to report mechano-biological method to assessment and distinguish treated/untreated leukemia cells. Methods: BCR-ABL leukemia cell populations and silica microspheres were trapped in a 100x magnification optical trapping system (λ=660 nm, 70 mW). Light refracted through the trapped sample was collected in the back focal plane by a quadrant detector to measure the positions of individual cells. The sample was driven at a known frequency and amplitude with a flexure translation stage, and the target’s response was recorded. The measured response was calibrated using the known driving parameters, and information about cell movements due to mechano-biological effects was extracted. Two leukemia cell populations were tested: a control group and a group treated with 2 Gy. Results: The mechano-biological movements of 10 microspheres, control cells, and treated cells were tracked over a ∼30 minute window at 1 minute intervals. The microsphere population did not see significant change in mechano-biological movements over the testing interval and remained constant. The control cell population saw a two-fold rise in activity that peaked around 1200 seconds, then dropped off sharply. The treated cell population saw a two-fold rise in activity that peaked at 400 seconds, and dropped off slowly. Conclusion: The investigated technique allows for direct measurement the movements of a trapped object due to mechano-biological effects such as thermal and extracellular motion. When testing microspheres, the mechano-biological activity remained constant over time due to the lack of biological factors. In both the control and treated cell populations, the mechano-biological activity was increased, possibly due to mitochondrial activation. This extra activity decreased over time, possibly due to cellular damage from trapping radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vortex rings in event-by-event relativistic heavy-ion collisions

We present event-by-event simulations for central asymmetric light+heavy and Au +Au collisions to investigate the formation and evolution of vortex-ring structures in the longitudinal flow velocity profile. The production-plane polarization of Λ hyperons, defined with respect to the Λ momentum and the beam, can track the “vortex-ring” feature in the event, a characteristic vortical structure generated by longitudinal flow gradients. We make comprehensive model predictions for the rapidity-dependent vortex-ring observables for different collision system sizes at √s NN = 200 and 72 GeV. Furthermore, our predictions at the latter energy can be explored in the future LHCb fixed-target experiment at the Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Economic Optimal Control for Minimizing Fuel Consumption of Heavy-Duty Trucks in a Highway Environment

This paper provides a comparative assessment of three economic optimal control strategies, aimed at minimizing the fuel consumption of heavy-duty trucks in a highway environment, under a representative lead vehicle model informed by traffic data. These strategies fuse a global, offline dynamic programming (DP) optimization with online model predictive control (MPC). We then show how two of the three strategies can be adapted to accommodate the presence of traffic and optimally navigate signalized intersections using infrastructure-to-vehicular (I2V) communication. The MPC optimization, which is local in nature, makes refinements to a coarsely (but globally, subject to grid resolution) optimized target velocity profile from the DP optimization. The three candidate economic MPC formulations that are evaluated include: a nonlinear time-based formulation that directly penalizes predicted fuel consumption, a nonlinear time-based formulation that penalizes braking effort as a surrogate for fuel consumption, and a linear distance-based convex formulation that maintains a tradeoff between energy expenditure and tracking of the coarsely optimized velocity profile obtained from DP. Using a medium-fidelity Simulink model, based on a Volvo truck's longitudinal and engine dynamics, we analyze the optimization's performance on four highway routes under various traffic scenarios. Results demonstrate 3.7-8.3% fuel economy improvement on highway routes without traffic and 6.5-10% on the same routes with traffic included. Furthermore, we present a detailed analysis of energy usage by "type" (aerodynamic losses, braking losses, and comparison of brake-specific fuel consumption), under each candidate control strategy.

33 ADVANCED PROPULSION SYSTEMS↗

SU-E-J-44: Design a Platform and Phantom Model for Photoacoustic Imaging in Combination with CT

Purpose: Our (long-term) objective is to develop a US manipulator that will provide in situ radiation response and image-guided therapy for bladder cancer based on photoacoustic molecular imaging. Methods: A platform was devised to provide a reproducible positional frame of reference for targeting anatomic structure between MDCT and US scans, in lieu of CBCT, and to fuse photoacoustic molecular imaging. US and photoacoustic scans are taken of a patient while in the CT scanner and IRMT. Through co-registration, based on anatomical positions, we identified a common coordinate system to be used in Eclipse. A bladder phantom was constructed to validate anatomical tracking via US and photoacoustic imaging. We tested the platform using phantom model to demonstrate validity once moved from the CT couch to the linear accelerator couch. Results: This platform interlocks with Varian exact couch index points for reproducibility of positioning. Construction from low Z material and sized appropriately to fit in CT/IMRT gantry. Error in conversion from cylindrical coordinates of the manipulator to X, Y, Z coordinates of the treatment couch was less than 1mm. We measured the bladder size in 3 different directions in both Eclipse from the CT and Acuson from US. The error was less than 2mm in all directions. CT and US images were co-registered in MATLAB. Co-registration of photoacoustic images is still being developed. Conclusion: For Linear Accelerators without on board imaging, MV portal images are not a viable option for the localization of soft tissue anatomy. We believe our manipulator provides an alternative using US imaging, which will be examined in an upcoming clinical trial. We plan to examine the value of hypoxia guided treatment through photoacoustic imaging during this trial.

60 APPLIED LIFE SCIENCES↗

Yet Another Hauser-Feshbach Code

Code framework to perform simulations of nuclear reactions with incident particles including gammas, protons, neutrons, deuterons, tritons, helium-3, and alphas to develop nuclear data libraries and study nuclear reaction phenomona. The code can model nuclear reactions or initial populations specified by the user. The decays principally follow the compound-nucleus hypothesis and the statistical decay of Hauser and Feshbach. The code models nuclear decays with a Monte Carlo process that tracks the decay of each state. Data libraries are produced that can be translated into GNDS (generalized Nuclear Data Structure). YAHFC can also be used as an event generator, with individual decays written to disk for offline analysis. Both serial and MPI versions are provided. YAHFC does NOT perform transport of nuclear reactions through materials, only the primary reaction with a target material.

Ormand, WilliamE.↗

Global Trends of ASME "N-Stamp" Certifications for Nuclear Component Vendors

Historically, nuclear component manufacturing vendors, from small businesses through large conglomerates, have felt compelled to obtain an American Society for Mechanical Engineers (ASME) Nuclear Certification, known colloquially as an "N-stamp", to assure supply chain quality standards that will be acceptable to regulators and safety concerns. Since the N-stamp quality standard is a U.S.-origin code, combined with the apparent decline in the U.S. nuclear industry alongside the growth of the Asian nuclear industry, there is the question of whether the rest of the world, including new entrants to the nuclear industry, also regard N-stamp as a needed certification. This study addresses this question through analysis of the entire N-stamp database of holders, and former holders, of N-stamp certificates of all types and for all regions worldwide from 1989-2020 (the dates available in the database). From this 30 years of data, we find that actually U.S.-based vendors still consistently obtain the largest number of N-stamps worldwide over all time periods, but also find that the countries participating in the N-stamp certification process has broadly expanded beyond just North America, Japan, S. Korea and Western Europe (the primary N-stamp recipients before the mid-2000's). We produced global heats maps and bar charts to illustrate our findings, as well as further investigation into why the data shows changes over time and region. We note that nuclear entities involved with Soviet-type reactors do not participate in the N-stamp process, but instead pursue the Russian version PNAE, which is substantially similar to the ASME code. We conclude that at least from the N-stamp database, the United States nuclear component manufacturing industry is alive and well, although there have been some consolidations, and that the ASME N-stamp appears to still be a valued certificate worldwide, including in China which now ranks second only to the United States in obtaining N-stamp certificates in recent years. We further note that the vendors of new reactor types, in particular High Temperature Gas-Cooled Reactors (HTGRs) and Small Modular Reactors (SMRs), are actively engaged with ASME (and other U.S.-based nuclear standards bodies such as the American Nuclear Society and Nuclear Energy Institute) to coordinate updates to the ASME N-Stamp criteria to ensure applicability of the code for these new designs. Implications of these findings include the following: The global use of the U.S.-origin N-stamp certification supports the view that, despite the decline of the U.S. nuclear industry, the United States remains an esteemed global leader in the area of nuclear safety. As the U.S. Government works to revitalize the U.S. nuclear industry, especially in the area of exports, it may be beneficial to leverage the global standing of the N-stamp certification. The findings indicate that the N-stamp database would be a useful tool for the U.S. Government to use to track the growth of the civil nuclear industry in foreign countries, under certain circumstances. The Excel-format N-stamp database produced as part of this study may be a useful tool for this purpose. N-stamp data may be a useful tool for foreign governments to use to identify nuclear manufacturers within their own country, especially to identify "targets" for outreach on nuclear export control compliance. The U.S. Government could carry this message to foreign partners during bilateral engagements or as part of Nuclear Suppliers Group (NSG) discussions on industry outreach.

42 ENGINEERING↗

Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D{sub 1} increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D{sub 5} dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CHICO2, a two-dimensional pixelated parallel-plate avalanche counter

CHICO 2 (Compact Heavy Ion COunter), is a large solid-angle, charged-particle detector array developed to provide both θ and Φ angle resolutions matching those of GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array). CHICO 2 was successfully tested at the Argonne National Laboratory where it was fielded as an auxiliary detector with GRETINA for γ-ray spectroscopic studies of nuclei using a 252 Cf spontaneous fission source, stable beams, and radioactive beams from CARIBU. In field tests of the 72,76Ge beams on a 0.5 mg/cm 2 208Pb target at the sub-barrier energy, CHICO 2 provided charged-particle angle resolutions (FWHM) of 1.55° in θ and 2.47° in Φ. This achieves the design goal for both coordinates assuming a beam-spot size (>3 mm) and the target thickness (>0.5 mg/cm 2 ). The combined angular resolution of GRETINA/CHICO 2 resulted in a Doppler-shift corrected energy resolution of 0.60% for 1 MeV coincident de-excitation γ-rays. This is nearly a factor of two improvements in resolution and sensitivity compared to Gammasphere/CHICO. Kinematically-coincident detection of scattered ions by CHICO 2 still maintains the mass resolution (ΔM/M) of ~5% that enhanced isolation of scattered weak beams of interest from scattered contaminant beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The HPS electromagnetic calorimeter

The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon". Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. Finally, the detector is a homogeneous calorimeter, made of 442 lead-tungsten (PbWO$_4$) scintillating crystals, each read-out by an avalanche photodiode coupled to a custom trans-impedance amplifier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulation study of ultra-fast beam bunches split for three orthogonal planes high-energy electron dynamic radiography

Here a compact three orthogonal planes high-energy electron radiography system was proposed. One of the critical technologies, the ultra-fast beam bunches split from the bunch train are studied. The separated bunches could be transported to the three orthogonal planes of the target for dynamic radiography diagnostics. The key elements of the ultra-fast bunches split system are transverse deflecting cavity (TDC) and the twin septum magnet (TSM). The principle of TDC and TSM are briefly introduced. An example of the beam bunches split system for test experiment (40 MeV electron beam) with TDC and TSM is designed and studied by particle-tracking simulation and it confirms this method is valid and feasible. Especially with TSM, a compact three orthogonal planes radiography system can be realized. The evolution of the beam parameters along the beam line from simulation are investigated. The detailed design of the beam split system and beam dynamics simulation study are presented in this paper.

Zhao, Q. T.↗

The beam and detector of the NA62 experiment at CERN

NA62 is a fixed-target experiment at the CERN SPS dedicated to measurements of rare kaon decays. Such measurements, like the branching fraction of the K + → π + ν ν¯ decay, have the potential to bring significant insights into new physics processes when comparison is made with precise theoretical predictions. For this purpose, innovative techniques have been developed, in particular, in the domain of low-mass tracking devices. Detector construction spanned several years from 2009 to 2014. The collaboration started detector commissioning in 2014 and will collect data until the end of 2018. Furthermore, the beam line and detector components are described together with their early performance obtained from 2014 and 2015 data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying Muon Neutrino Charged-Current Interactions in the MicroBooNE Detector

The MicroBooNE experiment is a short-baseline neutrino experiment at the Fermi National Accelerator Laboratory (FNAL) in the US, receiving a highly pure muon neutrino beam from the Booster Neutrino Beam (BNB) and taking data since October 2015. The main physics goal of MicroBooNE is to clarify the nature of the low-energy excess of electron-like events observed by the MiniBooNE Cherenkov detector, which due to its detector technology is unable to resolve whether the observed excess shower-like events are due to electrons or photons. Instead, MicrooBooNE employs cutting-edge liquid argon time projection chamber (LArTPC) technology, which offers excellent spatial and calorimetric resolution, which makes it possible to reconstruct complex neutrino interactions and to efficiently distinguish different final state particle types. This thesis presents a fully-automated event selection of interactions of the types ν μ +Ar → μ - + X and ν μ + Ar → μ - + p + X developed using the Pandora multi-algorithm approach to pattern recognition for LArTPC experiments. The analysis in this work is performed on a subset of the MicroBooNE Run 1 dataset corresponding to 4.52 × 10 19 protons on target acquired by the MicroBooNE detector between February and October 2016. The analysis quantifies the main signal and background interaction channels that produce a reconstructed neutrino interaction with one and two particles in the final state, and quantifies the extent to which different aspects of the Pandora reconstruction affect the selection performance. MicroBooNE is a surface detector, and therefore cosmic-ray tracks are the main observed background. A direction fitting procedure has been implemented in this analysis to formulate directional probabilities, using the Bethe equation and the high-resolution calorimetric information of MicroBooNE, to reduce this cosmic-ray background. This functionality is used to enhance the efficiency of the Pandora cosmic ray tagging logic, and the impact of this procedure on the reconstruction and event selection performance is analysed. The result of this study is two fully-automated selections of ν μ +Ar → μ - + X (57.91% pure) and ν μ + Ar → μ - + p + X (78.30% pure) with efficiencies of 64.35% and 62.65%, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Volume of interest CBCT and tube current modulation for image guidance using dynamic kV collimation

Purpose: The focus of this work is the development of a novel blade collimation system enabling volume of interest (VOI) CBCT with tube current modulation using the kV image guidance source on a linear accelerator. Advantages of the system are assessed, particularly with regard to reduction and localization of dose and improvement of image quality. Methods: A four blade dynamic kV collimator was developed to track a VOI during a CBCT acquisition. The current prototype is capable of tracking an arbitrary volume defined by the treatment planner for subsequent CBCT guidance. During gantry rotation, the collimator tracks the VOI with adjustment of position and dimension. CBCT image quality was investigated as a function of collimator dimension, while maintaining the same dose to the VOI, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Dose distributions were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field CBCT distributions to quantify dose reduction and localization to the target volume. A novel method of optimizing x-ray tube current during CBCT acquisition was developed and assessed with regard to contrast-to-noise ratio (CNR) and imaging dose. Results: Measurements show that the VOI CBCT method using the dynamic blade system yields an increase in contrast-to-noise ratio by a factor of approximately 2.2. Depending upon the anatomical site, dose was reduced to 15%–80% of the full-field CBCT value along the central axis plane and down to less than 1% out of plane. The use of tube current modulation allowed for specification of a desired SNR within projection data. For approximately the same dose to the VOI, CNR was further increased by a factor of 1.2 for modulated VOI CBCT, giving a combined improvement of 2.6 compared to full-field CBCT. Conclusions: The present dynamic blade system provides significant improvements in CNR for the same imaging dose and localization of imaging dose to a predefined volume of interest. The approach is compatible with tube current modulation, allowing optimization of the imaging protocol.

60 APPLIED LIFE SCIENCES↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗