[Data Set] East Fork Poplar Creek Discharge at Kilometer 16.2 Water Year 2017
This data set reports stream discharge and water temperature for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This data set reports stream discharge and water temperature for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream discharge and water temperature for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream water temperature, specific conductance, pH, dissolved oxygen percent saturation and dissolved oxygen concentration for East Fork Poplar Creek at a location approximately 5.4 kilometers upstream from the mouth of the creek.
This data set reports stream water temperature, specific conductance, pH, turbidity, dissolved oxygen percent saturation and dissolved oxygen concentration for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream discharge and water temperature for East Fork Poplar Creek at a location approximately 5.4 kilometers upstream from the mouth of the creek.
This data set reports stream water temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 5.4 kilometers upstream from the mouth of the creek.
This data set reports stream discharge and water temperature for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream water temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 16.2 kilometers upstream from the mouth of the creek.
This data set reports stream discharge and water temperature for East Fork Poplar Creek at a location approximately 5.4 kilometers upstream from the mouth of the creek.
This data set reports stream water temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 5.4 kilometers upstream from the mouth of the creek.
This data set reports stream discharge and water temperature for East Fork Poplar Creek at a location approximately 5.4 kilometers upstream from the mouth of the creek.
This data set reports stream water temperature, specific conductance, pH, dissolved oxygen percent saturation, dissolved oxygen concentration, and turbidity for East Fork Poplar Creek at a location approximately 5.4 kilometers upstream from the mouth of the creek.
Summary of Students and Projects: Sarah Bender: The possible improvement of the Multi-Isotope Process (MIP) Monitor by the addition of Compton suppression is investigated for this study. The Compton continuum from the dominant 661.7 keV Cs-137 fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. A novel Compton suppression system which uses fast, room-temperature materials will be developed using simulation. As opposed to the standard high purity germanium (HPGe) detector suppressed using a thallium-doped sodium iodide (NaI(Tl)) guard detector array, cerium-doped lanthanum bromide (LaBr3) will be used as the primary spectroscopic detector. For Sarah’s Master’s degree, she constructed and validated the unsuppressed detector response of the Pennsylvania State University (PSU)-Compton suppression system. For Sarah’s PhD, she is completing that simulation by including the suppressed operation which will be validated with spent fuel samples. She is also going to use the validation of suppressed operation to predict the detector response of a LaBr3 based Compton suppression system. Richard Clark: Richard Clark completed his study this FY of a new technique known as Intrinsic Dosimetry. Intrinsic Dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide enhanced pathway information regarding the history of the container and its radioactive contents. The latest in a series of experiments designed to validate and demonstrate this newly developed tool are reported. Kenneth Dayman: The MIP Monitor is an online, non-destructive approach to process monitoring in a nuclear fuel reprocessing facility using gamma spectra taken of process streams and multivariate data analysis to detect anomalies in operation. Last year, Mr. Dayman investigated methods to classify spent nuclear fuel according to both reactor type and burn up based on the constituent nuclide activities, which may be used to more accurately calibrate other models in an analysis scheme in order to improve the accuracy and precision of predictions. He is currently writing up his results for publication and has transitioned to another project with Dr. Derrick Haas at PNNL.
This report summarizes the outcome of a research project that comprised the development of a Lyapunov function based remedial action screening tool using real-time data (L-RAS). The L-RAS is an advanced computational tool that is intended to assist system operators in making real-time redispatch decisions to preserve power grid stability. The tool relies on screening contingencies using a homotopy method based on Lyapunov functions to avoid, to the extent possible, the use of time domain simulations. This enables transient stability evaluation at real-time speed without the use of massively parallel computational resources. The project combined the following components. 1. Development of a methodology for contingency screening using a homotopy method based on Lyapunov functions and real-time data. 2. Development of a methodology for recommending remedial actions based on the screening results. 3. Development of a visualization and operator interaction interface. 4. Testing of screening tool, validation of control actions, and demonstration of project outcomes on a representative real system simulated on a Real-Time Digital Simulator (RTDS) cluster. The project was led by Michigan State University (MSU), where the theoretical models including homotopy-based screening, trajectory correction using real-time data, and remedial action were developed and implemented in the form of research-grade software. Los Alamos National Laboratory (LANL) contributed to the development of energy margin sensitivity dynamics, which constituted a part of the remedial action portfolio. Florida State University (FSU) and Southern California Edison (SCE) developed a model of the SCE system that was implemented on FSU's RTDS cluster to simulate real-time data that was streamed over the internet to MSU where the L-RAS tool was executed and remedial actions were communicated back to FSU to execute stabilizing controls on the simulated system. LCG Consulting developed the visualization and operator interaction interface, based on specifications provided by MSU. The project was performed from October 2012 to December 2016, at the end of which the L-RAS tool, as described above, was completed and demonstrated. The project resulted in the following innovations and contributions: (a) the L-RAS software prototype, tested on a simulated system, vetted by utility personnel, and potentially ready for wider testing and commercialization; (b) an RTDS-based test bed that can be used for future research in the field; (c) a suite of breakthrough theoretical contributions to the field of power system stability and control; and (d) a new tool for visualization of power system stability margins. While detailed descriptions of the development and implementation of the various project components have been provided in the quarterly reports, this final report provides an overview of the complete project, and is demonstrated using public domain test systems commonly used in the literature. The SCE system, and demonstrations thereon, are not included in this report due to Critical Energy Infrastructure Information (CEII) restrictions.