Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

The impact of fuel particle size distribution on neutron transport in stochastic media

This paper presents a study of the particle size distribution impact on neutron transport in three-dimensional stochastic media. An eigenvalue problem is simulated in a cylindrical container consisting of fissile fuel particles with five different size distributions: constant, uniform, power, exponential and Gaussian. We construct 15 cases by altering the fissile particle volume packing fraction and its optical thickness, but keeping the mean chord length of the spherical fuel particle the same at different size distributions. The tallied effective multiplication factor (k{sub eff}) and flux distribution along axial and radial directions are compared between different size distributions. At low packing fraction and low optical thickness, the size distribution has a significant impact on radiation transport in stochastic media, which can cause as high as {approx}270 pcm difference in k{sub eff} value and {approx}2.6% relative error difference in peak flux. As the packing fraction and optical thickness increase, the impact gradually dissipates. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using Radiochromic Films to Characterize the Dispersion of ZrO{sub 2} Nano-sized Grain Clusters in Protective Polymer Composites

Radiation dosimetry is commonly used to prevent deterministic radiation effects in high dose medical procedures. Radiochromic films find nowadays widely application in radiotherapy, interventional procedures and CT exams for isodose and maximum skin dose measurements. Moreover the size of the irradiated area and its distribution can be performed through the reading of the individual components in the RGB-spectrum. Particularly, radiochromic film has multiple advantages over alternative dosimeters for low-kV X-rays dosimetry. Concerned to spatial resolution it is far superior to that of ionization chambers and thermoluminescent dosimeters. For high energy photon fields (keV to MeV) the most used radiochromic film commercially available belongs to the EBT Gafchromic{sup R} series. On the other hand, for low energy photon fields in the x-ray range (20 kVp to 200 kVp) the best choice belongs to the XR-QA Gafchromic{sup R} film series. In this work we demonstrate the possibility of generating 2D images of thin polymeric composites films using EBT3 and XR-QA2 Gafchromic{sup R} films exposed to 6 MeV and 40 keV x-ray photons, respectively, using the digital filtering tools of the ImageJ{sup R} free software. In this context, EBT3 films were placed on the surface of a rigid anthropomorphic phantom. Then, they were covered with a thermoplastic mask made of PCL polymer. This setup was then exposed to 2.0 Gy absorbed dose in the Linear Accelerator beam. The EBT3 films were then scanned in the high resolution mode in a commercial scanner and the images subsequently treated with digital filters. It is somehow possible to see the image of the thermoplastic mask in the scanned image. However, in the treated image it is easy to observe the mask arrangement. The unexpected phenomenon here is the EB3 film ability to detect the attenuation of high energy photons by a plastic material, which in turn has a very low mass-energy attenuation coefficient, producing a very clear 2D image. This result is discussed in terms of the high Z halides added to the sensitive layer of EB3 film, once the main components are C (42.3%), H (39.7%) and O (16.0%)1-2. Based on the above results, we have speculated about the abilities of XR-AQ films in the detection of the distribution of nano-sized particles that has high mass-energy attenuation coefficients for low energy x-rays, in polymer composites. In another investigation we tested the ability of XR-QA2 Gafchromic{sup R} films to evaluate the dispersion of ZrO{sub 2} nano-sized grain clusters in protective composites. The P(VDFTrFE)/ ZrO{sub 2} film was sandwiched between two XR-QA2 radiochromic films. In this setup, one radiochromic film is directly exposed to 100 mGy of the x-rays beam and another one measures the attenuated beam. After storage for 24 hours at room temperature under no light conditions, the irradiated radiochromic films were scanned under the same conditions in order to obtain a more reliable result. All films were scanned using the same size ROI in high resolution mode and saved as tagged image file format (TIFF). The untreated scanned image of the XR-AQ2 film directed exposed to the X-ray beam and the correspondent treated image with digital filters are shown. The untreated and treated image of the XR-AQ2 film that was exposed to the attenuated x-ray beam is shown. The image treated with digital filters seems to reproduce the dispersion of ZrO{sub 2} nano-sized grain clusters in the P(VDF-TrFE) copolymer matrix. This result is also discussed in terms of the high Z halides added to the sensitive layer of XR-AQ2 film and compared to the MEV images obtained from the P(VDF-TrFE)/ZrO{sub 2} composites. The results indicate a clear correlation between the 2D radiochromic image and the MEV photography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser size reduction of contaminated Magnox Pond skips - 15166

The Magnox Pond Program Team at Hinkley Point A Power Station have successfully demonstrated the use of an automated Computer Numeric Controlled (CNC) dry milling process to efficiently decontaminate radioactive pond skips that were once used to store and transport Magnox spent fuel assemblies between reactor sites and Sellafield for reprocessing. This decontamination process has ensured ILW skips meet metal melt recycling criteria, and even Out of Scope levels, while at the same time producing dry swarf that is easily disposed of as ILW. However, the dry milling method requires the skips to be size reduced to a very simple flat geometry to simplify the milling operation. Several size reduction techniques (mechanical and thermal) have been evaluated. Based on the advantages of remote handling, high cutting speed, flexibility with complex geometries, reduced secondary waste production and significantly reduced worker exposure, robotically operated fibre delivered laser cutting was chosen. This paper describes the development, installation and operation of an automated laser cutting system commissioned at Hinkley Point A to size reduce contaminated skips in to five flat sections. It was demonstrated that a complete skip can be remotely size reduced in less than 60 minutes. This successful demonstration, coupled with CNC milling, has the potential to save an estimated British Pounds 30 million across the Magnox sites alone, with much higher saving potentials for skips stored at Sellafield, enabling this new size reduction process to meet cost reduction objectives of the UK's Nuclear Decommissioning Authority. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System and method for controlling metal oxide gel particle size

Metal oxide gel particles, may be prepared with a desired particle size, by preparing a low-temperature aqueous metal nitrate solution containing hexamethylene tetramine as a feed solution; and causing the feed solution to flow through a first tube and exit the first tube as a first stream at a first flow rate, so as to contact a high-temperature nonaqueous drive fluid. The drive fluid flows through a second tube at a second flow rate. Shear between the first stream and the drive fluid breaks the first stream into particles of the metal nitrate solution, and decomposition of hexamethylene tetramine converts metal nitrate solution particles into metal oxide gel particles. A metal oxide gel particle size is measured optically, using a sensor device directed at a flow of metal oxide gel particles within the stream of drive fluid. The sensor device measures transmission of light absorbed by either the metal oxide gel particles or the drive fluid, so that transmission of light through the drive fluid changes for a period of time as a metal oxide gel particle passes the optical sensor. If a measured particle size is not about equal to a desired particle size, the particle size may be corrected by adjusting a ratio of the first flow rate to a total flow rate, where the total flow rate is the sum of the first and second flow rates.

Linneen, Nicholas↗

An improved methodology to determine pore size distribution and pore density in the high burnup structure

The formation of the high burnup structure (HBS) on the peripheral region of the light water reactor (LWR) UO{sub 2} fuel pellet is characterized by a steep increase in porosity. The newly formed micron-size intergranular pores trap most of the created fission gas. The study of the pore size distribution and its evolution with burnup is fundamental to estimate the fission gas pressure in the pores and can influence the burst release in accidental conditions. Quantitative image analysis is usually employed to quantify the pore size-distribution. It is determined mainly in two dimension (2D) using a histogram. Few attempts have been made in the past to derive also three-dimensional (3D) pore size-distribution employing the Schwartz-Saltykov (ScSa) method. In this work, we determine experimentally the pore size-distribution in the HBS and apply a new procedure to determine the distribution, both in 2D and 3D. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimation of LOCA break size using cascaded support vector regression - 334

A failure of emergency core cooling system (ECCS) during a certain small break loss of coolant accident (SBLOCA) can cause a severe core uncovery and fuel failure. The safety injection systems (SISs) might not function properly in case of a SBLOCA, due to the slight change of pressure in the pipes. Early trend of the major parameters has to be observed and the accurate information has to be given to the nuclear power plant (NPP) operators by precisely identifying the break size to effectively manage accidents. In this study, the objective is to provide to operators the information on the break size in a short time by considering the accident situations such as hot-leg LOCA, cold-leg LOCA, steam generator tube rupture (SGTR). A cascaded support vector regression (CSVR) is used in order to estimate the break size. The simulation data set was obtained from the optimized power plant reactor 1000 (OPR1000) using modular accident analysis program (MAAP) code. And genetic algorithm (GA) was used to select the input variables of the CSVR model and optimize its parameters. As a result of this study, the CSVR model estimate very well the break size of LOCAs. If the operators can predict the break size in the LOCA, they can response quickly and properly to LOCA circumstances to prevent the core uncovery and fuel failure. Also, it will be possible to more efficiently manage beyond design basis accidents. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Particle Size on Raman Signal Strength of Silicate Minerals

Understanding the effects of particle size is necessary for quantifying minerals in mixtures using Raman spectroscopy. Raman signal intensity is evaluated using six common silicate minerals (two olivines, two pyroxenes, and two feldspars) at 10 particle size ranges. For olivines and feldspars, the highest peak intensities are observed in samples with 38–63 and 63–106 μm particle sizes. There is no such consistent trend for the pyroxene samples, although the overall low signal strength complicates those measurements. In conclusion, Raman spectra of samples with varying particle sizes appear to be influenced by two competing effects: scattering from particle boundaries and effective sampling volume.

58 GEOSCIENCES↗

Mobility size and mass of nascent soot particles in a benchmark premixed ethylene flame

The burner stabilized stagnation flame technique coupled with micro-orifice probe sampling and mobility sizing has evolved into a useful tool for examining the evolution of the particle size distribution of nascent soot in laminar premixed flames. Several key aspects of this technique are examined through a multi-university collaborative study that involves both experimental measurement and computational modeling. Key issues examined include (a) data reproducibility and facility effects using four burners of different sizes and makers over three different facilities, (b) the mobility diameter and particle mass relationship, and (c) the degree to which the finite orifice flow rate affects the validity of the boundary condition in a pseudo one dimensional stagnation flow flame formulation. The results indicate that different burners across facilities yield nearly identical results after special attention is paid to a range of experimental details, including a proper selection of the sample dilution ratio and quantification of the experimental flame boundary conditions. The mobility size and mass relationship probed by tandem mass and mobility measurement shows that nascent soot with mobility diameter as small as 15 nm can deviate drastically from the spherical shape. Various non-spherical morphology models using a mass density value of 1.5 g/cm 3 can reconcile this discrepancy in nascent soot mass. Lastly, two-dimensional axisymmetric simulations of the experimental flame with and without the sample orifice flow reveal several problems of the pseudo one-dimensional stagnation flow flame approximation. The effect of the orifice flow on the flame and soot sampled, although small, is not negligible. Particular suggestions are provided as to how to treat the non-ideality of the experimental setup in experiment and model comparisons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic nanoparticles for power absorption: Optimizing size, shape and magnetic properties

We present a study on the magnetic properties of naked and silica-coated Fe{sub 3}O{sub 4} nanoparticles with sizes between 5 and 110 nm. Their efficiency as heating agents was assessed through specific power absorption (SPA) measurements as a function of particle size and shape. The results show a strong dependence of the SPA with the particle size, with a maximum around 30 nm, as expected for a Neel relaxation mechanism in single-domain particles. The SiO{sub 2} shell thickness was found to play an important role in the SPA mechanism by hindering the heat outflow, thus decreasing the heating efficiency. It is concluded that a compromise between good heating efficiency and surface functionality for biomedical purposes can be attained by making the SiO{sub 2} functional coating as thin as possible. - Graphical Abstract: The magnetic properties of Fe{sub 3}O{sub 4} nanoparticles from 5 to 110 nm are presented, and their efficiency as heating agents discussed as a function of particle size, shape and surface functionalization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cation distribution and particle size effect on Raman spectrum of CoFe{sub 2}O{sub 4}

Moessbauer and Raman spectroscopic studies were carried out on CoFe{sub 2}O{sub 4} particles synthesized with size ranging from 6 to 500 nm (bulk). Cation distribution studies were carried out on the high temperature and room temperature phases of the microcrystalline CoFe{sub 2}O{sub 4} by Moessbauer and Raman spectroscopic methods. The high temperature phase of CoFe{sub 2}O{sub 4} showed a decreased inversion parameter of 0.69 as compared to the value of the room temperature phase of 0.95, indicating that the structure gradually transforms towards a normal spinel. Corresponding Raman spectra for these two phases of CoFe{sub 2}O{sub 4} showed a change in relative peak intensity of the vibrational mode at 695 cm{sup -1}(A{sub 1g}(1)) to 624 cm{sup -1} (A{sub 1g}(2)). The relative peak intensity ratio, I{sub v} between the A{sub 1g}(1) and A{sub 1g}(2) vibrational mode was decreasing with lowering of inversion parameter of the CoFe{sub 2}O{sub 4} spinel system. A variation of laser power on the sample surface was reflected in the cation distribution in ferrite phase. Superparamagnetic, single domain CoFe{sub 2}O{sub 4} particles (6 nm) showed a 20 cm{sup -1} red shift and broadening of phonon modes when compared to the macro-crystalline CoFe{sub 2}O{sub 4} (500 nm). Variation of Raman shift with particle size was studied by considering the bond polarization model. Raman spectroscopic studies clearly indicate the variation in the cation distribution in nano-sized particles and distribution tending to a normal spinel structural configuration. -- Graphical abstract: Variation of Raman shift difference ({Delta}{omega}) with size. Display Omitted

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Size selected synthesis of CoFe{sub 2}O{sub 4} nanoparticles prepared in a chitosan matrix

In this paper we report the synthesis and magnetic properties of CoFe{sub 2}O{sub 4} nanoparticles. The nanoparticles with sizes ranging from 6 to 20 nm were prepared in a chitosan matrix. Size selection was achieved by introducing a nonionic surfactant Tween-X, where X={l_brace}20, 60, 80, and 85{r_brace}. Aqueous dispersions of Tween-X show micelles with increasing hydrodynamic sizes as X increases. Moessbauer spectroscopy measurements at 300 K show superparamagnetic behavior for the small particles, changing gradually to a blocked magnetic regime as the particle size increases. Magnetization measurements at 300 K show increasing values for the ratio M{sub r}/M{sub Hmax} and coercive fields (H{sub c}).

36 MATERIALS SCIENCE↗

Electrical Characteristics CuFe{sub 2}O{sub 4} Thick Film Ceramics Made with Different Screen Size Utilizing Fe{sub 2}O{sub 3} Nanopowder Derived from Yarosite for NTC Thermistor

Fabrication of CuFe{sub 2}O{sub 4} thick film ceramics utilizing Fe{sub 2}O{sub 3} derived from yarosite using screen printing technique for NTC thermistor has been carried out. Effect of thickness variation due to different size of screen (screen 225; 300 and 375 mesh) has been studied. X-ray diffraction analyses (XRD) was done to know crystal structure and phases formation. SEM analyses was carried out to know microstructure of the films. Electrical properties characterization was done through measurement of electrical resistance at various temperatures (room temperature to 100 deg. C). The XRD data showed that the films crystalize in tetragonal spinel. The SEM images showed that the screen with the smaller of the hole size, made the grain size was bigger. Electrical data showed that the larger the screen different size thickness variation (mesh), the larger the resistance, thermistor constant and sensitivity. From the electrical characteristics data, it was known that the electrical characteristics of the CuFe{sub 2}O{sub 4} thick film ceramics followed the NTC characteristic. The value of B and R{sub RT} of the produced CuFe{sub 2}O{sub 4} ceramics namely B = 3241-3484 K and R{sub RT} = 25.6-87.0 M Ohm, fitted market requirement.

36 MATERIALS SCIENCE↗

CACTI: Best Estimate Aerosol Size Distribution by airborne measurements

These data were collected during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI; https://www.arm.gov/research/campaigns/amf2018cacti ) field campaign in the Sierras de Córdoba mountain range of north-central Argentina as part of ARM Aerial Facility (AAF) deployment. The ARM Aerial Facility Gulfstream-1 was operated from Las Higueras Airport (IATA: RCU, ICAO: SAOC), Río Cuarto, Córdoba, Argentina, for the Intensive Observation Period (IOP) from Nov. 1 through Dec. 15, 2018. The G-1 aircraft performed 22 research flights over the first ARM Mobile Facility (AMF1) location in the Sierras de Córdoba mountain range to measure atmospheric state and turbulence, cloud water content and droplet size distributions, aerosol precursor gases, aerosol chemical composition and size distributions. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 5 sensors; three aerosol spectrometers: Scanning Mobility Particle Sizer (SMPS), Ultra-High Sensitivity Aerosol Spectrometer (UHSAS), and Passive Cavity Aerosol Spectrometer (PCASP); and two cloud probes: Cloud Aerosol Spectrometer (CAS) and Fast Cloud Droplet Probe (FCDP). The SMPS data were interpolated to 1 second from “native” time resolution of about 64 second to match all other probes.

54 ENVIRONMENTAL SCIENCES↗

Simplified Optimum Sizing and Cost Analysis for Compact heat Exchanger in VHTR

In this study, the optimum size of the compact heat exchanger has been developed based on its weight and pumping power for the reference design of 600 MWt very high temperature gas-cooled reactor (VHTR) system. Alloy 617 was selected as a construction material. The optimum size and a number of configurations for the reference design of the VHTR with an intermediate heat exchanger (IHX) were investigated and our initial calculations indicated that it has an unrealistically too large aspect ratio of the length and height due to its small-sized channels, which might cause manifolding problems and a large number of parallel modules with high thermal stress. The flow area and channel diameter were then adjusted to achieve a smaller aspect ratio in this paper. Achievement of this aspect ratio resulted in higher cost, but the cost increase was less than would have occurred by simply reducing the flow area by itself. The appropriate channel diameter is estimated to be less than 5.00 mm for the reference system. The effect of channel waviness enhanced the compactness and heat transfer performance, but unfavorably increased the aspect ratio. Therefore, the waviness should be carefully determined based on performance and economics. In this study, the waviness of the IHX is recommended to be selected between 1.0 and 2.5. Calculations show that reducing the duty dramatically decreases the aspect ratio, indicating that the compact heat exchanger is easy to be optimally designed for low duty, but many modules are required for high duty operation proportional to the operating power. Finally, the effect of working fluids was investigated, and it reveals that using carbon dioxide instead of helium in the secondary side reduces the size and cost by about 20% due to the lower pumping power in spite of its lower heat transfer capability by a factor of 4.

99 GENERAL AND MISCELLANEOUS↗

Factors influencing pregnancy, litter size, and reproductive parameters of invasive wild pigs

Abstract Reproduction is the most energetically expensive life stage with the demands of productivity representing a balance between physiological requirements and environmental conditions. Wild pigs ( Sus scrofa ) throughout most of North America are genetic hybrids of feral domestic pigs and wild boar and have the highest reproductive potential of any wild ungulate. The phenology of reproduction, extent of multiple reproductive events per year, how individual and extrinsic factors contribute to variability in productivity, and impact of genetic lineage on these parameters is not well understood in wild pigs. We quantified reproductive parameters in wild pigs relative to a suite of individual and environmental attributes across seasons and multiple years in South Carolina, USA, from March 2017 and May 2020. We hypothesized that individual attributes (mass, age class, number of teats, rump fat, relative genetic association to wild boar vs. domestic pigs) and extrinsic factors (mast availability) would influence probability of pregnancy and fetal litter size. Wild pigs produced offspring throughout all months with peaks in conception corresponding to a seasonal pulse in food availability. The likelihood of pregnancy was influenced by female mass and nutritional condition and was greatest during years with abundant resources. Similarly, litter size increased with female mass and age, implying larger and older females represent the most important group for population recruitment. In evaluating the relationship between reproductive output and ancestral associations to domestic pigs versus wild boar, the proportion of wild boar ancestry was not an important influence on productivity in our population. We determined juveniles reach a physiological threshold of sexual maturity at approximately 30 kg. Average litter size was comparable to other populations, and wild pigs maintain an average fetal litter size of 5.43 offspring despite 13.6% embryonic mortality. A thorough understanding of biotic and extrinsic factors influencing reproduction are important for realistic population models, which are necessary for identifying areas to focus management needs and implementation.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Particle Size Standard NIST 1019b with SynchrotronX-ray Microtomography and Digital Data Extraction

We show that synchrotron x-ray microtomography ({mu}CT) followed by digital data extraction can be used to examine the size distribution and particle morphologies of the polydisperse (750 to 2450 {micro}m diameter) particle size standard NIST 1019b. Our size distribution results are within errors of certified values with data collected at 19.5 {micro}m/voxel. One of the advantages of using {mu}CT to investigate the particles examined here is that the morphology of the glass beads can be directly examined. We use the shape metrics aspect ratio and sphericity to examine of individual standard beads morphologies as a function of spherical equivalent diameters. We find that the majority of standard beads possess near-spherical aspect ratios and sphericities, but deviations are present at the lower end of the size range. The majority (> 98%) of particles also possess an equant form when examined using a common measure of equidimensionality. Although the NIST 1019b standard consists of loose particles, we point out that an advantage of {mu}CT is that coherent materials comprised of particles can be examined without disaggregation.

36 MATERIALS SCIENCE↗

Impact of Different Vein Catheter Sizes for Mechanical Power Injection in CT: In Vitro Evaluation with Use of a Circulation Phantom

The purpose of this study was to evaluate the influence of different peripheral vein catheter sizes on the injection pressure, flow rate, injection duration, and intravascular contrast enhancement. A flow phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used. High-iodine-concentration contrast medium (370 mg iodine/ml; Ultravist 370) was administered in the venous compartment through peripheral vein catheters of different sizes (14, 16, 18, 20, 22, and 24 G) using a double-head power injector with a pressure limit of 325 psi. The flow rate was set to 5 ml/s, with a total iodine load of 36 g for all protocols. Serial CT scans at the level of the pulmonary artery and the ascending and the descending aorta replica were obtained. The true injection flow rate, injection pressure, injection duration, true contrast material volume, and pressure in the phantom during and after injection were continuously monitored. Time enhancement curves were computed and both pulmonary and aortic peak time and peak enhancement were determined. Using peripheral vein catheters with sizes of 14-20 G, flow rates of approximately 5 ml/s were obtained. During injection through a 22-G catheter the pressure limit was reached and the flow rate was decreased, with a consecutive decreased pulmonary and aortic contrast enhancement compared to the 14- to 20-G catheters. Injection through a 24-G peripheral vein catheter was not possible because of disconnection of the canula due to the high flow rate and pressure. In summary, intravenous catheters with sizes of 14-20 G are suitable for CT angiography using an injection protocol with a high flow rate and a high-iodine-concentration contrast medium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gelatin Microspheres: Correlation between Embolic Effect/Degradability and Cross-linkage/Particle Size

PurposeTo evaluate the embolic effect and degradability of gelatin microspheres (GMS) using various degrees of cross-linkage and particle sizes in rabbit renal artery embolization.MethodsFour types of GMS were used, as follows: 2 types of cross-linkage and 2 types of particle size. Twenty-four rabbits (6 in each group) were used for the renal artery embolization. Renal angiography was performed before and after embolization of right renal artery. Follow-up renal angiography was performed 2 days (n = 2), 5 days (n = 2), and 15 days (n = 2) after embolization in each group, and then kidneys were removed for histopathological evaluation. Vascular areas of the angiography were measured by Image J software, and the reperfusion rate was calculated. In renal specimens, residual GMS were checked and the degree of degradation was classified according to a 4-point scale.ResultsThe mean amounts of large- and small-particle-size GMS injected were 15.0 and 34.3 mg, respectively. Tissue necrosis was confirmed in each group; however, no difference was observed among groups. Renal reperfusion was observed more with small GMS than with large GMS. Renal reperfusion was also observed more with low cross-linked GMS than with high cross-linked GMS. In histopathological specimens, large GMS were confirmed in lobar artery, and small GMS were confirmed in lobular artery. Low cross-linked GMS completely degraded 15 days after embolization. In contrast, high cross-linked GMS were persistent 15 days after embolization.ConclusionDegree of cross-linkage and particle size affected degradability and reperfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗