Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Sensors closeness test based on an improved [0, 1] bounded Mahalanobis distance Δ{sup 2}

Mahalanobis distance Δ{sup 2} values are commonly in the range of 0 to +∞ where higher values represent greater distance between class means or points. The increase in Mahalanobis distance is unbounded as the distance multiply. To certain extend, the unbounded distance values pose difficulties in the evaluation and decision for instance in the sensors closeness test. This paper proposes an approach to [0, 1] bounded Mahalanobis distance Δ{sup 2} that enable researcher to easily perform sensors closeness test. The experimental data of four different types of rice based on three different electronic nose sensors namely InSniff, PEN3, and Cyranose320 were analyzed and sensor closeness test seems successfully performed within the [0, 1] bound.

42 ENGINEERING↗

A step-wise steerable source of illumination for low-noise “Violin-Mode” shadow sensors, intended for use in interferometric gravitational wave detectors

A steerable low-noise source of illumination is described for shadow-sensors having a displacement sensitivity of ∼100 pm (rms)/√Hz, at 500 Hz, over a measuring span of at least ±0.5 mm. These sensors were designed to detect lateral “Violin-Mode” resonances in the highly tensioned fused-silica suspension fibres of the test-masses/mirrors for the Advanced Laser Interferometer Gravitational Wave Observatory gravitational wave detectors. The shadow sensors—one intended for each of the four fibres in a suspension—comprised a source of Near InfraRed (NIR) radiation (emitter) and a differential shadow-displacement sensor (detector), these bracketing the fibre under test. The suspension fibres themselves were approximately 600 mm long by 0.4 mm in diameter, and when illuminated from the side, they cast narrow, vertical, shadows onto their respective detectors—these being located at an effective distance of 50 fibre diameters behind the axes of the fibres themselves. The emitter described here was designed to compensate for a significant degree of mechanical drift or creep over time in the mean position of its suspension fibre. This was achieved by employing five adjacent columns of 8 × miniature NIR LEDs (Light Emitting Diodes, λ = 890 nm), with one column being activated at a time. When used in conjunction with a “reverse Galilean” telescope, the LED sources allowed the collimated beam from the emitter to be steered azimuthally in fine angular increments (0.65°), causing the fibre’s shadow to move laterally, in a step-wise manner, across the plane of its facing detector. Each step in shadow position was approximately 0.23 mm in size, and this allowed the fibre’s shadow to be re-centred, so as to bridge once again both elements of its photodiode detector—even if the fibre was off-centred by as much as ±0.5 mm. Re-centring allowed Violin-Mode vibrations of the fibre to be sensed once again as differential AC photocurrents, these flowing in anti-phase in the two elements of the “split-photodiode” detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless energizing system for an automated implantable sensor

The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A data acquisition system for HV-CMOS sensor research and development in the upgrade of ATLAS experiment

In the High Luminosity LHC (HL-LHC) upgrade of ATLAS experiment in 2026, the new inner tracker detector will be installed. As a promising candidate for the outer layer of the inner tracker detector, the High Voltage CMOS (HV-CMOS) pixel sensors are being investigated by the ATLAS collaboration. A Front-End LInk eXchange (FELIX) based Data Acquisition (DAQ) system is developed for the R&D of the HV-CMOS sensors. A FELIX card with PCIe interface in the back-end is used to control, monitor, calibrate and read out the front-end electronics. In the front-end, a Xilinx evaluation board ZC706 works as the interface between the back- end and custom boards with HV-CMOS sensors and the readout ASIC. In conclusion, the DAQ system was successfully deployed for the testbeam experiment at CERN. Design of the DAQ system, the tuning of sensors and testbeam results will be described in details.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic field sensors for detection of trapped flux in superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are fundamental building block of modern particle accelerators. They operate at liquid helium temperatures 2-4 K to achieve very high quality factors 1e10-1e11. Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors and the fundamental components of such diagnostic tool are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors and flux-gate magnetometers with respect to their sensitivity and capability to detect localized, low magnetic flux amplitudes, of the order of few tens of magnetic flux quantum at liquid helium temperature. Although Hall probes have the lowest magnetic field sensitivity (~96$ nV$/microT at 2 K), their physical dimensions are such that they have the ability to detect the lowest number of trapped vortices among the three type of sensors. Hall probes and anisotropic magnetoresistive sensors have been selected to be used in a setup to map regions of trapped flux on the surface of a single-cell SRF cavity.

47 OTHER INSTRUMENTATION↗

Sublimation temperature sensor for temperature locale

The sublimation temperature sensor (or “sublime sensor”) provides a continuum of measurement locations in which certain maximum temperatures are achieved during a heat up/cool down cycle. A predetermined material is encapsulated within a vacuum-sealed, non-volatile long tube (i.e., both ends capped and L$\gg$ D). This assembly is then inserted and centered into a heated zone, such as a furnace, exhaust pipe, or reactor. As the temperature increases, the material will sublimate (i.e., a process of having both the solid and gaseous states of matter simultaneously present) and will begin to fill the void - moving outward in both directions toward the ends of the tube. Once beyond the elevated temperatures, the gas will de-sublimate (i.e., deposition) onto the inner wall of the tube. The desired result of the sensor is the ring of material that develops over a relatively short period of time. This material deposit can be equated with temperature at an exact location. There is no need to interpolate and/or extrapolate for the desired measurement. Accuracy has been recorded for temperature locations on the range of ±2 mm over a 1 m span. Likewise, the precision of the measurement is ±0.2% the overall sensor domain. Furthermore, individual tubes with unique materials and pressures can be bundled together to provide a complete temperature profile of the heated zone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High throughput, spatially resolved thermal properties measurement using attachable and reusable 3ω sensors

The 3ω method is a well-established thermal technique used to measure the thermal conductivity of materials and the thermal resistance of interfaces. It has significant advantages over other steady state and transient thermal techniques in its ability to provide spatially resolved thermal property measurements over a wide range of thermal conductivity. Despite its advantages, it has been restricted to lab-scale use because of the difficulty involved in sample preparation and sensor fabrication and is limited to non-metallic substrates. High-throughput 3ω measurements with reusable sensors have not been realized yet. In this work, we demonstrate a method of applying reusable 3ω sensors fabricated on flexible polyimide films to measure bulk and spatially resolved thermal properties. Here, we establish the limits of thermal conductivity measurement with the method to be 1 to 200 W/mK, and within the measurement limit, we verify the method by comparing the measured thermal conductivities of standard samples with established values. From the 3ω measurements, we also determine the thermal resistance of an interlayer of thermal grease as a function of pressure and compare it against the resistance calculated from direct thickness measurements to demonstrate the ability of this method to provide spatially resolved subsurface information. The technique presented is general and applicable to both metallic and non-metallic substrates, providing a method for high-throughput 3ω measurements with reusable sensors and without considerable sample preparation.

47 OTHER INSTRUMENTATION↗

Holographic sensors for diagnostics of solution components

The properties of holographic sensors of two types are studied. The sensors are based on a three-dimensional polymer-network matrix of copolymers of acrylamide, acrylic acid (which are sensitive to the medium acidity and bivalent metal ions) and aminophenylboronic acid (sensitive to glucose). It is found that a change in the ionic composition of a solution results in changes in the distance between layers and in the diffraction efficiency of holograms. Variations in the shape of spectral lines, which are attributed to the inhomogeneity of a sensitive layer, and nonmonotonic changes in the emulsion thickness and diffraction efficiency were observed during transient processes. The composition of the components of a hydrogel medium is selected for systems which can be used as a base for glucose sensors with the mean holographic response in the region of physiological glucose concentration in model solutions achieving 40 nm/(mmol L{sup -1}). It is shown that the developed holographic sensors can be used for the visual and instrumental determination of the medium acidity, alcohol content, ionic strength, bivalent metal salts and the quality of water, in particular, for drinking. (laser applications and other topics in quantum electronics)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theorem of comparative sensitivity of fibre sensors

We report an analysis of sensitivity of fibre sensors of physical quantities based on different types of interferometers. We formulate and prove the following theorem: under the time-dependent external physical perturbations at nonzero frequencies (i.e., except the static and low-frequency ones) on the sensitive arms of an interferometer in the form of multiturn elements (coils), there exist such lengths L of the measuring arms of the fibre interferometers at which the sensitivity of sensors based on the Sagnac fibre interferometers can be comparable with the sensitivity of sensors based on Michelson, Mach – Zehnder, or Fabry – Perot fibre interferometers, as well as exceed it under similar other conditions (similar-type perturbations, similar arm lengths and single-mode fibre types). The consequences that follow from the theorem, important for practical implementation of arrays of fibre sensors for measurement purposes and the devices with stable metrological properties, are discussed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature evolution of interferometer visibility in a small radius fibre coil current sensor

We have experimentally demonstrated periodic oscillations of interferometer visibility in a current sensor in response to changes in the temperature of a small-radius spun fibre sensing coil. The observed effect has been shown to depend on the magnitude of the bend-induced linear birefringence in the spun fibre in the magnetically sensitive coil and the temperature behaviour of the built-in linear birefringence in the fibre. Using a model that considers a helical structure of the built-in linear birefringence axes in spun fibre, we have shown that the above factors result in periodic oscillations of the ellipticity of polarised light at the ends of the sensing coil and that this underlies the temperature oscillations of interferometer visibility in the current sensor. The effect may cause errors in the response of a fibre-optic current sensor with a small sensing coil. (fibre-optic sensors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Laboratory and testbeam results for thin and epitaxial planar sensors for HL-LHC

The High-Luminosity LHC (HL-LHC) upgrade of the CMS pixel detector will require the development of novel pixel sensors which can withstand the increase in instantaneous luminosity to L = 5 × 10 34 cm –2 s –1 and collect ~ 3000fb –1 of data. The innermost layer of the pixel detector will be exposed to doses of about 10 16 n eq / cm 2 . Hence, new pixel sensors with improved radiation hardness need to be investigated. A variety of silicon materials (Float-zone, Magnetic Czochralski and Epitaxially grown silicon), with thicknesses from 50 μm to 320 μm in p-type and n-type substrates have been fabricated using single-sided processing. The effect of reducing the sensor active thickness to improve radiation hardness by using various techniques (deep diffusion, wafer thinning, or growing epitaxial silicon on a handle wafer) has been studied. Furthermore, the results for electrical characterization, charge collection efficiency, and position resolution of various n-on-p pixel sensors with different substrates and different pixel geometries (different bias dot gaps and pixel implant sizes) will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full-scale hot cell test of an acoustic sensor dedicated to measurement of the internal gas pressure and composition of a LWR nuclear fuel rod

A full-scale hot cell test of the internal gas pressure and composition measurement by an acoustic sensor was carried on successfully between 2008 and 2010 on irradiated fuel rods in the LECA-STAR facility at Cadarache Centre. The acoustic sensor has been specially designed in order to provide a nondestructive technique to easily carry out the measurement of the internal gas pressure and gas composition of a LWR nuclear fuel rod. This sensor has been achieved in 2007 and is now covered by an international patent. The first positive result, concerning the device behaviour, is that the sensor-operating characteristics have not been altered by a two-year exposure in the hot cell ambient. We performed the gas characterisation contained in irradiated fuel rods. The acoustic method accuracy is now {+-}5 bars on the pressure measurement result and {+-}0.3% on the evaluated gas composition. The results of the acoustic method were compared to puncture results. Another significant conclusion is that the efficiency of the acoustic method is not altered by the irradiation time, and possible modification of the cladding properties. These results make it possible to demonstrate the feasibility of the technique on irradiated fuel rods. The transducer and the associated methodology are now operational. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An innovative acoustic sensor for first in-pile fission gas release determination - REMORA 3 experiment

A fuel rod has been instrumented with a new design of an acoustic resonator used to measure in a non destructive way the internal rod plenum gas mixture composition. This ultrasonic sensor has demonstrated its ability to operate in pile during REMORA 3 irradiation experiment carried out in the OSIRIS Material Testing Reactor (CEA Saclay, France). Due to very severe experimental conditions such as temperature rising up to 150 deg.C and especially, high thermal fluence level up to 3.5 10{sup 19} n.cm{sup 2}, the initial sensor gas speed of sound efficiency measurement was strongly reduced due to the irradiation effects on the piezo-ceramic properties. Nevertheless, by adding a differential signal processing method to the initial data analysis procedure validated before irradiation, the gas resonance peaks were successfully extracted from the output signal. From these data, the molar fractions variations of helium and fission gas were measured from an adapted Virial state equation. Thus, with this sensor, the kinetics of gas release inside fuel rods could be deduced from the in-pile measurements and specific calculations. These data will also give information about nuclear reaction effect on piezo-ceramics sensor under high neutron and gamma flux. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Harmonics Interferometric Doppler Sensor With a Neon Lamp Detector

A cost-effective harmonic interferometric Doppler sensor has been developed to obtain both amplitude and phase of the micro-Doppler signatures of moving objects. A phase chopper is used to generate the harmonics of the interferometry signal. For cost-effectiveness, a Gunn diode source is used for signal generation and a neon lamp is employed as a broadband detector. An advanced signal processing algorithm has been developed to extract both amplitude and phase Doppler signatures. A prototype has been built to demonstrate the effectiveness of the harmonic interferometric Doppler sensor at 35 GHz, with Doppler objects such as human hand and metal objects. In addition, the broadband detection capability of the neon lamp allows the Doppler sensor to work up to the millimeter-wave regime and potentially beyond the terahertz (THz) wave regime. Due to the ruggedness of the neon lamp detector, it is expected that the Doppler sensor has important applications of sensing and wireless communication in harsh environment such as high-temperature, high-power and radioactive conditions.

Doppler sensor↗

Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis

This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. Here, the manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.

47 OTHER INSTRUMENTATION↗

Embedded Fiber Bragg Grating (FBG) Sensors Fabricated by Ultrasonic Additive Manufacturing for High-Frequency Dynamic Strain Measurements

This article demonstrates high-frequency dynamic strain measurements using fiber Bragg grating (FBG) sensors embedded in metal parts. Using an ultrasonic additive manufacturing (UAM) process, FBGs inscribed in polyimide coated optical fibers were embedded in aluminum parts. An electromagnetic shaker was used to exert dynamic events on the embedded FBG sensors with frequencies from 1 to 10 kHz. The high-speed interrogation of FBG sensors was accomplished using a tunable vertical-cavity surface-emitting laser (VCSEL) and a high-speed interrogation system sampling at 120 kHz. The strain response measured by the FBG sensors was compared with real-time measurements using a laser velocimeter. A finite-element analysis (FEA) was performed to simulate responses to both static strain and high-frequency dynamic strain. In conclusion, results show that strains as small as 2.5$με$ can be resolved at frequencies up to 10 kHz.

36 MATERIALS SCIENCE↗

Resilient Reinforcement in Secure State Estimation against Sensor Attacks with a priori Information

This paper deals with the state estimation problem in the presence of malicious sensor attacks. Unlike the existing work, in this paper, we address the problem with a priori information of the state to be estimated. Specifically, we address three prior knowledge: the sparsity information, (alpha, n_0)-sparsity information, and side information, and in each scenario, we show that the state can be reconstructed even if more sensors are compromised. This implies that the prior information reinforces the system resilience against sensor attacks. Then, an estimator under sensor attacks considering the information is developed and, under a certain condition, the estimator can be relaxed into a tractable convex optimization problem. Further, we extend this analysis to systems in presence of measurement noises, and it is shown that the prior information reduces the state-estimation error caused by the noise. Here, the numerical simulations in a diffusion process finally illustrate the reinforcement and error-reduction results with the information.

24 POWER TRANSMISSION AND DISTRIBUTION↗