Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scintillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, assembly and operation of a Cosmic Ray Tagger based on scintillators and SiPMs

The Mu2e experiment at Fermilab aims to search for the SM forbidden μ – → e – conversion in Al muonic atoms. The signal signature consists of 104.96 MeV electrons, identified by a straw-tube tracker and a crystal calorimeter, made of two annular disks. Here, in order to calibrate the calorimeter disks with minimum ionizing particles (MIP) before the installation, we have realized a Cosmic Ray Tagger (CRT) at Laboratori Nazionali di Frascati (LNF) of INFN. The CRT consists of two planes of eight 2.5 x 1.5 x 160 cm 3 plastic scintillator (EJ-200) bars, coupled to SiPMs on both edges, so as to estimate longitudinal hit positions from time differences. 3D MIP tracking is achieved by reconstructing hit positions in the two planes, placed above and below the disks, and allows to calibrate the energy response, to align the time offsets, and to study the detector performances dependence along the crystals axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to load tellurium in liquid scintillator for the study of neutrinoless double beta decay

Herein, a method has been developed to load tellurium into liquid scintillator so as to permit searches for neutrinoless double beta decay with high sensitivity. The approach involves the synthesis of an oil-soluble tellurium compound from telluric acid and an organic diol. The process utilises distillable chemicals that can be safely handled underground and affords low radioactive backgrounds, low optical absorption and high light yields at loading levels of at least several percent Te by weight.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of charge state distributions using a scintillation screen

Absolute cross sections measured using electromagnetic devices to separate and detect heavy recoiling ions need to be corrected for charge state fractions. Accurate prediction of charge state distributions using theoretical models is not always a possibility, especially in energy and mass regions where data is sparse. As such, it is often necessary to measure charge state fractions directly. In this paper we present a novel method of using a scintillation screen along with a CMOS camera to image the charge dispersed beam after a set of magnetic dipoles. A measurement of the charge state distribution for 88 Sr passing through a natural carbon foil is performed. Using a Bayesian model to extract statistically meaningful uncertainties from these images, we find agreement between the new method and a more traditional method using Faraday cups. Additional future work is need to better understand systematic uncertainties. Our technique offers a viable method to measure charge state distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Experimental validation of scintillator detector response to correlated neutrons with MCNP and associated packages

Time, energy, and angle correlated neutrons are emitted in nuclear fission. New, physics-based fission event generators that capture these correlations have been incorporated into MCNP6.2 because correlations can impact nuclear non-proliferation and safeguards systems response. DRiFT is a detector response code that takes MCNP outputs and reproduces laboratory analogous detector quantities. Previous work has compared DRiFT to single detector experiment data and has discussed recent updates to DRiFT specific to correlated fission experiments. In this work, we demonstrate a validation of recent updates to DRiFT for organic scintillator response in correlated fission neutron experiments using a 252Cf source. Furthermore, outputs from MCNP with the FREYA fission event generator were post-processed with DRiFT and compared to experiment data. Simulation and experiment results are in reasonably good agreement for multiple correlated neutron quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal structure, electronic structure, temperature-dependent optical and scintillation properties of CsCe 2 Br 7

CsCe 2 Br 7 is a self-activated inorganic scintillator that shows promising performance, but the understanding of the important structure-property relationships is lacking. In this work, we conduct a comprehensive study on CCsCe 2 Br 7 . The crystal structure of CsCe 2 Br 7 is refined using single crystal X-ray study for the first time. It crystallizes into the orthorhombic crystal system with Pmnb space group. Its electronic structure is revealed by Density Functional Theory (DFT) calculations. Two cerium emission centers are identified and the energy barriers related to the thermal quenching to 4f ground states of Ce 3+ for these two Ce centers are evaluated. CsCe 2 Br 7 single crystal has better light yield and energy resolution than CsCe 2 Cl 7 , but with an additional slow decay component of 1.7 s. The existence of a deep trap with a depth of 0.9 eV in CsCe 2 Cl 7 contributes to its higher afterglow level in comparison to that of CsCe 2 Br 7 . The most possible point defects in CsCe 2 Cl 7 and CsCe 2 Br 7 are proposed by considering the vapour pressure in the growth atmosphere upon melting point.

36 MATERIALS SCIENCE↗

Near midplane scintillator-based fast ion loss detector on DIII-D

A new scintillator-based fast-ion loss detector (FILD) installed near the outer midplane of the plasma has been commissioned on DIII-D. This detector successfully measures coherent fast ion losses produced by fast-ion driven instabilities ({<=}500 kHz). Combined with the first FILD at {approx}45 Degree-Sign below the outer midplane [R. K. Fisher, et al., Rev. Sci. Instrum. 81, 10D307 (2010)], the two-detector system measures poloidal variation of losses. The phase space sensitivity of the new detector (gyroradius r{sub L}{approx}[1.5-8] cm and pitch angle {alpha}{approx}[35 Degree-Sign -85 Degree-Sign ]) is calibrated using neutral beam first orbit loss measurements. Since fast ion losses are localized poloidally, having two FILDs at different poloidal locations allows for the study of losses over a wider range of plasma shapes and types of loss orbits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Development of radiopure cadmium tungstate crystal scintillators from enriched {sup 106}Cd and {sup 116}Cd to search for double beta decay

Cadmium tungstate crystal scintillators enriched in {sup 106}Cd up to 66% ({sup 106}CdWO{sub 4}) and in {sup 116}Cd up to 82% ({sup 116}CdWO{sub 4}) have been developed. The low radioactive contamination of the crystals measured on the level of ≤ 1.5 mBq/kg ({sup 40}K), ≤ 0.005 - 0.012 mBq/kg ({sup 226}Ra), 0.04 - 0.07 mBq/kg ({sup 228}Th) allows to carry out high sensitivity experiments to search for double beta processes in {sup 106}Cd and {sup 116}Cd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origin of improved scintillation efficiency in (Lu,Gd){sub 3}(Ga,Al){sub 5}O{sub 12}:Ce multicomponent garnets: An X-ray absorption near edge spectroscopy study

In the recent successful improvement of scintillation efficiency in Lu{sub 3}Al{sub 5}O{sub 12}:Ce driven by Ga{sup 3+} and Gd{sup 3+} admixture, the “band-gap engineering” and energy level positioning have been considered the valid strategies so far. This study revealed that this improvement was also associated with the cerium valence instability along with the changes of chemical composition. By utilizing X-ray absorption near edge spectroscopy technique, tuning the Ce{sup 3+}/Ce{sup 4+} ratio by Ga{sup 3+} admixture was evidenced, while it was kept nearly stable with the Gd{sup 3+} admixture. Ce valence instability and Ce{sup 3+}/Ce{sup 4+} ratio in multicomponent garnets can be driven by the energy separation between 4f ground state of Ce{sup 3+} and Fermi level.

36 MATERIALS SCIENCE↗

Taheri-Saramad x-ray detector (TSXD): A novel high spatial resolution x-ray imager based on ZnO nano scintillator wires in polycarbonate membrane

A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 μm, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The response of a fast scintillator screen (YAP:Ce) to low energy ions (0-40 keV) and its use to detect fast-ion-loss in stellarator TJ-II

A systematic study of scintillation materials was undertaken to improve the time resolution of the fast ion diagnostic currently installed at TJ-II stellarator. It was found that YAP:Ce (formula YAlO{sub 3}:Ce, Yttrium Aluminum Perovskite doped with Cerium) ionoluminescence offers better sensitivity and time response compared to the standard detector material, SrGa{sub 2}S{sub 4}:Eu (TG-Green), currently used in TJ-II. A comparison between both materials was carried out by irradiating them with H{sup +} ions of up to 40 keV using a dedicated laboratory setup. It is found that for the low energy ions of interest at TJ-II, YAP:Ce offers 20 times higher sensitivity than TG-Green and much faster decay time, 27 ns versus 540 ns. It is expected that the use of YAP:Ce in combination with a faster data acquisition and an ion counting software as part of the TJ-II ion luminescent probe will provide 20 times faster data on ion loss.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CONSTRAINING THE VELA PULSAR'S RADIO EMISSION REGION USING NYQUIST-LIMITED SCINTILLATION STATISTICS

Using a novel technique, we achieve {approx}100 picoarcsec resolution and set an upper bound of less than 4 km for the characteristic size of the Vela pulsar's emission region. Specifically, we analyze flux-density statistics of the Vela pulsar at 760 MHz. Because the pulsar exhibits strong diffractive scintillation, these statistics convey information about the spatial extent of the radio emission region. We measure both a characteristic size of the emission region and the emission sizes for individual pulses. Our results imply that the radio emission altitude for the Vela pulsar at this frequency is less than 340 km.

79 ASTRONOMY AND ASTROPHYSICS↗

Interstellar scintillation of the double pulsar J0737–3039

We report a series of observations of the interstellar scintillation (ISS) of the double pulsar J0737–3039 over the course of 18 months. As in earlier work, the basic phenomenon is the variation in the ISS caused by the changing transverse velocities of each pulsar, the ionized interstellar medium (IISM), and the Earth. The transverse velocity of the binary system can be determined both by very long baseline interferometry and timing observations. The orbital velocity and inclination is almost completely determined from timing observations, but the direction of the orbital angular momentum is not known. Since the Earth's velocity is known, and can be compared with the orbital velocity by its effect on the timescale of the ISS, we can determine the orientation Ω of the pulsar orbit with respect to equatorial coordinates (Ω = 65 ± 2°). We also resolve the ambiguity (i = 88.°7 or 91.°3) in the inclination of the orbit deduced from the measured Shapiro delay by our estimate i = 88.°1 ± 0.°5. This relies on the analysis of the ISS over both frequency and time, and provides a model for the location, anisotropy, turbulence level, and transverse phase gradient of the IISM. We find that the IISM can be well-modeled during each observation, typically of a few orbital periods, but its turbulence level and mean velocity vary significantly over the 18 months.

79 ASTRONOMY AND ASTROPHYSICS↗

Material identification in x-ray microscopy and micro CT using multi-layer, multi-color scintillation detectors

We demonstrate that a dual-layer, dual-color scintillator construct for microscopic CT, originally proposed to increase sensitivity in synchrotron imaging, can also be used to perform material quantification and classification when coupled with polychromatic illumination. We consider two different approaches to data handling: (1) a data-domain material decomposition whose estimation performance can be characterized by the Cramer-Rao lower bound formalism but which requires careful calibration and (2) an image-domain material classification approach that is more robust to calibration errors. The data-domain analysis indicates that useful levels of SNR (>5) could be achieved in one second or less at typical bending magnet fluxes for relatively large amounts of contrast (several mm path length, such as in a fluid flow experiment) and at typical undulator fluxes for small amount of contrast (tens of microns path length, such as an angiography experiment). The tools introduced could of course be used to study and optimize parameters for a wider range of potential applications. The image domain approach was analyzed in terms of its ability to distinguish different elemental stains by characterizing the angle between the lines traced out in a two-dimensional space of effective attenuation coefficient in the front and back layer images. As a result, this approach was implemented at a synchrotron and the results were consistent with simulation predictions.

36 MATERIALS SCIENCE↗