Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOFTWARE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

DASAO: software tool for the management of safeguards, waste and decommissioning

Decommissioning of nuclear facilities is a complex process involving operations such as detailed surveys, decontamination and dismantling of equipment's, demolition of buildings and management of resulting waste and nuclear materials if any. This process takes place in a well-developed legal framework and is controlled and followed-up by stakeholders like the Safety Authority, the Radwaste management Agency and the Safeguards Organism. In the framework of its nuclear waste and decommissioning program and more specifically the decommissioning of the BR3 reactor, SCK-CEN has developed different software tools to secure the waste and material traceability, to support the sound management of the decommissioning project and to facilitate the control and the follow-up by the stakeholders. In the case of Belgium, it concerns the Federal Agency for Nuclear Control, the National Agency for radioactive waste management and fissile material and EURATOM and IAEA. In 2005, Belgonucleaire decided to shutdown her Dessel MOX fuel fabrication plant and the production stopped in 2006. According to the final decommissioning plan ('PDF') approved by NIRAS, the decommissioning works should start in 2008 at the earliest. In 2006, the management of Belgonucleaire identified the need for an integrated database and decided to entrust SCK-CEN with its development, because SCK-CEN relies on previous experience in comparable applications namely already approved by authorities such as NIRAS, FANC and EURATOM. The main objectives of this integrated software tool are: - simplified and updated safeguards; - waste and material traceability; - computerized documentation; - support to project management; - periodic and final reporting to waste and safety authorities. The software called DASAO (Database for Safeguards, Waste and Decommissioning) was successfully commissioned in 2008 and extensively used from 2009 to the satisfaction of Belgonucleaire and the stakeholders. SCK-CEN is now implementing a simplified release of the software for the management of the decommissioning of the Thetis reactor. Its decommissioning will start in March 2013 and will be completed by the end of 2014. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle, to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-27: A Tool for Routine Quality Assurance of Radiotherapy Dose Calculation Software

Purpose: Dose calculation software is thoroughly evaluated when it is commissioned; however, evaluation of periodic software updates is typically limited in scope due to staffing constraints and the need to quickly return the treatment planning system to clinical service. We developed a tool for quickly and comprehensively testing and documenting dose calculation software against measured data. Methods: A tool was developed using MatLab (The MathWorks, Natick, MA) for evaluation of dose calculation algorithms against measured data. Inputs to the tool are measured data, reference DICOM RT PLAN files describing the measurements, and dose calculations in DICOM format. The tool consists of a collection of extensible modules that can perform analysis of point dose, depth dose curves, and profiles using dose difference, distance-to-agreement, and the gamma-index. Each module generates a report subsection that is incorporated into a master template, which is converted to final form in portable document format (PDF). Results: After each change to the treatment planning system, a report can be generated in approximately 90 minutes. The tool has been in use for more than 5 years, spanning 5 versions of the eMC and 4 versions of the AAA. We have detected changes to the algorithms that affected clinical practice once during this period. Conclusion: Our tool provides an efficient method for quality assurance of dose calculation software, providing a complete set of tests for an update. Future work includes the addition of plan level tests, allowing incorporation of, for example, the TG-119 test suite for IMRT, and integration with the treatment planning system via an application programming interface. Integration with the planning system will permit fully-automated testing and reporting at scheduled intervals.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-04: Integration of Interstitial High Intensity Therapeutic Ultrasound Applicators On a Clinical MRI-Guided High Intensity Focused Ultrasound Treatment Planning Software Platform

Purpose: Interstitial high intensity therapeutic ultrasound (HITU) applicators can be used to ablate tissue percutaneously, allowing for minimally-invasive treatment without ionizing radiation [1,2]. The purpose of this study was to evaluate the feasibility and usability of combining multielement interstitial HITU applicators with a clinical magnetic resonance imaging (MRI)-guided focused ultrasound software platform. Methods: The Sonalleve software platform (Philips Healthcare, Vantaa, Finland) combines anatomical MRI for target selection and multi-planar MRI thermometry to provide real-time temperature information. The MRI-compatible interstitial US applicators (Acoustic MedSystems, Savoy, IL, USA) had 1–4 cylindrical US elements, each 1 cm long with either 180° or 360° of active surface. Each applicator (4 Fr diameter, enclosed within a 13 Fr flexible catheter) was inserted into a tissue-mimicking agar-silica phantom. Degassed water was circulated around the transducers for cooling and coupling. Based on the location of the applicator, a virtual transducer overlay was added to the software to assist targeting and to allow automatic thermometry slice placement. The phantom was sonicated at 7 MHz for 5 minutes with 6–8 W of acoustic power for each element. MR thermometry data were collected during and after sonication. Results: Preliminary testing indicated that the applicator location could be identified in the planning images and the transducer locations predicted within 1 mm accuracy using the overlay. Ablation zones (thermal dose ≥ 240 CEM43) for 2 active, adjacent US elements ranged from 18 mm × 24 mm (width × length) to 25 mm × 25 mm for the 6 W and 8 W sonications, respectively. Conclusion: The combination of interstitial HITU applicators and this software platform holds promise for novel approaches in minimally-invasive MRI-guided therapy, especially when bony structures or air-filled cavities may preclude extracorporeal HIFU.[1] Diederich et al. IEEE UFFFC 46.5 (1999): 1218.[2] Chopra et al. PMB 50.21 (2005): 4957. Funding support was provided by Philips Healthcare and in-kind support from Acoustic MedSystems Inc. Ari Partanen is a paid employee of Philips Healthcare. Goutam Ghoshal and Everette Clif Burdette are paid employees of Acoustic MedSystems Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-133: Assessing IMRT Treatment Delivery Accuracy and Consistency On a Varian TrueBeam Using the SunNuclear PerFraction EPID Dosimetry Software

Purpose: To assess if the TrueBeam HD120 collimator is delivering small IMRT fields accurately and consistently throughout the course of treatment using the SunNuclear PerFraction software. Methods: 7-field IMRT plans for 8 canine patients who passed IMRT QA using SunNuclear Mapcheck DQA were selected for this study. The animals were setup using CBCT image guidance. The EPID fluence maps were captured for each treatment field and each treatment fraction, with the first fraction EPID data serving as the baseline for comparison. The Sun Nuclear PerFraction Software was used to compare the EPID data for subsequent fractions using a Gamma (3%/3mm) pass rate of 90%. To simulate requirements for SRS, the data was reanalyzed using a Gamma (3%/1mm) pass rate of 90%. Low-dose, low- and high gradient thresholds were used to focus the analysis on clinically relevant parts of the dose distribution. Results: Not all fractions could be analyzed, because during some of the treatment courses the DICOM tags in the EPID images intermittently change from CU to US (unspecified), which would indicate a temporary loss of EPID calibration. This technical issue is still being investigated. For the remaining fractions, the vast majority (7/8 of patients, 95% of fractions, and 96.6% of fields) are passing the less stringent Gamma criteria. The more stringent Gamma criteria caused a drop in pass rate (90 % of fractions, 84% of fields). For the patient with the lowest pass rate, wet towel bolus was used. Another patient with low pass rates experienced masseter muscle wasting. Conclusion: EPID dosimetry using the PerFraction software demonstrated that the majority of fields passed a Gamma (3%/3mm) for IMRT treatments delivered with a TrueBeam HD120 MLC. Pass rates dropped for a DTA of 1mm to model SRS tolerances. PerFraction pass rates can flag missing bolus or internal shields. Sanjeev Saini is an employee of Sun Nuclear Corporation. For this study, a pre-release version of PerFRACTION 1.1 software from Sun Nuclear Corporation was used.

60 APPLIED LIFE SCIENCES↗

SU-F-P-54: Guidelines to Check Image Registration QA of a Clinical Deformation Registration Software: A Single Institution Preliminary Study

Purpose: The objective of this study is to verify and analyze the accuracy of a clinical deformable image registration (DIR) software. Methods: To test clinical DIR software qualitatively and quantitatively, we focused on lung radiotherapy and analyzed a single (Lung) patient CT scan. Artificial anatomical changes were applied to account for daily variations during the course of treatment including the planning target volume (PTV) and organs at risk (OAR). The primary CT (pCT) and the structure set (pST) was deformed with commercial tool (ImSimQA-Oncology Systems Limited) and after artificial deformation (dCT and dST) sent to another commercial tool (VelocityAI-Varian Medical Systems). In Velocity, the deformed CT and structures (dCT and dST) were inversely deformed back to original primary CT (dbpCT and dbpST). We compared the dbpST and pST structure sets using similarity metrics. Furthermore, a binary deformation field vector (BDF) was created and sent to ImSimQA software for comparison with known “ground truth” deformation vector fields (DVF). Results: An image similarity comparison was made by using “ground truth” DVF and “deformed output” BDF with an output of normalized “cross correlation (CC)” and “mutual information (MI)” in ImSimQA software. Results for the lung case were MI=0.66 and CC=0.99. The artificial structure deformation in both pST and dbpST was analyzed using DICE coefficient, mean distance to conformity (MDC) and deformation field error volume histogram (DFEVH) by comparing them before and after inverse deformation. We have noticed inadequate structure match for CTV, ITV and PTV due to close proximity of heart and overall affected by lung expansion. Conclusion: We have seen similarity between pCT and dbpCT but not so well between pST and dbpST, because of inadequate structure deformation in clinical DIR system. This system based quality assurance test will prepare us for adopting the guidelines of upcoming AAPM task group 132 protocol.

60 APPLIED LIFE SCIENCES↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-06: Evaluation of a Novel Radiosurgery Software for Treating Multiple Brain Metastases Simultaneously in a Single Fraction

Purpose: To evaluate a new, automated brain metastases planning software designed to treat up to ten brain metastases simultaneously. Methods: We treated 61 patients with multiple brain metastases using the Elements software by BrainLab (Munich, Germany). Patients had between 2–10 metastases ranging from 0.01–8.64 cc. Dose prescription was 18–24 Gy. Plans use up to 5 non-coplanar arcs with a single isocenter at the metastases’ center of mass. The high degree of automation shortens the planning time to 15–20 minutes per patient.For comparison we planned 21 of the patients using Rapid Arc (Varian, Palo Alto CA) (RA). We used two coplanar arcs so as to keep planning times comparable to the Elements. We also planned 8 patients using iPlan software (BrainLab). We compared conformity index (CI), volume of brain receiving over 12 Gy (V{sub 12}) and mean brain dose (MBD) for the three different planning systems (TPSs). Results: Plans from all TPSs were judged clinically acceptable. V{sub 12} and MBD were not statistically significantly different between TPSs.CI between RA and Elements was similar, however for iPlan CI was significantly worse compared to both RA and Elements (p<0.001). RA plans took approximately 40 minutes to plan (despite fusion and contouring being done in the Elements), and iPlan plans over an hour each. Delivery times were approximately 30 minutes for Elements, 10 minutes for RA, and up to 300 minutes for iPlan. Conclusion: Elements plans had good CI values and low brain doses. While treatment times for Elements were longer than for RA, 30 minutes is a significant improvement over conventional radiosurgery techniques where each metastasis is treated individually and delivery times to 10 metastases are close to 300 minutes.BrainLab Elements is a novel software allowing fast, automated planning and efficient irradiation of multiple brain metastases with minimal dose to healthy brain.

60 APPLIED LIFE SCIENCES↗

The critical importance of software for HEP

Particle physics has an ambitious and broad global experimental programme for the coming decades. Large investments in building new facilities are already underway or under consideration. Scaling the present processing power and data storage needs by the foreseen increase in data rates in the next decade for HL-LHC is not sustainable within the current budgets. As a result, a more efficient usage of computing resources is required in order to realise the physics potential of future experiments. Software and computing are an integral part of experimental design, trigger and data acquisition, simulation, reconstruction, and analysis, as well as related theoretical predictions. A significant investment in computing and software is therefore critical. Advances in software and computing, including artificial intelligence (AI) and machine learning (ML), will be key for solving these challenges. Making better use of new processing hardware such as graphical processing units (GPUs) or ARM chips is a growing trend. This forms part of a computing solution that makes efficient use of facilities and contributes to the reduction of the environmental footprint of HEP computing. The HEP community already provided a roadmap for software and computing for the last EPPSU, and this paper updates that, with a focus on the most resource critical parts of our data processing chain.

97 MATHEMATICS AND COMPUTING↗

SoS-SDQN: System of Systems Software-defined Quantum Networking

Quantum networks are needed for quantum domain applications that may run across different network deployments - point-to-point, multi-node networks, and possibly across inter-domain quantum networks, like the quantum internet. Unlike classical computing networks, quantum networks involve heterogeneous systems nodes that currently require local and manual control. This needs a unified control approach to help them integrate, work seamlessly, and have global knowledge. Software-defined Networking (SDN) has been successfully leveraged in classical networking for seamless and software-driven control of network infrastructure and packet switching, but not in management of quantum network applications across heterogeneous systems. In this paper, we review the current state of the art and present early developments of a System-of-Systems Software-defined Quantum Networking architecture (SoS-SDQN), a generic architecture that supports software-driven quantum network experiments across heterogeneous quantum systems. The architecture modifies the generic SDN to address the domain requirements of quantum networks and proposes a multilevel SDQN to provide a global view of network status, running applications, and control of incorporated heterogeneous quantum systems. We also design and implement a SoS SouthBound Quantum Interface (SoS-SBQI), a quantum infrastructure protocol that abstracts automation of applications across the network.

Alnajjar, Anees [ORNL] (ORCID:0000000237101601)↗

GridOPTICS Software System

GridOPTICS Software System (GOSS) is a middleware that facilitates creation of new, modular and flexible operational and planning platforms that can meet the challenges of the next generation power grid. GOSS enables Department of Energy, power system utilities, and vendors to build better tools faster. GOSS makes it possible to integrate Future Power Grid Initiative software products/prototypes into existing power grid software systems, including the PNNL PowerNet and EIOC environments. GOSS is designed to allow power grid applications developed for different underlying software platforms installed in different utilities to communicate with ease. This can be done in compliance with existing security and data sharing policies between the utilities. GOSS not only supports one-to-one data transfer between applications, but also publisher/subscriber scheme. To support interoperability requirements of future EMS, GOSS is designed for CIM compliance. In addition to this, it supports authentication and authorization capabilities to protect the system from cyber threats. In summary, the contributions of the GOSS middleware are as follows: A platform to support future EMS development. A middleware that promotes interoperability between power grid applications. A distributed architecture that separates data sources from power grid applications. Support for data exchange with either one-to-one or publisher/subscriber interfaces. An authentication and authorization scheme for limiting the access to data between utilities.

Akyol, BoraA↗

Advanced Tri-lab Software Environment (ATSE)

The Advanced Tri-lab Software Environment (ATSE) is an effort to build an open, modular, extensible, community-engaged, and vendor-adaptable software ecosystem that enables the prototyping of new technologies for improving the ASC computing environment. The initial target for ATSE is to accelerate the maturity of the Arm ecosystem for supporting ASC computing and the high-performance computing community more broadly. ATSE provides an integrated and optimized software stack that includes: 1) Application development environment and libraries including compilers, math libraries, tools, MPI, and OpenMP, 2) Low-level system software including optimized Linux, network stack, file systems, containers, and virtual machines, 3) Job scheduling and management including workload manager, application launcher, and user tools, and 4) System administration and management tools supporting booting, monitoring, and operating system image management. SAND2020-12377 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Younge, Andrew J.↗

HALOS (Heliostat Aimpoint and Layout Optimization Software) [SWR-21-41]

Heliostat Aimpoint and Layout Optimization Software (HALOS) is an open-source software package that allows users to explore solar field layout optimization, aimpoint strategy optimization, and performance characterization of concentrating solar power tower plants. Users interface with the tool through python, and results are reported in time series tables, plots, runtime logs, and flat-file outputs. Users choose from a list of variables such as tower height, receiver capacity, flux limits, design-point irradiance, etc., and specify information about the system using a small collection of flat files. The software can then optimize the specified variables (e.g., aimpoints for each heliostat) to maximize the thermal energy delivered to the receiver while adhering to flux limits. HALOS is implemented to be flexible with respect to flux characterization methods, but includes a direct connection to NREL's SolarPILOT™ software via its python API so that users can utilize high-fidelity flux simulation methods that have already been developed.

Zolan, Alexander↗

NERSC Slurm Software Configurations and Plugins

This software can be used to tune the HPC operations of a Cray system running Slurm workload manager software. This includes many of the customizations that NERSC has made over the past three years. In particular these customizations allow for complex site-local policies to be implemented and managed in a scalable way, or add unique capabilities to slurm via our plugins, including: * performance software integration and compute node staging * temporary directory/dynamic user content management automation * software defined networking integration

Jacobsen, Douglas↗

A Closed-Loop Proportional-Integral (PI) Control Software for Fully Mechanically Controlled Automated Electron Microscopic Tomography

A closed-loop proportional-integral (PI) control software is provided for fully mechanically controlled automated electron microscopic tomography. The software is developed based on Gatan DigitalMicrograph, and is compatible with Zeiss LIBRA 120 transmission electron microscope. However, it can be expanded to other TEM instrument with modification. The software consists of a graphical user interface, a digital PI controller, an image analyzing unit, and other drive units (i.e.: image acquire unit and goniometer drive unit). During a tomography data collection process, the image analyzing unit analyzes both the accumulated shift and defocus value of the latest acquired image, and provides the results to the digital PI controller. The digital PI control compares the results with the preset values and determines the optimum adjustments of the goniometer. The goniometer drive unit adjusts the spatial position of the specimen according to the instructions given by the digital PI controller for the next tilt angle and image acquisition. The goniometer drive unit achieves high precision positioning by using a backlash elimination method. The major benefits of the software are: 1) the goniometer drive unit keeps pre-aligned/optimized beam conditions unchanged and achieves position tracking solely through mechanical control; 2) the image analyzing unit relies on only historical data and therefore does not require additional images/exposures; 3) the PI controller enables the system to dynamically track the imaging target with extremely low system error.

Ren, Gang↗

Complex software dedicated for design and simulation of LPCE process for heavy water detritiation

The main purpose of this paper is to present a comprehensive software, SICA, designed to be used in water-hydrogen liquid phase catalytic exchange process (LPCE). The software calculates the water-gas catalytic isotopic exchange process, following the transfer of any H, D or T isotope from water to gas and vice versa. This software is useful for both design and laboratory-based research; the type of the catalytic filling (ordered or random) can be defined for any of these 2 cases, the isotopic calculation being specific to the package type. For the laboratory-based research, the performance of a catalytic packing can be determined by knowing the type and by using experimental results. Performance of the mixed catalytic packing is defined by mass transfer constants for each catalytic and hydrophilic package in that specific arrangement, and also for the isotope whose transfer is studied from one phase to another. Also, it has been established a link between these constants and commonly used parameters for the fillings performance defined by HETP (Height Equivalent of Theoretical Plate). To demonstrate the performance of the software, we present a comparative analysis of water-gas catalytic isotopic exchange on a column equipped with 3 types of filling: successive layers, random and structured (ordered package filled with catalyst). The program can be used for the LPCE process calculation, process used at detritiation facilities for CANDU reactors or fusion reactors. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAMA Software Features: Errors, Uncertainty, and Standards

This document reviews the sources of uncertainty, standards, and the UQ development plan for the MAMA software. Our intention is to allow users to generate quantification data with uncertainty based on the contributing back end sources. We do not intend to add in front end uncertainty into the software itself, due to the numerous different instruments that could be used, and the enormous variation in factors that would add to that uncertainty among different users, samples, and sample prep routines. We could not possibly or reasonably address them all. We will however, add in the uncertainty component from the image scale bar, which must be provided by the user as an input to the software, and could be used to incorporate any front end uncertainty. (Note: the detailing of these front end uncertainties is beyond the scope of this software effort.) The verification testing we have done generates uncertainties that are fundamentally pixel based. Given the uncertainty in the scale bar, we can then propagate the uncertainty and convert to uncertainty in all calculated results in microns (or whatever unit the scale bar is in.) Users can then add any additional instrumentation and sample prep uncertainty to the resulting output as appropriate for the data calculation and analysis being performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dual-Slab Verification Detector (DSVD) Operations Software User Guide

The Dual-Slab Verification Detector (DSVD) is used with a MiniGRAND to acquire data at different positions on a spent-fuel cask and then to make a determination regarding the safeguards status of the fuel stored in the cask. The software described in this document, the DSVD Operations Software, provides an interface to perform the various activities required to use the DSVD to make safeguards determinations. Data acquired by the software is saved in a set of worksheets in an Excel spreadsheet. Plateau, background, and calibration data are each placed on separate pages, and each cask has its own page containing data acquired for that cask. The spreadsheet is backed up each time the software begins executing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗