Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Ammonia thermometry of star-forming galaxies

With a goal toward deriving the physical conditions in external galaxies, we present a study of the ammonia (NH{sub 3}) emission and absorption in a sample of star-forming systems. Using the unique sensitivities to kinetic temperature afforded by the excitation characteristics of several inversion transitions of NH{sub 3}, we have continued our characterization of the dense gas in star-forming galaxies by measuring the kinetic temperature in a sample of 23 galaxies and one galaxy offset position selected for their high infrared luminosity. We derive kinetic temperatures toward 13 galaxies, 9 of which possess multiple kinetic temperature and/or velocity components. Eight of these galaxies exhibit kinetic temperatures >100 K, which are in many cases at least a factor of two larger than kinetic temperatures derived previously. Furthermore, the derived kinetic temperatures in our galaxy sample, which are in many cases at least a factor of two larger than derived dust temperatures, point to a problem with the common assumption that dust and gas kinetic temperatures are equivalent. As previously suggested, the use of dust emission at wavelengths greater than 160 μm to derive dust temperatures, or dust heating from older stellar populations, may be skewing derived dust temperatures in these galaxies to lower values. We confirm the detection of high-excitation OH {sup 2}Π{sub 3/2} J = 9/2 absorption toward Arp 220. We also report the first detections of non-metastable NH{sub 3} inversion transitions toward external galaxies in the (2,1) (NGC 253, NGC 660, IC 342, and IC 860), (3,1), (3,2), (4,3), (5,4) (all in NGC 660), and (10,9) (Arp 220) transitions.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining Equilibrium Position For Acoustical Levitation

Equilibrium position and orientation of acoustically-levitated weightless object determined by calibration technique on Earth. From calibration data, possible to calculate equilibrium position and orientation in presence of Earth gravitation. Sample not levitated acoustically during calibration. Technique relies on Boltzmann-Ehrenfest adiabatic-invariance principle. One converts resonant-frequency-shift data into data on normalized acoustical potential energy. Minimum of energy occurs at equilibrium point. From gradients of acoustical potential energy, one calculates acoustical restoring force or torque on objects as function of deviation from equilibrium position or orientation.

Barmatz, M. B.↗

A model study of potential sampling errors due to data scatter around expendable bathythermograph transects in the tropical Pacific

A linear multiple vertical-mode model described by McPhaden et al. (1988) is used to examine potential errors due to data scatter around expendable bathythermograph (XBT) transects in the tropical Pacific. Two methods of sampling are compared. In the first, the model was sampled along approximately straight lines of grid points corresponding to the mean positions of XBT tracks in the eastern, central, and western Pacific; in the second, the model was sampled again at the dates and locations of actual XTB casts for 1979-1983. The model indicates that the data scattered zonally around XBT transects in general can lead to about 2 dyn cm error in dynamic height in composite sections of XBT data. Errors larger than 2 dyn cm occurred in regions where XBT sample spacing in the zonal direction was insufficient to resolve Rossby wave variations in the model.

Mcphaden, Michael J.↗

Electric field measurements of DC-driven positive streamer coronas using the E-FISH method

This paper reports on electric field measurements, using the electric field-induced second harmonic (E-FISH) method, sampling the spatial structure and temporal development of DC-driven positive streamer coronas in atmospheric-pressure air at relevant timescales to examine the self-pulsating behavior of the discharge. The discharge is triggered from a point-to-plate geometry and consists of transient coronas, which bridge the inter-electrode gap and pulsate at about 3 kHz, superimposed with a persisting glow corona. The measurements presented challenge the phenomenological explanation for the pulsations based on field recovery at the anode driven by the evacuation of positive ions by electric drift effects and hint at a propagating wave-like feature from the plate-cathode to the tip-anode.

42 ENGINEERING↗

Selecting samples of galaxies with fewer Fingers-of-God

The radial positions of galaxies inferred from their measured redshift appear distorted due to their peculiar velocities. We argue that the contribution from stochastic velocities — which gives rise to `Fingers-of-God' (FoG) anisotropy in the inferred maps — does not lend itself to perturbative modelling already on scales targeted by current experiments. To get around this limitation, we propose to remove FoG using data-driven indicators of their abundance that are local in nature and thus avoid selection biases. In particular, we show that the scale where the measured power spectrum quadrupole changes sign is tightly anti-correlated with both the satellite fraction and the velocity dispersion, and can thus be used to select galaxy samples with fewer FoG. In addition, we show that excluding galaxies in haloes more massive than a given mass threshold can help to discard many of the most problematic galaxies. Such selection could be achieved in practice using maps of the thermal Sunyaev-Zel'dovich distortion of the cosmic microwave background frequency spectrum. These techniques could potentially improve reconstructions of the large-scale velocity and displacement fields from the redshift-space positions of galaxies. They may also extend the reach of perturbative models for galaxy clustering, though in practice we find only marginal gains when fitting one-loop EFTofLSS models to simulations with mitigated FoG due to the relevance of other effects entering at two-loop order.

cosmological parameters from LSS↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evidence of galaxy assembly bias in SDSS DR7 galaxy samples from count statistics

We present observational constraints on the galaxy–halo connection, focusing particularly on galaxy assembly bias from a novel combination of counts-in-cylinders statistics, P(N CIC ), with the standard measurements of the projected two-point correlation function w p (r p ), and number density n gal of galaxies. We measure n gal , w p (r p ), and P(N CIC ) for volume-limited, luminosity-threshold samples of galaxies selected from SDSS DR7, and use them to constrain halo occupation distribution (HOD) models, including a model in which galaxy occupation depends upon a secondary halo property, namely halo concentration. We detect significant positive central assembly bias for the M r < -20.0 and M r <-19.5 samples. Central galaxies preferentially reside within haloes of high concentration at fixed mass. Positive central assembly bias is also favoured in the M r < -20.5 and M r < -19.0 samples. We find no evidence of central assembly bias in the M r < -21.0 sample. We observe only a marginal preference for negative satellite assembly bias in the M r < -20.0 and M r < -19.0 samples, and non-zero satellite assembly bias is not indicated in other samples. Our findings underscore the necessity of accounting for galaxy assembly bias when interpreting galaxy survey data, and demonstrate the potential of count statistics in extracting information from the spatial distribution of galaxies, which could be applied to both galaxy–halo connection studies and cosmological analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Sample Processor for Life on Icy Worlds (SPLIce): Monolithic Manifold-Based System to Recover, Prepare, and Deliver Samples and Standards to Instrumentation Suites for Ocean World Life-Search Missions

A claim of life detection on one of the solar system’s icy ocean worlds would necessitate extraordinarily convincing evidence. Limited energy availability in the oceans of such bodies as Europa and Enceladus argues for microbes as most probable among possible life forms, but evidence of their existence in the surface layers of an icy moon or in a frozen plume ejected into space could take various forms, pointing to instrumentation suites as a preferred means to detect diverse molecular and morphological life indicators. Multiple disparate categories of positive detections could provide truly convincing evidence from samples that may be only a few micro-liters. SPLIce’s Foundation. Teams led by NASA’s Ames Research Center have developed and operated numerous small, live-biology and astrobiology science payloads in space over two decades. Since 2016, we have adapted and augmented their biological sample-handling systems to create compact, robust search-for-life fluidic processors designed to function after a decade or more in transit, in environments with very little gravity and lots of radiation: up to 100’s of kilorads.

Instrumentation suite↗

Effects of Static Recrystallization and Precipitation on Mechanical Properties of 00Cr12 Ferritic Stainless Steel

The 00Cr12 ferritic stainless steel samples were isothermally held at different temperatures in the range of 700 °C to 1000 °C to investigate the effect of static recrystallization and precipitation on mechanical properties, such as microhardness, tensile strength, and yield strength. The results show that the formation of the fine recrystallized grain, as well as precipitation, coarsening, and dissolution of the second-phase particles, influences the mechanical properties remarkably. The fine recrystallized grain can provide a positive grain boundary-strengthening effect in the sample under a relatively high holding temperature. Coarsening and dissolution of M{sub 23}C{sub 6} result in partial depletion of precipitate hardening. In contrast, the size and number density of MX particles are almost constant, regardless of the holding temperature; therefore, it can provide a better precipitation-hardening effect.

36 MATERIALS SCIENCE↗

Fermiology of a topological line-nodal compound CaSb 2 and its implication to superconductivity: Angle-resolved photoemission study

Here, we performed angle-resolved photoemission spectroscopy with microfocused beam on a topological line-nodal compound CaSb 2 which undergoes a superconducting transition at the onset T c ~ 1.8 K, to clarify the Fermi-surface topology relevant to the occurrence of superconductivity. We found that a three-dimensional hole pocket at the Γ point is commonly seen for two types of single-crystalline samples fabricated by different growth conditions. On the other hand, the carrier-doping level estimated from the position of the chemical potential was found to be sensitive to the sample fabrication condition. The cylindrical electron pocket at the Y(C) point predicted by the calculations is absent in one of the two samples, despite the fact that both samples commonly show superconductivity with similar T c 's. This suggests a key role of the three-dimensional hole pocket to the occurrence of superconductivity, and further points to an intriguing possibility to control the topological nature of superconductivity by carrier tuning in CaSb 2 .

36 MATERIALS SCIENCE↗

Rotational positioning system adapted to atomic force microscope for measuring anisotropic surface properties

The diverse atomic configurations induce the anisotropic surface properties. For investigating anisotropic phenomena, we developed a rotational positioning system adapted to atomic force microscope (AFM). This rotational positioning system is applied to revolve the measured sample to defined angular direction, and it composed of an inertial rotational stepper and a visual angular measurement. The inertial rotational stepper with diameter 30 mm and height 7.6 mm can be easily attached to the AFM-system built in any general optical microscope. Based on a clearance less bearing and the inertial driving method, its bidirectional angular resolution reaches 0.005 deg. per step. For realizing a close-loop controlled angular positioning function, the visual measurement method is utilized. Through the feedback control, the angular positioning error is less than 0.01 deg. For verifying the system performance, we used it to investigate the anisotropic surface properties of graphite. Through a modified cantilever tip, the atomic-scale stick-slip, and the anisotropic friction phenomena can be distinctly detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chaotic neural dynamics facilitate probabilistic computations through sampling

Cortical neurons exhibit highly variable responses over trials and time. Theoretical works posit that this variability arises potentially from chaotic network dynamics of recurrently connected neurons. Here, we demonstrate that chaotic neural dynamics, formed through synaptic learning, allow networks to perform sensory cue integration in a sampling-based implementation. We show that the emergent chaotic dynamics provide neural substrates for generating samples not only of a static variable but also of a dynamical trajectory, where generic recurrent networks acquire these abilities with a biologically plausible learning rule through trial and error. Furthermore, the networks generalize their experience in the stimulus-evoked samples to the inference without partial or all sensory information, which suggests a computational role of spontaneous activity as a representation of the priors as well as a tractable biological computation for marginal distributions. These findings suggest that chaotic neural dynamics may serve for the brain function as a Bayesian generative model.

60 APPLIED LIFE SCIENCES↗

Design and feasibility of a novel program of cervical screening in Nigeria: self-sampled HPV testing paired with visual triage

Background: Accelerated global control of cervical cancer would require primary prevention with human papillomavirus (HPV) vaccination in addition to novel screening program strategies that are simple, inexpensive, and effective. We present the feasibility and outcome of a community-based HPV self-sampled screening program. Methods: In Ile Ife, Nigeria, 9406 women aged 30–49 years collected vaginal self-samples, which were tested for HPV in the local study laboratory using Hybrid Capture-2 (HC2) (Qiagen). HPV-positive women were referred to the colposcopy clinic. Gynecologist colposcopic impression dictated immediate management; biopsies were taken when definite acetowhitening was present to produce a histopathologic reference standard of precancer (and to determine final clinical management). Retrospective linkage to the medical records identified 442 of 9406 women living with HIV (WLWH). Results: With self-sampling, it was possible to screen more than 100 women per day per clinic. Following an audio-visual presentation and in-person instructions, overall acceptability of self-sampling was very high (81.2% women preferring self-sampling over clinician collection). HPV positivity was found in 17.3% of women. Intensive follow-up contributed to 85.9% attendance at the colposcopy clinic. Of those referred, 8.2% were initially treated with thermal ablation and 5.6% with large loop excision of transformation zone (LLETZ). Full visibility of the squamocolumnar junction, necessary for optimal visual triage and ablation, declined from 68.5% at age 30 to 35.4% at age 49. CIN2+ and CIN3+ (CIN- Cervical intraepithelial neoplasia), including five cancers, were identified by histology in 5.9 and 3.2% of the HPV-positive women, respectively (0.9 and 0.5% of the total screening population), leading to additional treatment as indicated. The prevalences of HPV infection and CIN2+ were substantially higher (40.5 and 2.5%, respectively) among WLWH. Colposcopic impression led to over- and under-treatment compared to the histopathology reference standard. Conclusion: A cervical cancer screening program using self-sampled HPV testing, with colposcopic immediate management of women positive for HPV, proved feasible in Nigeria. Based on the collected specimens and images, we are now evaluating the use of a combination of partial HPV typing and automated visual evaluation (AVE) of cervical images to improve the accuracy of the screening program.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid chromatography detection unit, system, and method

An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a Method To Quantify Soil Bacterial Abundance by Flow Cytometry

ABSTRACT Bacterial abundance is a fundamental metric for understanding the population dynamics of soil bacteria and their role in biogeochemical cycles. Despite its importance, methodological constraints hamper our ability to assess bacterial abundance in terrestrial environments. Here, we aimed to optimize the use of flow cytometry (FCM) to assay bacterial abundances in soil while providing a rigorous quantification of its limitations. Soil samples were spiked with Escherichia coli to evaluate the levels of recovery efficiency among three extraction approaches. The optimized method added a surfactant (a tetrasodium pyrophosphate [TSP] buffer) to 0.1 g of soil, applied an intermediate degree of agitation through shaking, and used a Nycodenz density gradient to separate the cells from background debris. This procedure resulted in a high (average, 89%) level of cell recovery. Recovery efficiencies did not differ significantly among sites across an elevation gradient but were positively correlated with percent carbon in the soil samples. Estimated abundances were also highly repeatable between technical replicates. The method was applied to samples from two field studies and, in both cases, was sensitive enough to detect treatment and site differences in bacterial abundances. We conclude that FCM offers a fast and sensitive method to assay soil bacterial abundance from relatively small amounts of soil. Further work is needed to assay differential biases of the method across a wider range of soil types. IMPORTANCE The ability to quantify bacterial abundance is important for understanding the contributions of microbial communities in soils, but such assays remain difficult and time-consuming. Flow cytometry offers a fast and direct way to count bacterial cells, but several concerns remain in applying the technique to soils. This study aimed to improve the efficiency of the method for soil while quantifying its limitations. We demonstrated that an optimized procedure was sensitive enough to capture differences in bacterial abundances among treatments and ecosystems in two field studies.

54 ENVIRONMENTAL SCIENCES↗

Detection of Anatoxins in Human Urine by Liquid Chromatography Triple Quadrupole Mass Spectrometry and ELISA

Harmful cyanobacterial blooms are becoming more common and persistent around the world. When in bloom, various cyanobacterial strains can produce anatoxins in high concentrations, which, unlike other cyanobacterial toxins, may be present in clear water. Potential human and animal exposures to anatoxins occur mainly through unintentional ingestion of contaminated algal mats and water. To address this public health threat, we developed and validated an LC-MS/MS method to detect anatoxins in human urine to confirm exposures. Pooled urine was fortified with anatoxin-a and dihydroanatoxin at concentrations from 10.0 to 500 ng/mL to create calibrators and quality control samples. Samples were diluted with isotopically labeled anatoxin and solvent prior to LC-MS/MS analysis. This method can accurately quantitate anatoxin-a with inter- and intraday accuracies ranging from 98.5 to 103% and relative standard deviations < 15%, which is within analytical guidelines for mass spectrometry methods. Additionally, this method qualitatively detects a common degradation product of anatoxin, dihydroanatoxin, above 10 ng/mL. We also evaluated a commercial anatoxin-a ELISA kit for potential diagnostic use; however, numerous false positives were detected from unexposed individual human urine samples. In conclusion, we have developed a method to detect anatoxins precisely and accurately in urine samples, addressing a public health area of concern, which can be applied to future exposure events.

urine↗

Information management during decommissioning - 15613

A significant amount of data is collected during radiological survey and control measurements before clearance in a decommissioning project, and data quality has often been a challenge. An integrated information management system has been developed, and is in use for the R2 facility radiological survey. Special attention has been given to data quality assurance, in order to extend the data life span. A positioning system using Radio-frequency identification (RFID) has been developed to allow automatic registration of where measurements and sampling are performed in the facility, thus eliminating the need for manual entering of the position. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗