Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RELAXATION TIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Experimental determination of the temperature-dependent Van Hove function in a Zr 80 Pt 20 liquid

Even though the viscosity is one of the most fundamental properties of liquids, the connection with the atomic structure of the liquid has proven elusive. By combining inelastic neutron scattering with the electrostatic levitation technique, the time-dependent pair-distribution function (i.e., the Van Hove function) has been determined for liquid Zr 80 Pt 20 . We show that the decay time of the first peak of the Van Hove function is directly related to the Maxwell relaxation time of the liquid, which is proportional to the shear viscosity. This result demonstrates that the local dynamics for increasing or decreasing the coordination number of local clusters by one determines the viscosity at high temperature, supporting earlier predictions from molecular dynamics simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonextensive hydrodynamics of boost-invariant plasmas

We use quasiparticle anisotropic hydrodynamics to study the non-conformal and non-extensive dynamics of a system undergoing boost-invariant Bjorken expansion. To introduce nonextensivity, we use an underlying Tsallis distribution with a time-dependent nonextensivity parameter q. By taking moments of the quasiparticle Boltzmann equation in the relaxation-time approximation, we obtain dynamical equations which allow us to determine the time evolution of all microscopic parameters including q. We compare numerical solutions for bulk observables obtained using the nonextensive evolution with results obtained using quasiparticle anisotropic hydrodynamics with a Boltzmann distribution function (q → 1). We show that the evolution of the temperature, pressure ratio, and scaled energy density, are quite insensitive to which distribution function is assumed. However, we find significant differences in the early-time evolution of the bulk pressure which are observed for even small deviations from the Boltzmann distribution function. Finally, we discuss the existence of non-conformal hydrodynamic attractors for the longitudinal and transverse pressures, the bulk and shear viscous corrections, and the nonextensivity parameter q.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical predictions of residence times behind a rearward facing step with transverse injection

A numerical investigation of the two-dimensional recirculation zone formed between a rear-ward facing step and a transverse hydrogen jet in a supersonic flow is presented. Calculations were made using an elliptic flow computer code with a time-relaxation finite difference integration algorithm. Cases were examined for jet static pressures between 2 and 5 times mainstream with jets located 3 to 7 step heights downstream of the step. Nominal mainstream flow conditions were Mach 2.4 air at 1 atm pressure and 1000K (1800R) static temperature. Results in the form of mean properties in the recirculation zone and residence time are presented. Calculations of the decay of hydrogen mass from the steady state are presented for selected cases. The combustion potential for each case is assessed by comparison of computed conditions in the recirculation zone with the results from a well-stirred reactor theory.

Rogers, R. C.↗

Numerical predictions of residence times behind a rearward facing step with transverse injection

A numerical investigation of the two-dimensional recirculation zone formed between a rearward facing step and a transverse hydrogen jet in a supersonic flow is presented. Calculations were made using an elliptic flow computer code with a time-relaxation finite difference integration algorithm. Cases were examined for jet static pressures between 2 and 5 times mainstream with jets located 3 to 7 step heights downstream of the step. Nominal mainstream flow conditions were Mach 2.4 air at 1 atm pressure and 1000 K (1800 R) static temperature. Results in the form of mean properties in the recirculation zone and residence time are presented. Calculations of the decay of hydrogen mass from the steady state are presented for selected cases. The combustion potential for each case is assessed by comparison of computed conditions in the recirculation zone with the results from a well-stirred reactor theory.

Rogers, R. C.↗

FDTD modeling of induced polarization phenomena in transient electromagnetics

The finite-difference time-domain scheme is augmented in order to treat the modelling of transient electromagnetic signals containing induced polarization effects from 3-D distributions of polarizable media. Compared to the non-dispersive problem, the discrete dispersive Maxwell system contains costly convolution operators. Key components to our solution for highly digitized model meshes are Debye decomposition and composite memory variables. We revert to the popular Cole-Cole model of dispersion to describe the frequency-dependent behaviour of electrical conductivity. Its inversely Laplace-transformed Debye decomposition results in a series of time convolutions between electric field and exponential decay functions, with the latter reflecting each Debye constituents' individual relaxation time. Finally, these function types in the discrete-time convolution allow for their substitution by memory variables, annihilating the otherwise prohibitive computing demands. Numerical examples demonstrate the efficiency and practicality of our algorithm.

58 GEOSCIENCES↗

Dynamics of nonequilibrium magnons in gapped Heisenberg antiferromagnets

Nonequilibrium dynamics in spin systems is a topic currently under intense investigation as it provides fundamental insights into thermalization, universality, and exotic transport phenomena. While most of the studies have been focused on ideal closed quantum many-body systems such as ultracold atomic quantum gases and one-dimensional spin chains, driven-dissipative Bose gases in steady states away from equilibrium in classical systems also lead to intriguing nonequilibrium physics. Here, in this work, we theoretically investigate out-of-equilibrium dynamics of magnons in a gapped Heisenberg quantum antiferromagnet based on Boltzmann transport theory. We show that, by treating scattering terms beyond the relaxation-time approximation in the Boltzmann transport equation, energy and particle number conservation mandate that nonequilibrium magnons cannot relax to equilibrium, but decay to other nonequilibrium stationary states. The only decay channel for these stationary states back to equilibrium is through the nonconserving interactions (i.e., changing particle number and/or energy within the magnon system) such as boundary or magnon-phonon scattering. At low temperatures, these nonconserving interactions are much slower processes than intrinsic magnon-magnon interaction in a gapped spin system. Using magnon-phonon interaction as a quintessential type of nonconserving interaction, we then propose that nonequilibrium steady states of magnons can be maintained and tailored using periodic driving at frequencies faster than relaxation due to phonon interactions. These findings reveal a class of classical material systems that are suitable platforms to study nonequilibrium statistical physics and macroscopic phenomena such as classical Bose-Einstein condensation of quasiparticles and magnon supercurrents that are relevant for spintronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Particle Dynamics in a Diblock-Copolymer-Based Dodecagonal Quasicrystal and Its Periodic Approximant by X-Ray Photon Correlation Spectroscopy

Temperature-dependent X-ray photon correlation spectroscopy (XPCS) measurements are reported for a binary diblock copolymer blend that self-assembles into an aperiodic dodecagonal quasicrystal (DDQC) and a periodic Frank-Kasper σ phase approximant. The measured structural relaxation times are Bragg scattering wavevector-independent and are five times faster in the DDQC than the σ phase, with minimal temperature dependence. Further, the underlying dynamical relaxations are ascribed to differences in particle motion at the grain boundaries within each of these tetrahedrally close-packed assemblies. These results identify unprecedented particle dynamics measurements of tetrahedrally-coordinated micellar block polymers, thus expanding the application of XPCS to ordered soft materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{sup 1}H nuclear magnetic resonance study of hydrated water dynamics in perfluorosulfonic acid ionomer Nafion

We have studied the dynamics of hydrated water molecules in the proton exchange membrane of Nafion by means of high-resolution {sup 1}H nuclear magnetic resonance (NMR) measurements. “Bound” and “free” states of hydrated water clusters as well as the exchange protons were identified from the NMR chemical shift measurements, and their activation energies were obtained from the temperature-dependent laboratory- and rotating-frame spin-lattice relaxation measurements. Besides, a peculiar motional transition in the ultralow frequency region was observed at 373 K for the “free” hydrated water from the rotating-frame NMR spin-lattice relaxation time measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local spin dynamics at low temperature in the slowly relaxing molecular chain [Dy(hfac)3(NIT(C6H4OPh))]: A μ{sup +} spin relaxation study

The spin dynamics of the molecular magnetic chain [Dy(hfac){sub 3}(NIT(C{sub 6}H{sub 4}OPh))] were investigated by means of the Muon Spin Relaxation (μ{sup +}SR) technique. This system consists of a magnetic lattice of alternating Dy(III) ions and radical spins, and exhibits single-chain-magnet behavior. The magnetic properties of [Dy(hfac){sub 3}(NIT(C{sub 6}H{sub 4}OPh))] have been studied by measuring the magnetization vs. temperature at different applied magnetic fields (H = 5, 3500, and 16500 Oe) and by performing μ{sup +}SR experiments vs. temperature in zero field and in a longitudinal applied magnetic field H = 3500 Oe. The muon asymmetry P(t) was fitted by the sum of three components, two stretched-exponential decays with fast and intermediate relaxation times, and a third slow exponential decay. The temperature dependence of the spin dynamics has been determined by analyzing the muon longitudinal relaxation rate λ{sub interm}(T), associated with the intermediate relaxing component. The experimental λ{sub interm}(T) data were fitted with a corrected phenomenological Bloembergen-Purcell-Pound law by using a distribution of thermally activated correlation times, which average to τ = τ{sub 0} exp(Δ/k{sub B}T), corresponding to a distribution of energy barriers Δ. The correlation times can be associated with the spin freezing that occurs when the system condenses in the ground state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Liquid crystal 8CB in random porous glass: NMR relaxometry study of molecular diffusion and director fluctuations

We present the measurements of the proton spin-lattice relaxation time T{sub 1} of liquid crystal 4-n-octyl-4{sup '}-cyanobiphenyl (8CB) confined into randomly oriented {approx}15 nm pores of untreated porous glass. In the low kilohertz range the spin-lattice relaxation rate in the nanoconfined 8CB is about ten times larger than in the bulk. We show that the increase is mainly due to molecular reorientations mediated by translational displacements (RMTD). In the paranematic phase the power law describing the RMTD dispersion, (T{sub 1}{sup -1}){sub RMTD}{proportional_to}{omega}{sup -p}, is well characterized by the exponent p=0.5{+-}0.06 and suggests an equipartition of diffusion modes with different wavelengths. The largest distance related to the decay of the orientational correlation function is about twice the diameter of the cavity. The situation is different in the nematic phase, where the orientational correlation is eventually lost at {approx}60 nm in the direction along the pore, a distance corresponding roughly to the length of a pore segment in the glassy matrix. The exponent p is between 0.65 and 0.9, depending on the temperature, which implies that in the nematic phase long wavelength modes are relatively more important--a consequence of the uniform director field along the pore. These observations are in agreement with the model of mutually independent pores with nematic director parallel to the pore axis in each segment. We point out that in strongly confined liquid crystals the proton NMR relaxometry does not provide the evidence of director fluctuations correlated over micrometer distances as was suggested earlier. The local translational diffusion of molecules within the cavities is found about as fast as in bulk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anion and Cation Size Effects on Viscoelasticity and Ion Transport of Imine Vitrimer Electrolytes

Vitrimers are a subclass of covalent adaptable networks where bond exchange occurs without breaking, thereby offering polymer materials with enhanced mechanical strength, thermal stability, and reprocessability compared to conventional electrolytes. Despite recent progress, we lack a complete understanding of the role of ions in controlling the physical and chemical properties of vitrimers. In this work, we study how different salts affect the viscoelasticity, morphology, and ionic conductivity of imine vitrimers. Our results show that addition of salt decreases relaxation times at elevated temperatures due to the catalytic effect of the cations, with smaller cations leading to faster relaxation. However, the activation energy for terminal relaxation increases with smaller cation size. This apparent discrepancy is attributed to the complex interplay among bond exchange kinetics, chain diffusion, and salt dissociation. Anions act as plasticizers by reducing the shear modulus, except lithium bromide. Ionic conductivity increases with larger anions due to smaller salt dissociation energies, whereas the cation type has a minor impact as polymer segmental dynamics dominate ionic transport. Imine-based vitrimers are reprocessable and recyclable, maintaining original mechanical properties and ionic conductivity after recovery. Mixed salt vitrimers exhibited tunable viscoelasticity and ionic conductivity intermediate to the analogous pure salt systems. Altogether, this work highlights the role of salt in the dynamic and conductive properties of imine vitrimers.

Anions↗

Optical and spin coherence of Er spin qubits in epitaxial cerium dioxide on silicon

Robust spin-photon interfaces with optical transitions in the telecommunication band are essential for quantum networking technologies. Erbium (Er) ions are the ideal candidate with environmentally protected transitions in telecom-C band. Finding the right technologically compatible host material to enable long-lived spins remains a major hurdle. We introduce a new platform based on Er ions in cerium dioxide (CeO 2 ) as a nearly-zero nuclear spin environment (0.04%) epitaxially grown on silicon, offering silicon compatibility for opto-electrical devices. Our studies focus on Er 3+ ions and show a narrow homogeneous linewidth of 440 kHz with an optical coherence time of 0.72 μs at 3.6 K. The reduced nuclear spin noise enables a slow spin-lattice relaxation with a spin relaxation time up to 2.5 ms and an electron spin coherence time of 0.66 μs (in the isolated ion limit) at 3.6 K. These findings highlight the potential of Er 3+ :CeO 2 platform for quantum networks applications.

Zhang, Jiefei↗

Electrical spin injection in 2D semiconductors and topological insulators

We have developed a theory of spin orientation by electric current in 2D semiconductors. It is shown that the spin depends on the relation between the energy and spin relaxation times and can vary by a factor of two for the limiting cases of fast and slow energy relaxation. For symmetrically-doped (110)-grown semiconductor quantum wells the effect of current-induced spin orientation is shown to exist due to random spatial variation of the Rashba spin-orbit splitting. We demonstrate that the spin depends strongly on the correlation length of this random spin-orbit field. We calculate the spin orientation degree in two-dimensional topological insulators. In high electric fields when the “streaming” regime is realized, the spin orientation degree weakly depends on the electric field and can reach values about 5%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equilibrium and Dynamics Properties of Poly(oxyethylene) Melts and Related Poly(alkylethers) from Simulations and Ab Initio Calculations

Molecular dynamics simulations of POE melts have been performed utilizing a potential force field parameterized to reproduce conformer energies and rotational energy barriers in dimethoxyethane as determined from ab initio electronic structure calculations. Chain conformations and dimensions of POE from the simulations were found to be in good agreement with predictions of a rotational isomeric state (RIS) model based upon the ab initio conformational. energies. The melt chains were found to be somewhat extended relative to chains at theta conditions. This effect will be discussed in light of neutron scattering experiments which indicate that POE chains are extended in the melt relative to theta solutions. The conformational characteristics of POE chains will also be compared with those of other poly (alkylethers), namely poly(oxymethylene), poly(oxytrimethylene) and poly(oxytetramethylene). Local conformational dynamics were found to be more rapid than in polymethylene. Calculated C-H vector correlation times were found to be in reasonable agreement with experimental values from C-13 NMR spin-lattice relaxation times. The influence of ionic salts on local conformations and dynamics will also be discussed.

Smith, Grant D.↗

Osmoregulation in Methanogens (and Other Interesting Organisms)

Our research has been aimed at (i) identifying, (ii) determining mode of regulation, and (iii) understanding how different classes of compatible solutes (also termed osmolytes) affect macromolecular stability in response to osmotic and thermal stress. For solutes we have identified (e.g., di-inositol-1,1’-phosphate (DIP)), we used NMR to elucidate biosynthetic pathways and then cloned suspected enzymes in the pathway to explore how they are regulated. Compatible solutes are thought to protect proteins from thermal and osmotic stresses by being excluded from the surface, allowing critical water molecules to interact with the protein. This implies there are no specific binding interactions between osmolytes and proteins. However, we and others have often observed very specific solute effects for proteins that suggest a more direct interaction between solute and protein is likely can occur. Measuring such a weak interaction is extremely difficult. We have developed a solution NMR method, high-resolution field cycling relaxometry, that can measure spin-lattice relaxation rates as a function of magnetic field from 11.7 (the field of a 500 MHz spectrometer) to 0.003 T. The methodology is ideal for nuclei in small molecules with moderately long relaxation times at high fields – phosphate groups (31P), enriched carbonyls (13C), or methyl groups (1H). The protein of interest is spin-labeled to introduce a large dipole on it that will dominate the relaxation of nuclei on any small molecules that bind transiently. The key is to measure relaxation below 1-2 T (and extract nuclei-spin label distances in the bound complex) where the small molecule relaxation will be dominated by dipolar mechanisms with a correlation time indicative of the large protein complex. Our explorations of an inositol monophosphatase (the last step in DIP generation) localized four discrete binding sides for the thermoprotectant α-glutamate. This is a novel approach, and while the work did not fully explain how this solute protected the IMPase from thermal denaturation, it did showcase a new and exciting method to monitor weak binding in biological systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-EF-BRA-00: MR Basics I

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI (f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-01: NMR and Proton Density MRI of the 1D Patient

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗