Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Evaluation of Single-Cell Cavities Made of Forged Ingot Niobium at Jefferson Lab

Currently, fine grain niobium (Nb) (grain size ~ 50 um) and large grain Nb (grain size of a few cm) are being used for the fabrication of superconducting radio frequency (SRF) cavities. Medium grain forged ingot with grain size of a few hundred um may be beneficial for cost-effectiveness as well as providing better performance for future SRF-based accelerators. Forged ingot Nb with medium grain size is a novel production method to obtain Nb discs used for the fabrication of superconducting radio frequency cavities. We have fabricated two 1.5 GHz single cell cavities made from forged Nb ingot with a residual resistivity ratio of ~100. The cavities were chemically and mechanically polished and heat-treated in the temperature range of 650-1000 C before the rf test. One of the cavities reached an accelerating gradient of 34 MV/m with a quality factor Q > 1e10, while the second cavity was limited at 14 MV/m, likely due to a weld defect at the equator.

Dhakal, P.↗

R&D Towards High Gradient CW SRF Cavities

This talk will discuss Fermilab’s recent progress in the surface engineering of superconducting radio-frequency (SRF) cavities geared toward producing simultaneously high quality factors and high accelerating gradients in cryomodules. We investigate possible microscopic mechanisms that drive improved performance by carrying out sequential RF tests on cavities subjected to low temperature baking. We compare performance evolution to observations made with material science techniques and find correlations with material parameters. We also discuss other key advancements that enable high gradient operation in cryomodules.

43 PARTICLE ACCELERATORS↗

Cavity Qualification and Production Update for SNS-PPU Cryomodules at Jefferson Lab

The Proton Power Upgrade (PPU) project at Oak Ridge National Lab’s Spallation Neutron Source (SNS) currently being constructed will double the proton beam power capability from 1.4 to 2.8 MW by adding seven cryomodules, each containing four six-cell high-beta (β = 0.81) superconducting radio frequency cavities. Research Instruments, located in Germany, built and processed the cavities at the vendor site, including electropolishing as the final active chemistry step. Twenty-eight cavities for seven cryomodules and an additional four cavities for a spare cryomodules were delivered to Jefferson Lab and first qualification tests were completed on all cavities as received from the vendor. The performance largely exceeded the requirements on quality factor and accelerating gradient. Here we present the status of initial cavity qualification tests, rework on unqualified cavities and final cavity qualification with helium vessel prior to installation in cryomodules. In addition, an update on cryomodule production is presented.

Dhakal, P.↗

Investigation of structural development in the two-step diffusion coating of Nb3Sn on niobium

The potential for higher operating temperatures and increased accelerating gradient has attracted SRF researchers to Nb3Sn coatings on niobium or other substrates for nearly 50 years. Its seeming simplicity has made the two-step tin vapor diffusion process the leading candidate, despite the almost universal finding of quality factor of coated cavities falling with increasing gradient. We have undertaken a fundamental materials study of the nucleation and deposition steps. Nucleation was accomplished within the usual parameter range: 400oC ? 500oC, 1-5 hours duration, 10 mg to 1 g SnCl2 and 1-3 g Sn. The resulting deposit consists of a low (< 10% ) coverage of micron-sized tin particles by SEM/EDS and a high (> 50%) coverage of few nm thick tin film by XPS and Scanning Auger Microscopy. The crystallography by EBSD and the topography of the substrate by AFM and SEM had no evident effect on the nucleation or the final film.

Eremeev, G.↗

Examining the Effects of Oxygen Doping on SRF Cavity Performance

Superconducting radiofrequency (SRF) cavities are resonators with extremely low surface resistance that enable accelerating cavities to have extremely high quality factors (Q₀). High (Q₀) decreases the capital required to keep accelerators cold by reducing power loss. The performance of SRF cavities is largely governed by the surface composition of the first 100 nm of the cavity surface. Impurities such as oxygen and nitrogen have been observed to yield high Q₀, but their precise roles are still being studied. Here, we compare the performance of cavities doped with nitrogen and oxygen in terms of fundamental material properties to understand how these impurities affect performance. This enables us to have further insight into the underlying mechanisms that enable these surface treatments to yield high Q₀ performance.

43 PARTICLE ACCELERATORS↗

Analysis of Low RRR SRF Cavities

Recent findings in the superconducting radio-frequency (SRF) community have shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. Success has been found in nitrogen-doping, diffusion of the native oxide into the niobium surface, and thin films of alternate superconductors atop a niobium bulk cavity. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of recent impurity-based improvements can be better understood and improved upon. Additionally, we performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of more impurities to the RF layer affects performance. We have found that low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. The results of this study have the potential to unlock a new understanding on SRF materials.

43 PARTICLE ACCELERATORS↗

Nb₃Sn Coating of a 2.6 GHz SRF Cavity by Sputter Deposition Technique

Nb₃Sn is of interest as a coating for SRF cavities due to its higher transition temperature Tc ~18.3 K and superheating field Hsh ~400 mT, both are twice that of Nb. Nb₃Sn coated cavities can achieve high-quality factors at 4 K and can replace the bulk Nb cavities operated at 2 K. A cylindrical magnetron sputtering system was built, commissioned, and used to deposit Nb₃Sn on the inner surface of a 2.6 GHz single-cell Nb cavity. With two identical cylindrical magnetrons, this system can coat a cavity with high symmetry and uniform thickness. Using Nb-Sn multilayer sequential sputtering followed by annealing at 950°C for 3 hours, polycrystalline Nb₃Sn films were first deposited at the equivalent positions of the cavity’s beam tubes and equator. The film’s composition, crystal structure, and morphology were characterized by energy dispersive spectroscopy, X-ray diffraction, and atomic force microscopy. The Tc of the films was measured by the four-point probe method and was 17.61 to 17.76 K. Based on these studies, ~1.2 micron thick Nb₃Sn was deposited inside a 2.6 GHz Nb cavity. We will discuss first results from samples and cavity coatings, and the status of the coating system.

43 PARTICLE ACCELERATORS↗

A reactive ferroelectric tuner for microphonics compensation

Jefferson Lab (JLab) is actively pursuing an extensive research program focused on developing advanced Nb₃Sn superconducting technology for particle accel-eration. Due to the brittle nature of Nb₃Sn coatings, a Ferroelectric Tuner (FRT) currently represents the most viable approach for microphonics compensation in these next-generation cavities. We suggest a novel, fast-responding FRT integrated directly into the main coupler, eliminating the need for an additional RF port. Leveraging a unique RF design based on a magic-T configuration, this advanced FRT will enable micro-phonics compensation in the ±30 Hz range without undesirable changes to the external quality factor.

Accelerator Physics↗

Analysis of vapor diffusion Nb$^{3}$Sn coating at Fermilab: Minimizing impurities using TOF-SIMS

Nb₃Sn demonstrates steady advancements nowadays offering reduced power cost in superconducting radio-frequency cavities due to its high critical temperature, quality factor, and achieved accelerating gradient. However, theoretical estimates of its radio-frequency parameters have not been achieved due to several potentially limiting mechanisms: tin spots, patchy regions, defects, thermal impedance, and impurities. While some of these limitations have been intensively studied, impurity analysis in Nb$_3$Sn coatings have received less attention. We report an investigation of impurities in several vapor-diffused Nb₃Sn coated samples using time-of-flight secondary ion mass spectroscopy (TOF-SIMS) and show allowable impurity levels in view of superconducting cavity performance. Challenges and lessons learned in maintaining clean Nb$_3$Sn coatings are also discussed.

Tagdulang, Nikki [Fermilab]↗

MAGNETIC HYGIENE CONTROL ON LCLS-II CRYOMODULES FABRICATED AT JLAB

Jefferson Lab (JLab) is in collaboration with Fermi Na-tional Accelerator Laboratory (Fermilab) to build 18 cryomodules to install at the SLAC National Accelerator Laboratory?s tunnel as part of the Linac Coherent Light Source upgrade project (LCLS-II). Each LCLS-II cry-omodule hosts 8 superconducting niobium cavities that adopt the nitrogen doping technique, which aims to en-hance the cavity quality factor Qo to reduce the consumption of liquid helium used to cool down the cavities. It is known that the Qo of niobium cavities is affected by cavity surface magnetic field. Traditionally, magnetic shields made of high magnetic permeability mu-metals are employed as a passive shielding of the ambient magnetic fluxes. During the LCLS-II cryomodule development, magnetic hygiene control that includes magnetic shielding and demagnetization of parts and the whole-machine is implemented. JLab and Fermilab worked closely on developing magnetic hygiene control procedures, identifying relevant tools, investigating causes of magnetization, magnetic field monitoring, etc. This paper focuses on JLab?s experiences with LCLS-II cryomodule magnetic hygiene control during its fabrication.

Cheng, Guangfeng↗

First Direct Imaging and Profiling TOF-SIMS Studies on Cutouts from Cavities Prepared by State-of-the-Art Treatments

Small amounts of interstitial impurities in the penetra-tion depth of superconducting radio frequency (SRF) cavities have a dramatic effect on the quality factors and maximum accelerating gradients. Here we report the first TOF-SIMS studies of cutouts from cavities prepared by all modern surface treatments, which allow a direct corre-lation of the impurity distribution with the observed cavity performance. Imaging capability of our instrument allows to avoid the possible issues associated with the ‘‘ghost’’ depth profiles appearing as a consequence of particulate surface contamination, which likely caused the inconclusive SIMS results on e.g. oxygen diffusion in the past.

43 PARTICLE ACCELERATORS↗

Magnetic Field Induced by Thermo Electric Current in LCLS-II Cryomodules

Seebeck effect of metals play an important role in cryomodule design. As cryomodule cools down from room temperature down to nominal cavity operating temperature, components in a cryomodule experiences different temperatures. Some components such as power couplers cross from room temperature to 2 K. Thermo electric current forms loops circulating through and around cavities. Such current loops will generate additional magnetic field that could be trapped into cavity wall during superconducting transition as well as during cavity quench. These trapped field can degrade cavity quality factor and increase heat load. Simple circuit model is proposed and compared to calculated trapped field during cryomodule tests.

43 PARTICLE ACCELERATORS↗

Investigating the Anomalous Frequency Variations Near $T_c$ of Nb SRF Cavities

We report recent studies on the anomalous frequency variations of 1.3 GHz Nb SRF cavities near the transition temperature Tc and use them to investigate the underlying physics of state-of-the-art surface treatments. One such feature, a dip in frequency, correlates directly with the quality factor at 16 MV/m and the anti-Q slope that arise in cavities with dilute concentrations of N interstitial in the RF layer achieved via N-doping and mid temperature baking. For N interstitial, we find that the dip magnitude and Tc follow exponential relationships with the electronic mean free path. We present the first observation of the frequency dip near Tc in a cavity baked at 200 C in-situ for 11 hours, which is concurrent with the anti-Q slope, and may be driven by oxygen diffused from the native oxide, thus suggesting the possibility of ‘‘O-doping.’’ We also investigate the conductivities of two cavities that display different resonant frequency behaviors near Tc and suggest that the anti-Q slope and frequency dip phenomena may occur in the presence of interstitial N or possibly O that inhibit the formation of proximity coupled Nb nano-hydrides.

43 PARTICLE ACCELERATORS↗

Cavity Production and Testing of the First C75 Cryomodule for CEBAF

The CEBAF cryomodule rework program was updated over the last few years to increase the energy gain of refurbished cryomodules to 75 MeV. The concept recycles the waveguide end-groups from original CEBAF cavities fabricated in the 1990s and replaces the five elliptical cells in each with a new optimized cell shape fabricated from large-grain, ingot Nb material. Eight cavities were fabricated at Research Instruments, Germany, and two cavities were built at Jefferson Lab. Each cavity was processed by electropolishing and tested at 2.07 K. The best eight cavities were assembled into ’cavity pairs’ and re-tested at 2.07 K, before assembly into the cryomodule. All but one cavity in the cryomodule were within 10% of the target accelerating gradient of 19 MV/m with a quality factor of 8·10⁹. The performance limitations were field emission and multipacting.

Ciovati, G.↗

A Method for In-Situ Q₀ Measurements of High-Quality SRF Resonators

Accelerator projects such as LCLS-II naturally require low-loss superconducting (SRF) cavities. Due to strong demand for improving intrinsic quality factor (Q₀), importance of accurate cavity characterization increases. We propose a method to measure Q₀ in situ for an SRF resonator installed in its cryogenic module and connected with a RF feed source via a fixed RF coupler. The method exploits measurements of a response for an SRF resonator fed by an amplitude-modulated signal. Such a signal can be synthesized as a beat-wave composed of two frequencies that are close to the resonant frequency. Analyzing the envelope of the reflected signal, one can find the difference in reflection for the chosen frequencies and use them to compute the intrinsic Q. We also develop the methodology to carry out measurements of Q₀ at the nominal cavity operating voltage. We verified our method in experiments with a room temperature copper resonator and with two SRF resonators including Fermilab’s 650 MHz cavity and JLab’s 1500 MHz cavity.

43 PARTICLE ACCELERATORS↗

Nb₃Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for energy recovery linac (ERL) applications. Nb₃Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities were fabricated at JLab and were proposed to be coated with Nb₃Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavi-ties needs to be improved to coat these cavities. This development advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb₃Sn coated twin axis cavities.

43 PARTICLE ACCELERATORS↗

SIMS Investigation of Furnace-Baked Nb

Results recently published by Ito et al. showed that "furnace baking" Nb SRF cavities after electropolishing yields high quality factors and anti-Q-slopes resembling that of N doped cavities. Small Nb samples were prepared following the recipe outlined by Ito. These samples were measured by SIMS to examine impurity contributions to the RF penetration layer. These diffusion profiles are modeled, and their consequences on RF properties discussed.

Lechner, E. M.↗

EVALUATION OF FLUX EXPULSION AND FLUX TRAPPING SENSITIVITY OF SRF CAVITIES FABRICATED FROM COLDWORK NB SHEET WITH SUCCESSIVE HEAT TREATMENT

The main source of RF losses leading to lower quality factor of SRF cavities is due to the residual magnetic flux trapped during cooldown. The loss due to flux trapping is more pronounced for cavities subjected to impurities doping. The flux trapping and its sensitivity to rf losses are related to several intrinsic and extrinsic phenomena. To elucidate the effect of recrystallization by high temperature heat treatment on the flux trapping sensitivity, we have fabricated two 1.3 GHz single cell cavities from cold-worked Nb sheets and compared with cavities made from standard fine-grain Nb. Flux expulsion ratio and flux trapping sensitivity were measured after successive high temperature heat treatments as well as after low temperature, 120 0C baking. The cavity made from cold worked Nb showed better performance after 800 0C/3hr heat treatment and similar behavior when heat treated with additional 900 0C and 1000 0C compared to standard fine-grain Nb cavity. In this contribution, we present the summary of flux expulsion, trapping sensitivity and results from RF tests at 2 K.

Khanal, Bashu↗