Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

MULTI-OMICS STUDY OF THE EFFECT OF REDOX-ACTIVE METALLOPORPHYRIN ON MURINE RETINA DURING SPACEFLIGHT

Astronauts returning from spaceflight have experienced eye problems, which may decrease retinal performance and lead to long-term effects on visual acuity. This study leverages the collected data from spaceflown murine retinas that were treated with redox-active metalloporphyrin (BuOE) to mitigate spaceflight-induced changes and respective ground controls. 10-week-old adult C57BL/6 male mice (n=5 in each of BuOE treated and saline control groups for spaceflown and ground control samples) were flown on Space-X 24 to the ISS national lab, kept in low earth orbit for 35 days and returned to Earth alive. Our multi-omics analysis of RNA-sequencing and reduced representation bisulfite sequencing (RRBS) data generated from subsequent murine retina tissues uncovered genes, pathways, and epigenetic modifications consistent with therapeutic potential of BuOE. From RNA-Seq analysis of spaceflown murine samples, the treatment group show differentially expressed genes relative to saline controls that reached significance (adjusted p-value < 0.05) and included genes Gpx3 and Crhbp, which are related to protection against cell oxidative damage and cellular response to organonitrogen compounds. Ranked fold-changes from the same contrast were used for gene set enrichment analysis, which showed biological processes reaching significance (adjusted p-value < 0.05) including glutathione metabolic processes and cellular response to xenobiotic stimulus. RRBS data of the spaceflown murine samples found 139 hyper or hypo differentially methylated sites spread across chromosomes 1-19 (20% promoters, 21% exons, 43% introns | 20 CpG islands, 7 CpG shores) with a 10% methylation difference (q-value < 0.05).The findings from this investigation have the potential to provide valuable insights into the molecular mechanisms underlying conditions like spaceflight associated neuro-ocular syndrome and assess the effectiveness of BuOE as a countermeasure for astronauts experiencing neuro-ophthalmic abnormalities, which can lead to long-term effects on visual acuity.

Biostatistics↗

Genomics Study of Effect of Redox-Active Metalloporphyrin on Murine Retina During Spaceflight

Astronauts returning from spaceflight have experienced eye problems, which may decrease retinal performance and lead to long-term effects on visual acuity. This study leverages the collected data from spaceflown murine retinas that were treated with redox-active metalloporphyrin (BuOE) to mitigate spaceflight-induced changes. 10-week-old adult C57BL/6 male mice (n=5 in each of BuOE treated and saline control groups) were flown on Space-X 24 to the ISS national lab, kept in low earth orbit for 35 days and returned to Earth alive. Our analysis of RNA-sequencing data generated from subsequent murine retina tissues uncovered genes, pathways, and epigenetic modifications consistent with therapeutic potential of BuOE. For spaceflown murine samples, the treatment group show differentially expressed genes relative to saline controls that reached significance (adjusted p-value < 0.05) and included genes Gpx3 and Crhbp, which are related to protection against cell oxidative damage and cellular response to organonitrogen compounds. Ranked fold-changes from the same contrast were used for gene set enrichment analysis, which showed biological processes reaching significance (adjusted p-value < 0.05) including glutathione metabolic processes and cellular response to xenobiotic stimulus. The findings from this investigation have the potential to provide valuable insights into the molecular mechanisms underlying conditions like spaceflight associated neuro-ocular syndrome and assess the effectiveness of BuOE as a countermeasure for astronauts experiencing neuro-ophthalmic abnormalities, which can lead to long-term effects on visual acuity.

Machine Learning↗

Multi-Omics Study of the Effect of Redox-Active Metalloporphyrin on Murine Retina During Spaceflight

Astronauts returning from spaceflight have experienced eye problems, which may decrease retinal performance and lead to long-term effects on visual acuity. This study leverages the collected data from spaceflown murine retinas that were treated with redox-active metalloporphyrin (BuOE) to mitigate spaceflight-induced changes and respective ground controls. 10-week-old adult C57BL/6 male mice (n=5 in each of BuOE treated and saline control groups for spaceflown and ground control samples) were flown on Space-X 24 to the ISS national lab, kept in low earth orbit for 35 days and returned to Earth alive. Our multi-omics analysis of RNA-sequencing and reduced representation bisulfite sequencing (RRBS) data generated from subsequent murine retina tissues uncovered genes, pathways, and epigenetic modifications consistent with therapeutic potential of BuOE. From RNA-Seq analysis of spaceflown murine samples, the treatment group show differentially expressed genes relative to saline controls that reached significance (adjusted p-value < 0.05) and included genes Gpx3 and Crhbp, which are related to protection against cell oxidative damage and cellular response to organonitrogen compounds. Ranked fold-changes from the same contrast were used for gene set enrichment analysis, which showed biological processes reaching significance (adjusted p-value < 0.05) including glutathione metabolic processes and cellular response to xenobiotic stimulus. RRBS data of the spaceflown murine samples found 139 hyper or hypo differentially methylated sites spread across chromosomes 1-19 (20% promoters, 21% exons, 43% introns | 20 CpG islands, 7 CpG shores) with a 10% methylation difference (q-value < 0.05).The findings from this investigation have the potential to provide valuable insights into the molecular mechanisms underlying conditions like spaceflight associated neuro-ocular syndrome and assess the effectiveness of BuOE as a countermeasure for astronauts experiencing neuro-ophthalmic abnormalities, which can lead to long-term effects on visual acuity.

Biostatistics↗

Assessments of Physiology and Cognition in Hybrid-Reality Environments (APACHE) – A VR “Sandbox” for Planetary Spacewalk Research

NASA is planning to return to the Moon in the mid-2020s as a steppingstone to Mars missions in the 2030s. Spacewalks, or extravehicular activities (EVAs), performed on the Moon and Mars will differ in a variety of ways from those that have been performed in decades past. NASA has identified multiple risks to human health and performance associated with a crewed mission to Mars, especially those associated with exploration EVAs which are expected to be a primary mission activity. Crew may be expected to conduct up to 24 hours of EVA per person per week, where the likelihood of injury and/or mental mistakes are increased compared to ground-based training or current microgravity EVAs and the consequences of which can be catastrophic. Current test environments for exploration EVA research and technology development are large, costly facilities that are limited in their availability or capabilities. Spacesuit testing in a reduced gravity environment such as NASA’s Neutral Buoyancy Laboratory, while a good representation of the crew’s physical workload during exploration EVAs, typically has small datasets and is difficult to integrate physiological sensors or other types of crew performance measures. Meanwhile, scientific field-based testing such as NASA’s Desert Research and Technology Studies offers an operationally relevant environment for exploration EVAs, particularly for cognitive workload, but is also limited by small datasets, lack of a pressurized spacesuit, and obtrusive measures. The limitations of current analogs for exploration EVAs identify a need for a new test environment that can approximate both the physical and cognitive demands associated with exploration EVAs to enable rapid, controlled, and repeatable evaluations of human health and performance risks of exploration missions. In response, the Human Physiology, Performance, Protection, and Operations Laboratory (H-3PO) at NASA Johnson Space Center has developed a hybrid reality exploration EVA analog named the Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE)[ to address these limitations using a combination of virtual, physical, and hybrid reality techniques. The APACHE facility resides at NASA Johnson Space Center and serves as a large “sandbox” for EVA research and simulation. At its center is a roughly 15x20ft space surrounded by a 14” tall sandbox partially filled with lunar regolith simulant to emulate the physical feeling of walking on a planetary surface and to allow for simulated geology operations. Nearby, a curved passive treadmill (Skillmill Connect, Technogym, Fairfield, NJ) and an omnidirectional treadmill (Infinadeck, Infinadeck, Rocklin, CA) are included to enable exploration of these large virtual environments while also imposing the physical demands, representative timelines, and cognitive burdens required to navigate and traverse these distances during exploration EVA. A 6DOF motion platform is used to simulate rover operations and supports various human performance evaluations and associated risks. Lastly, APACHE can support two extravehicular (EV) crewmembers working in tandem. A computer workstation is located nearby and also supports an intravehicular (IV) crewmember as part of a full mission simulation. The IV crewmember has direct video and audio communication with the EV crew in VR to provide operational and procedural support.

Human Performance↗

Carbon Structure Hazard Control

Carbon composite structures are widely used in virtually all advanced technology industries for a multitude of applications. The high strength-to-weight ratio and resistance to aggressive service environments make them highly desirable. Automotive, aerospace, and petroleum industries extensively use, and will continue to use, this enabling technology. As a result of this broad range of use, field and test personnel are increasingly exposed to hazards associated with these structures. No single published document exists to address the hazards and make recommendations for the hazard controls required for the different exposure possibilities from damaged structures including airborne fibers, fly, and dust. The potential for personnel exposure varies depending on the application or manipulation of the structure. The effect of exposure to carbon hazards is not limited to personnel, protection of electronics and mechanical equipment must be considered as well. The various exposure opportunities defined in this document include pre-manufacturing fly and dust, the cured structure, manufacturing/machining, post-event cleanup, and post-event test and/or evaluation. Hazard control is defined as it is applicable or applied for the specific exposure opportunity. The carbon exposure hazard includes fly, dust, fiber (cured/uncured), and matrix vapor/thermal decomposition products. By using the recommendations in this document, a high level of confidence can be assured for the protection of personnel and equipment.

Yoder, Tommy↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and deicing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP demonstration effort. The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kg. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft deicing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization.

Alternatives to Hexavalent Chromium, Controlled Re↗

Reuse International Space Station (ISS) Modules as Lunar Habitat

NASA currently projects ending the ISS mission in approximately 2016, due primarily to the expense of re-boost and re-supply. Lunar outposts are expected to be in place in the same timeframe. In support of these mission goals, a scheme to reuse ISS modules on the moon has been identified. These modules could function as pressurized volumes for human habitation in a lunar vacuum as they have done in low-earth orbit. The ISS hull is structurally capable of withstanding a lunar landing because there is no atmospheric turbulence or friction. A compelling reason to send ISS modules to the moon is their large mass; a large portion of the ISS would survive re-entry if allowed to de-orbit to Earth. ISS debris could pose a serious risk to people or structures on Earth unless a controlled re-entry is performed. If a propulsive unit is devised to be attached to the ISS and control re-entry, a propulsion system could be used to propel the modules to the moon and land them there. ISS modules on the lunar surface would not require re-boost. Radiation protection can be attained by burying the module in lunar regolith. Power and a heat removal system would be required for the lunar modules which would need little support structure other than the lunar surface. With planetary mass surrounding the module, heat flux may be controlled by conductance. The remaining requirement is the re-supply of life-support expendables. There are raw materials on the moon to supplement these vital resources. The lunar maria is known to contain approximately 40% oxygen by mass in inorganic mineral compounds. Chemical conversion of moon rocks to release gaseous oxygen is known science. Recycling and cleaning of air and water are currently planned to be accomplished with ISS Environmental Control & Life Support Systems (ECLSS). By developing a Propulsion and Landing Module (PLM) to dock to the Common Berthing Mechanism (CBM), several identical PLMs could be produced to rescue and transfer the ISS modules to the lunar surface, one by one. The propulsion does not need to be as swift as Apollo, nor would the modules need to be manned during transportation to the moon. The trajectory from low-Earth to lunar orbit would avoid or quickly pass through the Van Allen belts to minimize radiation exposure to electronics onboard. A landing technology similar to Apollo's could be utilized to land an ISS module on the moon. Since the mission will be unmanned, system redundancy could be minimized to keep the cost down. If the mission failed and a module crashed landed on the moon, the risk of debris landing on Earth would be avoided and the raw materials could be used in future lunar missions.

Miernik, Janie↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and de-icing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP (the Dept. of Defense's (DoD's) Environmental Security Technology Certification Program) demonstration effort.The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kilograms. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow-on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft de-icing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization. Abstract for Appendix A. Toxicology Report: Corrosion controls a significant problem for military equipment. Many surface treatment materials currently in use on items of military or aerospace materiel contain chromium (VI) as a component, a source of significant human health and environmental hazard. The formulation under evaluation contains no chromium. Most of the proposed components are low to moderate toxicity and are not a significant concern. Two of the formulation components are associated with some cancer hazard - 2-mercaptobenzothiazole and formaldehyde, but both find widespread use in industry and additional investigation is not required for this project.

Calle, Luz Marina↗

Is there a role for nonsedating antihistamines in motion sickness? Fallout from space research may soon benefit your patients

The rotating chair test, a novel research technique for simulating motion sickness, is used to study the effect of nonsedating oral antihistamines in preventing or forestalling motion sickness. After receiving terfenadine, astemizole, doxepin, or placebo, four groups of male volunteers were rotated at accelerating speed, and they made head movements out of the axis of rotation until they perceived that vomiting would occur if additional head movements were made. Those pretreated with doxepin or terfenadine experienced a statistically significant prophylactic effect, as measured by increased tolerance to Coriolis stimulation. This suggests that selective peripheral H1 antihistamine action may protect against motion sickness.

Clinical Trial↗

Balloon-borne package temperature controller

Simple, inexpensive, lightweight enclosure traps upward long wave radiation of earth while reflecting harsh solar radiation in upper atmosphere. It warms enclosed instruments in cold regions and protects them from overheating during the day. Device can be attached to balloon system without any changes in experimental design.

Schach, M.↗

Radio frequency interference protection of communications between the Deep Space Network and deep space flight projects

The increasing density of electrical and electronic circuits in Deep Space Station systems for computation, control, and numerous related functions has combined with the extension of system performance requirements calling for higher speed circuitry along with broader bandwidths. This has progressively increased the number of potential sources of radio frequency interference inside the stations. Also, the extension of spectrum usage both in power and frequency as well as the greater density of usage at all frequencies for national and international satellite communications, space research, Earth resource operations and defense, and particularly the huge expansion of airborne electronic warfare and electronic countermeasures operations in the Mojave area have greatly increased the potential number and severity of radio frequency interference incidents. The various facets of this problem and the efforts to eliminate or minimize the impact of interference on Deep Space Network support of deep space flight projects are described.

Johnston, D. W. H.↗

Shocking Results on the Adverse Effects of CO2 Exposures

Carbon dioxide (CO2) is released in large quantities from humans while they live and work in spacecraft or work outside the spacecraft during extravehicular activity (EVA). Removal of this anthropogenic pollutant requires major resources, and these resources increase dramatically as the levels of CO2 set to protect human health and performance are reduced. The current Spacecraft Maximum Allowable Concentration of CO2 aboard the ISS is 0.7% or 5.3 mmHg; however, according to Chits (mission action requests), NASA and its international partners have agreed to control CO2 levels to less than 4 mmHg. In the meantime, retrospective investigations attempting to associate crew symptoms with elevated CO2 levels over the life if the International Space Station (ISS) are underway to determine if this level is sufficient to protect against health and performance decrements. Anecdotal reports suggest that crewmembers are not able to perform complex tasks as readily in spaceflight as they were able during ground-based training. While physiological effects of CO2 have been studied for many decades, it is only recently that the effects of CO2 on higher reasoning capabilities have been studied. The initial results are shocking. For example, one study published in the respected journal Environmental Health Perspectives showed obvious adverse effects of CO2 exposures on higher reasoning at 1.9 mmHg. The implications and limitations of this study are paramount in determining future CO2 SMACs for human spaceflight, both aboard the ISS and in exploration-class missions. Key Words: carbon dioxide, spacecraft, air quality, toxic effects

James, John T.↗

Association Between Vascular Density and Loss of Protective RAS During Early NPDR by Fractal Dimension

Purpose: Our hypothesis predicts that blood vessels within the retina increase in density during early-stage nonproliferative diabetic retinopathy (NPDR), based on previous results of a small retrospective study. For the current prospective study, the remodeling of arteries and veins during progression of early NPDR is assessed by a repertoire of parameters that includes the fractal dimension (D(sub f) ). In complex structures such as branching vascular trees, D(sub f) is a sensitive measure of space-filing capacity. The renin-angiotensin system (RAS) is implicated in DR pathogenesis and the function of circulating angiogenic cells (CACs), a critical bone marrow-derived population instrumental in vascular repair. Methods: Arterial and venous branching patterns were extracted from images of 6 normal controls and 3 early NPDR subjects (2 moderate, 1 mild) acquired by Heidelberg Spectralis (Registered Trademark) OCT following fluorescein angiography (FA). The vascular branching patterns were analyzed by NASAs VESsel GENeration Analysis (VESGEN) software, in which skeletonized representations were generated automatically to yield D(sub f) by the box-counting method. For binary 2D images, D(sub f) varies between limiting Euclidean dimensions of 1 and 2. Peripheral blood of diabetics and controls was collected for CD34+ CAC isolation. The gene expression of RAS in CACs was assessed by qPCR for Mas receptor to Ang-(1-7). The vasoreparative function of the CACs was measured by migration ability toward CXCL12 (SDF-1). Results: By D(sub f), venous and arterial densities were 1.370 +/- 0.006 and 1.329 +/- 0.016 for early NPDR, compared to 1.318 +/- 0.012 and 1.320 +/- 0.036 for control. The space filling capacity in early NPDR measured by D(sub f), a sensitive parameter, therefore demonstrated a pronounced increase for veins, but not for arteries. Mas receptor mRNA in CACs was increased in diabetics without DR but reduced with onset of NPDR, indicating possible loss of compensation of protective RAS during early DR. Migratory dysfunction of CD34+ cells was further associated with DR. Conclusions: As assessed by the fractal dimension in our preliminary study, the space-filling capacity of veins, but not arteries, was greater in early NPDR than in control. Larger patient populations will be examined as we complete our ongoing longitudinal study. Results further suggest the protective RAS axis within diabetic CACs is lost early in DR and is associated with increased vascular remodeling as evidenced by VESGEN analysis.

vascular↗

Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride

Hydrogen fluoride (HF) is a primary evolved combustion product of fluorinated and perfluorinated hydrocarbons. HF is produced during combustion by the presence of impurities and hydrogen- containing polymers including polyimides. This effect is especially dangerous in closed occupied volumes like spacecraft and submarines. In these systems, combinations of perfluorinated hydrocarbons and polyimides are used for insulating wiring. HF is both highly toxic and short-lived in closed environments due to its reactivity. The high reactivity also makes HF sampling problematic. An infrared optical sensor can detect promptly evolving HF with minimal sampling requirements, while providing both high sensitivity and high specificity. A rugged optical path length enhancement architecture enables both high HF sensitivity and rapid environmental sampling with minimal gaseous contact with the low-reactivity sensor surfaces. The inert optical sample cell, combined with infrared semiconductor lasers, is joined with an analog and digital electronic control architecture that allows for ruggedness and compactness. The combination provides both portability and battery operation on a simple camcorder battery for up to eight hours. Optical detection of gaseous HF is confounded by the need for rapid sampling with minimal contact between the sensor and the environmental sample. A sensor is required that must simultaneously provide the required sub-parts-permillion detection limits, but with the high specificity and selectivity expected of optical absorption techniques. It should also be rugged and compact for compatibility with operation onboard spacecraft and submarines. A new optical cell has been developed for which environmental sampling is accomplished by simply traversing the few mm-thick cell walls into an open volume where the measurement is made. A small, low-power fan or vacuum pump may be used to push or pull the gaseous sample into the sample volume for a response time of a few seconds. The optical cell simultaneously provides for an enhanced optical interaction path length between the environmental sample and the infrared laser. Further, the optical cell itself is comprised of inert materials that render it immune to attack by HF. In some cases, the sensor may be configured so that the optoelectronic devices themselves are protected and isolated from HF by the optical cell. The optical sample cell is combined with custom-developed analog and digital control electronics that provide rugged, compact operation on a platform that can run on a camcorder battery. The sensor is inert with respect to acidic gases like HF, while providing the required sensitivity, selectivity, and response time. Certain types of combustion events evolve copious amounts of HF, very little of other gases typically associated with combustion (e.g., carbon monoxide), and very low levels of aerosols and particulates (which confound traditional smoke detectors). The new sensor platform could warn occupants early enough to take the necessary countermeasures.

Pilgrim, Jeffrey↗

Fault tree applications within the safety program of Idaho Nuclear Corporation

Computerized fault tree analyses are used to obtain both qualitative and quantitative information about the safety and reliability of an electrical control system that shuts the reactor down when certain safety criteria are exceeded, in the design of a nuclear plant protection system, and in an investigation of a backup emergency system for reactor shutdown. The fault tree yields the modes by which the system failure or accident will occur, the most critical failure or accident causing areas, detailed failure probabilities, and the response of safety or reliability to design modifications and maintenance schemes.

W. E. Vesely↗

Solid state electro-optic color filter and iris

A pair of solid state electro-optic filters (SSEF) in a binocular holder were designed and fabricated for evaluation of field sequential stereo TV applications. The electronic circuitry for use with the stereo goggles was designed and fabricated, requiring only an external video input. A polarizing screen suitable for attachment to various size TV monitors for use in conjunction with the stereo goggles was designed and fabricated. An improved engineering model 2 filter was fabricated using the bonded holder technique developed previously and integrated to a GCTA color TV camera. An engineering model color filter was fabricated and assembled using PLZT control elements. In addition, a ruggedized holder assembly was designed, fabricated and tested. This assembly provides electrical contacts, high voltage protection, and support for the fragile PLZT disk, and also permits mounting and optical alignment of the associated polarizers.

Source record↗

Low-power portable geophysical data acquisition system and its use in geomagnetic measurements

A low-power portable data acquisition system presently in use for geomagnetic measurements is described. The system is composed of a data-processing system containing a low-power microprocessor, a 9-track digital tape recorder, and a rechargeable battery pack. The magnetometer is a low-power three axis fluxgate design. Under program control the data processing system keeps track of time of day and date, samples three analog magnetometer outputs at intervals of either 0.4 or 2 s, digitizes the data to 15-bit resolution, and, depending upon relative magnetic activity, decides upon data compression to increase the tape storage capacity. It also monitors and records internal voltages and provides self-checking functions which may be monitored through a visual readout on the control panel. The system is mounted in a rugged, weather-tight carrying case suitable for use outdoors with minimal protection. The system, including magnetometer, uses 1.6-W power and can store 5.7 Mbytes of data.

Medford, L. V.↗