Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Analysis of the Sludge Batch 9 (Macrobatch 11) DWPF Pour Stream Glass Sample Collected During the Nitric-Glycolic Acid Flowsheet Transition

A pour stream (PS) sample taken near the end of processing of Sludge Batch 9 (SB9, Macrobatch 11) during the transition to the nitric-glycolic acid (NGA) flowsheet was analyzed by the Savannah River National Laboratory (SRNL). The SB9 NGA PS sample was taken on 12/18/2022 during Melter Feed Batch 823 associated with glass canister S04773 and was transferred to SRNL in Primary Container PC0139 in February 2023.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of higher harmonic blade feathering for helicopter vibration reduction

Higher harmonic blade feathering for helicopter vibration reduction is considered. Recent wind tunnel tests confirmed the effectiveness of higher harmonic control in reducing articulated rotor vibratory hub loads. Several predictive analyses developed in support of the NASA program were shown to be capable of calculating single harmonic control inputs required to minimize a single 4P hub response. In addition, a multiple-input, multiple-output harmonic control predictive analysis was developed. All techniques developed thus far obtain a solution by extracting empirical transfer functions from sampled data. Algorithm data sampling and processing requirements are minimal to encourage adaptive control system application of such techniques in a flight environment.

Powers, R. W.↗

Capillary electrophoresis: Imaging of electroosmotic and pressure driven flow profiles in fused silica capillaries

This study is a continuation of the summer of 1994 NASA/ASEE Summer Faculty Fellowship Program. This effort is a portion of the ongoing work by the Biophysics Branch of the Marshall Space Flight Center. The work has focused recently on the separation of macromolecules using capillary electrophoresis (CE). Two primary goals were established for the effort this summer. First, we wanted to use capillary electrophoresis to study the electrohydrodynamics of a sample stream. Secondly, there was a need to develop a methodology for using CE for separation of DNA molecules of various sizes. In order to achieve these goals we needed to establish a procedure for detection of a sample plug under the influence of an electric field Detection of the sample with the microscope and image analysis system would be helpful in studying the electrohydrodynamics of this stream under load. Videotaping this process under the influence of an electric field in real time would also be useful. Imaging and photography of the sample/background electrolyte interface would be vital to this study. Finally, detection and imaging of electroosmotic flow and pressure driven flow must be accomplished.

Williams, George O., Jr.↗

RESOLVE OVEN Field Demonstration Unit for Lunar Resource Extraction

The Oxygen and Volatile Extraction Node (OVEN) is a subsystem within the Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) project. The purpose of the OVEN subsystem is to release volatiles from lunar regolith and extract oxygen by means of a hydrogen reduction reaction. The complete process includes receiving, weighing, sealing, heating, and disposing of core sample segments while transferring all gaseous contents to the Lunar Advanced Volatile Analysis (LAVA) subsystem. This document will discuss the design and performance of the OVEN Field Demonstration Unit (FDU), which participated in the 2012 RESOLVE field demonstration.

Paz, Aaron↗

Cryo-Temp Data Logger

Biological experiments on the ISS are frequently frozen at ultra-low temperatures on orbit prior to return to Earth for analysis. Recording temperatures during the freezing process, and subsequent handling to the point of post-flight processing, can provide important information of sample integrity to the scientist. The MadgeTech Cryo-Temp Data Logger has been modified for space flight applications by the Payload Development Team at Kennedy Space Center. This ultra-low temperature data logger is rated for temperatures from -86 C to +35 C with 0.1 C resolution and +/-1 C accuracy, but has been successfully tested at Kennedy Space Centers Cryogenic Lab down to -100 C. The logger provides date and time stamped temperature recordings and can be set with logging intervals from 5 seconds up to 30 minutes using the MadgeTech Data Logger Software. Data can be recorded, depending on logging interval, for greater than 90 days. The Cryo-Temp Data logger will first be flown on Space X-12 in the BRIC-Petri Dish Fixation Unit (PDFU) canister hardware, recording temperature data for a Space Life and Physical Sciences (SLPS) flight experiment. The modified Cryo-Temp Data Logger is small in size (Figure 1) and is the ideal temperature monitoring solution for any application involving independent temperature data logging.

Logger↗

Enabling Biological Discovery Through Biospecimen Sharing: The Nasa Biological Institutional Scientific Collection

Understanding biological impacts from spaceflight hazards and the subsequent development of countermeasures are a high priority to enable humanity to venture back to the Moon, and then to Mars and beyond. Experiments have been conducted with model organisms flown to space and analogous investigations terrestrially, to identify biological mechanistic impacts from spaceflight hazards and to develop mitigation countermeasures, thus contributing towards basic and applied science goals. However, sending organisms into space is a costly endeavor. To maximize scientific return, all biospecimens not required by spaceflight-relevant Principal Investigators are harvested, preserved, and archived in the NASA Biological Institutional Scientific Collection (NBISC). Biospecimens are collected and preserved according to well-established standard operating procedures to maintain scientific quality and are available on-request by the international scientific community. NBISC currently stores over 32,000 biospecimens from Shuttle, International Space Station, and ground-based space analog investigations. Tissue sharing has resulted in at least 33 publications since 2011 and 51 requests since 2016. Many requests for NBISC biospecimens come from first-time investigators who subsequently submit grants as their point-of-entry into the field of spaceflight biology and health. The NBISC biorepository is part of the NASA ‘Open Science for Life in Space’ collaborative group of projects, which includes NASA Genelab, the Space Biology Program’s Biospecimen Sharing Program, Physical Sciences Informatics, and the Ames Life Sciences Data Archive. NBISC biospecimens have been awarded to NASA Genelab, who then generated various open access science ‘omics datasets through the GeneLab Sample Processing laboratory, with resulting data widely used for biological study. Other NBISC biospecimen awards have led to studies on fecal microbiome analysis, DNA damage analysis using single-cell DNA sequencing, enzymatic-pathway identification involved in spaceflight muscle atrophy, and characterization of ocular morphological changes. Of note, NBISC is expanded to include a new Space Microbial Culture Collection (SMCC) for the collection, identification, documentation, long-term preservation, and distribution of space-related microbial isolates.

Biospecimens↗

Material Property Estimation in Thin Battery Components Using Guided Wave Measurement, Experimental Dispersion Curve Extraction and Finite Element Modeling

At NASA, we are investigating nondestructive evaluation (NDE) and structural health monitoring (SHM) techniques to detect precursors of thermal runaway failure in lithium metal based lithium ion batteries (LIB). The approach is centered on computational simulation models to guide inspection and aid in interpretation of results. Since lithium metal LIBs have combinations of solid and fluid-filled porous materials, obtaining accurate material properties is both challenging and critical for successful simulation of battery inspection. To this end, we investigated a multi-verification approach for material characterization of thin battery components. First, a laser Doppler vibrometer (LDV) was used to measure guided wave fields in thin (microns-thick) battery components subject to broadband excitation. The time-space wavefield data was converted to frequency-wave number data to extract guided wave dispersion curves. A data visualization and post processing graphics user interface (GUI) was developed at NASA to aid the data exploration and analysis. Due to the thinness of the samples, low frequency-thickness-product plate wave approximations allowed for the calculation of closed-form solutions for material elastic property estimation. These approximations were then verified by calculating the Lamb wave solutions using the previously obtained material properties. Finally, the estimated elastic material properties were implemented in a COMSOL simulation model, and dispersion curves were extracted from simulation results. The dispersion curves and derived material properties were then compared to the analysis results from the experimental data. These comparisons informed on the accuracy of the measured material properties and helped demonstrate the accuracy of the finite element analysis (FEA) computational models. This assessment will prove vital when we start simulating more complex multi-layer components and poroelastic media. This paper gives a brief background of the problem space, outlines the workflow for data analysis and verification, shows results from the workflow, and gives an overview of future plans for simulation of lithium metal LIB inspection.

Peter Juarez↗

Remote Diagnosis and Operational Response to an In-Flight Failure of the Drill Feed Mechanism Onboard the Mars Science Laboratory Rover

On November 30th, 2016 (Sol 1536 of the mission), the Mars Science Laboratory (MSL) flight operations team commanded the Curiosity rover to drill into a Martian rock to acquire the mission’s 16th rock powder sample. The drilling operation was halted when the drill feed mechanism unexpectedly stalled shortly after disengaging its magnetically-actuated friction brake at the start of a long move to extend the drill bit into contact with the target rock. The drilling campaign was put on hold and later abandoned as diagnostic experimentation revealed a tendency for the actuator to transition in and out of a high-drag state in which the mechanism could not actuate. In the subsequent months, the team conducted a variety of in-flight and ground-based investigations to determine root cause and identify mitigation strategies for continued operation. Mechanism reliability continued to degrade and by June 2017, it became clear that the mechanism could not be relied upon to support drilling operations. The team succeeded in fully extending the feed, enabling the development of new sampling techniques that would not rely on the feed mechanism. The first feed-extended drilling sample was successfully collected on Sol 2057, 521 sols after the initial feed stall. This paper discusses the anomaly investigation process, failure analysis, and feed mechanism operation mitigation strategies. It concludes with key lessons learned about mechanism design, mission architecture, and operational best practices.

Lin, Megan Richardson↗

STARscan: Spatial Targeting and Alignment Rig for Scanning

The Spatial Targeting and Alignment Rig for Scanning (STARScan) is a 3D photogrammetry system developed at NASA Ames Research Center to address bottlenecks in pre/post-test scanning of arcjet test articles. It reduces scan time from 15 minutes with handheld laser scanners to under 2 minutes, while maintaining high accuracy (±0.2-0.5 mm). STARScan integrates an array of cameras, a 3D-printed rack, turntable, and LED light panels, all controlled via a user-friendly graphical user interface (GUI). The system offers tools for scan visualization, mesh analysis, and data export, automating tasks such as alignment of pre/post-test scans, material recession measurements, surface roughness assessment, and curvature analysis. By integrating scanning, imaging, and post-processing into one application, STARScan significantly improves efficiency in scanning and analyzing arcjet test samples.

Ablation↗

Analysis of Surface Chemistry and Detector Performance of Chemically Process CdZnTe crystals

The goal is to produce non-conductive smooth surfaces for fabricating low-noise and high-efficiency CdZnTe devices for gamma spectroscopy. Sample preparation and results are discussed. The researachers demonstrated various bulk defects (e.g., dislocations and sub-grain boundaries) and surface defects, and examined their effects on the performance of detectors. A comparison study was made between two chemical etchants to produce non-conductive smooth surfaces. A mixture of bromine and hydrogen peroxide proved more effective than conventional bromine etchant. Both energy resolution and detection efficiency of CZT planar detectors were noticeably increased after processing the detector crystals using improved chemical etchant and processing methods.

36 MATERIALS SCIENCE↗

Sealed magic angle spinning nuclear magnetic resonance probe and process for spectroscopy of hazardous samples

A magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) probe is described that includes double containment enclosures configured to seal and contain hazardous samples for analysis. The probe is of a modular design that ensures containment of hazardous samples during sample analysis while preserving spin speeds for superior NMR performance and convenience of operation.

36 MATERIALS SCIENCE↗

Measurement of ( n, γ ) cross section of 90 Zr [Abstract]

The isotopes of Zr with A = [90, 91, 92, 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications such as nuclear reactors. One of the attractive qualities of naturally occurring Zr isotopes is that they have a low σγ/σt ratio at most neutron energies, such that they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σγ, of Zr isotopes. The ENDF/B-VIII.0 library has a relative uncertainty of approximately 10-20% for incident neutron energies < 0.1 MeV, and uncertainty greater than 20% for energies > 0.1 MeV for the majority of natural Zr isotopes. This motivated the Nuclear Criticality Safety Program (NCSP) to embark on a campaign to accurately measure and evaluate these isotopes of Zr. Here we will show energy-dependent neutron capture cross section measurements for the first enriched sample to be measured: 90 Zr. The measurements of isotopically enriched samples are being carried out at the Geel Electron Linear Accelerator (GELINA) facility of the Joint Research Center - Geel (JRC-Geel) of the European Union. As isotopic enrichment is a costly process we are careful not to activate any of the samples, as this may hinder future radiation-sensitive measurements. The activation analysis is presented in a report by Brown et al.. Once we were satisfied that the Zr samples would not be activated by the measurements, the 90 Zr sample was fabricated at Oak Ridge National Laboratory (ORNL) and shipped to GELINA. The dimensions of the cylindrical sample are approximately 0.12 cm thick and a radius of 2.5 cm. Since 90 Zr is not chemically reactive to air, bare metallic samples were employed. The sample was measured at a flight path (FP) length of 60 m, using four C 6 D 6 detectors on FP14. The final paper will include experimental details and measured cross section data for 90 Zr compared to current evaluated nuclear data libraries.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of a contaminated facility and associated soils in support of D and D and subsequent soil remediation - 15292

Before starting any D and D field work at a United States Department of Energy (DOE) facility such as the Savannah River Site (SRS), it is recommended that a complete review and understanding of the full nature and extent of any contamination located in or previously associated with that facility is known. An integral aspect of this review and research entails a complete characterization of that facility, including, but not limited to, Toxic Substances Control Act (TSCA) limits for Polychlorinated Biphenyl (PCB), radiological, Resource Conservation and Recovery Act of 1976 (RCRA) and other hazardous chemicals, etc. A thorough characterization of a facility and its underlying soils supports: - establishment of safe working conditions to protect human health and environment - Deactivation and Decommissioning (D and D) methodology - cost estimates to support future budget planning for D and D and soil cleanup A prime example of this is documented in the characterization of the 690-N, Process Heat Exchanger Repair Facility that had a history of PCB and radioactive contamination. Characterization of 690-N included the sampling and analysis of concrete and underlying soils for radiological, PCB and hazardous contaminants. In addition, a sump, the walls of the facility, expansion joint material and the metal base of a drill press were characterized. Results of this comprehensive characterization of the 690-N Building are provided in a detailed report. Analytical results indicate minimal radiological, PCB, or RCRA hazardous contamination is present in the concrete floor slab (industrial exposure levels) and on the steel hut walls. Soils below the concrete floor slab show only trace amounts of radiological contamination and are well below TSCA and RCRA limits. Subsequent decommissioning/demolition activities can be performed safely without harming people or the environment, and cost estimates to perform building demolition can be developed for future budget planning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Innovative Insight into Performance Degradation of NCM111 Cathode Induced by Suspension of Operation

The lifespan of lithium-ion batteries varies enormously from fundamental study to practical applications. This big difference has been typically ascribed to the high degree of uncertainty in unpredictable and complicated operation conditions in real-life applications. Here, in this paper, we report that the pause of the charging–discharging process, which is frequently operated in practice but rarely studied in academics, is an important reason for the performance degradation of the NCM111 cathode. It is found that the pause during cycling could trigger a remarkable drop in capacity, giving rise to ~30% more capacity decay compared with the continuously cycled sample. In situ synchrotron X-ray diffraction analysis reveals that the harmful H1–H2 phase transition, which typically appears in the initial cycle but disappears in subsequent cycles, is reactivated by the pausing process. The anisotropic lattice strains that occur during the H1–H2 transition result in mechanical fractures that terminate with an inert NiO-type rock-salt phase on the surface of particles. The present study indicates that the discontinuous usage of rechargeable batteries is also a key factor for cycle life, which might provide a distinct perspective on the performance decay in practical applications.

25 ENERGY STORAGE↗

Data-Driven Optimization of the Processing Window for 316H Components Fabricated Using Laser Powder Bed Fusion

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development and deployment of advanced materials and components fabricated via additive manufacturing with a specific focus on laser powder bed fusion (LPBF). As an initial case study, the program has selected 316H stainless steel (SS) as an initial material around which to develop a code case development strategy. This strategy involves two parallel approaches: (1) an equivalency approach whereby round-robin testing across multiple collaborating laboratories demonstrates repeatability in processing and direct comparisons with conventional wrought 316H material and (2) a revolutionary approach to code qualification combining in situ data collection and high-fidelity modeling to capture, predict, and bound the performance of LPBF 316HSS components. As part of this campaign, this work package has initiated an extensive process optimization campaign across three laboratories, each printing variations of LPBF 316HSS using three different LPBF units (Concept Laser, EOS, and Renishaw). In FY23, ORNL has focused on unique experimental designs spanning wide ranges in energy inputs and turning knobs such as scan speed, laser power, hatch spacing, layer thickness, spot size, scan rotation, and more. On the Concept Laser M2, 72 different combinations of processing variables were investigated with duplicate samples and different powder compositions. In total, 252 samples were printed with combined in situ sensing data. A parallel design of experiments was conducted on the Renishaw AM400 with an additional 390 printed specimens for analysis. All 642 miniature specimens, each with unique features included in each print to capture geometry-related heterogeneity, were subjected to high-throughput x-ray computed tomography (XCT) analysis to enable the downselection of specific processing parameters of interest. Then, using electrical discharge machining (EDM), miniature tensile specimens were extracted for mechanical testing and microscopy investigations. From the analysis performed in FY23, it was found that powder composition drastically affects the resulting microstructure and mechanical performance of 316SS. Specifically, changing from 316L to 316HSS powder results in a wide range of grain sizes with varying degrees of preferred grain orientation, which increases as a function of energy density. It was also found that due to stored heat in thin fin–type features, large microstructural differences can be seen within one part printed with one set of processing parameters. These variations in microstructure features, including grain size, the nanoscale dislocation structure, and grain texture, will all affect the irradiation performance and high-temperature mechanical performance of LPBF 316HSS parts. Two sets of concept laser processing parameters, spanning both refined and columnar grain structures, were scaled to print larger 316H builds for campaign testing (high-temperature creep and irradiation). In addition, at least two optimized processing parameter sets were identified for the Renishaw AM400 for round-robin testing in FY24 with Argonne National Laboratory. Future work includes printing samples using identical parameters identified by partner institutions, providing material for corrosion and high-temperature mechanical testing, and continuing evaluations of heterogeneity in larger printed parts.

36 MATERIALS SCIENCE↗

Data-Driven Optimization of the Processing Window for 316H Components Fabricated Using Laser Powder Bed Fusion

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development and deployment of advanced materials and components fabricated via additive manufacturing with a specific focus on laser powder bed fusion (LPBF). As an initial case study, the program has selected 316H stainless steel (SS) as an initial material around which to develop a code case development strategy. This strategy involves two parallel approaches: (1) an equivalency approach whereby round-robin testing across multiple collaborating laboratories demonstrates repeatability in processing and direct comparisons with conventional wrought 316H material and (2) a revolutionary approach to code qualification combining in situ data collection and high-fidelity modeling to capture, predict, and bound the performance of LPBF 316HSS components. As part of this campaign, this work package has initiated an extensive process optimization campaign across three laboratories, each printing variations of LPBF 316HSS using three different LPBF units (Concept Laser, EOS, and Renishaw). In FY23, ORNL has focused on unique experimental designs spanning wide ranges in energy inputs and turning knobs such as scan speed, laser power, hatch spacing, layer thickness, spot size, scan rotation, and more. On the Concept Laser M2, 72 different combinations of processing variables were investigated with duplicate samples and different powder compositions. In total, 252 samples were printed with combined in situ sensing data. A parallel design of experiments was conducted on the Renishaw AM400 with an additional 390 printed specimens for analysis. All 642 miniature specimens, each with unique features included in each print to capture geometry-related heterogeneity, were subjected to high-throughput x-ray computed tomography (XCT) analysis to enable the downselection of specific processing parameters of interest. Then, using electrical discharge machining (EDM), miniature tensile specimens were extracted for mechanical testing and microscopy investigations. From the analysis performed in FY23, it was found that powder composition drastically affects the resulting microstructure and mechanical performance of 316SS. Specifically, changing from 316L to 316HSS powder results in a wide range of grain sizes with varying degrees of preferred grain orientation, which increases as a function of energy density. It was also found that due to stored heat in thin fin–type features, large microstructural differences can be seen within one part printed with one set of processing parameters. These variations in microstructure features, including grain size, the nanoscale dislocation structure, and grain texture, will all affect the irradiation performance and high-temperature mechanical performance of LPBF 316HSS parts. Two sets of concept laser processing parameters, spanning both refined and columnar grain structures, were scaled to print larger 316H builds for campaign testing (high-temperature creep and irradiation). In addition, at least two optimized processing parameter sets were identified for the Renishaw AM400 for round-robin testing in FY24 with Argonne National Laboratory. Future work includes printing samples using identical parameters identified by partner institutions, providing material for corrosion and high-temperature mechanical testing, and continuing evaluations of heterogeneity in larger printed parts.

36 MATERIALS SCIENCE↗

BEYONDPLANCK XIII. Intensity foreground sampling, degeneracies, and priors

We present the intensity foreground algorithms and model employed within the BEYONDPLANCK analysis framework. The BEYONDPLANCK analysis is aimed at integrating component separation and instrumental parameter sampling within a global framework, leading to complete end-to-end error propagation in the Planck Low Frequency Instrument (LFI) data analysis. Given the scope of the BEYONDPLANCK analysis, a limited set of data is included in the component separation process, leading to foreground parameter degeneracies. In order to properly constrain the Galactic foreground parameters, we improve upon the previous Commander component separation implementation by adding a suite of algorithmic techniques. These algorithms are designed to improve the stability and computational efficiency for weakly constrained posterior distributions. These are: (1) joint foreground spectral parameter and amplitude sampling, building on ideas from MIRAMARE; (2) component-based monopole determination; (3) joint spectral parameter and monopole sampling; and (4) application of informative spatial priors for component amplitude maps. We find that the only spectral parameter with a significant signal-to-noise ratio using the current BEYONDPLANCK data set is the peak frequency of the anomalous microwave emission component, for which we find $ν$ p = 25.3 ± 0.5 GHz; all others must be constrained through external priors. Future works will be aimed at integrating many more data sets into this analysis, both map and time-ordered based, thereby gradually eliminating the currently observed degeneracies in a controlled manner with respect to both instrumental systematic effects and astrophysical degeneracies. When this happens, the simple LFI-oriented data model employed in the current work will need to be generalized to account for both a richer astrophysical model and additional instrumental effects. This work will be organized within the Open Science-based COSMOGLOBE community effort.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of smart 3D-digital X-ray microtomographic scanners for non-destructive testing of materials and components of electronic devices with a multilayered structure

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. Chapter 4 covers general procedures of defect search, which is based on vector analysis principles. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗