Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Two recent high-precision determinations of {alpha}{sub s}

The two highest precision determinations of {alpha}{sub s}(M{sub Z}{sup 2}), that based on the analysis of short-distance-sensitive lattice observables, and that based on an analysis of hadronic {tau} decay data, have, until recently, yielded results differing by {approx}3{sigma}. I review recent updates which bring the two determinations into excellent agreement, and discuss prospects for additional future improvements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On how once subtracted dispersion relations lead to a precise determination of {pi}{pi} scattering and the f{sub 0}(600) parameters

We present and compare once and twice subtracted dispersion relations including crossing symmetry constraints in order to test the S- and P-wave {pi}{pi} amplitudes below 1100 MeV. We show that twice subtracted dispersion relations provide stringent constraints on the {pi}{pi} amplitudes below about 400 MeV than those with one subtraction. Above this energy GKPY eqs. become, however, a more demanding test of {pi}{pi} amplitudes, thus providing a new tool for the precise determination of {pi}{pi} scattering. We also show that due to strong constraints imposed by the GKPY eqs. they are useful for the determination of the f{sub (600)} pole position with high accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mainz high-precision proton form factor measurement

An extensive measurement of the elastic H(e, e')p reaction in the Q{sup 2}-region from 0.003 to 1 (GeV/c){sup 2} has been performed with the 3-spectrometer-setup of the A1 collaboration at the Mainz Microtron. The dataset consists of about 3000 overlapping cross section measurements with a high level of internal redundancy. The large number of precisely measured cross sections allow for a determination of the electric and magnetic form factors with strict control over statistical and systematic errors, in particular also of the charge and magnetization radii of the proton. Besides the classical Rosenbluth separation, the form factors are separated by direct, global fits of different sufficiently flexible models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision spectroscopy of Kaonic helium-3 and helium-4 3d{yields}2p X-rays

Recently, the shift of the kaonic helium-4 2p state was precisely determined by the E570 and SIDDHARTA experiments. Prior to the experiment by E570, the average of three earlier experimental results showed -43{+-}8 eV,while most of the theoretical calculations give {approx}0 eV. This five-sigma discrepancy between theory and experiment was known as the 'kaonic helium puzzle'. A recent theoretical model showed a possible resonance-like shift of maximum 10 eV for a certain value of a deep antikaon-nucleon interaction potential, which is different in helium 3 and helium 4.The E570 experiment determined the shift of the kaonic helium-4 2p state as +2{+-}2 (stat){+-}2 (sys) eV in 2007. The SIDDHARTA experiment determined the shift as 0{+-}6(stat){+-}2(sys) eV in 2009. The results of these experiments resolved the long-standing puzzle. A new experiment of the kaonic helium-3 X-ray measurement is being prepared by the J-PARC E17 collaborators, and the kaonic helium-3 X-ray data taken very recently by the SIDDHARTA experiment are on the way to be analyzed. The results of the E570, E17 and SIDDHARTA experiments examine the strong interaction for light nuclei with different isospin, and test furthermore recent theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Axion Bounds from Precision Cosmology

Depending on their mass, axions produced in the early universe can leave different imprints in cosmic structures. If axions have masses in the eV-range, they contribute a hot dark matter fraction, allowing one to constrain m{sub a} in analogy to neutrinos. In the more favored scenario where axions play the role of cold dark matter and if reheating after inflation does not restore the Peccei-Quinn symmetry, the axion field provides isocurvature fluctuations that are severely constrained by precision cosmology. There remains a small sliver in parameter space where isocurvature fluctuations could still show up in future probes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A numerical method for determining highly precise electron energy distribution functions from Langmuir probe characteristics

Electron energy distribution functions (EEDFs) were determined from probe characteristics using a numerical ac superimposed method with a distortion correction of high derivative terms by varying amplitude of a sinusoidal perturbation voltage superimposed onto the dc sweep voltage, depending on the related electron energy. Low amplitude perturbation applied around the plasma potential represented the low energy peak of the EEDF exactly, and high amplitude perturbation applied around the floating potential was effective to suppress noise or distortion of the probe characteristic, which is fatal to the tail electron distribution. When a small random noise was imposed over the stabilized prove characteristic, the numerical differentiation method was not suitable to determine the EEDF, while the numerical ac superimposed method was able to obtain a highly precise EEDF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision measurements of kaon radiative decays at NA48/2

We report the most recent results of the NA48/2 experiment in charged kaon radiative decays. Using data collected during 2003 and 2004, precise measurements of the properties of K{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup 0}{gamma}, K{sup {+-}}{yields}{pi}{sup {+-}}{gamma}{gamma}, and K{sup {+-}}{yields}{pi}{sup {+-}}e{sup +}e{sup -}{gamma} decay modes have been obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision measurements of kaon radiative decays

We report the recent results of the NA48/2 experiment on charged kaon radiative decays. Using data collected during 2003 and 2004, precise measurements of the K{sup {+-}{yields}{pi}{+-}{pi}0{gamma}} and K{sup {+-}{yields}{pi}{+-}{gamma}{gamma}} decays properties have been obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of {pi}{pi} Scattering Lengths in K{sub e4} Decays

The measurement of the S-wave {pi}{pi} scattering lengths is a fundamental test of the validity of Chiral Perturbation Theory. We report on the final NA48/2 result, based on the full statistics data set of more than one million reconstructed K{sub e4}{sup {+-}} decays. From these events we have determined the decay form factors and {pi}{pi} scattering lengths a{sub 0}{sup 0} and a{sub 0}{sup 2}. The result is the currently most precise measurement of the scattering lengths and is in excellent agreement with the predictions of Chiral Perturbation Theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Possibility of precise measurements of muonium HFS at J-PARC MUSE

Intense pulsed muon beam will be available at J-PARC MUSE up to 4x10{sup 8}/s within a few years. We propose the next generation of the precise measurements of muonium hyperfine structure and the ratio of muon to proton magnetic moments by using the muonium spin resonance method at high magnetic field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision spectroscopy of kaonic {sup 3}He X-rays at J-PARC

We will measure the X-rays from kaonic {sup 3}He 3d {yields} 2p transition with a precision below 2 eV. It can provide crucial information on the kaon-nucleus strong interaction. The experiment (J-PARC E17) will be performed as Day-1, which is one of the first experiments in the J-PARC hadron facility in the year 2011. An overview and the present status of the J-PARC E17 experiment are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision determination of the electric and magnetic form factors of the proton

New precise results of a measurement of the elastic electron-proton scattering cross section performed at the Mainz Microtron MAMI are presented. About 1400 cross sections were measured with negative four-momentum transfers squared up to Q{sup 2} = (GeV/c){sup 2} with statistical errors below 0.2%. The electric and magnetic form factors of the proton were extracted by fits of a large variety of form factor models directly to the cross sections. The form factors show some features at the scale of the pion cloud. The charge and magnetic radii are determined to be r{sub E}{sup 2} rpost={sup >>1/2} 0.879(5){sub stat.}(4){sub syst.}(2){sub model}(4){sub group}fm and r{sub M}{sup 2} {sup 1/2} = 0.777(13){sub stat.}(9){sub syst.}(5)model({sub 2})groupfm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Spectroscopy of Kaonic Helium-3 X-rays at J-PARC

We will measure the x-rays from kaonic {sup 3}He and {sup 4}He 3d{yields}2p transition by using silicon drift detectors. Our precision goal is set to 1 eV to provide crucial information on the kaon-nucleus strong interaction in the low energy limit. The experiment is to be performed as one of the first experiment in the J-PARC hadron facility (J-PARC E17). An overview and the present status of the experiment are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise measurement of the {sup 19}Ne half-life

We describe a high-precision measurement of the half-life of the T = 1/2 nucleus {sup 19}Ne, performed at TRIUMF, Canada's National Laboratory for Nuclear and Particle Physics, Vancouver, Canada. Some implications of this measurement related to tests of the Standard Model are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-precision {beta} decay half-life measurements of proton-rich nuclei for testing the CVC hypothesis

The experimental study of super-allowed nuclear {beta} decays serves as a sensitive probe of the conservation of the weak vector current (CVC) and allows tight limits to be set on the presence of scalar or right-handed currents. Once CVC is verified, it is possible to determine the V{sub ud} element of the CKM quark-mixing matrix. Similarly, the study of nuclear mirror {beta} decays allows to arrive at the same final quantity V{sub ud}. Whereas dedicated studies of 0{sup +}{yields}0{sup +} decays are performed for several decades now, the potential of mirror transitions was only rediscovered recently. Therefore, it can be expected that important progress is possible with high-precision studies of different mirror {beta} decays. In the present piece of work the half-life measurements performed by the CENBG group of the proton-rich nuclei {sup 42}Ti, {sup 38-39}Ca, {sup 30-31}S and {sup 29}P are summarised.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrade of the Resonance Ionization Mass Spectrometer for Precise Identification of Failed Fuel in a Fast Reactor

Isotopic analysis of krypton (Kr) and xenon (Xe) by resonance ionization mass spectrometry (RIMS) is an effective tool for identification of failed fuel in fast reactors to achieve their safety operation and high plant availability. Reliability of the failed fuel detection and location (FFDL) system depends on the precise determination of {sup 78}Kr/{sup 80}Kr, {sup 82}Kr/{sup 80}Kr and {sup 126}Xe/{sup 129}Xe isotopic ratios, which is mainly hampered by statistical errors for detection of the corresponding isotopes except {sup 82}Kr generated in large amounts during operation of fast reactors. In this paper, we report on improvements of the laser optical system of our spectrometer to increase the resonance ionization efficiency of Kr and Xe atoms, focusing on (i) utilization of the uniform YAG laser beam to improve the wavelength conversion efficiency of sum frequency generation and (ii) reflection of the ultraviolet light by a concave mirror to increase the photon density. The results indicate that our upgraded resonance ionization mass spectrometer has enough performance for isotopic analysis of Kr and Xe required in the Monju FFDL system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The on-line charge breeding program at TRIUMF's Ion Trap For Atomic and Nuclear Science for precision mass measurements

TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) constitutes the only high precision mass measurement setup coupled to a rare isotope facility capable of increasing the charge state of short-lived nuclides prior to the actual mass determination in a Penning trap. Recent developments around TITAN's charge breeder, the electron beam ion trap, form the basis for several successful experiments on radioactive isotopes with half-lives as low as 65 ms and in charge states as high as 22+.

43 PARTICLE ACCELERATORS↗

Cation stoichiometry optimization of SrTiO{sub 3} (110) thin films with atomic precision in homogeneous molecular beam epitaxy

We study the evolution of surface reconstructions on SrTiO{sub 3} (110) determined by cation concentration ratio and find it detectable by high energy electron diffraction (RHEED) even at high temperature up to 800 deg. C. The evaporation rate of Sr and Ti sources can be calibrated precisely by monitoring RHEED patterns in situ and in real time during the extended homogeneous oxide molecule beam epitaxy growth of SrTiO{sub 3} (110) film. High quality film is obtained with deviation of cation stoichiometry less than 0.5%.

36 MATERIALS SCIENCE↗