Compton Imaging: Principles and Practice
Book chapter on Compton Imaging: Principles and Practice
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Book chapter on Compton Imaging: Principles and Practice
This position paper discusses issues of usability of the large parallel file systems in the Livermore Computing Center. The primary uses of these file systems are for storage and access of data that is created during the course of a simulation running on an LC system. The Livermore Computing Center has multiple, globally mounted parallel file systems in each of its computing environments. The single biggest issue of file system usability that we have encountered through the years is to maintain continuous file system responsiveness. Given the back end storage hardware that our file systems are provisioned with, it is easily possible for a particularly I/O intensive application or one with particularly inefficiently coded I/O operations to bring the file system to an apparent halt. The practice that we will be addressing is one of having an ability to indentify, diagnose, analyze and optimize the I/O quickly and effectively.
It has been my experience that behavioral science practitioners, including myself, often 'back into' action research. That is, we start out doing a process improvement or intervention and discover something along the way - generalizable knowledge - that seems worthwhile to share with our community of practice. What if, instead of looking at these projects from the point of view of practitioners, we looked at them as research from the outset? Would that change the outcome or generate additional knowledge? This paper compares and contrasts process improvement and action research methods, and illustrates how use of a research 'lens' can enhance behavioral science interventions and the knowledge that may result from them.
This paper discusses how the American Petroleum Institute oil and gas standards were interfaced with International Electrotechnical Commission and other wind turbine and offshore industry standards to provide guidance for reliable engineering design practices for offshore wind energy systems.
The inherent variability in corn stover productivity due to variations in soils and crop management practices might contribute to a variation in corn stover-based bioethanol sustainability. This study was carried out to examine how changes in soil types and crop management options would affect corn stover yield (CSY) and the sustainability of the stover-based ethanol production in the Delta region of Mississippi. Based on potential acreage and geographical representation, three locations were selected. Using CERES-Maize model, stover yields were simulated for several scenarios of soils and crop management options. Based on 'net energy value (NEV)' computed from CSYs, a sustainability indicator for stover-based bioethanol production was established. The effects of soils and crop management options on CSY and NEV were determined using ANOVA tests and regression analyses. Both CSY and NEV were significantly different across sandy loam, silt loam, and silty clay loam soils and also across high-, mid-, and low-yielding cultivars. With an increase in irrigation level, both CSY and NEV increased initially and decreased after reaching a peak. A third-degree polynomial relationship was found between planting date and CSY and NEV each. By moving from the lowest to the highest production scenario, values of CSY and NEV could be increased by 86 to 553%, depending on location and weather condition. The effects of variations in soils and crop management options on NEV were the same as on CSY. The NEV was positive for all scenarios, indicating that corn stover-based ethanol production system in the Delta region is sustainable.
The presentation discussed findings of a recent NREL technical report on best practices for designing and implementing incentives for small and mid-sized residential and commercial distributed solar energy projects. Topics covered included: factors to consider in setting and modifying incentive levels over time, differentiating incentives to encourage various market segments, and administrative issues such as providing equitable access to incentives and customer protection. In addition, the presentation explored how incentive programs can be designed to respond to changing market conditions while attempting to provide a longer-term and stable environment for the solar industry. The findings of the report were based on interviews with program administrators, regulators, and industry representatives as well as data from numerous incentive programs nationally, particularly the largest and longest-running programs.
For net zero energy (NZE) buildings to become the norm in commercial construction, it will be necessary to design and construct these buildings cost effectively. While industry leaders have developed workflows (for procurement, design, and construction) to achieve cost-effective NZE buildings for certain cases, the expertise embodied in those workflows has limited penetration within the commercial building sector. Documenting cost control best practices of industry leaders in NZE and packaging those strategies for adoption by the commercial building sector will help make the business case for NZE. Furthermore, it will promote market uptake of the innovative technologies and design approaches needed to achieve NZE. This paper summarizes successful cost control strategies for NZE procurement, design, and construction that key industry users (such as building owners, architects, and designers) can incorporate into their everyday workflows. It will also evaluate the current state of NZE economics and propose a path forward for greater market penetration of NZE buildings. By demonstrating how to combine NZE technologies and design approaches into an overall efficiency package that can be implemented at minimal (zero, in certain cases) incremental capital cost, the domain of NZE design and construction can be expanded from a niche market to the commercial construction mainstream.
Roofing systems—particularly in the western part of the United States—are often installed directly to a wood deck, with the building’s insulation below the deck. This construction assembly has a long track record of performance and generally has been used without consequence with traditional built-up roof systems. In recent years, there has been an increase in “conversation” in the roofing industry about anecdotal instances of wood deck deterioration being discovered a relatively short period of time after a roofing system has been installed. Investigations into these occurrences have generally concluded that interior moisture is condensing on the wood deck and causing rot. Hygrothermal modeling of specific roofing systems has confirmed these conclusions. These failures are not being caused by roofing system leaks but by the movement of moisture through the insulation and into the deck and roofing assembly. Unfortunately, these types of failures are becoming more common as the roofing industry (driven by a variety of influences, including regulatory mandate) moves from traditional built-up roofing systems in these markets to reflective membranes—either white or highly reflective “cool”-colored single-ply membranes or white reflective cap sheets. The application of reflective coating can also result in this type of failure....Based on the need for some practical guidelines, a research project was initiated with Oak Ridge National Laboratory’s (ORNL) Building Envelope Group to model the potential for wood deck deterioration under a variety of conditions and to provide guidelines for the amount of insulation that should be installed over a wood deck to reduce this risk.
"Resilience” describes how systems operate at an acceptable level of normalcy despite disturbances or threats. In this paper we first consider the cognitive, cyber-physical interdependencies inherent in critical infrastructure systems and how resilience differs from reliability to mitigate these risks. Terminology and metrics basis are provided to integrate the cognitive, cyber-physical aspects that should be considered when defining solutions for resilience. A practical approach is taken to roll this metrics basis up to system integrity and business case metrics that establish “proper operation” and “impact.” A notional chemical processing plant is the use case for demonstrating how the system integrity metrics can be applied to establish performance, and
Organizations use structured, plan-driven approaches to provide continuity, direction, and control to large, multi-year programs. Projects within these programs vary greatly in size, complexity, level of maturity, technical risk, and clarity of the development objectives. Organizations that perform exploratory research, evolutionary development, and other R&D activities can obtain the benefits of Agile practices without losing the benefits of their program’s overarching plan-driven structure. This paper describes application of Agile development methods on a large plan-driven sensor integration program. While the client employed plan-driven, requirements flow-down methodologies, tight project schedules and complex interfaces called for frequent end-to-end demonstrations to provide feedback during system development. The development process maintained the many benefits of plan-driven project execution with the rapid prototyping, integration, demonstration, and client feedback possible through Agile development methods. This paper also describes some of the tools and implementing mechanisms used to transition between and take advantage of each methodology, and presents lessons learned from the project management, system engineering, and developer’s perspectives.
This fact sheet presents highlights from the Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications, which provides detailed information about solar resource data and the resulting data products needed for planning each stage of large concentrating solar power systems, from initial site selection to system operations.
FEMP Water Efficiency Best Management Practice #14 Case Study: Overview of the air handler condensate recovery program at the Environmental Protection Agency's Science and Ecosystem Support Division.
Case study overview of the Huntington Veterans Affairs Medical Center water efficiency program as part of FEMP's water efficiency best management practice series.
This paper focuses on three of the most practical high-performance wall systems to achieve whole-wall performance of R-30 or above.
The U.S. Air Force’s Air Mobility Command (AMC) is changing the way it does business. It is saving energy and money through an aircraft fleet fuel-efficiency program inspired by private industry best practices and ideas resulting from the empowered fuel savings culture.
In this Top Innovation profile, field and lab studies by BSC, PHI, and NorthernSTAR characterize the thermal, air, and vapor resistance properties of rigid foam insulation and describe best practices for their use on walls, roofs, and foundations.
We present that analytics software is increasingly used to improve and maintain operational efficiency in commercial buildings. Energy managers, owners, and operators are using a diversity of commercial offerings often referred to as Energy Information Systems, Fault Detection and Diagnostic (FDD) systems, or more broadly Energy Management and Information Systems, to cost-effectively enable savings on the order of ten to twenty percent. Most of these systems use data from meters and sensors, with rule-based and/or data-driven models to characterize system and building behavior. In contrast, physics-based modeling uses first-principles and engineering models (e.g., efficiency curves) to characterize system and building behavior. Historically, these physics-based approaches have been used in the design phase of the building life cycle or in retrofit analyses. Researchers have begun exploring the benefits of integrating physics-based models with operational data analytics tools, bridging the gap between design and operations. In this paper, we detail the development and operator use of a software tool that uses hybrid data-driven and physics-based approaches to cooling plant FDD and optimization. Specifically, we describe the system architecture, models, and FDD and optimization algorithms; advantages and disadvantages with respect to purely data-driven approaches; and practical implications for scaling and replicating these techniques. Finally, we conclude with an evaluation of the future potential for such tools and future research opportunities.
Modeling supercritical CO2 (sCO2) power cycles requires specification of system constraints and component performance metrics such as pressure losses and temperature limitations.? Differing assumptions made by the model designers may lead to significantly different results which are due to the assumptions and not to the underlying thermodynamics which characterize the cycle performance. As leaders in setting standards for techno-economic analyses, NETL and EPRI have collaborated to propose a set of practical modeling assumptions that can serve as a common baseline for both indirect and direct sCO2 power plant studies, allowing for more meaningful cycle comparisons. These include specifications for turbine inlet temperature (high temperature and pressure limitations), compressor inlet temperature and pressure (cooling limitations), heat exchanger effectiveness/temperature differentials and pressure drop, and full- and part-load turbine and compressor efficiencies.