Global Sensitivity Analysis of Large Distribution System with PVs using Deep Gaussian Process

Global sensitivity analysis (GSA) of the voltage to uncertain power injection variations plays an important role for appropriate Volt-VAR optimization. This paper proposes a data-driven GSA method for large-scale distribution systems with a large number of uncertain sources. Specifically, the deep Gaussian process is used to identify the mapping relationship between uncertain power injections and voltages. This allows us to resort to the analysis of variance framework to calculate the Sobol indices for GSA. Unlike the existing polynomial chaos expansion and Gaussian process-based approaches, our proposed method has much better scalability. Test results on the EPRI 1747-node K1 circuit with a different number and different probability distributions of uncertain sources demonstrate that the proposed method can achieve accurate GSA under various conditions.

14 SOLAR ENERGY↗

A Study of Imbalance Levels Attributed to Photovoltaic Penetration in Distribution Systems

Abstract— The number of renewable sources, namely photovoltaics (PV), continues to grow within distribution systems. How placements impact a system’s performance remains a concern within both the research and the utility communities. Beyond system node voltages and real power losses, this work looks to industry standard imbalance metrics and the changes experienced on these values with varied levels of PV. Specifically, four imbalance metrics are presented and studied for an actual 906-bus distribution system. Multiple loading conditions and photovoltaic placement schemes are explored to compare the changes seen on these metrics across a variety of scenarios experienced by the network.

14 SOLAR ENERGY↗

Implementation of a virtual link between power system testbeds at Marshall Spaceflight Center and Lewis Research Center

The Marshall Space Flight Center (MSFC) owns and operates a space station module power management and distribution (SSM-PMAD) testbed. This system, managed by expert systems, is used to analyze and develop power system automation techniques for Space Station Freedom. The Lewis Research Center (LeRC), Cleveland, Ohio, has developed and implemented a space station electrical power system (EPS) testbed. This system and its power management controller are representative of the overall Space Station Freedom power system. A virtual link is being implemented between the testbeds at MSFC and LeRC. This link would enable configuration of SSM-PMAD as a load center for the EPS testbed at LeRC. This connection will add to the versatility of both systems, and provide an environment of enhanced realism for operation of both testbeds.

Doreswamy, Rajiv↗

Space Solar Power Technical Interchange Meeting 2: SSP TIM 2

The 2nd Space Solar Power Technical Interchange Meeting (SSP TIM 2) was conducted September 21st through 24th with the first part consisting of a Plenary session. The summary results of this Plenary session are contained in part one of this report. The attendees were then organized into Working Breakout Sessions and Integrated Product Team (IPT) Sessions for the purpose of conducting in-depth discussions in specific topic areas and developing a consensus as to appropriate study plans and actions to be taken. The Second part covers the Plenary Summary Session, which contains the summary results of the Working Breakout Sessions and IPT Sessions. The appendix contains the list of attendees. The ob'jective was to provide an update for the study teams and develop plans for subsequent study activities. This SSP TIM 2 was initiated and the results reported electronically over the Internet. The International Space Station (ISS) could provide the following opportunities for conducting research and technology (R&T) which are applicable to SSP: (1) Automation and Robotics, (2) Advanced Power Generation, (3) Advanced Power Management & Distribution (PMAD), (4) Communications Systems and Networks, (5) Energy Storage, (6) In Space Propulsion (ISP), (7) Structural Dynamics and Control, and Assembly and (8) Wireless Power Transmission.

Sanders, Jim↗

Connecting Minds: AI Use Cases to Bridge Power Systems and Large Language Models for Practical Applications

Recent advances in artificial intelligence (AI) and development of large language models (LLMs) present the opportunity to develop a new generation of power systems applications. In contrast with early power system AI applications based on structured numerical data, LLMs offer unique capabilities to perform logical reasoning using text documents, unstructured data, and application programming interface (API) calls to computational software. This paper seeks to bridge the knowledge gap between power systems engineers and LLM developers through a crosscutting explanation of use cases, characteristics, requirements, practical considerations from the perspectives of both LLM capabilities and industry needs. Specific focus is given to applications that can be realistically deployed by electric utilities. After introducing the architecture of LLMs and unique challenges of the power systems domain, this paper proposes twenty representative LLM applications grouped into categories of 1) power system operations, 2) asset management, 3) system planning and analytics, and 4) energy management and protection systems. Five use cases are presented within each category with descriptions of the motivation, objectives, approaches, example inputs / outputs, and benefits of each use case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DLMP of Competitive Markets in Active Distribution Networks: Models, Solutions, Applications, and Visions

Traditionally, the electric distribution system operates with uniform energy prices across all system nodes. However, as the adoption of distributed energy resources (DERs) propels a shift from passive to active distribution network (ADN) operation, a distribution-level electricity market has been proposed to manage new complexities efficiently. In addition, distribution locational marginal price (DLMP) has been established in the literature as the primary pricing mechanism. The DLMP inherits the LMP concept in the transmission-level wholesale market but incorporates characteristics of the distribution system, such as high $R/X$ ratios and power losses, system imbalance, and voltage regulation needs. The DLMP provides a solution that can be essential for competitive market operation in future distribution systems. This article first provides an overview of the current distribution-level market architectures and their early implementations. Next, the general clearing model, model relaxations, and DLMP formulation are comprehensively reviewed. The state-of-the-art solution methods for distribution market clearing are summarized and categorized into centralized, distributed, and decentralized methods. Then, DLMP applications for the operation and planning of DERs and distribution system operators (DSOs) are discussed in detail. Finally, visions of future research directions and possible barriers and challenges are presented.

42 ENGINEERING↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗

Extracting Resilience Metrics From Distribution Utility Data Using Outage and Restore Process Statistics

Resilience curves track the accumulation and restoration of outages during an event on an electric distribution grid. We show that a resilience curve generated from utility data can always be decomposed into an outage process and a restore process and that these processes generally overlap in time. We use many events in real utility data to characterize the statistics of these processes, and derive formulas based on these statistics for resilience metrics such as restore duration, customer hours not served, and outage and restore rates. The formulas express the mean value of these metrics as a function of the number of outages in the event. We also give a formula for the variability of restore duration, which allows us to predict a maximum restore duration with 95% confidence. Overall, we give a simple and general way to decompose resilience curves into outage and restore processes and then show how to use these processes to extract resilience metrics from standard distribution system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Summary of the NASA Lewis component technology program for Stirling power converters

An update is presented on the NASA Lewis Stirling component technology program. The component technology program has been organized as part of the NASA Lewis effort to develop Stirling converter technology for space power applications. The Stirling space power project is part of the High Capacity Power element of the NASA Civil Space Technology Initiative (CSTI). Lewis is also providing technical management of a DOE funded project to develop Stirling converter systems for distributed dish solar terrestrial power applications. The primary contractors for the space power and solar terrestrial projects develop component technologies directly related to their project goals. This Lewis component technology program, while coordinated with these main projects, is aimed at longer term issues, advanced technologies, and independent assessments. Topics to be discussed include bearings, linear alternators, controls and load interaction, materials/life assessment, and heat exchangers.

Thieme, Lanny G.↗

Overview of the NASA Lewis component technology program for Stirling power converters

This paper presents an update on the NASA Lewis Stirling component technology program. The component technology program has been organized as part of the NASA Lewis effort to develop Stirling converter technology for space power applications. The Stirling space power program is part of the High Capacity Power element of the NASA Civil Space Technology Initiative. Lewis is also providing technical management of a DOE-funded project to develop Stirling converter systems for distributed dish solar terrestrial power applications. The Lewis component technology program is coordinated with the primary contract efforts of these projects but is aimed at longer term issues, advanced technologies, and independent assessments. Topics to be discussed include bearings, linear alternators, controls and load interaction, materials/life assessment, and heat exchangers.

Thieme, Lanny G.↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.