Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Sink or Swim: A Tutorial on the Control of Floating Wind Turbines: Preprint

Within the rapidly growing wind energy sector, floating offshore wind turbines are expected to be the fastest growing portion. This is largely driven by the immense offshore wind resources that are mostly over deep water, where fixed-bottom concepts become cost prohibitive. However, compared to fixed-bottom wind turbines, floating wind turbines are more dynamic and exhibit potential instabilities, which requires advanced control technologies to ensure a safe and efficient operation. Beyond their existing objectives of maximizing power production while minimizing structural loads, floating wind turbine controllers must also avoid large platform oscillations and accommodate wave disturbances. This paper provides an overview of the challenges and opportunities in the control of floating offshore wind energy systems.

control↗

AI-Based Faster-Than-Real-Time Stability Assessment of Large Power Systems with Applications on WECC System

Achieving clean energy goals will require significant advances in regard to addressing the computational needs for next-generation renewable-dominated power grids. One critical obstacle that lies in the way of transitioning today’s power grid to a renewable-dominated power grid is the lack of a faster-than-real-time stability assessment technology for operating a fast-changing power grid. This paper proposes an artificial intelligence (AI) -based method that predicts the system’s stability margin information (e.g., the frequency nadir in the frequency stability assessment and the critical clearing time (CCT) value in the transient stability assessment) directly from the system operating conditions without performing the conventional time-consuming time-domain simulations over detailed dynamic models. Since the AI method shifts the majority of the computational burden to offline training, the online evaluation is extremely fast. This paper has tested the AI-based stability assessment method using multiple dispatch cases that are converted and tuned from actual dispatch cases of the Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. The results show that the AI-based method could accurately predict the stability margin of such a large power system in less than 0.2 milliseconds using the offline-trained AI agent. Therefore, the proposed method has great potential to achieve faster-than-real-time stability assessment for practical large power systems while preserving sufficient accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling system for reducing fatigue and dynamic amplification of loads in objects

A coupling system can include an energy transfer device and a load mitigation system. The energy transfer device can include a shaft, gear, chain or piston-cylinder arrangement to transfer the energy from a power supply to an object to be moved. The load mitigation system can be used to limit or prevent the transfer of forces from the object to the drive unit as a result of external loads being applied to the object. The load mitigation system can be pre-loaded such that external loads on the object having an excessive impulsive or resonant cyclic force greater than the pre-load force on the load mitigation system are reduced and only partially transferred to the energy transfer device and power supply. The load mitigation system can dampen both resonant loads and impulsive impact loads occurring at the object thereby preventing damage and extending life.

Blackmon, James B.↗

Coupling system for reducing fatigue and dynamic amplification of loads in objects

A coupling system can include an energy transfer device and a load mitigation system. The energy transfer device can include a shaft, gear, chain or piston-cylinder arrangement to transfer the energy from a power supply to an object to be moved. The load mitigation system can be used to limit or prevent the transfer of forces from the object to the drive unit as a result of external loads being applied to the object. The load mitigation system can be pre-loaded such that external loads on the object having an excessive impulsive or resonant cyclic force greater than the pre-load force on the load mitigation system are reduced and only partially transferred to the energy transfer device and power supply. The load mitigation system can dampen both resonant loads and impulsive impact loads occurring at the object thereby preventing damage and extending life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Physics and technology considerations for the deuterium–tritium fuel cycle and conditions for tritium fuel self sufficiency

The tritium aspects of the DT fuel cycle embody some of the most challenging feasibility and attractiveness issues in the development of fusion systems. The review and analyses in this paper provide important information to understand and quantify these challenges and to define the phase space of plasma physics and fusion technology parameters and features that must guide a serious R&D in the world fusion program. We focus in particular on components, issues and R&D necessary to satisfy three 'principal requirements': (1) achieving tritium self-sufficiency within the fusion system, (2) providing a tritium inventory for the initial start-up of a fusion facility, and (3) managing the safety and biological hazards of tritium. A primary conclusion is that the physics and technology state-of-the-art will not enable DEMO and future power plants to satisfy these principal requirements. We quantify goals and define specific areas and ideas for physics and technology R&D to meet these requirements. A powerful fuel cycle dynamics model was developed to calculate time-dependent tritium inventories and flow rates in all parts and components of the fuel cycle for different ranges of parameters and physics and technology conditions. Dynamics modeling analyses show that the key parameters affecting tritium inventories, tritium start-up inventory, and tritium self-sufficiency are the tritium burn fraction in the plasma (f b ), fueling efficiency (η f ), processing time of plasma exhaust in the inner fuel cycle (t p ), reactor availability factor (AF), reserve time (tr) which determines the reserve tritium inventory needed in the storage system in order to keep the plant operational for time t r in case of any malfunction of any part of the tritium processing system, and the doubling time (t d ). Results show that η f f b > 2% and processing time of 1–4 h are required to achieve tritium self-sufficiency with reasonable confidence. For η f f b = 2% and processing time of 4 h, the tritium start-up inventory required for a 3 GW fusion reactor is ~11 kg, while it is <5 kg if η f f b = 5% and the processing time is 1 h. To achieve these stringent requirements, a serious R&D program in physics and technology is necessary. The EU-DEMO direct internal recycling concept that carries fuel directly from the plasma exhaust gas to the fueling systems without going through the isotope separation system reduces the overall processing time and tritium inventories and has positive effects on the required tritium breeding ratio (TBR R ). A significant finding is the strong dependence of tritium self-sufficiency on the reactor availability factor. Simulations show that tritium self-sufficiency is: impossible if AF < 10% for any η f f b , possible if AF > 30% and 1% ≤ η f f b ≤ 2%, and achievable with reasonable confidence if AF > 50% and η f f b > 2%. These results are of particular concern in light of the low availability factor predicted for the near-term plasma-based experimental facilities (e.g. FNSF, VNS, CTF), and can have repercussions on tritium economy in DEMO reactors as well, unless significant advancements in RAMI are made. There is a linear dependency between the tritium start-up inventory and the fusion power. The required tritium start-up inventory for a fusion facility of 100 MW fusion power is as small as 1 kg. Since fusion power plants will have large powers for better economics, it is important to maintain a 'reserve' tritium inventory in the tritium storage system to continue to fuel the plasma and avoid plant shutdown in case of malfunctions of some parts of the tritium processing lines. But our results show that a reserve time as short as 24 h leads to unacceptable reserve and start-up inventory requirements. Therefore, high reliability and fast maintainability of all components in the fuel cycle are necessary in order to avoid the need for storing reserve tritium inventory sufficient for continued fusion facility operation for more than a few hours. The physics aspects of plasma fueling, tritium burn fraction, and particle and power exhaust are highly interrelated and complex, and predictions for DEMO and power reactors are highly uncertain because of lack of experiments with burning plasma. Fueling by pellet injection on the high field side of tokamak has evolved to be the preferred method to fuel a burning plasma. Extrapolation from the DIII-D penetration scaling shows fueling efficiency expected in DEMO to be <25%, but such extrapolations are highly uncertain. The fueling efficiency of gas in a reactor relevant regime is expected to be extremely poor and not very useful for getting tritium into the core plasma efficiently. Gas fueling will nonetheless be useful for feedback control of the divertor operating parameters. Extensive modeling has been carried out to predict burn fraction, fueling requirements, and fueling efficiency for ITER, DEMO, and beyond. The fueling rate required to operate Q = 10 ITER plasmas in order to provide the required core fueling, helium exhaust and radiative divertor plasma conditions for acceptable divertor power loads was calculated. If this fueling is performed with a 50–50 DT mix, the tritium burn fraction in ITER would be ~0.36%, which is too low to satisfy the self-sufficiency conditions derived from the dynamics modeling for fusion reactors. Extrapolation to DEMO using this approach would also yield similarly low burn fraction. Extensive analysis presented shows that specific features of edge neutral dynamics in ITER and fusion reactors, which are different from present experiments, open possibilities for optimization of tritium fueling and thus to improve the burn fraction. Using only tritium in pellet fueling of the plasma core, and only deuterium for edge density, divertor power load and ELM control results in significant increase of the burn fraction to 1.8–3.6%. These estimates are performed with physics models whose results cannot be fully validated for ITER and DEMO plasma conditions since these cannot be achieved in present tokamak experiments. Thus, several uncertainties remain regarding particle transport and scenario requirements in ITER and DEMO. The safety standard requirements for protection of the public and release guidelines for tritium have been reviewed. General safety approaches including minimizing tritium inventories, reducing tritium permeation through materials, and decontaminating material for waste disposal have been suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charaterization of Emerging Computing Architectures for Dynamic Simulation of Future Power Grids with Large-Scale Power Electronics

The increasing penetration of power electronics in power grids significantly raises the computing requirements in a real-time (and/or fast) simulation of the power grid. The real-time simulation is an enabler for evaluating controllers, protection systems, new equipment, and twinning. In this paper, emerging computing architectures such as tensor processing units (TPU), neural/neuromorphic processing units (NPU), and quantum processing units (QPU) are introduced and characterized for the real-time (and/or fast) simulation of power electronics-dominated power grids. The metrics and the process to characterize emerging computing architectures to perform real-time (and/or fast) simulations of future power grids with power electronics are discussed. Three of the emerging computing units are characterized based on these metrics and the process developed. This characterization will enable identification and comparison of emerging computing architectures that can perform real-time (and/or fast) simulation of future power grids.

Choi, Jongchan↗

Application of Chebyshev’s Inequality in Online Anomaly Detection Driven by Streaming PMU Data

The day-to-day operation of modern power systems is highly reliant on prompt and adequate situational-awareness. This can be achieved via various system monitoring functions such as anomaly detection, in which static thresholds are commonly utilized to distinguish the normal and the abnormal system states. However, a predetermined static threshold usually lacks the flexibility to adapt to unobserved scenarios. In this paper, we propose two self-adaptive synchrophasor data driven anomaly detection approaches based on Chebyshev’s Inequality. The proposed approaches have been evaluated with Kundur’s 2area system and Mini-WECC system. Experimental results verify that the proposed approaches can dynamically adapt to unprecedented scenarios, and detect anomalous events with lower false alarm rate compared to static threshold based detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Impact of the Exciter and Governor Parameters on Forced Oscillations

In recent years, the frequency of forced oscillation events due to control system malfunctions or improper parameter settings has increased. Tuning the parameters of exciters and governor models is crucial for maintaining power system stability. Traditional simulation studies typically involve small transient disturbances or step changes to find optimal parameter sets, but existing optimization algorithms often fall short in fine-tuning for forced oscillations. Identifying the sensitive parameters within these control models is essential for ensuring stability during large, sustained disturbances. This study focuses on identifying these critical exciter and governor model parameters by analyzing their influence on sustained forced oscillations. Using Kundur’s two-area system, we analyze common exciter models such as SCRX, ESST1A, and AC7B, along with governor models like GAST, HYGOV, and GGOV1, utilizing PSS®E software version 34. Sustained forced oscillations are injected at generator-1 of area-1, with individual parameter changes dynamically simulated. By considering a local oscillation frequency of 1.4 Hz and an inter-area oscillation mode of 0.25 Hz, we analyze the impact of each parameter change on the magnitude and frequency of forced oscillations as well as on active and reactive power outputs. This novel approach highlights the most influential parameters of each tested model—such as exciter, governor, and turbine gains, as well as time constant parameters—on the impact of forced oscillations. Based on our findings, the sensitive parameters of each tested model are ranked. These would provide valuable insights for industry operators to fine-tune control settings during oscillation events, ultimately enhancing system stability.

42 ENGINEERING↗

A Comprehensive Method to Mitigate Forced Oscillations in Large Interconnected Power Grids

Multiple severe forced oscillation events have recently been observed across the North American interconnections and around the world. These forced oscillations have caused power swings, limited power transfer capability, damaged equipment, and persisted indefinitely until the driving source was located and removed. This paper proposes a comprehensive method to mitigate forced oscillations. Once a forced oscillation is detected, a new source location algorithm can be used to locate the source based on the oscillation mode angle without requiring system topology information. If the source cannot be quickly located and removed, a control strategy can be activated to modulate the active power of utility-scale inverterbased battery energy storage systems (BESSs) to reduce the energy of forced oscillations to a safe level and allow sufficient time for locating the exact source. The proposed source location algorithm is validated using measurements collected during the January 11, 2019 forced oscillation event in North America and other actual grid events, while the proposed control strategy is verified using the Eastern Interconnection dynamic model under the replicated January 11, 2019 forced oscillation event. The simulation results demonstrated that the proposed source location algorithm can accurately identify the forced oscillation source, and the proposed control strategy can significantly reduce forced oscillation energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation-Based Recovery Action Analysis Using the EMRALD Dynamic Risk Assessment Tool

A recovery action is defined as the action that prevents deviant conditions from producing unwanted effects. It generally indicates a kind of countermeasure performed in response to a failure of human action. The recovery actions especially play an important role in complex systems like nuclear power plants (NPPs), which consist of highly sophisticated controllers to ensure that desired performance and safety must be achieved and maintained. This is because a combination of human error and its recovery failure may be able to cause a catastrophic effect on a system. Analyzing recovery actions has been a critical part of HRA, which is a technique to evaluate human errors and provide human error probabilities (HEPs) for application in probabilistic safety assessment (PSA). If recovery actions are not adequately analyzed and applied to PSA models, the PSA results may be under-estimated or be not able to reasonably account for the failure of human actions in the context of PSA. For this reason, some regulatory documents such as ASME/ANS RA-Sb-2013 by the American Society for Mechanical Engineers and the American Nuclear Society and NUREG-1792 by U.S. Nuclear Regulatory Commission have emphasized the importance of recovery analysis within the HRA. A couple of existing HRA methods, such as the Technique for Human Error-Rate Prediction (THERP), the Cause-Based Decision Tree (CBDT), and the Korean Standard HRA (K-HRA), have respectively suggested their own approaches to the HRA recovery analysis. However, there are a couple of limitations to treating recovery actions using only the current HRA methods available. The biggest limitation is that the existing recovery analysis does not explicitly consider a variety of recovery action types and recovery sequences as they occur in actual NPPs. To handle the limitations of existing recovery analysis, this study proposes a simulation-based recovery analysis method using the Event Modeling Risk Assessment Using Linked Diagram (EMRALD) software. The EMRALD software is a dynamic simulation tool for PSA. It supports realistic and dynamic modeling of human actions as they would be performed at NPPs. It is also favorable to simultaneously model the specific moment at which an action is performed, the time it takes to perform the action, and the failure probability of that action. In this paper, a detailed methodology for modeling recovery actions in the simulation platform is proposed with a couple of examples. Then, outputs from the simulation are discussed as reviewing if this novel approach can complement the challenges of existing recovery analyses.

99 GENERAL AND MISCELLANEOUS↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancing Pressure Gain Combustion for Terrestrial Turbine Systems

The principal objectives of this project were to demonstrate the operability of a natural gas - air RDE at gas turbine engine cycle conditions. To achieve these goals, our specific tasks were to 1) characterize the dynamic injection and mixing performance of candidate injectors, 2) assess the engine operability via interrogation of spatio-temporal dynamics of combustor inlet and exit flows, 3) measure the engine emissions, and 4) complete an overall assessment of the pressure gain potential of the device. In order to advance RDE technology to the greatest extent possible, the reactants and experimental conditions were chosen to replicate combustor and injector conditions in a terrestrial power generation system. This path was taken because the scaling of combustion devices is, in general, an immature area given the challenges of interrelated mixing and chemical kinetics processes both of which scale with operating conditions.

03 NATURAL GAS↗

Physiochemical Machine Learning Models Predict Operational Lifetimes of CH3NH3PbI3 Perovskite Solar Cells

Halide perovskites are promising photovoltaic (PV) materials with the potential to lower the cost of electricity and greatly expand the penetration of PV if they can demonstrate long-term stability under illumination in the presence of moisture and oxygen. The solar cell service lifetime as quantified by the T80 (the time required for the power conversion efficiency to drop to 80% of its starting value) is a useful metric to assess stability. The T80 for utility, commercial, or residential PV systems needs to be several decades in order to yield low-cost electricity, and thus it is not practical to directly measure the T80. It would be useful if T80 could be predicted from the initial dynamics of a solar cell’s performance, but until now no models have been developed to forecast T80. In this work, we report the development of machine learning models to predict T80 of ITO/NiOx/CH3NH3PbI3/C60/BCP/Ag solar cells operating at maximum power point under 1-sun equivalent photon flux in air at varying temperatures and relative humidities. Efficiency losses are driven by short-circuit current and fill factor, indicating that chemical decomposition of the perovskite is a major contributor to degradation. Spatial patterns evident from in situ dark field optical microscopy suggest that the electric field gradient at device edges plays a significant role in perovskite decomposition, along with photochemical reactions with O2 and H2O. Models are trained using a menu of features from three distinct categories: (i) features based on measurements of the initial rates of change of device parameters, (ii) features based on the ambient conditions during operation (temperature, & partial pressure of H2O), and (iii) features based on underlying physics and chemistry. We show that a theory-based physiochemical feature derived from a model of the chemical reaction kinetics of the rate of degradation of the CH3NH3PbI3 is particularly valuable for prediction. This physiochemical feature was selected as the first or second most dominant feature in the best performing models. With a dataset consisting of 45 accelerated degradation experiments with T80 that range over a factor of 30, the model predicts T80 with an accuracy of about 40% (|predicted T80 - observed T80| / observed T80) on samples not used in training. This hybrid ML approach should be effective when applied to other compositions, device architectures, and advanced packaging schemes.

14 SOLAR ENERGY↗

Physiochemical Machine Learning Models Predict Operational Lifetimes of CH3NH3PbI3 Perovskite Solar Cells

Halide perovskites are promising photovoltaic (PV) materials with the potential to lower the cost of electricity and greatly expand the penetration of PV if they can demonstrate long-term stability under illumination in the presence of moisture and oxygen. The solar cell service lifetime as quantified by the T80 (the time required for the power conversion efficiency to drop to 80% of its starting value) is a useful metric to assess stability. The T80 for utility, commercial, or residential PV systems needs to be several decades in order to yield low-cost electricity, and thus it is not practical to directly measure the T80. It would be useful if T80 could be predicted from the initial dynamics of a solar cell’s performance, but until now no models have been developed to forecast T80. In this work, we report the development of machine learning models to predict T80 of ITO/NiOx/CH3NH3PbI3/C60/BCP/Ag solar cells operating at maximum power point under 1-sun equivalent photon flux in air at varying temperatures and relative humidities. Efficiency losses are driven by short-circuit current and fill factor, indicating that chemical decomposition of the perovskite is a major contributor to degradation. Spatial patterns evident from in situ dark field optical microscopy suggest that the electric field gradient at device edges plays a significant role in perovskite decomposition, along with photochemical reactions with O2 and H2O. Models are trained using a menu of features from three distinct categories: (i) features based on measurements of the initial rates of change of device parameters, (ii) features based on the ambient conditions during operation (temperature, & partial pressure of H2O), and (iii) features based on underlying physics and chemistry. We show that a theory-based physiochemical feature derived from a model of the chemical reaction kinetics of the rate of degradation of the CH3NH3PbI3 is particularly valuable for prediction. This physiochemical feature was selected as the first or second most dominant feature in the best performing models. With a dataset consisting of 45 accelerated degradation experiments with T80 that range over a factor of 30, the model predicts T80 with an accuracy of about 40% (|predicted T80 - observed T80| / observed T80) on samples not used in training. This hybrid ML approach should be effective when applied to other compositions, device architectures, and advanced packaging schemes.

14 SOLAR ENERGY↗

Momentum-resolved analysis of condensate dynamic and Higgs oscillations in quenched superconductors with time-resolved ARPES

Higgs oscillations in nonequilibrium superconductors provide a unique tool to obtain information about the underlying order parameter. Several properties like the absolute value, existence of multiple gaps, and the symmetry of the order parameter can be encoded in the Higgs oscillation spectrum. Studying Higgs oscillations with time-resolved angle-resolved photoemission spectroscopy (ARPES) has the advantage over optical measurements that a momentum-resolved analysis of the condensate dynamic is possible. In this paper, we investigate the time-resolved spectral function measured in ARPES for different quench protocols. We find that analyzing amplitude oscillations of the ARPES intensity in the whole Brillouin zone allows to understand how the condensate dynamic contributes to the emerging of collective Higgs oscillations. Furthermore, by evaluating the phase of these oscillations, the symmetry deformation dynamic of the condensate can be revealed, which gives insight about the ground state symmetry of the system. With such an analysis, time-resolved ARPES experiments might be used in the future as a powerful tool in the field of Higgs spectroscopy.

36 MATERIALS SCIENCE↗