Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Electron density measurements in a pulse-repetitive microwave discharge in air

We have developed a technique for absolute measurements of electron density in pulse-repetitive microwave discharges in air. The technique is based on the time-resolved absolute intensity of a nitrogen spectral band belonging to the Second Positive System, the kinetic model and the detailed particle balance of the N{sub 2}C{sup 3}{Pi}{sub u} ({nu} = 0) state. This new approach bridges the gap between two existing electron density measurement methods (Langmuir probe and Stark broadening). The electron density is obtained from the time-dependent rate equation for the population of N{sub 2}C{sup 3}{Pi}{sub u} ({nu} = 0) using recorded waveforms of the absolute C{sup 3}{Pi}{sub u}{yields}B{sup 3}{Pi}{sub g} (0-0) band intensity, the forward and reflected microwave power density. Measured electron density waveforms using numerical and approximated analytical methods are presented for the case of pulse repetitive planar surface microwave discharge at the aperture of a horn antenna covered with alumina ceramic plate. The discharge was generated in air at 11.8 Torr with a X-band microwave generator using 3.5 {mu}s microwave pulses at peak power of 210 kW. In this case, we were able to time resolve the electron density within a single 3.5 {mu}s pulse. We obtained (9.0 {+-} 0.6) x 10{sup 13} cm{sup -3} for the peak and (5.0 {+-} 0.6) x 10{sup 13} cm{sup -3} for the pulse-average electron density. The technique presents a convenient, non-intrusive diagnostic method for local, time-defined measurements of electron density in short duration discharges near atmospheric pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tools and techniques for estimating high intensity RF effects

Tools and techniques for estimating and measuring coupling and component disturbance for avionics and electronic controls are described. A finite-difference-time-domain (FD-TD) modeling code, TSAR, used to predict coupling is described. This code can quickly generate a mesh model to represent the test object. Some recent applications as well as the advantages and limitations of using such a code are described. Facilities and techniques for making low-power coupling measurements and for making direct injection test measurements of device disturbance are also described. Some scaling laws for coupling and device effects are presented. A method for extrapolating these low-power test results to high-power full-system effects are presented.

Zacharias, Richard L.↗

Accelerating Development of Advanced Inverters.

Increasing the penetration of distributed renewable sources, including photovoltaic (PV) generators, poses technical challenges for grid management. The grid has been optimized over decades to rely on large centralized power plants with well-established feedback controls. Conventional generators provide relatively constant dispatchable power and help to regulate both voltage and frequency. In contrast, photovoltaic (PV) power is variable, is only as predictable as the weather, and provides no control action. Thus, as conventional generation is displaced by PV power, utility operation stake holders are concerned about managing fluctuations in grid voltage and frequency. Furthermore, since the operation of these distributed resources are bound by certain rules that require they stop delivering power when measured voltage or frequency deviate from the nominal operating point, there are also concerns that a single grid event may cause a large fraction of generation to turn off, triggering a black out or break-up of an electric power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ganged-PV System Evaluation

The following report contains data and data summaries collected for the SkySun LLC elevated Ganged PV arrays. These arrays were fabricated as a series of PV panels in various orientations, suspended by cables, at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL). Starting in February of 2021, Sandia personnel have collected power and accelerometer data for these arrays to assess design and operational efficacy of varying ganged- PV configurations. The purpose of this power data collection was to see how the various array orientations compare in power collection capability depending on the time of day, year, and the specific daily solar direct normal irradiance (DNI). The power data was collected as a measurement of the power output from the various series strings. The project team measured direct current (DC) voltage and current from the respective arrays. The accelerometer data was collected with the purpose of demonstrating potential destructive mode shapes that could take place with each of the arrays when exposed to high winds. This allowed the team to evaluate whether impacts with respect to specific array orientations using suspended cables is a safe design. All data collection was performed during calendar year 2021.

14 SOLAR ENERGY↗

Principal shapes and squeezed limits in the effective field theory of large scale structure

We apply an orthogonalization procedure on the effective field theory of large scale structure (EFT of LSS) shapes, relevant for the angle-averaged bispectrum and non-Gaussian covariance of the matter power spectrum at one loop. Assuming natural-sized EFT parameters, this identifies a linear combination of EFT shapes—referred to as the principal shape—that gives the dominant contribution for the whole kinematic plane, with subdominant combinations suppressed by a few orders of magnitude. For the covariance, our orthogonal transformation is in excellent agreement with a principal component analysis applied to available data. Additionally we find that, for both observables, the coefficients of the principal shapes are well approximated by the EFT coefficients appearing in the squeezed limit, and are thus measurable from power spectrum response functions. Employing data from N-body simulations for the growth-only response, we measure the single EFT coefficient describing the angle-averaged bispectrum with Ο (10%) precision. These methods of shape orthogonalization and measurement of coefficients from response functions are valuable tools for developing the EFT of LSS framework, and can be applied to more general observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The annoyance of multiple noisy events

A total of 24 subjects (17 M, 7 F) was tested in an experimental study of annoyance rating of multiple noisy events (30 sets of noise bursts). The scaling technique known as functional measurement was used to determine whether annoyance integrates additively over events and if so, to measure the power law exponent which relates the levels of the events to the additive scale values. To this end, groups of three noises were presented at three levels in a factorial arrangement to check the additivity hypothesis and to estimate the scaling function. Also, a series of sets of noises of constant level but varying in set size were considered. The functional measurement of annoyance ratings of sets of three simulated flyovers showed that the integration of annoyance can be represented as an additive process in terms of scale values that are power functions of the sound power with a power-law exponent near 0.7.

Ahumada, A., Jr.↗

The 3D Lyman- α forest power spectrum from eBOSS DR16

We measure the three-dimensional power spectrum (P3D) of the transmitted flux in the Lyman-α (Ly α) forest using the complete extended Baryon Oscillation Spectroscopic Survey data release 16 (eBOSS DR16). This sample consists of ~205 000 quasar spectra in the redshift range 2 ≤ z ≤ 4 at an effective redshift z = 2.334. We propose a pair-count spectral estimator in configuration space, weighting each pair by exp( i k ∙ r), for wave vector k and pixel pair separation r, effectively measuring the anisotropic power spectrum without the need for fast Fourier transforms. This accounts for the window matrix in a tractable way, avoiding artefacts found in Fourier-transform based power spectrum estimators due to the sparse sampling transverse to the line of sight of Ly α skewers. We extensively test our pipeline on two sets of mocks: (i) idealized Gaussian random fields with a sparse sampling of Ly α skewers, and (ii) log-normal LyaCoLoRe mocks including realistic noise levels, the eBOSS survey geometry and contaminants. On eBOSS DR16 data, the Kaiser formula with a non-linear correction term obtained from hydrodynamic simulations yields a good fit to the power spectrum data in the range $(0.02 ≤ k ≤ 0.35)$ h Mpc -1 at the 1–2σ level with a covariance matrix derived from LyaCoLoRe mocks. We demonstrate a promising new approach for full-shape cosmological analyses of Ly α forest data from cosmological surveys such as eBOSS, the currently observing Dark Energy Spectroscopic Instrument and future surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST.

79 ASTRONOMY AND ASTROPHYSICS↗

An Improved Measurement of the Secondary Cosmic Microwave Background Anisotropies from the SPT-SZ + SPTpol Surveys

We report new measurements of millimeter-wave power spectra in the angular multipole range 2000 ≤ ℓ ≤ 11,000 (angular scales ). By adding 95 and 150 GHz data from the low-noise 500 deg 2 SPTpol survey to the SPT-SZ three-frequency 2540 deg 2 survey, we substantially reduce the uncertainties in these bands. These power spectra include contributions from the primary cosmic microwave background, cosmic infrared background, radio galaxies, and thermal and kinematic Sunyaev–Zel'dovich (SZ) effects. The data favor a thermal SZ (tSZ) power at 143 GHz of and a kinematic SZ (kSZ) power of . This is the first measurement of kSZ power at ≥3 σ . However, different assumptions about the CIB or SZ models can reduce the significance down to 2.4 σ in the worst case. We study the implications of the measured kSZ power for the epoch of reionization under the Calabrese et al. model for the kSZ power spectrum and find the duration of reionization to be ( at 95% confidence), when combined with our previously published tSZ bispectrum measurement. The upper limit tightens to if the assumed homogeneous kSZ power is increased by 25% (~0.5 μ K 2 ) and relaxes to if the homogeneous kSZ power is decreased by the same amount.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization and Improvement of RNA-Seq Precision in Quantitative Transcript Expression Profiling

Measurement precision determines the power of any analysis to reliably identify significant signals, such as in screens for differential expression, independent of whether the experimental design incorporates replicates or not. With the compilation of large scale RNA-Seq data sets with technical replicate samples, however, we can now, for the first time, perform a systematic analysis of the precision of expression level estimates from massively parallel sequencing technology. This then allows considerations for its improvement by computational or experimental means. Results: We report on a comprehensive study of target coverage and measurement precision, including their dependence on transcript expression levels, read depth and other parameters. In particular, an impressive target coverage of 84% of the estimated true transcript population could be achieved with 331 million 50 bp reads, with diminishing returns from longer read lengths and even less gains from increased sequencing depths. Most of the measurement power (75%) is spent on only 7% of the known transcriptome, however, making less strongly expressed transcripts harder to measure. Consequently, less than 30% of all transcripts could be quantified reliably with a relative error < 20%. Based on established tools, we then introduce a new approach for mapping and analyzing sequencing reads that yields substantially improved performance in gene expression profiling, increasing the number of transcripts that can reliably be quantified to over 40%. Extrapolations to higher sequencing depths highlight the need for efficient complementary steps. In discussion we outline possible experimental and computational strategies for further improvements in quantification precision.

59 BASIC BIOLOGICAL SCIENCES↗

Cosmological constraints from the tomography of DES-Y3 galaxies with CMB lensing from ACT DR4

We present a measurement of the cross-correlation between the MagLim galaxies selected from the Dark Energy Survey (DES) first three years of observations (Y3) and cosmic microwave background (CMB) lensing from the Atacama Cosmology Telescope (ACT) Data Release 4 (DR4), reconstructed over ∼ 436 deg 2 of the sky. Our galaxy sample, which covers ∼ 4143 deg 2 , is divided into six redshift bins spanning the redshift range of 0.20 < z <1.05. We adopt a blinding procedure until passing all consistency and systematics tests. After imposing scale cuts for the cross-power spectrum measurement, we reject the null hypothesis of no correlation at 9.1σ. We constrain cosmological parameters from a joint analysis of galaxy and CMB lensing-galaxy power spectra considering a flat ΛCDM model, marginalized over 23 astrophysical and systematic nuisance parameters. We find the clustering amplitude S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.75 +0.04 -0.05 . In addition, we constrain the linear growth of cosmic structure as a function of redshift. Our results are consistent with recent DES Y3 analyses and suggest a preference for a lower S 8 compared to results from measurements of CMB anisotropies by the Planck satellite, although at a mild level (< 2σ) of statistical significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimized Swinging Door Algorithm for Wind Power Ramp Event Detection: Preprint

Significant wind power ramp events (WPREs) are those that influence the integration of wind power, and they are a concern to the continued reliable operation of the power grid. As wind power penetration has increased in recent years, so has the importance of wind power ramps. In this paper, an optimized swinging door algorithm (SDA) is developed to improve ramp detection performance. Wind power time series data are segmented by the original SDA, and then all significant ramps are detected and merged through a dynamic programming algorithm. An application of the optimized SDA is provided to ascertain the optimal parameter of the original SDA. Measured wind power data from the Electric Reliability Council of Texas (ERCOT) are used to evaluate the proposed optimized SDA.

17 WIND ENERGY↗

DES-Y3 galaxies & ACT DR4 CMB lensing tomography

We present a measurement of the cross-correlation between the \maglim galaxies selected from the Dark Energy Survey (DES) first three years of observations (Y3) and cosmic microwave background (CMB) lensing from the Atacama Cosmology Telescope (ACT) Data Release 4 (DR4), reconstructed over $\sim 436$ $\sqdeg$ of the sky. Our galaxy sample, which covers $\sim 4143$ $\sqdeg$, is divided into six redshift bins spanning the redshift range of $0.20<z<1.05$. We adopt a blinding procedure until passing all consistency and systematics tests. After imposing scale cuts for the cross-power spectrum measurement, we reject the null hypothesis of no correlation at 9.1$\sigma$. We constrain cosmological parameters from a joint analysis of galaxy and CMB lensing-galaxy power spectra considering a flat \LCDM model, marginalized over 23 astrophysical and systematic nuisance parameters. We find the clustering amplitude $S_8\equiv \sigma_8 (\Omega_m/0.3)^{0.5} = 0.75^{+0.04}_{-0.05}$. In addition, we co nstrain the linear growth of cosmic structure as a function of redshift. Our results are consistent with recent DES Y3 analyses and suggest a preference for a lower $S_8$ compared to results from measurements of CMB anisotropies by the \textit{Planck} satellite, although at a mild level ($< 2 \sigma$) of statistical significance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combined Gamma Ray/neutron Spectroscopy for Mapping Lunar Resources

Some elements in the Moon can be resources, such as hydrogen and oxygen. Other elements, like Ti or the minerals in which they occur, such as ilmenite, could be used in processing lunar materials. Certain elements can also be used as tracers for other elements or lunar processes, such as hydrogen for mature regoliths with other solar-wind-implanted elements like helium, carbon, and nitrogen. A complete knowledge of the elemental composition of a lunar region is desirable both in identifying lunar resources and in lunar geochemical studies, which also helps in identifying and using lunar resources. The use of gamma ray and neutron spectroscopy together to determine abundances of many elements in the top few tens of centimeters of the lunar surface is discussed. To date, very few discussions of elemental mapping of planetary surfaces considered measurements of both gamma rays and the full range of neutron energies. The theories for gamma ray and neutron spectroscopy of the Moon and calculations of leakage fluxes are presented here with emphasis on why combined gamma ray/neutron spectroscopy is much more powerful than measuring either radiation alone.

Reedy, R. C.↗

Aerodynamic Measurements of a Variable-Speed Power-Turbine Blade Section in a Transonic Turbine Cascade

The purpose of this thesis is to document the impact of incidence angle and Reynolds number variations on the three-dimensional flow field and midspan loss and turning of a two-dimensional section of a variable-speed power-turbine (VSPT) rotor blade. Aerodynamic measurements were obtained in a transonic linear cascade at NASA Glenn Research Center in Cleveland, Ohio. Steady-state data were obtained for 10 incidence angles ranging from +15.8deg to -51.0deg. At each angle, data were acquired at five flow conditions with the exit Reynolds number (based on axial chord) varying over an order-of-magnitude from 2.12×105 to 2.12×106. Data were obtained at the design exit Mach number of 0.72 and at a reduced exit Mach number of 0.35 as required to achieve the lowest Reynolds number. Midspan tota lpressure and exit flow angle data were acquired using a five-hole pitch/yaw probe surveyed on a plane located 7.0 percent axial-chord downstream of the blade trailing edge plane. The survey spanned three blade passages. Additionally, three-dimensional half-span flow fields were examined with additional probe survey data acquired at 26 span locations for two key incidence angles of +5.8deg and -36.7deg. Survey data near the endwall were acquired with a three-hole boundary-layer probe. The data were integrated to determine average exit total-pressure and flow angle as functions of incidence and flow conditions. The data set also includes blade static pressures measured on four spanwise planes and endwall static pressures.

Flegel, Ashlie B.↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

Mass measurements of neutron-rich indium isotopes toward the N = 82 shell closure

Precise mass measurements of the neutron-rich 125–130 In isotopes have been performed with the TITAN Penning trap mass spectrometer. TITAN's electron beam ion trap was used to charge breed the ions to charge state q = 13+ thus providing the necessary resolving power to measure not only the ground states but also isomeric states at each mass number. Here, the properties of the ground states are investigated through a series of mass differentials, highlighting trends in the indium isotopic chain as compared to its proton-magic neighbor, tin (Z = 50). In addition, the energies of the indium isomers are presented. The (8 - ) level in 128 In is found to be 78 keV lower than previously thought and the (21/2 - ) isomer in 127 In is shown to be lower than the literature value by more than 150 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Neutrino Oscillation Measurements using Simultaneous High-Power, Low-Energy Project-X Beams

The first phase of the long-baseline neutrino experiment, LBNE10, will use a broadband, high-energy neutrino beam with a 10-kt liquid argon TPC at 1300 km to study neutrino oscillation. In this paper, we describe potential upgrades to LBNE10 that use Project X to produce high-intensity, low-energy neutrino beams. Simultaneous, high-power operation of 8- and 60-GeV beams with a 200-kt water Cerenkov detector would provide sensitivity to nu_mu to nu_e oscillations at the second oscillation maximum. We find that with ten years of data, it would be possible to measure sin2(2theta_13) with precision comparable to that expected from reactor antineutrino disappearance and to measure the value of the CP phase, delta_CP, with an uncertainty of (5-10) degrees. This document is submitted for inclusion in Snowmass 2013.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An analysis of the uncertainty and bias in DCE-MRI measurements using the spoiled gradient-recalled echo pulse sequence

Purpose: The pharmacokinetic parameters derived from dynamic contrast-enhanced (DCE) MRI have been used in more than 100 phase I trials and investigator led studies. A comparison of the absolute values of these quantities requires an estimation of their respective probability distribution function (PDF). The statistical variation of the DCE-MRI measurement is analyzed by considering the fundamental sources of error in the MR signal intensity acquired with the spoiled gradient-echo (SPGR) pulse sequence. Methods: The variance in the SPGR signal intensity arises from quadrature detection and excitation flip angle inconsistency. The noise power was measured in 11 phantoms of contrast agent concentration in the range [0–1] mM (in steps of 0.1 mM) and in onein vivo acquisition of a tumor-bearing mouse. The distribution of the flip angle was determined in a uniform 10 mM CuSO{sub 4} phantom using the spin echo double angle method. The PDF of a wide range of T1 values measured with the varying flip angle (VFA) technique was estimated through numerical simulations of the SPGR equation. The resultant uncertainty in contrast agent concentration was incorporated in the most common model of tracer exchange kinetics and the PDF of the derived pharmacokinetic parameters was studied numerically. Results: The VFA method is an unbiased technique for measuringT1 only in the absence of bias in excitation flip angle. The time-dependent concentration of the contrast agent measured in vivo is within the theoretically predicted uncertainty. The uncertainty in measuring K{sup trans} with SPGR pulse sequences is of the same order, but always higher than, the uncertainty in measuring the pre-injection longitudinal relaxation time (T1{sub 0}). The lowest achievable bias/uncertainty in estimating this parameter is approximately 20%–70% higher than the bias/uncertainty in the measurement of the pre-injection T1 map. The fractional volume parameters derived from the extended Tofts model were found to be extremely sensitive to the variance in signal intensity. The SNR of the pre-injection T1 map indicates the limiting precision with which K{sup trans} can be calculated. Conclusions: Current small-animal imaging systems and pulse sequences robust to motion artifacts have the capacity for reproducible quantitative acquisitions with DCE-MRI. In these circumstances, it is feasible to achieve a level of precision limited only by physiologic variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗