Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Compact Quantum Cascade Laser Transmitter

): In this paper we present design considerations, thermal and optical modeling results, and device performance for a ruggedized, compact laser transmitter that utilizes a room temperature quantum cascade (QC) laser source. The QC laser transmitter is intended for portable mid-infrared (3-12 µm) spectroscopy applications, where the atmospheric transmission window is relatively free of water vapor interference and where the molecular rotational vibration absorption features can be used to detect and uniquely identify chemical compounds of interest. Initial QC laser-based sensor development efforts were constrained by the complications of cryogenic operation. However, improvements in both QC laser designs and fabrication processes have provided room-temperature devices that now enable significant miniaturization and integration potential for national security, environmental monitoring, atmospheric science, and industrial safety applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Combining Phase Identification and Statistic Modeling for Automated Parallel Benchmark Generation

Parallel application benchmarks are indispensable for evaluating/optimizing HPC software and hardware. However, it is very challenging and costly to obtain high-fidelity benchmarks reflecting the scale and complexity of state-of-the-art parallel applications. Hand-extracted synthetic benchmarks are time-and labor-intensive to create. Real applications themselves, while offering most accurate performance evaluation, are expensive to compile, port, reconfigure, and often plainly inaccessible due to security or ownership concerns. This work contributes APPRIME, a novel tool for trace-based automatic parallel benchmark generation. Taking as input standard communication-I/O traces of an application's execution, it couples accurate automatic phase identification with statistical regeneration of event parameters to create compact, portable, and to some degree reconfigurable parallel application benchmarks. Experiments with four NAS Parallel Benchmarks (NPB) and three real scientific simulation codes confirm the fidelity of APPRIME benchmarks. They retain the original applications' performance characteristics, in particular the relative performance across platforms.

Jin, Ye↗

Characterizing Photometric Flicker. Handheld Meters

Temporal light modulation (TLM) is the variation of light output as a function of time and its presence can have adverse effects on health and visual performance (e.g., increased occurrence of migraines, reduced visual-task performance). TLM has been the subject of recent articles primarily associated with flicker in LED lighting. Lighting system characteristics that can affect flicker vary by technology; examples include filament thickness for incandescent sources, phosphor persistence for fluorescent and coated metal halide sources, and circuit designs for electronically ballasted or driven sources. The characterization of flicker, especially in the field, is important to ensure adequate living and working conditions. Today, various types of flicker meters are available, including high-speed and precise benchtop models for laboratory environments and portable handheld meters that can range from simple smartphone applications in an existing smart device to scientific grade meters that have capabilities beyond flicker measurements. In this report, the performance of various handheld meters capable of measuring flicker in the field is compared to a reference benchtop meter chosen based on its performance in the initial round of meter comparisons performed by Pacific Northwest National Laboratory.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SHAD: the Scalable High-performance Algorithms and Data-structures Library

The unprecedented amount of data that needs to be processed in emerging data analytics applications poses novel challenges to industry and academia. Scalability and high performance become more than a desirable feature because, due to the scale and the nature of the problems, they draw the line between what is achievable and what is unfeasible. In this paper, we propose SHAD, the Scalable High-performance Algorithms and Data-structures library. SHAD adopts a modular design that confines low level details and promotes reuse. SHAD's core is built on an Abstract Runtime Interface which enhances portability and identifies the minimal set of features of the underlying system required by the framework. The core library includes common data-structures such as: Array, Vector, Map and Set. These are designed to accommodate significant amount of data which can be accessed in massively parallel environments, and used as building blocks for SHAD extensions, i.e. higher level software libraries. We have validated and evaluated our design with a performance and scalability study of the core components of the library. We have validated the design flexibility by proposing a Graph Library as an example of SHAD extension, which implements two different graph data-structures; we evaluate their performance with a set of graph applications. Experimental results show that the approach is promising in terms of both performance and scalability. On a distributed system with 320 cores, SHAD Arrays are able to sustain a throughput of 65 billion operations per second, while SHAD Maps sustain 1 billion of operations per second. Algorithms implemented using the Graph Library exhibit performance and scalability comparable to a custom solution, but with smaller development effort.

Castellana, Vito G.↗

miniWeather

The code “miniWeather” solves the 2-D Euler equations with a Finite-Volume method on a regular Cartesian grid with Runge-Kutta time stepping, 4th-order hypervisocisty, and 4th-order spatial accuracy. The code is primarily a parallel programming training mini application in Fortran, C, and C++ with MPI, OpenMP, OpenMP offload, OpenACC, and C++ portability approaches. It can also serve as a mini application for acceptance testing for new machines and compilers for both functionality and performance.

Norman, MatthewR↗

Modeling and Simulation of MC-Small Design

In order to design a lightweight, highly portable neutron multiplicity counter for use in higher risk regions by mobile field teams, a redesign of the MC-15 is being performed, with the goal of producing a detector below 30 lbs for ease of transport. To achieve this, multiple MCNP® simulations were run, evaluating the number and positioning of the He-3 tubes in the detector as well as the amount of high-density polyethylene (HDPE) surrounding the tubes. Based on these simulations, the proposed redesign of the MC-15 (aka MC-Small) possesses 11 tubes and is 13 in wide, 3.21 in thick and 13 in tall. Including the changes to the positioning of the tubes and the removal of HDPE from less sensitive regions of the detectors (i.e. bases of tubes, back of detector), this resulted in an efficiency of 0.56% when measuring a bare Cf-252 source 19.69 in away, only 28% less efficient (relatively) than the MC-15 while weighing 18 lbs, 12 lbs less than the weight of the MC-15.

42 ENGINEERING↗

Rapid, portable, multiplexed detection of bacterial pathogens directly from clinical sample matrices

Enteric and diarrheal diseases are a major cause of childhood illness and death in countries with developing economies. Each year, more than half of a million children under the age of five die from these diseases. We have developed a portable, microfluidic platform capable of simultaneous, multiplexed detection of several of the bacterial pathogens that cause these diseases. Furthermore, this platform can perform fast, sensitive immunoassays directly from relevant, complex clinical matrices such as stool without extensive sample cleanup or preparation. Using only 1 µL of sample per assay, we demonstrate simultaneous multiplexed detection of four bacterial pathogens implicated in diarrheal and enteric diseases in less than 20 min.

47 OTHER INSTRUMENTATION↗

Development of a Portable In Situ Phosphorous Sensor

While phosphorus is a critical nutrient for all forms of life, runoff leads to phosphorus accumulation in surface water where it can cause a variety of health, environmental, and economic problems. The Department of Energy is interested in conducting long-term field experiments to monitor the impact of phosphorus in terrestrial and aquatic environments, and to better understand a cost vs. benefit analysis of reducing phosphorus pollution. Performing such long-term experiments requires affordable sensors capable of monitoring low-level phosphorus concentrations under challenging environmental conditions. However, such sensors are currently not available. The goal of this proposed project is to develop and demonstrate a low-cost portable phosphorus sensor suitable for in situ measurements. We will determine the technical requirements for a Raman-based sensor system, design and build a signal amplifier, integrate it with a Raman-based sensor, and demonstrate a proof-of-concept level sensor system. The expected accomplishments for Phase I include the identification of the technical requirements of a combined Raman laser/spectrometer and cavity enhancement system, building a proof-of-concept level sensor system capable of detecting orthophosphate compounds at the desired level of 0.25 mg P/L and organic P compounds, and verification of the sensor performance under laboratory and field conditions. In addition, we will identify initial hardening requirements that will need to be implemented during Phase II. While we plan to develop an integrated sensor system for monitoring phosphorus, the cavity-based enhancement system can also be used in combination with other (non-phosphorus) Raman sensors that we plan to develop or that are already commercially available. A recent market report highlights the increasing demand for such environmental monitoring applications, with the market for chemical detection anticipated to grow at a compound annual growth rate of 6.5% (2020-2025). Wide-spread monitoring of phosphorus could reduce the damage from eutrophication in freshwater, which is estimated to be $2.2 billion annually, thereby increasing biodiversity, reducing costs required for drinking water treatment, and decreasing economic losses related to recreation and angling and lake property values.

54 ENVIRONMENTAL SCIENCES↗

Demonstration Report: Handheld UXO Discriminator, SERDP No. MR-1667

In 2003, the Defense Science Board observed: 'The problem is that instruments that can detect the buried UXOs also detect numerous scrap metal objects and other artifacts, which leads to an enormous amount of expensive digging. Typically 100 holes may be dug before a real UXO is unearthed! The Task Force assessment is that much of this wasteful digging can be eliminated by the use of more advanced technology instruments that exploit modern digital processing and advanced multi-mode sensors to achieve an improved level of discrimination of scrap from UXOs.' In keeping with these remarks and with prior funding (UX-1225, MM-0437, and MM-0838), the LBNL group has successfully designed and built the cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (cf. Gasperikova et al., 2007, 2008, and 2009). Because hand-held systems have the advantage of being lightweight, compact, portable, and deployable under most site conditions, they are particularly useful in areas of dense vegetation or challenging terrain. In heavily wooded areas or areas with steep or uneven terrain, hand-held sensors may be the only suitable device for UXO detection and discrimination because it can be carried through spaces that the operator could walk through or at least approach. Furthermore, it is desirable to find and characterize a metallic object without the need to accurately locate the sensors at multiple positions around the target. The ideal system would thus locate and characterize the target from a single position of the sensor and indicate to the operator where to flag the target for subsequent study. Based on these considerations, we designed and built a sensor package in a shape of a 14-in (0.35 m) cube. This hand-held prototype incorporates the key features of the cart-mounted system - (a) three orthogonal transmitters and ten pairs of receivers, and (b) difference or gradient measurements that significantly reduce the ambient and motion noise, and greatly enhance the sensitivity to the gradients of the target. The system characterizes the target from a single position. Results from a local test site were in a good agreement with theoretical performance calculations of such a device. This survey was designed to demonstrate performance of the system under realistic survey conditions at the Aberdeen Proving Ground (APG) in Aberdeen, MD. The survey was preformed in an area with known items ('Calibration Grid'), and in a seeded blind test area (the 'Blind Test Grid'). The ground truth for the surveys conducted on the Blind Test Grid was withheld from the testers. Only the graded test scores based on target detection and target classification were provided. For more information, see http://aec.army.mil/usaec/technology/uxo01c03.html.

54 ENVIRONMENTAL SCIENCES↗

Evolution of LIBS technology to mobile instrumentation for expediting firearm-related investigations at the laboratory and the crime scene

Gunshot residue (GSR) is one of the few forensic disciplines that lack accurate screening techniques. This study proposes using a mobile LIBS instrument to detect inorganic GSR and compares performance to a previously validated laboratory instrument. The mobile LIBS is designed with advanced configurations specifically for on-site GSR analysis, including a CMOS detector and a sampling chamber that holds up to six typical GSR collection devices with separate gas flow ports to prevent cross-contamination. A significant novelty of the portable instrument is its image magnification, which allows quick searching and visualization of GSR particle morphology. The single-particle imaging and elemental composition capability is one of a kind and offers superior confirmatory features for GSR. The mobile LIBS performance was evaluated for residues collected from the hands of shooters (100 samples) and non-shooters (200 background samples), analyzed sequentially by the mobile instrument and then the laboratory instrument. Accuracies better than 98.8% were obtained by both instruments, demonstrating their suitability for trace IGSR detection from skin specimens. Implementation of this methodology is anticipated to drastically speed up response times (i.e., from several hours per sample by standard SEM-EDS practice to a few minutes by LIBS). The screening methods can be easily incorporated into workflows to improve decision-making processes at the crime scene and laboratory settings, reduce backlogs, and improve case management.

47 OTHER INSTRUMENTATION↗

Lightweight runtime checking of C programs with RTC

The C Programming Language is known for being an efficient language that can be compiled on almost any architecture and operating system. However the absence of dynamic safety checks and a relatively weak type system allows programmer oversights that are hard to spot. In this paper, we present RTC, a runtime monitoring tool that instruments unsafe code and monitors the program execution. RTC is built on top of the ROSE compiler infrastructure. RTC finds memory bugs and arithmetic overflows and underflows, and run-time type violations. Most of the instrumentations are directly added to the source file and only require a minimal runtime system. As a result, the instrumented code remains portable. In tests against known error detection benchmarks, RTC found 98% of all memory related bugs and had zero false positives. Finally, in performance tests conducted with well known algorithms, such as binary search and MD5, we determined that our tool has an average run-time overhead rate of 9.7× and memory overhead rate of 3.5×.

97 MATHEMATICS AND COMPUTING↗

Science and Technology Review (March 2014)

Over the past few years, Lawrence Livermore has experienced a surge of innovation in radiochemistry—the science of generating, identifying, isolating, and characterizing the radioactive isotopes of chemical elements. For example, Livermore researchers have developed a technique for producing double-sided target foils and built a target surface mapping tool, which increased the productivity of stockpile stewardship experiments. Radiochemists are also using the Laboratory’s particle accelerator to measure nuclear reaction products for reactor safety and nuclear forensics research. Another Livermore team is making synthetic nuclear debris samples with ingredients that more closely match debris from a real explosion for use in isotope identification exercises. Researchers are also refining the chemicals and protocols required to perform wet-chemistry experiments on transactinides, shortlived heavy elements such as flerovium and livermorium. A collaboration with two universities is developing a portable, automated system that can quickly capture, prepare, and chemically test radioisotopes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Fissionable Material

Experiments have been performed at Idaho National Laboratory to study methodology and instrumentation for performing neutron active interrogation die-away analyses for the purpose of detecting shielded fissionable material. Here we report initial work using a portable DT electronic neutron generator with a He-3 fast neutron detector to detect shielded fissionable material including >2 kg quantities of enriched uranium and plutonium. Measurements have been taken of bare material as well as of material hidden within a large plywood cube. Results from this work have demonstrated the efficacy of the die-away neutron measurement technique for quickly detecting the presence of special nuclear material hidden within plywood shields by analyzing the time dependent neutron signals in-between neutron generator pulses. Using a DT electronic neutron generator operating at 300 Hz with a yield of approximately 0.36 x 10**8 neutrons per second, 2.2 kg of enriched uranium hidden within a 0.60 m x 0.60 m x 0.70 m volume of plywood was positively detected with a measurement signal 2-sigma above the passive background within 1 second. Similarly, for a 500 second measurement period a lower detection limit of approaching the gram level could be expected with the same simple set-up.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creating Apptainer Workflows with Docker-Compose-like Utilities

Creating Apptainer Workflows with Docker-Compose-like Utilities In this presentation, I will explore the utilization of a tool called process-compose, inspired by docker-compose, to create Apptainer-based services. This approach allows for easy deployment and management of fully containerized applications on High Performance Computing (HPC) systems without requiring elevated privileges. Benefits to the Ecosystem: By incorporating process-compose and Apptainer, I aim to address several key challenges in the HPC ecosystem: Simplified Workflow Management: Process-compose provides a user-friendly interface for defining and managing complex containerized application services, reducing the setup time and lowering the barrier to entry for new users. Enhanced Portability: Apptainer ensures that containerized applications can run consistently across different HPC environments, promoting greater portability and reducing compatibility issues. Process-compose is also a single binary that does not need to be installed by admin level users. Community Driven Solutions: This approach aligns with the goals of the High Performance Software Foundation (HPSF) to advance community-driven solutions. By sharing our experiences and insights, I hope to foster collaboration and innovation within the HPC community. Increased Productivity: The combination of process-compose and Apptainer streamlines the serve deployment process, allowing researchers and developers to focus more on their scientific work rather than the intricacies of system or service administration. Through this presentation, attendees will gain valuable insights into the practical implementation of containerized workflows on HPC systems, learn about the benefits of using process-compose and Apptainer, and understand how these tools can contribute to a more efficient HPC ecosystem.

97 - MATHEMATICS AND COMPUTING↗

Portable quantitative confocal Raman spectroscopy: Non-destructive approach of the carbonation chemistry and kinetics

Highlights: • Raman spectroscopy was used to monitor carbonation of portlandite • The approach was non-destructive, continuous, and performed within the material • Carbonation was identified coupling Raman spectroscopy and chemometrics • Kinetics was calculated for one portlandite thickness at different CO{sub 2}-percentages Carbonation is one major alteration process of cementitious materials. It can be monitored through several methods, all destructive. In this study, some preliminary investigations were conducted to monitor the carbonation process of pure portlandite with an in situ and non-destructive spectroscopic method. This complementary approach was motivated by a literature review indicating the benefits of Raman spectroscopy, but requiring innovative approaches for data acquisition and analysis. The material was selected to validate this spectroscopic monitoring, coupled with chemometrics tools to allowing an early detection of the carbonation reaction through a structure identified in the spectra data population. The carbonation occurred abruptly, and spectra analysis indicated the occurrence of phases synonymous of microstructural evolutions. Varying the atmospheric percentage of CO{sub 2} (0.04% - 4%) conducted to an appreciation of the kinetics of the carbonation front through the same thickness of portlandite.

36 MATERIALS SCIENCE↗

Making resonance a common case: a high-performance implementation of collective I/O on parallel file systems

Collective I/O is a widely used technique to improve I/O performance in parallel computing. It can be implemented as a client-based or server-based scheme. The client-based implementation is more widely adopted in MPI-IO software such as ROMIO because of its independence from the storage system configuration and its greater portability. However, existing implementations of client-side collective I/O do not take into account the actual pattern offile striping over multiple I/O nodes in the storage system. This can cause a significant number of requests for non-sequential data at I/O nodes, substantially degrading I/O performance. Investigating the surprisingly high I/O throughput achieved when there is an accidental match between a particular request pattern and the data striping pattern on the I/O nodes, we reveal the resonance phenomenon as the cause. Exploiting readily available information on data striping from the metadata server in popular file systems such as PVFS2 and Lustre, we design a new collective I/O implementation technique, resonant I/O, that makes resonance a common case. Resonant I/O rearranges requests from multiple MPI processes to transform non-sequential data accesses on I/O nodes into sequential accesses, significantly improving I/O performance without compromising the independence ofa client-based implementation. We have implemented our design in ROMIO. Our experimental results show that the scheme can increase I/O throughput for some commonly used parallel I/O benchmarks such as mpi-io-test and ior-mpi-io over the existing implementation of ROMIO by up to 157%, with no scenario demonstrating significantly decreased performance.

42 ENGINEERING↗

Novel thermal energy storage component: Development, performance, and phase transition diagnosis

Thermal energy storage (TES) using phase change materials (PCMs) is a promising technology for capturing and storing excess thermal energy for later use. However, challenges such as poor heat transfer efficiency and a lack of modular, scalable designs have limited widespread adoption of TES in real-world applications. This study developed and evaluated modular brick-type and blade-type TES prototypes featuring an aluminum housing, an embedded serpentine coil for active or passive thermal exchange, and a cost-effective metal mesh to enhance PCM thermal conductivity. The blade-type TES achieved notable geometric efficiency, with a thickness-to-length ratio of 0.03 and a thickness-to-width ratio of 0.08, enabling highly compact and modular thermal storage suitable for space-constrained applications. The paper presents a detailed evaluation of the TES prototypes’ performance. The comparative analysis indicated that the TES prototypes provide a highly cost-effective, thermally optimized alternative for compact energy storage and load shifting. A novel diagnostic technique was also introduced: using a portable endoscope to capture real-time visualizations of PCM phase transitions inside the TES. This method provides critical insights into internal heat transfer mechanisms, identifies potential issues, and offers valuable support for optimizing the TES design and developing the control algorithm. Overall, the modular brick-type and blade-type TES designs demonstrated in this work provide a scalable, efficient, and economically viable solution for advancing TES across residential, commercial, and industrial sectors. The designs’ compact structure, enhanced thermal performance, and integrated diagnostic capabilities make them strong candidates for future deployment in energy-efficient systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Single molecule insights into interfacial molecular recognition for model electrochemical DNA biosensors

Electrochemical sensors that use surface-immobilized DNA to bind analytes and transduce the binding into electrochemical signals, have the potential for rapid, specific, and sensitive detection of bioanalytes via a compact and portable platform. However, accessing the structure of these surfaces/interfaces at the relevant spatial scale (< 10 nm), which determines the interfacial interactions and ultimately sensing performance, remains an unsolved challenge. Here, we review studies that have used high resolution atomic force microscope imaging and spatial statistical analysis tools to understand crowding interactions between thiolated DNA probes immobilized on gold electrodes and how such interactions impact target binding. We also review related studies that attempt to control the nanoscale spatial arrangement of the immobilized recognition elements to optimize sensing performance. Furthermore, these efforts have led to new advances in understanding of the structure-function relationships of DNA-based electrochemical biosensors to move the field toward rational engineering of these biosensing interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗