Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Performance of the Center-Of-Curvature Optical Assembly During Cryogenic Testing of the James Webb Space Telescope

Cryogenic testing of the James Webb Space Telescope (JWST) included center-of-curvature metrology of the 18-segment primary mirror (PM). The Center-of-Curvature Optical Assembly (COCOA) consisted of a multiple-wavelength interferometer, a reflective null, coarse and fine alignment systems, and two displacement measuring interferometer systems. The COCOA enabled alignment and phasing of the segments from millimeter-level errors down to the nanometer level. This paper describes the COCOA, the test setup, the testing performed, and the performance of the COCOA in aligning the PM segments and measuring the final PM wavefront error.

Hadaway, James↗

TPSAS-NF1676L-23266-DND

Currently, near-surface air quality information (e.g. PM_2.5) must be inferred from column-integrated quantities (i.e. Aerosol Optical Thickness – AOT) obtained by passive remote sensing from downward-looking satellite instruments. Such retrievals must address the following questions: What do we use for the height of the aerosols? Mixed Layer (ML) height? Can we assume that near-surface aerosol extinction is about the same as the mean aerosol extinction in the ML? How well is near-surface extinction related to surface PM_2.5? How well can column AOT be used to infer near-surface aerosol extinction and PM_2.5?

Richard Ferrare↗

Retrieving Particulate Matter Concentrations over the Contiguous United States Using CALIOP Observations

Using twelve years (2007-2018) of NASA Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) near-surface 532 nm aerosol extinction retrievals, multi-year mean and trends of particulate matter (PM) concentrations are derived over the contiguous United States (CONUS). Different from past studies that use column integrated aerosol optical thickness, here only near-surface CALIOP aerosol extinction is used for deriving near-surface PM with aerodynamic diameters less than 2.5 µm (PM2.5) concentrations using an innovative, bulk-mass-modeling-based method. Compared against ground based PM2.5 measurements from the U.S. Environmental Protection Agency (EPA), an encouraging relationship between CALIOP-derived PM2.5 and EPA-observed PM2.5 (Deming slope = 0.89; RMSE = 3.42 µg/m3; mean bias = -1.00 µg/m3) is found using combined daytime/nighttime CALIOP data. Also, comparable trends in PM2.5 concentrations from the EPA and daytime and nighttime CALIOP data are found for most of the eastern CONUS and imply that air quality is generally improving over this region for the study period. Over the western CONUS, a seasonal analysis reveals that PM2.5 trends are positive during the more active wildfire season (June through November) but negative for other months. This study suggests that lidar data show promise in their use for obtaining PM2.5 estimates and provides motivation to further explore aerosol extinction-based PM concentration retrievals in anticipation of future space-based lidar missions.

CALIOP↗

Asthma and Particulate Matter Pollution: Insights from Health Survey and Air Quality Monitoring in the Buzzard Point, Washington, DC Neighborhood

Air pollution, climate change, and other environmental factors contribute to increasing asthma in manycities, including Washington, DC. This work provides a case study of how community input, neighborhood-level health surveys, and air quality monitoring can inform the understanding of asthma and air pollution.A partnership between residents, concerned citizens, scientists, and educators has been working for envi-ronmental health in a DC neighborhood located on a major roadway, next to concrete batch plants andclose to several construction projects. A 2016 Community Health and Safety Study by the DC Departmentof Health, Office of Health Equity, recognized this particular neighborhood as more vulnerable to healthimpacts from recent construction in the area, compared with the surrounding areas, due to lower averageincome and higher percentage of seniors and children. This work presents neighborhood health surveysand air quality monitoring data at a more granular, local level than available from DC governmentagencies. The health surveys documented residents’ experiences around air pollution, asthma,and other health concerns. A key finding was evidence that asthma might be undercounted in thisneighborhood; among residents who did not indicate a diagnosis of asthma, many discussed havingsymptoms that could reflect asthma. Air quality monitoring (particulate matter [PM]) did not indicate thatfederal air quality standards have been violated. Real-time PM data, however,illustrated how current PMstandards, such as 1- and 24-hour averages, may fail to capture shorter duration high PM events that areconsistent with resident concerns.

Shizuka Hsieh↗

Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing

Maintaining molecular cleanliness during the JWST’s Optical Telescope/Instrument Module (OTIS) Cryogenic Thermal Vacuum (TV) test campaign was critical to the success of its optical mission on orbit. In the thermal vacuum tests leading up to the final cryogenic test to validate the OTIS flight hardware, NASA Johnson Space Center’s (JSC’s) TV Chamber A was fully characterized for molecular contamination. It was found to contain common volatile condensable materials (VCM), including hydrocarbons, plasticizers, and silicones, all of which absorb in JWST’s infrared wavelength region. Due to the risks involved, cleaning molecular contamination from the OTIS mirrors was not an option and heating the Primary Mirror (PM) segments would have also been a risky and expensive endeavor. As a result, a monitoring process was developed and implemented during four different Pathfinder or risk reduction tests that were scheduled to occur prior to the flight hardware test. The goal was to quantify and assess the risk of molecular contamination depositing on the PM resulting from relatively warm chamber shrouds “leading” colder PM mirrors during warmup, by a margin of 10-50 Kelvin (K). This was accomplished using Cryogenic Quartz Crystal Microbalances (CQCMs), held at temperatures slightly cooler than the segments to signal the onset of contamination events. Per the JWST Contamination Control Plan (CCP)1, the total Primary Mirror molecular allocation requirement was 50 angstroms. In all tests, the results showed an average accumulated molecular contamination of <10 angstroms.

optics↗

Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing

Maintaining molecular cleanliness during the JWST’s Optical Telescope/Instrument Module (OTIS) Cryogenic Thermal Vacuum (TV) test campaign was critical to the success of its optical mission on orbit. In the thermal vacuum tests leading up to the final cryogenic test to validate the OTIS flight hardware, NASA Johnson Space Center’s (JSC’s) TV Chamber A was fully characterized for molecular contamination. It was found to contain common volatile condensable materials (VCM), including hydrocarbons, plasticizers, and silicones, all of which absorb in JWST’s infrared wavelength region. Due to the risks involved, cleaning molecular contamination from the OTIS mirrors was not an option and heating the Primary Mirror (PM) segments would have also been a risky and expensive endeavor. As a result, a monitoring process was developed and implemented during four different Pathfinder or risk reduction tests that were scheduled to occur prior to the flight hardware test. The goal was to quantify and assess the risk of molecular contamination depositing on the PM resulting from relatively warm chamber shrouds “leading” colder PM mirrors during warmup, by a margin of 10-50 Kelvin (K). This was accomplished using Cryogenic Quartz Crystal Microbalances (CQCMs), held at temperatures slightly cooler than the segments to signal the onset of contamination events. Per the JWST Contamination Control Plan (CCP)1, the total Primary Mirror molecular allocation requirement was 50 angstroms. In all tests, the results showed an average accumulated molecular contamination of <10 angstroms.

molecular, contamination, thermal vacuum, cryogeni↗

An Analysis of Degradation in Low-Cost Particulate Matter Sensors

Low-cost sensors (LCSs) are increasingly being used to measure fine particulate matter (PM 2.5 ) concentrations in cities around the world. One of the most commonly deployed LCSs is PurpleAir with ∼15 000 sensors deployed in the United States, alone. PurpleAir measurements are widely used by the public to evaluate PM 2.5 levels in their neighborhoods. PurpleAir measurements are also increasingly being integrated into models by researchers to develop large-scale estimates of PM 2.5 . However, the change in sensor performance over time has not been well studied. It is important to understand the lifespan of these sensors to determine when they should be serviced or replaced, and when measurements from these devices should or should not be used for various applications. This paper fills this gap by leveraging the fact that: (1) each PurpleAir sensor is composed of two identical sensors and the divergence between their measurements can be observed, and (2) there are numerous PurpleAir sensors within 50 meters of regulatory monitors allowing for the comparison of measurements between these instruments. We propose empirically-derived degradation outcomes for the PurpleAir sensors and evaluate how these outcomes change over time. On average, we find that the number of ‘flagged’ measurements, where the two sensors within each PurpleAir sensor disagree, increases with time to ∼4% after 4 years of operation. Approximately, 2 percent of all PurpleAir sensors were permanently degraded. The largest fraction of permanently degraded PurpleAir sensors appeared to be in the hot and humid climate zone, suggesting that sensors in these locations may need to be replaced more frequently. We also find that the bias of PurpleAir sensors, or the difference between corrected PM2.5 levels and the corresponding reference measurements, changed over time by −0.12 μg m −3 (95% CI: −0.13 μg m −3 , −0.10 μg m −3 ) per year. The average bias increases dramatically after 3.5 years. Further, climate zone is a significant modifier of the association between degradation outcomes and time.

Priyanka deSouza↗

Leveraging Scientific Community Knowledge for Air Quality Model Chemistry Parameterizations

Air pollution contributes to adverse health outcomes. Approximately 121 million people in the United States—one third of the population—live where National Ambient Air Quality Standards (NAAQS) are violated. In most cases, the criteria pollutants exceeding standards are ozone (O 3 ) and fine particles (PM 2.5 ). In addition, 188 substances known or suspected to cause cancer or other serious health effects are designated as hazardous air pollutants (HAPs). Essentially, all O 3 and significant portions of PM 2.5 and HAPs are produced in the atmosphere through chemical and physical processes. In the case of PM 2.5 , subcomponents formed primarily from precursor gases—sulfate, nitrate, ammonium, and secondary organic aerosol (SOA)—account for 60% of the U.S. county-level annual mean concentration. In addition, 47% of the cancer risk and 25% of the noncancer risk from HAPs have been attributed to atmospheric chemistry rather than direct emissions. In this article, we introduce the role of chemical mechanisms in air quality models, a new atmospheric science community effort, and needs for further mechanism development.

Havala O.T. Pye↗

Paint and Oil Locker SWMU 067 Southern Treatment Area Air Sparge System Year 2 Performance Monitoring and Paint and Oil Locker Northern Area (SWMU 067) and Supply Warehouse #3, SWMU 088 Long-Term Monitoring Kennedy Space Center, Florida

This Year 2 Air Sparge (AS) System Performance Monitoring (PM) Report for Paint and Oil Locker (POL) Solid Waste Management Unit (SWMU) 067 Southern Treatment Area and Long- Term Monitoring (LTM) Report for POL Northern Area (SWMU 067) and Supply Warehouse #3 (SW3) SWMU 088 documents ongoing remedial efforts at the POL and SW3 sites at Kennedy Space Center (KSC), Florida. The overall goal for these sites is to reduce concentrations of groundwater contaminants of concern (COCs), specifically trichloroethene (TCE), cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE) and vinyl chloride (VC), to below the State of Florida Groundwater Cleanup Target Levels (GCTLs). Remediation and reporting of POL and SW3 have been streamlined over the years due to the proximity of the two sites. The scope for these sites currently includes two main components: (1) LTM at SW3 and the POL Northern Area, where an AS system began operation in May 2009 (with expansion in December 2012) and June 2013, respectively, and subsequently turned off for both sites in March 2018 (NASA, 2019a); and (2) Active AS operations and PM in the POL Southern Treatment Area where an AS system was installed and began operation in 2021. The timeframe for activities covered under this report is from September 2022 to July 2023. Based on Year 2 system operation and PM results, the AS system at POL operated as designed and successfully met the performance objective of reducing VOCs to concentrations that support transition of the site from active remediation to long-term monitoring. The results from the samples collected from performance monitoring wells within the AS system ROI showed a significant decrease in COC concentrations since the baseline sampling event conducted in April 2020. Based on the Year 2 OM&M and monitoring results obtained from the POL Southern Treatment Area, the IM objective to reduce concentrations to below the LTM transition target concentrations for TCE, cDCE, tDCE, and VC has been achieved. LTM sampling events at SW3 were conducted in October 2022 and July 2023. LTM sampling was conducted at the POL Northern Area in October 2022, December 2022, March 2023, and July 2023. Analytical results from October 2022 and July 2023 generally indicate that concentrations of COCs have been stable or decreasing compared to the previous year. TCE remains greater than the NADC in one monitoring well (POL-MW0034S) and greater than the GCTL in one monitoring well (POL-MW0009S). Concentrations of cDCE were greater than the GCTL in one monitoring well (POL-MW0026S), and tDCE was non-detect or less than the GCTL in all monitoring wells sampled. VC was greater than the GCTL in four monitoring wells (MW0024, MW0025, MW0027, and MW0028) at SW3 and one monitoring well (MW0026S) at the POL Northern Area.

remediation↗

Improvements to the Powder Processing of near-Final Shape alnico Magnets

Alnico permanent magnets (PMs), a recent PM system of interest as an attractive rare earth-free PM alternative, have advantageous high operating temperature and magnetic saturation with the potential for utilization in electric machines, e.g. interior-PM motors found in electric vehicles, if current directional solidification methods can be replaced by a true mass production approach. Recently, two unique alnico compositions, termed Full-Co and Co-lean, with improved coercivity, were gas atomized, compression molded, and vacuum sintered (4h at 1240°C) to high densities of 97.8% and 99.3%, respectively. However, the Co-lean remained fine grained isotropic magnets and the Full-Co grains were not textured, lowering magnetic strength in spite of attempts to grow large textured grains by a stress-biased solid state grain alignment method to convert them to high energy anisotropic magnets. It was hypothesized that oxidation during de-binding in air left many prior particle boundary oxides within the sintered microstructure that hindered grain growth and texturing during the stress-biased texturing procedure and prevented the desired abnormal grain growth (AGG). Here we explored a vacuum de-binding step that was linked (in-place) to vacuum sintering and found that the Co-lean exhibited faster uniform grain growth that doubled the average grain size (40 μm to 80 μm). Linked vacuum de-binding and sintering of Full-Co produced some AGG after only 1 h of 1240°C sintering. A new direction for promoting AGG (and stress-biased texturing) in alnico is being explored that utilizes a fundamental analysis of systems with second phase particles that either inhibit or boost grain growth. This effort explores the influence of vacuum de-binding linked to a series of lower sintering temperatures at a fixed time (4h) to see if oxide particle size and volume fraction can be changed to promote AGG conditions in alnico. Surprising qualitative results indicate that AGG may be promoted for vacuum sintering at less than 1200°C.

Rinko, Emily↗

Measurement of $d^2 \sigma/d|\vec{q}|d E_{avail}$ and 2p2h contribution using charged current $\nu_\mu$ interactions in the NOvA Near Detector

This Thesis presents the analysis methods and measurement of the $d^2 \sigma/d|\vec{q}|d E_{avail}$-CC inclusive cross section that describes neutrino scattering in a predominantly hydrocarbon medium. Studies that are prerequisite for the analysis including, variable determinations, event selections, efficiency, purity determinations, and systematic uncertainty estimations, are summarized. Tests of the analysis are also detailed, and shown to reproduce the input distributions. The double-differential cross-section measurement provides the foundation for determination of the inclusive rate for the excess induced by 2p2h processes together with nuclear medium effects that are not described by the Fermi gas model. The methodology for the extraction of this rate, defined as the excess observed relative to the rate estimated for known single-nucleon interactions, is described in detail. The following new measurements are reported in this Thesis: (1) The $\nu_\mu-$CC inclusive double-differential cross section as a function of three-momentum transfer and available hadronic energy, for an average $E_\nu$ of 1.8 GeV, is obtained. The double-differential cross section value that obtains when the bin widths are taken to be the dimensions of the entire analysis domain, e.g. $0.2 \le |\vec{q}| \le 2.0 GeV/c$ and $0.0 \le E_{avail} \le 2.0$ GeV, is inclusive cross section is $(6.05 \pm 0.75)\times10^{-39}$ cm$^2$/GeV/GeV/$c$/nucleon. An event excess attributed to 2p2h-MEC processes is observed; most of the rate occurs in a contiguous phase space region $0.3 \le |\vec{q}| \le 1.0$ GeV$/c$ $0.0 \le E_{avail} \le 0.35$ GeV. This rate represents $12.0\pm 6.5\%$ of the observed CC inclusive cross section; its cross section ratio relative to CCQE scattering is estimated to be $44.3 \pm 23.9\%$.

Olson, Travis Grant↗

Observation of the rare decay of the $\eta$ meson to four muons

A search for the rare $\eta$$\to$$\mu^+\mu^-\mu^+\mu^-$ double-Dalitz decay is performed using a sample of proton-proton collisions, collected by the CMS experiment at the CERN LHC with high-rate muon triggers in 2017-2018 and corresponding to an integrated luminosity of 101 fb$^{-1}$. A signal having a statistical significance well in excess of 5 standard deviations is observed. Using the \emm decay as normalization, the branching fraction $\mathcal{B}($η$ \to \mu^+\mu^-\mu^+\mu^-)$ = ( 5.0 $\pm$ 0.8 (stat) $\pm$ 0.7 (syst) $\pm$ 0.7 $\mathcal{B}_{2\mu}$ ) $\times$ 10$^{-9}$ is measured, where the last term is the uncertainty in the normalization channel branching fraction. This is the first measurement of this branching fraction and is found to be in agreement with theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

Clustering of high-redshift quasars with DESI DR2

We present clustering measurements for high-redshift quasars using data from the Dark Energy Spectroscopic Instrument Data Release 2. Our sample consists of quasars with $2.0 < z < 3.5$ in the luminosity range $M_{1450} \leq -19.94$ mag. We measure the mean quasar bias $b_Q(\bar{z} = 2.48) = 3.61 \pm 0.01$ for the full sample of $\sim 715,000$ quasars and quantify the redshift evolution of quasar bias by dividing the sample into four equal redshift bins. There is strong evolution of the quasar bias with redshift that is well fit by the function $b_Q(z) = a [(1 + z)^2 - 6.565] + b$ with $a=0.230 \pm 0.007$ and $b=2.394 \pm 0.035$, and this fit is also a good match to lower redshift measurements in the literature. This bias evolution is consistent with a characteristic halo mass of $\bar{M}_{\mathrm{h}} \sim 10^{12}\,\mathrm{M_\odot}$ that does not vary significantly with redshift. The inferred duty cycles for quasars in our sample are $f_{\mathrm{duty}} \sim 10^{-2}$, staying mostly constant over redshifts. We investigate the luminosity dependence of quasar clustering by dividing each of our four redshift bins into three luminosity bins. The size of our quasar sample permits the first statistically significant measurement of the luminosity dependence of quasar bias at these redshifts. We measure weak dependence of quasar bias on luminosity at fixed redshift, inconsistent with no dependence, but weaker than predicted by a model in which quasar luminosity is tightly correlated with halo mass. These clustering measurements provide a stringent test for models of active black hole light curves and the black hole-halo connection at high redshift.

Charles, M. [Ohio State U.; Chicago U., KICP] (ORC↗

Validation of an Erythema-Weighted UV Model Using Broadband Solar Irradiance Measurements From Eleven U.S. Sites: Preprint

Erythema-weighted UV solar irradiance (UV-E) has a potential impact on human health if the recommended maximum exposure times are exceeded. In spite of this, it is not measured at most sites that measure Global Horizontal Irradiance (GHI). However, since UV-E is highly correlated with GHI and total ozone content it can be estimated from this information with sufficient accuracy to assisst in public health recommendations. The Power Model (PM) provides a simple method to estimate the erythema-weighted UV irradiance (UV-E) from measured GHI, total ozone column and air mass. In this work, the performance of the PM method is assessed using high-quality data from 11 sites in the continental U.S. (part of SURFRAD and SOLRAD networks) and total ozone estimates publicly available from the MERRA-2 re-analysis database. A three year period (2021- 2023) at 1-minute frequency is considered. The results (for time aggregations of 5 and 60 minutes) show a high Pearson's correlations (> 0.99), consistently positive mean bias deviations (below 13%) and dispersions in the 8-19% range at all sites. Relative values are expressed in terms of the corresponding measurement mean. The performance indicators remain consistent across time resolutions (5 or 60 minutes), suggesting that the model's performance is robust and not significantly affected by short-term variability (which is captured by GHI). Spatial patterns reveal higher biases and RMSD in northern and eastern locations. These values represent a significant improvement over widely used satellite-based global UV-E estimates and open the possibility of using the PM with satellite-based GHI estimates for operational UV-E mapping over the contiguous U.S. territory.

14 SOLAR ENERGY↗

In-situ polarization modulation IRRAS investigation of ammonia electrooxidation on Pt-Ir and Pt-Ru nanoparticles prepared on engineered catalyst supports

The catalytic activity and surface reactivity of monometallic Pt and bimetallic Pt-Ir and Pt-Ru nanoparticles, supported on two distinct Engineered Catalyst Supports (ECSs), were investigated for the Ammonia Electrooxidation Reaction (AmER) in alkaline media. XRD measurements confirmed alloy formation between Pt-Ir and Pt-Ru nanoparticles, as indicated by the shift of the (111) reflection to higher 2θ values. Cyclic voltammetry, linear sweep voltammetry, and chronoamperometry experiments were conducted to assess the catalytic activity of the Pt, Pt-Ir, and Pt-Ru electrocatalysts. All bimetallic catalysts exhibited lower onset potentials compared to Pt. The differing Tafel slopes between Pt (74 mV dec⁻¹), Pt-Ir (152 mV dec⁻¹), and Pt-Ru (118–197 mV dec⁻¹) suggest that alloying Pt with Ir or Ru alters the reaction mechanisms. Furthermore, the bimetallic Pt-Ir and Pt-Ru catalysts demonstrated greater tolerance for concentrated ammonia solutions relative to Pt. In-situ Polarization Modulation Infrared Reflection Absorption Spectroscopy (PM-IRRAS) provided insights into the formation of N-H species, azide anions (N₃⁻), and N-O compounds. For the Pt-Ru catalyst, an additional peak around ~3600 cm⁻¹ was observed, corresponding to OH⁻ species. The PM-IRRAS results align with the Gerischer–Mauerer mechanism, indicating that partially dehydrogenated ammonia adsorbates act as active intermediates in the oxidation of ammonia over Pt-Ir and Pt-Ru catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural characterization of HIV-1 matrix mutants implicated in envelope incorporation

During the late phase of HIV-1 infection, viral Gag polyproteins are targeted to the plasma membrane (PM) for assembly. Gag localization at the PM is a prerequisite for the incorporation of the envelope protein (Env) into budding particles. Gag assembly and Env incorporation are mediated by the N-terminal myristoylated matrix (MA) domain of Gag. Nonconservative mutations in the trimer interface of MA (A45E, T70R, and L75G) were found to impair Env incorporation and infectivity, leading to the hypothesis that MA trimerization is an obligatory step for Env incorporation. Conversely, Env incorporation can be rescued by a compensatory mutation in the MA trimer interface (Q63R). The impact of these MA mutations on the structure and trimerization properties of MA is not known. In this study, we employed NMR spectroscopy, X-ray crystallography, and sedimentation techniques to characterize the structure and trimerization properties of HIV-1 MA A45E, Q63R, T70R, and L75G mutant proteins. NMR data revealed that these point mutations did not alter the overall structure and folding of MA but caused minor structural perturbations in the trimer interface. Analytical ultracentrifugation data indicated that mutations had a minimal effect on the MA monomer–trimer equilibrium. The high-resolution X-ray structure of the unmyristoylated MA Q63R protein revealed hydrogen bonding between the side chains of adjacent Arg-63 and Ser-67 on neighboring MA molecules, providing the first structural evidence for an additional intermolecular interaction in the trimer interface. These findings advance our knowledge of the interplay of MA trimerization and Env incorporation into HIV-1 particles.

60 APPLIED LIFE SCIENCES↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗