Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Imaging of large-area microchannel plates using phosphor screens

A testing system was built, using UV illumination at 254 nm and a cathodoluminescent phosphor screen, to measure the gain uniformity of large area (20 x 20 cm(2)) microchannel plates. The phosphor screen image is captured with a wide-angle CMOS digital camera (4032 x 3024 pixels) and analyzed. First a reference MCP is illuminated and the generated phosphor screen image is captured with a CCD camera. In a second step, another image is captured with the MCP under test inserted between the reference MCP and the phosphor screen. The ratio of the two images is analyzed and provides a quantitative measure of the relative gain uniformity of the MCP under test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIRST RESULTS FROM VERY LARGE TELESCOPE NACO APODIZING PHASE PLATE: 4 {mu}m IMAGES OF THE EXOPLANET {beta} PICTORIS b

Direct imaging of exoplanets requires both high contrast and high spatial resolution. Here, we present the first scientific results obtained with the newly commissioned apodizing phase plate coronagraph (APP) on VLT/NACO. We detected the exoplanet {beta} Pictoris b in the narrowband filter centered at 4.05 {mu}m (NB4.05). The position angle (209.{sup 0}13 {+-} 2.{sup 0}12) and the projected separation to its host star (0.''354 {+-} 0.''012, i.e., 6.8 {+-} 0.2 AU at a distance of 19.3 pc) are in good agreement with the recently presented data from Lagrange et al. Comparing the observed NB4.05 magnitude of 11.20 {+-} 0.23 mag to theoretical atmospheric models, we find a best fit with a 7-10 M {sub Jupiter} object for an age of 12 Myr, again in agreement with previous estimates. Combining our results with published L' photometry, we can compare the planet's [L' - NB4.05] color to that of cool field dwarfs of higher surface gravity suggesting an effective temperature of {approx}1700 K. The best-fit theoretical model predicts an effective temperature of {approx}1470 K, but this difference is not significant given our photometric uncertainties. Our results demonstrate the potential of NACO/APP for future planet searches and provide independent confirmation as well as complementary data for {beta} Pic b.

79 ASTRONOMY AND ASTROPHYSICS↗

Comprehensive earthquake catalogue update and spatiotemporal distribution analysis for Iraq and surrounding regions, northeastern Arabian Plate

The updated earthquake catalogue for Iraq covers the period from 1900 to the end of 2021 and includes over 37 000 recorded earthquakes. To create this comprehensive catalogue, five key steps were taken: compiling bulletins, calculating moment magnitudes, harmonizing magnitudes, establishing empirical conversion relations and evaluating the completeness of the catalogue. A notable enhancement in this update is the direct calculation of moment magnitudes for approximately 2800 earthquakes, achieved through the coda envelope technique and waveform data from the Mesopotamian Seismological Network (MPSN) in Iraq. This updated catalogue serves as a valuable resource for examining the spatiotemporal distribution of earthquakes, with respect to earthquake density, maximum moment magnitude and seismogenic depths. Additionally, the Gutenberg–Richter relationship was applied to calculate the a- and b-values specific to Iraq. The findings show that the Zagros Fold-Thrust Belt has a seismogenic layer (source) that ranges from 2 to 33 km deep and experiences high seismic activity. In contrast, the Mesopotamian Foredeep has a seismogenic layer ranging from 1 to 25 km deep and has lower seismic activity. The greatest seismic activity is concentrated around the Mandili-Badra-Teeb fault, which has experienced significant ruptures over time. The Outer Arabian Platform is identified as the main area of seismic activity, while additional activity occurs on the Inner Arabian Platform. Three major tectonic boundaries define the distribution of earthquakes in the northeastern Arabian Plate. These boundaries are defined by the Main Zagros Reverse Fault, the Zagros Foredeep Fault and the Anah Graben and Abu Jir-Euphrates Fault Zone. These boundaries highlight variations in seismicity levels and the spatial distribution of deformation in the region. The updated earthquake catalogue presented in this study is expected to play a vital role in regional seismicity assessments and seismic hazard analyses for Iraq and its surrounding areas.

58 GEOSCIENCES↗

On the nature of apparent transient sources on the National Geographic Society–Palomar Observatory Sky Survey glass copy plates

Abstract We examine critically recent claims for the presence of above-atmosphere optical transients in publicly available digitized scans of Schmidt telescope photographic plate material derived from the National Geographic Society–Palomar Observatory Sky Survey. We employ the publicly available SuperCOSMOS Sky Survey catalogues to examine statistically the morphology of the sources. We develop a simple, objective, and automated image classification scheme based on a random forest decision tree classifier. We find that the putative transients are likely to be spurious artefacts of the photographic emulsion. We suggest a possible cause of the appearance of these images as resulting from the copying procedure employed to disseminate glass copy survey atlas sets in the era before large-scale digitization programmes.

Hambly, N. C. (ORCID:0000000299019064)↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Temperature dependence of Eu-related EPR spectra in CsBr:Eu needle image plates

Vacuum-deposited CsBr needle plates doped with Eu{sup 2+} have been investigated with Q ({approx}34 GHz) and W ({approx}95 GHz) band electron paramagnetic resonance in a large temperature interval (4 K: room temperature). At low temperatures (<35 K), two Eu-related centers were found with different symmetry (tetragonal and orthorhombic), while in earlier studies at room temperature only one center was found with tetragonal symmetry. Possible models for the three defects are investigated, taking into account their temperature behavior, their symmetry, and the atypical values of their zero-field splitting parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling the behavior of inclusions in circular plates undergoing shape changes from two to three dimensions

Growth of biological tissues and shape changes of thin synthetic sheets are commonly induced by stimulation of isolated regions (inclusions) in the system. These inclusions apply internal forces on their surroundings that, in turn, promote 2D layers to acquire complex 3D configurations. Here we focus on a fundamental building block of these systems, and consider a circular plate that contains an inclusion with dilative strains. Based on the Föppl-von Kármán (FvK) theory, we derive an analytical model that predicts the 2D-to-3D shape transitions in the system. Our findings are summarized in a phase diagram that reveals two distinct configurations in the post-buckling region. One is an extensive profile that holds close to the threshold of the instability, and the second is a localized profile, which preempts the extensive solution beyond the buckling threshold. While the former solution is derived as a perturbation around the flat configuration, assuming infinitesimal amplitudes, the latter solution is derived around a buckled state that is highly localized. We show that up to vanishingly small corrections that scale with the thickness, this localized configuration is equivalent to that expected for ultra-thin sheets, which completely relax compressive stresses. Our findings agree quantitatively with direct numerical minimization of the FvK energy. Furthermore, we extend the theory to describe shape transitions in polymeric gels, and compare the results with numerical simulations that account for the complete elastodynamic behavior of the gels. The agreement between the theory and these simulations indicates that our results are observable experimentally. Notably, our findings can provide guidelines to the analysis of more complicated systems that encompass interaction between several buckled inclusions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Buckling-induced interaction between circular inclusions in an infinite thin plate

Design of slender artificial materials and morphogenesis of thin biological tissues typically involve stimulation of isolated regions (inclusions) in the growing body. These inclusions apply internal stresses on their surrounding areas that are ultimately relaxed by out-of-plane deformation (buckling). Here, we utilize the Föppl-von Kármán model to analyze the interaction between two circular inclusions in an infinite plate that their centers are separated a distance of 2ℓ. In particular, we investigate a region in phase space where buckling occurs at a narrow transition layer of length ℓ D around the radius of the inclusion, $R (ℓ_D \ll R)$. We show that the latter length scale defines two regions within the system, the close separation region, $ℓ – R \sim ℓ_D$, where the transition layers of the two inclusions approximately coalesce, and the far separation region, $ℓ – R \gg ℓ_D$. While the interaction energy decays exponentially in the latter region, $E_{\text{int}} ∝ e^{– (ℓ – R)/ℓ_D}$, it presents nonmonotonic behavior in the former region. While this exponential decay is predicted by our analytical analysis and agrees with the numerical observations, the close separation region is treated only numerically. In particular, we utilize the numerical investigation to explore two different scenarios within the final configuration: The first where the two inclusions buckle in the same direction (up-up solution) and the second where the two inclusions buckle in opposite directions (up-down solution). We show that the up-down solution is always energetically favorable over the up-up solution. In addition, we point to a curious symmetry breaking within the up-down scenario; we show that this solution becomes asymmetric in the close separation region.

42 ENGINEERING↗

Ultrahigh-Resolution Soft-X-Ray Microscopy with Zone Plates in High Orders of Diffraction

We present an x-ray optical approach to overcome the current limitations in spatial resolution of x-ray microscopes. Our new BESSY full-field x-ray microscope operates with an energy resolution up to E/DELTAE=10{sup 4}. We demonstrate that under these conditions it is possible to employ high orders of diffraction for imaging. Using the third order of diffraction of a zone plate objective with 25 nm outermost zone width, 14 nm lines and spaces of a multilayer test structure were clearly resolved. We believe that high-order imaging paves the way towards sub-10-nm real space x-ray imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Arabidopsis CSLD 5 functions in cell plate formation in a cell cycle-dependent manner

In plants, the presence of a load-bearing cell wall presents unique challenges during cell division. Unlike other eukaryotes, which undergo contractile cytokinesis upon completion of mitosis, plants instead synthesize and assemble a new dividing cell wall to separate newly formed daughter cells. In this study, we mine transcriptome data from individual cell types in the Arabidopsis thaliana stomatal lineage and identify CSLD5, a member of the Cellulose Synthase Like-D family, as a cell wall biosynthesis enzyme uniquely enriched in rapidly dividing cell populations. We further show that CSLD5 is a direct target of SPEECHLESS, the master transcriptional regulator of these divisions during stomatal development. Using a combination of genetic analysis and in vivo localization of fluorescently tagged fusion proteins, we show that CSLD5 preferentially accumulates in dividing plant cells where it participates in the construction of newly forming cell plates. We show that CSLD5 is an unstable protein that is rapidly degraded upon completion of cell division and that the protein turnover characteristics of CSLD5 are altered in ccs52a2 mutants, indicating that CSLD5 turnover may be regulated by a cell cycle-associated E3-ubiquitin ligase, the anaphase-promoting complex.

59 BASIC BIOLOGICAL SCIENCES↗

Solvent minimization induces preferential orientation and crystal clustering in serial micro-crystallography on micro-meshes, in situ plates and on a movable crystal conveyor belt

X-ray diffraction data were obtained at the National Synchrotron Light Source from insulin and lysozyme crystals that were densely deposited on three types of surfaces suitable for serial micro-crystallography: MiTeGen MicroMeshes™, Greiner Bio-One Ltd in situ micro-plates, and a moving kapton crystal conveyor belt that is used to deliver crystals directly into the X-ray beam. 6° wedges of data were taken from ~100 crystals mounted on each material, and these individual data sets were merged to form nine complete data sets (six from insulin crystals and three from lysozyme crystals). Insulin crystals have a parallelepiped habit with an extended flat face that preferentially aligned with the mounting surfaces, impacting the data collection strategy and the design of the serial crystallography apparatus. Lysozyme crystals had a cuboidal habit and showed no preferential orientation. Preferential orientation occluded regions of reciprocal space when the X-ray beam was incident normal to the data-collection medium surface, requiring a second pass of data collection with the apparatus inclined away from the orthogonal. In addition, crystals measuring less than 20 µm were observed to clump together into clusters of crystals. Clustering required that the X-ray beam be adjusted to match the crystal size to prevent overlapping diffraction patterns. No additional problems were encountered with the serial crystallography strategy of combining small randomly oriented wedges of data from a large number of specimens. Lastly, high-quality data able to support a realistic molecular replacement solution were readily obtained from both crystal types using all three serial crystallography strategies.

36 MATERIALS SCIENCE↗

Damp Heat Induced Degradation of Silicon Heterojunction Solar Cells With Cu-Plated Contacts

Damp heat exposure is one of the most stringent environments for testing the durability of solar cells in packaged modules. Damp heat stresses and induces a variety of degradation modes in solar cells and modules: for example, moisture-induced corrosion of electrodes and interconnections, deterioration of polymeric materials, and/or thermally activated diffusion processes. To screen for these and other potential degradation modes, we subject one-cell modules containing silicon heterojunction (SHJ) solar cells with Cu-plated contacts to extended damp heat tests at 85 °C/85% relative humidity. SHJ cells were laminated with two common encapsulants: ethylene vinyl acetate (EVA) and polyolefin elastomer (POE), and two constructions: glass-backsheet and glass-glass. We observe degradation in all components of solar cell maximum power (PMP): current, voltage, and fill factor, and find evidence of increased carrier recombination and nonideal diode behavior with increasing stress. For glass-backsheet constructions, EVA samples generally degrade more than POE by a factor of approximately 1.5x PMP, and the different encapsulants produce different degradation patterns. Similar trends are observed in glass-glass modules, but to a lesser degree. In a different experiment, we observe a decrease in effective minority carrier lifetime of nonmetallized SHJ precursors measured after damp heat. This implies that some degradation unrelated to the contacts is to be expected and confirms the observation of increasing recombination.

14 SOLAR ENERGY↗

A Neutron Sensitive Microchannel Plate Detector with Cross Delay Line Readout

Microchannel plates containing neutron absorbing elements such as boron and gadolinium in the bulk glass are used as the sensing element in high spatial resolution, high rate neutron imaging systems. In this paper we describe one such device, using both 10 B and natural Gd, which employs cross delay line signal readout, with time-of-flight capability. This detector has a measured spatial resolution under 40 m FWHM, thermal neutron efficiency of 19%, and has recorded rates in excess of 500 kHz. A physical and functional description is presented, followed by a discussion of measurements of detector performance and a brief survey of some practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Top Plate and Anticryostat for High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (Fermilab) is currently constructing a new High Field Vertical Magnet Test Facility (HFVMTF) designed for testing High Temperature Superconducting (HTS) cables under high magnetic fields. This facility is expected to offer capabilities similar to those of EDIPO at PSI and FRESCA2 at CERN. The background magnetic field of 15 T will be generated by a magnet supplied by Lawrence Berkeley National Laboratory. The primary function of HFVMTF will be to serve as a superconducting cable test facility, facilitating tests under high magnetic fields and a broad spectrum of cryogenic temperatures. Additionally, the facility will be utilized for testing high-field superconducting magnet models and demonstrators, including hybrid magnets, developed by the US Magnet Development Program (MDP). This paper provides a comprehensive description of the current status of two pivotal components of the facility: the Top/Lambda Plates Assembly and the Anticryostat for the Test Sample Holder. The latter will serve as a principal interface component connecting cable test samples with the facility's cryostat.

43 PARTICLE ACCELERATORS↗

Comparative Response of Microchannel Plate and Channel Electron Multiplier Detectors to Penetrating Radiation in Space

Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area of multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

Electronically Conductive Vanadate Glasses for Resistive Plate Chamber Particle Detectors

Particle detectors are constantly being built and refitted with new technology to improve the spatial resolution, radiation hardness, and speed at which the detector can capture particle events. One of the most crucial components of a modern collider experiment is the hadron calorimeter. One of the proposed improvements on future hadron calorimeters is to utilize resistive plate chambers (RPCs). They provide the spatial and energy resolution as well as could provide speed and radiation hardness. RPCs depend on manufacturing electrically conductive glasses that are mechanically strong, durable, radiation resistant, and not ionically conductive. To achieve such requirements, vanadate glasses were developed as alternatives to current prototypes which use soda lime silicate glasses. The conductivity, oxidation states of vanadium, radiation hardness, as well as the prototype performance, were tested on vanadate glasses. The prototype tests show that using 0.40ZnO−0.40TeO 2 −0.20V 2 O 5 can improve the RPC detector rate up to 100 times.

Johnson, Nicole↗

2D photonic crystal layer assisted thiosilicate ceramic plate with red-emitting film for high quality w -LEDs

In this work, we have succeeded in obtaining high quality warm w-light-emitting-diodes (LEDs) by adopting hybrid two-dimensional (2D) structure of SiNx photonic crystal layer (PCL) assisted cyan-emitting ceramic-plate thiosilicate SrLa2Si2S8:Ce3+ with red-emitting film SrLiAl3N4:Eu2+ phosphor on a 430 nm blue LED chip at 350 mA. 2D SiNx PCL was capped with thiosilicate is because it can enhance the luminous efficacy and maintain the low correlated color temperature (CCT) and high color-rendering index (CRI). High luminous efficacy (82.3 lm/W), high special CRI (R9=75) as well as the low CCT (5431 K) of the optimal w-LED was obtained due to the assistances of 2D SiNx PCL and narrow-band red-emitting phosphor with the doping percentage at 10 wt%. The synthesis processes, structural analysis, optical properties and LED device performances were detailed investigated to find out the relationship between the optimum composition and good optical properties. Based on intriguing luminescence properties by the 2D SiNx PCL and red-emitting film phosphor introducing, we proclaim this method could also have high potential application in other phosphor-converted w-LEDs.

36 MATERIALS SCIENCE↗

Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture

Aims: We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials, and assay methods on false-negative rate (FNR) and limit of detection (LOD95) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Methods and Results: Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2 – 500 coupon-1) onto glass, stainless steel, vinyl tile, and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD95 results. Conclusions: Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD95 was lowest for glass and highest for vinyl tile. LOD95 values overall were lower for mRV-PCR than for the culture method. Significance and Impact of Study: This study adds to the limited data on FNR and LOD95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis.

Bacillus spores↗